1
|
A Randomized Controlled Trial of Fibrin Glue to Prevent Bleeding After Gastric Endoscopic Submucosal Dissection. Am J Gastroenterol 2023; 118:892-899. [PMID: 36594814 DOI: 10.14309/ajg.0000000000002172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 12/20/2022] [Indexed: 01/04/2023]
Abstract
INTRODUCTION This study evaluated the efficacy of fibrin glue for preventing postendoscopic submucosal dissection (ESD) bleeding in high-risk patients for bleeding (expected iatrogenic ulcer size ≥40 mm or receiving antithrombotic therapy). METHODS A multicenter, open-label, randomized controlled trial was performed at 4 tertiary medical centers in South Korea between July 1, 2020, and June 22, 2022. Patients with gastric neoplasm and a high risk of post-ESD bleeding were enrolled and allocated at 1:1 to a control group (standard ESD) or a fibrin glue group (fibrin glue applied to iatrogenic ulcers after standard ESD). The primary outcome was overall bleeding events within 4 weeks. The secondary outcomes were acute bleeding (within 48 hours post-ESD) and delayed bleeding (48 hours to 4 weeks post-ESD). RESULTS In total, 254 patients were randomized, and 247 patients were included in the modified intention-to-treat population (125 patients in the fibrin glue group and 122 patients in the control group). Overall bleeding events occurred in 12.0% (15/125) of the fibrin glue group and 13.1% (16/122) of the control group ( P = 0.791). Acute bleeding events were significantly less common in the fibrin glue group than in the control group (1/125 vs 7/122, P = 0.034). Delayed bleeding events occurred in 11.2% (14/125) in the fibrin glue group and 7.3% (9/122) in the control group ( P = 0.301). DISCUSSION This trial failed to show a preventive effect of fibrin glue on overall post-ESD bleeding in high-risk patients. However, the secondary outcomes suggest a potential sealing effect of fibrin glue during the acute period.
Collapse
|
2
|
Wouters D, Cavallaro G, Jensen KK, East B, Jíšová B, Jorgensen LN, López-Cano M, Rodrigues-Gonçalves V, Stabilini C, Berrevoet F. The European Hernia Society Prehabilitation Project: A Systematic Review of Intra-Operative Prevention Strategies for Surgical Site Occurrences in Ventral Hernia Surgery. Front Surg 2022; 9:847279. [PMID: 35910469 PMCID: PMC9326087 DOI: 10.3389/fsurg.2022.847279] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Accepted: 06/06/2022] [Indexed: 11/29/2022] Open
Abstract
Background Ventral hernia repair is one of the most commonly performed surgical procedures worldwide. To reduce the risk of complications, pre- and intra-operative strategies have received increasing focus in recent years. To assess possible preventive surgical strategies, this European Hernia Society endorsed project was launched. The aim of this review was to evaluate the current literature focusing on pre- and intra-operative strategies for surgical site occurrences (SSO) and specifically surgical site infection (SSI) in ventral hernia repair. Methods A systematic review was conducted and reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Databases used were Pubmed and Web of Science. Original retrospective or prospective human adult studies describing at least one intra-operative intervention to reduce SSO after ventral hernia repair were considered eligible. Results From a total of 4775 results, a total of 18 papers were considered suitable after full text reading. Prehospital chlorhexidine gluconate (CHG) scrub appears to increase the risk of SSO in patients undergoing ventral hernia repair, while there is no association between any type of surgical hat worn and the incidence of postoperative wound events. Intraoperative measures as prophylactic negative pressure therapy, surgical drain placement and the use of quilt sutures seem beneficial for decreasing the incidence of SSO and/or SSI. No positive effect has been shown for antibiotic soaking of a synthetic mesh, nor for the use of fibrin sealants. Conclusion This review identified a limited amount of literature describing specific preventive measures and techniques during ventral hernia repair. An advantage of prophylactic negative pressure therapy in prevention of SSI was observed, but different tools to decrease SSIs and SSOs continuously further need our full attention to improve patient outcomes and to lower overall costs.
