1
|
Cheniski DA, Freire A, Camargo ES, da Costa RG, de Souza EM, Rached RN. Bond strength of prefabricated and CAD-CAM milled glass fiber post-and-cores luted with conventional, universal, and self-adhesive composite resin cement. J Prosthet Dent 2024; 131:251.e1-251.e7. [PMID: 38368000 DOI: 10.1016/j.prosdent.2023.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 11/18/2023] [Accepted: 11/20/2023] [Indexed: 02/19/2024]
Abstract
STATEMENT OF PROBLEM Little is known about the effect of different composite resin cements on the bond strength of prefabricated and milled glass fiber post-and-cores. PURPOSE The purpose of this in vitro study was to compare the push-out bond strengths of root dentin and standard, relined, or computer-aided design and computer-aided manufacturing (CAD-CAM) glass fiber post-and-cores luted with conventional, universal, or self-adhesive composite resin cement. MATERIAL AND METHODS Post spaces were prepared in 90 premolars. Standard and relined prefabricated and CAD-CAM-milled glass fiber post-and-cores were luted with conventional (RelyX ARC; 3M ESPE), universal (RelyX Ultimate; 3M ESPE), and self-adhesive (RelyX U200; 3M ESPE) composite resin cement (n=10). All specimens were thermally aged (5000 cycles at 5°C and 55°C with a 20-second dwell time) and mechanical fatigue (1 000 000 cycles at 2 Hz, 50-N load). The specimens were sectioned perpendicularly to the root long axis into 1-mm-thick sections (apical, middle, and cervical root thirds), the push-out bond strength was determined, and the mode of failure recorded. Data were submitted to the Kruskal-Wallis test followed by the Bonferroni-Dunn multiple comparison test (α=.05). RESULTS Push-out bond strength values did not differ (P>.05) among posts at the same root thirds. Standard posts showed higher bond strength than CAD-CAM at the apical third for data grouped by composite resin cements (P<.001). The cervical root thirds had higher bond strength than the apical thirds (P<.05). The cervical, middle, and apical root thirds showed decreasing bond strength values for each type of post for data grouped by composite resin cement (P<.001). Adhesive failures at the dentin-cement interface were predominant. CONCLUSIONS The type of posts and cements did not affect the bond strength of glass fiber posts. The cervical root thirds had better bonding performance than the apical thirds.
Collapse
Affiliation(s)
- Djulyeny Adolfo Cheniski
- Master's student, Graduate Program in Dentistry, School of Medicine and Life Sciences, Pontifical Catholic University of Paraná (PUCPR), Curitiba, Brazil
| | - Andrea Freire
- Professor, Faculty of Dentistry, Federal University of Mato Grosso do Sul (UFMS), Campo Grande, Brazil
| | - Elisa Souza Camargo
- Professor, Graduate Program in Dentistry, School of Medicine and Life Sciences, Pontifical Catholic University of Paraná (PUCPR), Curitiba, Brazil
| | - Rogério Goulart da Costa
- Professor, Dental Prosthesis Course, Federal Institute of Paraná (IFPR), and Dental Course, School of Medicine and Life Sciences, Pontifical Catholic University of Paraná (PUCPR), Curitiba, Brazil
| | - Evelise Machado de Souza
- Professor, Graduate Program in Dentistry, School of Medicine and Life Sciences, Pontifical Catholic University of Paraná (PUCPR), Curitiba, Brazil
| | - Rodrigo Nunes Rached
- Professor, Graduate Program in Dentistry, School of Medicine and Life Sciences, Pontifical Catholic University of Paraná (PUCPR), Curitiba, Brazil.
| |
Collapse
|
2
|
Lima RO, Barros APO, Alencar CDM, Pereira KDF, Galvani LD, Vaz LG, Campos EAD, Kuga MC. Influence of using different translucent composite resins for customizing fiber post on the bond strength of self-adhesive cement to root dentin. Dent Mater J 2024; 43:112-118. [PMID: 38072411 DOI: 10.4012/dmj.2023-184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment. Bond strength values were submitted to 2-way ANOVA test. ZV and ZR showed higher bond strength values than the other groups at 6 months of evaluation (p<0.05). The Z350 resin has a favorable influence on the bond strength of self-adhesive cement to root dentin, regardless of the LED polymerization equipment used.
Collapse
Affiliation(s)
- Reinaldo Oliveira Lima
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| | | | - Cristiane De Melo Alencar
- Department of Restorative Dentistry, School of Dentistry, University Center of the State of Pará (CESUPA)
| | | | - Lucas David Galvani
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| | - Luís Geraldo Vaz
- Department of Dental Materials and Prosthetics Araraquara Dental School, São Paulo State University (UNESP)
| | - Edson Alves De Campos
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| | - Milton Carlos Kuga
- Department of Operative Dentistry, Araraquara Dental School, São Paulo State University (UNESP)
| |
Collapse
|
3
|
Gontijo IG, Ferretti MA, Caldas RA, Pecorari VGA, França FMG, Oliveira LKN, Aguiar FHB. Biomechanical behavior of weakened roots restored with custom-made post-and-cores of glass fiber and polyetheretherketone. J Prosthodont 2023; 32:807-814. [PMID: 36482016 DOI: 10.1111/jopr.13628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 11/30/2022] [Accepted: 12/02/2022] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To evaluate the influence of post type and mechanical aging on compression force resistance, fracture pattern, and stress distribution in weakened roots. MATERIALS AND METHODS Bovine roots were endodontically treated and widened-and randomly divided into 8 groups (n = 10) according to post type (prefabricated glass fiber post and customized anatomic glass fiber post, milled glass fiber post-and-core, and milled polyetheretherketone post-and-core) and mechanical aging (without and with mechanical aging). Three hundred thousand cycles of mechanical fatigue were performed and compression force resistance (N) was analyzed by two-way ANOVA and Tukey test (α = 0.05). Fracture patterns were reported and stress distribution was analyzed by finite elements analysis. RESULTS There was a significant effect of post type (p = 0.032) and mechanical aging (p = 0.009), but no double interaction (p = 0.879). Higher values were recorded in the milled glass fiber and polyetheretherketone post-and-core groups compared to the prefabricated glass fiber post groups, and no significant difference was found among anatomic glass fiber post groups and other groups. Reparable fractures were predominant in the milled glass fiber and polyetheretherketone post-and-core groups. Prefabricated glass fiber posts and milled polyetheretherketone post-and-cores showed similar stress distribution. CONCLUSIONS Post type and mechanical aging influence the compression force resistance and fracture pattern of weakened roots. Milled glass fiber and polyetheretherketone post-and-cores exhibited higher compression force resistance and more reparable fractures compared to prefabricated glass fiber posts. Prefabricated glass fiber posts and milled polyetheretherketone post-and-cores showed similar stress distribution.
Collapse
Affiliation(s)
- Isabela G Gontijo
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Marcela A Ferretti
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Ricardo A Caldas
- Department of Prosthodontics, Federal University of Santa Catarina - UFSC, Florianópolis, SC, Brazil
| | - Vanessa G A Pecorari
- Department of Dental Materials, Paulista University - UNIP, São Paulo, SP, Brazil
| | - Fabiana M G França
- Department of Restorative Dentistry, São Leopoldo Mandic School of Dentistry - SLMANDIC, Campinas, SP, Brazil
| | - Lorena K N Oliveira
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Flávio H B Aguiar
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| |
Collapse
|
4
|
Rakotoaridina K, Delrieu J, Pages P, Vergé T, Nasr K, Canceill T. Evaluation of Poly(etheretherketone) Post's Mechanical Strength in Comparison with Three Metal-Free Biomaterials: An In Vitro Study. Polymers (Basel) 2023; 15:3583. [PMID: 37688208 PMCID: PMC10489626 DOI: 10.3390/polym15173583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 08/26/2023] [Accepted: 08/27/2023] [Indexed: 09/10/2023] Open
Abstract
The thinking about metallic replacement has begun in a global context of reducing metallic alloys' use in odontology. Among the materials proposed for their replacement, poly(etheretherketone) may present interesting properties, especially in removable dentures' frames. The purpose of this study is to evaluate fracture resistance of PEEK posts-and-cores compared to non-metallic CAD/CAM materials and fiber glass posts. Forty extracted maxillary central incisors were prepared to receive posts. Samples were divided into four groups depending on whether they had been reconstructed with LuxaCam® PEEK, Enamic®, Numerys GF® or LuxaPost®. Samples were submitted to an oblique compressive test and results were statistically analyzed with ANOVA and Student's tests (or non-parametric tests depending on the conditions). Glass fiber posts and Numerys GF® reveal a significantly higher fracture resistance than LuxaCam® PEEK and Enamic®. No exclusively dental fracture has been noted for the Enamic group, which significantly distinguishes these samples from the three other groups. In our study, it appears that the conception of posts and cores with hybrid ceramic never conducts to a unique tooth fracture. By weighting the results according to the materials used, our data, obtained for the first time on this type of PEEK block, cannot confirm the possibility of using PEEK for inlay-core conception, excepted for specific cases when the material is considered in a patient presenting allergies or systemic disease contraindicating resin or metal.
Collapse
Affiliation(s)
- Kévin Rakotoaridina
- Département Odontologie, Faculté de Santé, Hôpitaux de Toulouse, Université Paul Sabatier, 3 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
| | - Julien Delrieu
- Département Odontologie, Faculté de Santé, Hôpitaux de Toulouse, Université Paul Sabatier, 3 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
| | - Paul Pages
- Département Odontologie, Faculté de Santé, Hôpitaux de Toulouse, Université Paul Sabatier, 3 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
| | - Thierry Vergé
- Département Odontologie, Faculté de Santé, Hôpitaux de Toulouse, Université Paul Sabatier, 3 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
| | - Karim Nasr
- Département Odontologie, Faculté de Santé, Hôpitaux de Toulouse, Université Paul Sabatier, 3 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
| | - Thibault Canceill
- Département Odontologie, Faculté de Santé, Hôpitaux de Toulouse, Université Paul Sabatier, 3 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
- CNRS UMR 5085, INPT, Faculté de Pharmacie, CIRIMAT, Université Toulouse III Paul Sabatier, 35 Chemin des Maraichers, 31062 Toulouse Cedex 9, France
| |
Collapse
|
5
|
Kasem AT, Shams M, Tribst JPM. The Use of Polyetheretherketone (PEEK) as an Alternative Post and Core Material: Five-Year Follow-Up Report. Dent J (Basel) 2022; 10:237. [PMID: 36547053 PMCID: PMC9776542 DOI: 10.3390/dj10120237] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/05/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022] Open
Abstract
This clinical report demonstrated the use of polyetheretherketone (PEEK) for manufacturing of custom-made post and core in weakened endodontically treated central incisors. The PEEK structure was manufactured using computer-aided design/computer-aided manufacturing (CAD/CAM). The optimal fit of this custom-made endodontic post allowed a thinner cement layer; and removed the need to manufacture a core build-up. While supplementary clinical trials and in vitro studies are needed to totally elucidate the advantages and limitations of PEEK as an option for post and core manufacturing, this case report showed that it can be promising for a predictable and simplified treatment with five years of success.
Collapse
Affiliation(s)
- Ammar T. Kasem
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt
| | - Mahmoud Shams
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt
| | - João Paulo Mendes Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, The Netherlands
| |
Collapse
|