Collapse
Affiliation(s)
- D. Wouters
- Department for General and HPB Surgery and Liver Transplantation, University Hospital Gent, Gent, Belgium
| | - G. Cavallaro
- Department for General and HPB Surgery and Liver Transplantation, University Hospital Gent, Gent, Belgium
| | - Kristian K. Jensen
- Digestive Disease Center, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| | - B. East
- 3rd Department of Surgery and 1st Medical Faculty of Charles University, Motol University Hospital, Prague, Czech Republic
| | - B. Jíšová
- 3rd Department of Surgery and 1st Medical Faculty of Charles University, Motol University Hospital, Prague, Czech Republic
| | - L. N. Jorgensen
- Digestive Disease Center, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| | - M. López-Cano
- Abdominal Wall Surgery Unit, Department of General Surgery, Hospital Universitari Vall d’Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - V. Rodrigues-Gonçalves
- Abdominal Wall Surgery Unit, Department of General Surgery, Hospital Universitari Vall d’Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - C. Stabilini
- Department of Surgery, University of Genoa, Genoa, Italy
- European Hernia Society, Ospedale Policlinico San Martino IRCCS, Genoa, Italy
| | - F. Berrevoet
- Department for General and HPB Surgery and Liver Transplantation, University Hospital Gent, Gent, Belgium
- Correspondence: Frederik Berrevoet
| |
Collapse
|
3
|
Kapoulas S, Papalois A, Papadakis G, Tsoulfas G, Christoforidis E, Papaziogas B, Schizas D, Chatzimavroudis G. Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine. Hernia 2022; 26:567-579. [PMID: 33400026 DOI: 10.1007/s10029-020-02352-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Accepted: 12/02/2020] [Indexed: 02/05/2023]
Abstract
PURPOSE Choice of the best possible fixation system in terms of safety and effectiveness for intraperitoneal mesh placement in hernia surgery remains controversial. The aim of the present study was to compare the performance of four fixation systems in a swine model of intraperitoneal mesh fixation. METHODS Fourteen Landrace swine were utilized in the study. The experiment included two stages. Initially, four pieces of mesh (Ventralight ™ ST) sizing 10 × 5 cm were placed and fixed intraperitoneally to reinforce 4 small full thickness abdominal wall defects created with diathermy. These defects were repaired primarily with absorbable suture before mesh implantation. Each mesh was anchored with a different tack device between Absorbatack™, Protack™, Capsure™, or Optifix™. The second stage took place after 60 days and included euthanasia, laparoscopy, and laparotomy via U-shaped incision to obtain the measurements for the outcome parameters. The primary endpoint of the study was to compare the peel strength of the compound tack/mesh from the abdominal wall. Secondary parameters were the extent and quality of visceral adhesions to the mesh, the degree of mesh shrinkage and the histological response around the tacks. RESULTS Thirteen out of 14 animals survived the experiment and 10 were included in the final analysis. Capsure™ tacks had higher peel strength when compared to Absorbatack™ (p = 0.028); Protack™ (p = 0.043); and Optifix™ (p = 0.009). No significant differences were noted regarding the extent of visceral adhesions (Friedman's test p value 0.854), the adhesion quality (Friedman's test p value 0.506), or the mesh shrinkage (Friedman's test p value = 0.827). Four out of the ten animals developed no adhesions at all 2 months after implantation. CONCLUSION Capsure™ fixation system provided higher peel strength that the other tested devices in our swine model of intraperitoneal mesh fixation. Our findings generate the hypothesis that this type of fixation may be superior in a clinical setting. Clinical trials with long-term follow-up are required to assess the safety and efficacy of mesh fixation systems in hernia surgery.
Collapse
Affiliation(s)
- S Kapoulas
- 2nd Department of Surgery, Aristotle University of Thessaloniki, G. Gennimatas General Hospital, Thessaloniki, Greece.
- Department of Upper Gastrointestinal and Bariatric Surgery, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
- , Flat 318, Centenary Plaza, 18 Holliday Street, Birmingham, B11TW, UK.
| | - A Papalois
- ELPEN Pharmaceuticals Research and Experimental Centre, Pikermi, Greece
| | - G Papadakis
- Department of Renal Transplant and Access Surgery, Guy's and St. Thomas' NHS Foundation Trust, London, UK
| | - G Tsoulfas
- 1st Department of Surgery, Aristotle University of Thessaloniki, Papageorgiou General Hospital, Thessaloniki, Greece
| | - E Christoforidis
- 2nd Department of Surgery, Aristotle University of Thessaloniki, G. Gennimatas General Hospital, Thessaloniki, Greece
| | - B Papaziogas
- 2nd Department of Surgery, Aristotle University of Thessaloniki, G. Gennimatas General Hospital, Thessaloniki, Greece
| | - D Schizas
- 1st Department of Surgery, National and Kapodistrian University of Athens, Laikon General Hospital, Athens, Greece
| | - G Chatzimavroudis
- 2nd Department of Surgery, Aristotle University of Thessaloniki, G. Gennimatas General Hospital, Thessaloniki, Greece
| |
Collapse
|
4
|
Roberts IV, Bukhary D, Valdivieso CYL, Tirelli N. Fibrin Matrices as (Injectable) Biomaterials: Formation, Clinical Use, and Molecular Engineering. Macromol Biosci 2019; 20:e1900283. [PMID: 31769933 DOI: 10.1002/mabi.201900283] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 10/14/2019] [Indexed: 12/19/2022]
Abstract
This review focuses on fibrin, starting from biological mechanisms (its production from fibrinogen and its enzymatic degradation), through its use as a medical device and as a biomaterial, and finally discussing the techniques used to add biological functions and/or improve its mechanical performance through its molecular engineering. Fibrin is a material of biological (human, and even patient's own) origin, injectable, adhesive, and remodellable by cells; further, it is nature's most common choice for an in situ forming, provisional matrix. Its widespread use in the clinic and in research is therefore completely unsurprising. There are, however, areas where its biomedical performance can be improved, namely achieving a better control over mechanical properties (and possibly higher modulus), slowing down degradation or incorporating cell-instructive functions (e.g., controlled delivery of growth factors). The authors here specifically review the efforts made in the last 20 years to achieve these aims via biomimetic reactions or self-assembly, as much via formation of hybrid materials.
Collapse
Affiliation(s)
- Iwan Vaughan Roberts
- Division of Pharmacy and Optometry, School of Health Science, University of Manchester, Oxford Road, Manchester, M13 9PT, UK
| | - Deena Bukhary
- Division of Pharmacy and Optometry, School of Health Science, University of Manchester, Oxford Road, Manchester, M13 9PT, UK.,Department of Pharmaceutical Science, Faculty of Pharmacy, Umm Al-Qura University, Makkah, 21955, Saudi Arabia
| | | | - Nicola Tirelli
- Division of Pharmacy and Optometry, School of Health Science, University of Manchester, Oxford Road, Manchester, M13 9PT, UK.,Laboratory of Polymers and Biomaterials, Fondazione Istituto Italiano di Tecnologia, via Morego 30, 16163, Genova, Italy
| |
Collapse
|
5
|
Retromuscular Mesh Repair Using Fibrin Glue: Early Outcomes and Cost-effectiveness of an Evolving Technique. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2019; 7:e2184. [PMID: 31321182 PMCID: PMC6554171 DOI: 10.1097/gox.0000000000002184] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 01/15/2019] [Indexed: 12/18/2022]
Abstract
Background Retromuscular hernia repairs (RHRs) decrease hernia recurrence and surgical site infections but can cause significant pain. We aimed to determine if pain and postoperative outcomes differed when comparing suture fixation (SF) of mesh to fibrin glue fixation (FGF). Methods Patients undergoing RHR (n = 87) between December 1, 2015 and December 31, 2017 were retrospectively identified. Patients received SF of mesh (n = 59, 67.8%) before the senior author changing his technique to FGF (n = 28, 32.2%). These 2 cohorts were matched (age, body mass index, number of prior repairs, mesh type, defect size, and wound class). Outcomes were analyzed using a matched pairs design with multivariable linear regression. Results Two matched groups (21 FGF and 21 SF) were analyzed (45.2% female, average age 56 years, average body mass index 34.7 kg/m2, and average defect size 330 cm2). Statistical significance was observed for FGF compared with SF: length of stay (3.7 versus 7.1 days, P = 0.032), time with a drain (17.2 versus 27.5 days, P = 0.012), 30-day postoperative visits (2 versus 3, P = 0.003), pain scores (5.2 versus 3.1, P = 0.019) and activity within the first 24 hours (walking versus sitting, P = 0.002). Operative time decreased by 23.1 minutes (P = 0.352) and postoperative narcotic represcription (3 versus. 8 patients, p=0.147) also decreased. Average cost for patients receiving SF was $36,152 compared to $21,782 for FGF (P = 0.035). Conclusions Sutureless RHR using FGF may result in decreased pain when compared with a matched cohort receiving SF, translating to enhanced recovery time, shortened hospital stay, and decreased costs.
Collapse
|
6
|
Effect of fixation devices on postoperative pain after laparoscopic ventral hernia repair: a randomized clinical trial of permanent tacks, absorbable tacks, and synthetic glue. Langenbecks Arch Surg 2018; 403:529-537. [DOI: 10.1007/s00423-018-1676-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2017] [Accepted: 04/16/2018] [Indexed: 10/16/2022]
|
7
|
Edwards SJ, Crawford F, van Velthoven MH, Berardi A, Osei-Assibey G, Bacelar M, Salih F, Wakefield V. The use of fibrin sealant during non-emergency surgery: a systematic review of evidence of benefits and harms. Health Technol Assess 2018; 20:1-224. [PMID: 28051764 DOI: 10.3310/hta20940] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Fibrin sealants are used in different types of surgery to prevent the accumulation of post-operative fluid (seroma) or blood (haematoma) or to arrest haemorrhage (bleeding). However, there is uncertainty around the benefits and harms of fibrin sealant use. OBJECTIVES To systematically review the evidence on the benefits and harms of fibrin sealants in non-emergency surgery in adults. DATA SOURCES Electronic databases [MEDLINE, EMBASE and The Cochrane Library (including the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects, the Health Technology Assessment database and the Cochrane Central Register of Controlled Trials)] were searched from inception to May 2015. The websites of regulatory bodies (the Medicines and Healthcare products Regulatory Agency, the European Medicines Agency and the Food and Drug Administration) were also searched to identify evidence of harms. REVIEW METHODS This review included randomised controlled trials (RCTs) and observational studies using any type of fibrin sealant compared with standard care in non-emergency surgery in adults. The primary outcome was risk of developing seroma and haematoma. Only RCTs were used to inform clinical effectiveness and both RCTs and observational studies were used for the assessment of harms related to the use of fibrin sealant. Two reviewers independently screened all titles and abstracts to identify potentially relevant studies. Data extraction was undertaken by one reviewer and validated by a second. The quality of included studies was assessed independently by two reviewers using the Cochrane Collaboration risk-of-bias tool for RCTs and the Centre for Reviews and Dissemination guidance for adverse events for observational studies. A fixed-effects model was used for meta-analysis. RESULTS We included 186 RCTs and eight observational studies across 14 surgical specialties and five reports from the regulatory bodies. Most RCTs were judged to be at an unclear risk of bias. Adverse events were inappropriately reported in observational studies. Meta-analysis across non-emergency surgical specialties did not show a statistically significant difference in the risk of seroma for fibrin sealants versus standard care in 32 RCTs analysed [n = 3472, odds ratio (OR) 0.84, 95% confidence interval (CI) 0.68 to 1.04; p = 0.13; I2 = 12.7%], but a statistically significant benefit was found on haematoma development in 24 RCTs (n = 2403, OR 0.62, 95% CI 0.44 to 0.86; p = 0.01; I2 = 0%). Adverse events related to fibrin sealant use were reported in 10 RCTs and eight observational studies across surgical specialties, and 22 RCTs explicitly stated that there were no adverse events. One RCT reported a single death but no other study reported mortality or any serious adverse events. Five regulatory body reports noted death from air emboli associated with fibrin sprays. LIMITATIONS It was not possible to provide a detailed evaluation of individual RCTs in their specific contexts because of the limited resources that were available for this research. In addition, the number of RCTs that were identified made it impractical to conduct independent data extraction by two reviewers in the time available. CONCLUSIONS The effectiveness of fibrin sealants does not appear to vary according to surgical procedures with regard to reducing the risk of seroma or haematoma. Surgeons should note the potential risk of gas embolism if spray application of fibrin sealants is used and not to exceed the recommended pressure and spraying distance. Future research should be carried out in surgery specialties for which only limited data were found, including neurological, gynaecological, oral and maxillofacial, urology, colorectal and orthopaedics surgery (for any outcome); breast surgery and upper gastrointestinal (development of haematoma); and cardiothoracic heart or lung surgery (reoperation rates). In addition, studies need to use adequate sample sizes, to blind participants and outcome assessors, and to follow reporting guidelines. STUDY REGISTRATION This study is registered as PROSPERO CRD42015020710. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
|
8
|
Abstract
INTRODUCTION Worldwide, more than 20 million patients undergo groin hernia repair annually. The many different approaches, treatment indications and a significant array of techniques for groin hernia repair warrant guidelines to standardize care, minimize complications, and improve results. The main goal of these guidelines is to improve patient outcomes, specifically to decrease recurrence rates and reduce chronic pain, the most frequent problems following groin hernia repair. They have been endorsed by all five continental hernia societies, the International Endo Hernia Society and the European Association for Endoscopic Surgery. METHODS An expert group of international surgeons (the HerniaSurge Group) and one anesthesiologist pain expert was formed. The group consisted of members from all continents with specific experience in hernia-related research. Care was taken to include surgeons who perform different types of repair and had preferably performed research on groin hernia surgery. During the Group's first meeting, evidence-based medicine (EBM) training occurred and 166 key questions (KQ) were formulated. EBM rules were followed in complete literature searches (including a complete search by The Dutch Cochrane database) to January 1, 2015 and to July 1, 2015 for level 1 publications. The articles were scored by teams of two or three according to Oxford, SIGN and Grade methodologies. During five 2-day meetings, results were discussed with the working group members leading to 136 statements and 88 recommendations. Recommendations were graded as "strong" (recommendations) or "weak" (suggestions) and by consensus in some cases upgraded. In the Results and summary section below, the term "should" refers to a recommendation. The AGREE II instrument was used to validate the guidelines. An external review was performed by three international experts. They recommended the guidelines with high scores. The risk factors for inguinal hernia (IH) include: family history, previous contra-lateral hernia, male gender, age, abnormal collagen metabolism, prostatectomy, and low body mass index. Peri-operative risk factors for recurrence include poor surgical techniques, low surgical volumes, surgical inexperience and local anesthesia. These should be considered when treating IH patients. IH diagnosis can be confirmed by physical examination alone in the vast majority of patients with appropriate signs and symptoms. Rarely, ultrasound is necessary. Less commonly still, a dynamic MRI or CT scan or herniography may be needed. The EHS classification system is suggested to stratify IH patients for tailored treatment, research and audit. Symptomatic groin hernias should be treated surgically. Asymptomatic or minimally symptomatic male IH patients may be managed with "watchful waiting" since their risk of hernia-related emergencies is low. The majority of these individuals will eventually require surgery; therefore, surgical risks and the watchful waiting strategy should be discussed with patients. Surgical treatment should be tailored to the surgeon's expertise, patient- and hernia-related characteristics and local/national resources. Furthermore, patient health-related, life style and social factors should all influence the shared decision-making process leading up to hernia management. Mesh repair is recommended as first choice, either by an open procedure or a laparo-endoscopic repair technique. One standard repair technique for all groin hernias does not exist. It is recommended that surgeons/surgical services provide both anterior and posterior approach options. Lichtenstein and laparo-endoscopic repair are best evaluated. Many other techniques need further evaluation. Provided that resources and expertise are available, laparo-endoscopic techniques have faster recovery times, lower chronic pain risk and are cost effective. There is discussion concerning laparo-endoscopic management of potential bilateral hernias (occult hernia issue). After patient consent, during TAPP, the contra-lateral side should be inspected. This is not suggested during unilateral TEP repair. After appropriate discussions with patients concerning results tissue repair (first choice is the Shouldice technique) can be offered. Day surgery is recommended for the majority of groin hernia repair provided aftercare is organized. Surgeons should be aware of the intrinsic characteristics of the meshes they use. Use of so-called low-weight mesh may have slight short-term benefits like reduced postoperative pain and shorter convalescence, but are not associated with better longer-term outcomes like recurrence and chronic pain. Mesh selection on weight alone is not recommended. The incidence of erosion seems higher with plug versus flat mesh. It is suggested not to use plug repair techniques. The use of other implants to replace the standard flat mesh in the Lichtenstein technique is currently not recommended. In almost all cases, mesh fixation in TEP is unnecessary. In both TEP and TAPP it is recommended to fix mesh in M3 hernias (large medial) to reduce recurrence risk. Antibiotic prophylaxis in average-risk patients in low-risk environments is not recommended in open surgery. In laparo-endoscopic repair it is never recommended. Local anesthesia in open repair has many advantages, and its use is recommended provided the surgeon is experienced in this technique. General anesthesia is suggested over regional in patients aged 65 and older as it might be associated with fewer complications like myocardial infarction, pneumonia and thromboembolism. Perioperative field blocks and/or subfascial/subcutaneous infiltrations are recommended in all cases of open repair. Patients are recommended to resume normal activities without restrictions as soon as they feel comfortable. Provided expertise is available, it is suggested that women with groin hernias undergo laparo-endoscopic repair in order to decrease the risk of chronic pain and avoid missing a femoral hernia. Watchful waiting is suggested in pregnant women as groin swelling most often consists of self-limited round ligament varicosities. Timely mesh repair by a laparo-endoscopic approach is suggested for femoral hernias provided expertise is available. All complications of groin hernia management are discussed in an extensive chapter on the topic. Overall, the incidence of clinically significant chronic pain is in the 10-12% range, decreasing over time. Debilitating chronic pain affecting normal daily activities or work ranges from 0.5 to 6%. Chronic postoperative inguinal pain (CPIP) is defined as bothersome moderate pain impacting daily activities lasting at least 3 months postoperatively and decreasing over time. CPIP risk factors include: young age, female gender, high preoperative pain, early high postoperative pain, recurrent hernia and open repair. For CPIP the focus should be on nerve recognition in open surgery and, in selected cases, prophylactic pragmatic nerve resection (planned resection is not suggested). It is suggested that CPIP management be performed by multi-disciplinary teams. It is also suggested that CPIP be managed by a combination of pharmacological and interventional measures and, if this is unsuccessful, followed by, in selected cases (triple) neurectomy and (in selected cases) mesh removal. For recurrent hernia after anterior repair, posterior repair is recommended. If recurrence occurs after a posterior repair, an anterior repair is recommended. After a failed anterior and posterior approach, management by a specialist hernia surgeon is recommended. Risk factors for hernia incarceration/strangulation include: female gender, femoral hernia and a history of hospitalization related to groin hernia. It is suggested that treatment of emergencies be tailored according to patient- and hernia-related factors, local expertise and resources. Learning curves vary between different techniques. Probably about 100 supervised laparo-endoscopic repairs are needed to achieve the same results as open mesh surgery like Lichtenstein. It is suggested that case load per surgeon is more important than center volume. It is recommended that minimum requirements be developed to certify individuals as expert hernia surgeon. The same is true for the designation "Hernia Center". From a cost-effectiveness perspective, day-case laparoscopic IH repair with minimal use of disposables is recommended. The development and implementation of national groin hernia registries in every country (or region, in the case of small country populations) is suggested. They should include patient follow-up data and account for local healthcare structures. A dissemination and implementation plan of the guidelines will be developed by global (HerniaSurge), regional (international societies) and local (national chapters) initiatives through internet websites, social media and smartphone apps. An overarching plan to improve access to safe IH surgery in low-resource settings (LRSs) is needed. It is suggested that this plan contains simple guidelines and a sustainability strategy, independent of international aid. It is suggested that in LRSs the focus be on performing high-volume Lichtenstein repair under local anesthesia using low-cost mesh. Three chapters discuss future research, guidelines for general practitioners and guidelines for patients. CONCLUSIONS The HerniaSurge Group has developed these extensive and inclusive guidelines for the management of adult groin hernia patients. It is hoped that they will lead to better outcomes for groin hernia patients wherever they live. More knowledge, better training, national audit and specialization in groin hernia management will standardize care for these patients, lead to more effective and efficient healthcare and provide direction for future research.
Collapse
|
9
|
Harsløf S, Zinther N, Harsløf T, Danielsen C, Wara P, Friis-Andersen H. Polypropelene-mesh properties and type of anchoring do not influence strength of parietal ingrowth. Langenbecks Arch Surg 2017; 402:1047-1054. [DOI: 10.1007/s00423-017-1602-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Accepted: 07/06/2017] [Indexed: 10/19/2022]
|
10
|
Höhn P, Buchholz M, Majchrzak B, Uhl W, Braumann C, Chromik AM. The Physiological Incubation Biosimulator (PIBS): An Improved Ex Vivo Experimental Setup for the Mechanical Stability of Biological Sealants in Surgical Procedures. Surg Innov 2017; 24:214-222. [PMID: 28492352 DOI: 10.1177/1553350617697181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Tissue-bound fibrin sealants are used in a wide array of surgical procedures. The microenvironmental interaction between sealant and application site is often poorly evaluated due to a lack of suitable experimental models. METHODS A physiological incubation biosimulator (PIBS) was developed to test biological sealants in an ex vivo setup under physiological conditions comparable to the microenvironment at application site (temperature, humidity, pressure). PIBS was validated by a study on the effectiveness of TachoSil for leak closure at pancreatic resection sites. Defined defects in a thoracic membrane of porcine origin were sealed by TachoSil. Integrity of the sealing was tested in the presence of active pancreatic fluid over 60 minutes. Heat-inactivated pancreatic fluid and electrolyte solution served as controls. The time to leakage was recorded and experimental groups were analyzed by Kaplan-Meier analysis. RESULTS PIBS produced reliable results. TachoSil lead to a leakage rate of 96% after incubation with active pancreatic fluid (p = 34), which was significantly higher compared with heat-inactivated pancreatic fluid (p = 34, 52%) or electrolyte solution (p = 20, 19%). CONCLUSION PIBS is an effective tool to evaluate microenvironmental effects on the adhesive strength of biomaterials. Tissue sealing effect of TachoSil is diminished in a "pancreatic" microenvironment rich with pancreatic enzymes. Our results might therefore explain the reason of the findings of randomized controlled trials recently published on this subject.
Collapse
Affiliation(s)
- Philipp Höhn
- 1 St Josef-Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Marie Buchholz
- 1 St Josef-Hospital, Ruhr-University Bochum, Bochum, Germany
| | | | - Waldemar Uhl
- 1 St Josef-Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Chris Braumann
- 1 St Josef-Hospital, Ruhr-University Bochum, Bochum, Germany
| | | |
Collapse
|
11
|
Hoyuela C, Juvany M, Carvajal F, Veres A, Troyano D, Trias M, Martrat A, Ardid J, Obiols J, López-Cano M. Randomized clinical trial of mesh fixation with glue or sutures for Lichtenstein hernia repair. Br J Surg 2017; 104:688-694. [PMID: 28218406 DOI: 10.1002/bjs.10488] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2016] [Revised: 09/20/2016] [Accepted: 12/09/2016] [Indexed: 11/10/2022]
Abstract
BACKGROUND Pain is the most likely reason for delay in resuming normal activities after groin hernia repair. The primary aim of this study was to determine whether the use of glue to fix the mesh instead of sutures reduced acute postoperative pain after inguinal hernia repair. Secondary objectives were to compare postoperative complications, chronic pain and early recurrence rates during 1-year follow-up. METHODS Some 370 patients who underwent Lichtenstein hernia repair were randomized to receive either glue (Histoacryl®) or non-absorbable polypropylene sutures for fixation of lightweight polypropylene mesh. Postoperative complications, pain and recurrence were evaluated by an independent blinded observer. RESULTS Postoperative pain at 8 h, 24 h, 7 days and 30 days was less when glue was used instead of sutures for all measures (P < 0·001). The operation was significantly quicker using glue (mean(s.d.) 35·3(8·7) min versus 39·9(11·1) min for sutures; P < 0·001). There were no significant differences between the groups in terms of postoperative complications, chronic pain and early recurrence at 1-year follow-up. CONCLUSION Atraumatic mesh fixation with glue was quicker and resulted in less acute postoperative pain than sutures for Lichtenstein hernia repair. Registration number: NCT02632097 (http://www.clinicaltrials.gov).
Collapse
Affiliation(s)
- C Hoyuela
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - M Juvany
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - F Carvajal
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - A Veres
- Department of Surgery, Hospital de la Cerdanya, Puigcerdà, Spain
| | - D Troyano
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - M Trias
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - A Martrat
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - J Ardid
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - J Obiols
- Department of General and Digestive Surgery, Hospital Platón, Barcelona, Spain
| | - M López-Cano
- Department of General Surgery, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
12
|
Sun P, Cheng X, Deng S, Hu Q, Sun Y, Zheng Q. Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty. Cochrane Database Syst Rev 2017; 2:CD010814. [PMID: 28170080 PMCID: PMC6464532 DOI: 10.1002/14651858.cd010814.pub2] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Chronic pain following mesh-based inguinal hernia repair is frequently reported, and has a significant impact on quality of life. Whether mesh fixation with glue can reduce chronic pain without increasing the recurrence rate is still controversial. OBJECTIVES To determine whether tissue adhesives can reduce postoperative complications, especially chronic pain, with no increase in recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. SEARCH METHODS We searched the following electronic databases with no language restrictions: the Cochrane Central Register of Controlled Trials (CENTRAL; issue 4, 2016) in the Cochrane Library (searched 11 May 2016), MEDLINE Ovid (1986 to 11 May 2016), Embase Ovid (1986 to 11 May 2016), Science Citation Index (Web of Science) (1986 to 11 May 2016), CBM (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), VIP (a full-text database in China), Wanfang databases. We also checked reference lists of identified papers (included studies and relevant reviews). SELECTION CRITERIA We included all randomised and quasi-randomised controlled trials comparing glue versus sutures for mesh fixation in Lichtenstein hernia repair. Cluster-RCTs were also eligible. DATA COLLECTION AND ANALYSIS Two review authors extracted data and assessed the risk of bias independently. Dichotomous outcomes were expressed as odds ratio (OR) with 95% confidence intervals (CI). Continuous outcomes were expressed as mean differences (MD) with 95% CIs. MAIN RESULTS Twelve trials with a total of 1932 participants were included in this review. The overall postoperative chronic pain in the glue group was reduced by 37% (OR 0.63, 95% CI 0.44 to 0.91; 10 studies, 1418 participants, low-quality evidence) compared with the suture group. However, the results changed when we conducted subgroup analysis with regard to the type of mesh. Subgroup analysis of included studies using lightweight mesh showed the reduction of chronic pain was less profound and insignificant (OR 0.77, 95% CI 0.50 to 1.17). Subgroup analysis of included studies using heavyweight mesh resulted in a significant benefit from the fixation with glue (OR 0.38, 95% CI 0.17 to 0.82).Hernia recurrence was similar between the two groups (OR 1.44, 95% CI 0.63 to 3.28; 12 studies, 1932 participants, low-quality evidence). Fixation with glue was superior to suture regarding duration of the operation (MD -3.13, 95% CI -4.48 to -1.78; 9 studies, 1790 participants, low-quality evidence); haematoma (OR 0.52, 95% CI 0.31 to 0.86; 10 studies, 1384 participants, moderate-quality evidence); and recovery time to daily activities (MD -1.26, 95% CI -1.89 to -0.63; 3 studies, 403 participants, low-quality evidence).We also investigated adverse events. There were no significant differences between the two groups. For superficial wound infection pooled analyses showed OR 1.23, 95% CI 0.37 to 4.11; 7 studies, 763 participants (low-quality evidence); for mesh/deep infection OR 0.67, 95% CI 0.16 to 2.83; 8 studies, 1393 participants (low-quality evidence). Furthermore, we investigated seroma (a postoperative swelling caused by fluid) (OR 0.83, 95% CI 0.51 to 1.33); and persisting numbness (OR 0.81, 95% CI 0.57 to 1.14).Finally, six trials involving 1009 participants reported postoperative length of stay, resulting in non-significant difference between the two groups (MD -0.12, 95% CI: -0.35 to 0.10)Due to the lack of data, it was impossible to draw any distinction between synthetic glue and biological glue.Eight out of 12 trials showed high risk of bias in at least one of the investigated domains. Two studies were quasi-randomised controlled trials and the allocation sequence of one trial was not concealed. Nearly half of the included trials either did not provide adequate information or had high risk of bias regarding blinding processes. The risk of bias for incomplete outcome data of all the included studies varied from low to high risk of bias. Two trials did not report on some important outcomes. One study was funded by the manufacturer producing the fibrin sealant. Therefore, according to the 'Summary of findings' tables, the quality of the evidence (GRADE) for the outcomes is moderate to low. AUTHORS' CONCLUSIONS Based on the short-term results, glue may reduce postoperative chronic pain and not simultaneously increase the recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. Glue may therefore be a sensible alternative to suture for mesh fixation in Lichtenstein repair. Larger trials with longer follow-up and high quality are warranted. The difference between synthetic glue and biological glue should also be assessed in the future.
Collapse
Affiliation(s)
- Ping Sun
- Union Hospital, Tongji Medical College, Huazhong University of Science and TechnologyDepartment of Hepatobiliary Surgery1277 Jiefang Avenue.WuhanHubei ProvinceChina430022
| | - Xiang Cheng
- Union Hospital, Tongji Medical College, Huazhong University of Science and TechnologyDepartment of Hepatobiliary Surgery1277 Jiefang Avenue.WuhanHubei ProvinceChina430022
| | - Shichang Deng
- Union Hospital West Campus, Tongji Medical College, Huazhong University of Science and TechnologyDepartment of Gastrointestinal Surgery58 Shenlong Avenue.WuhanHubeiChina430056
| | - Qinggang Hu
- Union Hospital, Tongji Medical College, Huazhong University of Science and TechnologyDepartment of Hepatobiliary Surgery1277 Jiefang Avenue.WuhanHubei ProvinceChina430022
| | - Yi Sun
- Huazhong University of Science and TechnologySchool of Public Health, Tongji Medical CollegeHangkong Street, No. 13WuhanHubei ProvinceChina430030
| | - Qichang Zheng
- Union Hospital, Tongji Medical College, Huazhong University of Science and TechnologyDepartment of Hepatobiliary Surgery1277 Jiefang Avenue.WuhanHubei ProvinceChina430022
| | | |
Collapse
|
13
|
Azoury SC, Rodriguez-Unda N, Soares KC, Hicks CW, Baltodano PA, Poruk KE, Hu QL, Cooney CM, Cornell P, Burce K, Eckhauser FE. The effect of TISSEEL fibrin sealant on seroma formation following complex abdominal wall hernia repair: a single institutional review and derived cost analysis. Hernia 2015; 19:935-42. [DOI: 10.1007/s10029-015-1403-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Accepted: 06/26/2015] [Indexed: 10/23/2022]
|
14
|
Liu H, Zheng X, Gu Y, Guo S. A meta-analysis examining the use of fibrin glue mesh fixation versus suture mesh fixation in open inguinal hernia repair. Dig Surg 2015; 31:444-51. [PMID: 25592242 DOI: 10.1159/000370249] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Accepted: 11/30/2014] [Indexed: 12/10/2022]
Abstract
BACKGROUND The aim of this study was to systematically analyze the randomized trials comparing fibrin glue mesh fixation with suture mesh fixation in open inguinal hernia repair. METHODS Information was collected from a literature search using PubMed, Springer, Cochrane Library database and reference lists. The methodological quality of included publications was evaluated. Statistical analysis was performed using Review Manager Version 5.2.5 software. RESULTS Nine articles were identified for inclusion: four randomized controlled trials (RCTs) and five prospective observational clinical studies. All the trials were considered to be of fair quality. The results showed that there was a lower incidence of chronic pain (RR 0.42, 95% CI 0.22-0.79, I(2) 11%; p < 0.01), and hematoma/seroma (RR 0.43, 95% CI 0.21-0.87, I(2) 0%; p < 0.05) in the fibrin glue mesh fixation group. However, the results of meta-analysis revealed that the incidence of recurrence or urinary problems between the two procedures were similar. CONCLUSIONS During the 6-15 months follow-up, fibrin glue mesh fixation is a feasible alternative for mesh fixation with sutures in open inguinal hernia repair. However, the poor quality of the included trials limits the evidence; rigorously designed trials are warranted to confirm this conclusion.
Collapse
Affiliation(s)
- Huihui Liu
- Department of General Surgery, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | | | | | | |
Collapse
|
15
|
Odobasic A, Krdzalic G, Hodzic M, Hasukic S, Sehanovic A, Odobasic A. The role of fibrin glue polypropylene mesh fixation in open inguinal hernia repair. Med Arch 2014; 68:90-3. [PMID: 24937929 PMCID: PMC4272507 DOI: 10.5455/medarh.2014.68.90-93] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
UNLABELLED The aim of this study was to compare two methods of polypropylene mesh fixation for inguinal hernia repair according to Lichtenstein using fibrin glue and suture fixation. MATERIAL AND METHODS The study included 60 patients with unilateral inguinal hernia, divided into two groups of 30 patients--Suture fixation and fibrin glue fixation. All patients were analyzed according to: age, gender, body mass index (BMI), indication for surgery--the type, localization and size of the hernia, preoperative level of pain and the type of surgery. Overall postoperative complications and the patient's ability to return to regular activities were followed for 3 months. RESULTS AND DISCUSSION Statistically significant difference in the duration of surgery, pain intensity and complications (p < 0.05) were verified between method A, the group of patients whose inguinal hernia was repaired using polypropylene mesh-fibrin glue and method B, where inguinal hernia was repaired with polypropylene mesh using suture fixation. Given the clinical research, this systematic review of existing results on the comparative effectiveness, will help in making important medical decisions about options for surgical treatment of inguinal hernia. CONCLUSIONS The results of this study may impact decision making process for recommendations of methods of treatment by professional associations, making appropriate decisions on hospital procurement of materials, as well as coverage of health funds and insurance.
Collapse
Affiliation(s)
- Amer Odobasic
- Surgery Clinic, University Clinical Center Tuzla, Tuzla, Bosnia and Herzegovina
- Corresponding author: Amer Odobasic, MD. Surgery Clinic, University Clinical Center Tuzla. Trnovac bb, 75000 Tuzla. Bosnia and Herzegovina. Phone: ++ 387 61 14 84 94. E-mail:
| | - Goran Krdzalic
- Surgery Clinic, University Clinical Center Tuzla, Tuzla, Bosnia and Herzegovina
| | - Mirsad Hodzic
- Neurosurgery Clinic, University Clinical Center Tuzla, Tuzla, Bosnia and Herzegovina
| | - Sefik Hasukic
- Surgery Clinic, University Clinical Center Tuzla, Tuzla, Bosnia and Herzegovina
| | - Aida Sehanovic
- Neurology Clinic, University Clinical Center Tuzla, Tuzla, Bosnia and Herzegovina
| | - Ademir Odobasic
- Surgery Clinic, University Clinical Center Tuzla, Tuzla, Bosnia and Herzegovina
| |
Collapse
|
16
|
Sanders DL, Waydia S. A systematic review of randomised control trials assessing mesh fixation in open inguinal hernia repair. Hernia 2013; 18:165-76. [PMID: 23649403 DOI: 10.1007/s10029-013-1093-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2012] [Accepted: 04/26/2013] [Indexed: 12/24/2022]
Abstract
PURPOSE The technique for fixation of mesh has been attributed to adverse patient and surgical outcomes. Although this has been the subject of vigorous debate in laparoscopic hernia repair, the several methods of fixation in open, anterior inguinal hernia repair have seldom been reviewed. The aim of this systematic review was to determine whether there is any difference in patient-based (recurrence, post-operative pain, SSI, quality of life) or surgical outcomes (operative time, length of operative stay) with different fixation methods in open anterior inguinal hernioplasty. METHODS A literature search was performed in PubMed, EMBASE and the Cochrane Library databases. Randomised clinical trials assessing more than one method of mesh fixation (or fixation versus no fixation) of mesh in adults (>18 years) in open, anterior inguinal hernia repair, with a minimum of 6-month follow-up and including at least one of the primary outcome measures (recurrence, chronic pain, surgical site infection) were included in the review. Secondary outcomes analysed included post-operative pain (within the first week), quality of life, operative time and length of hospital stay. RESULTS Twelve randomised clinical trials, which included 1,992 primary inguinal hernia repairs, were eligible for inclusion. Four studies compared n-butyl-2 cyanoacrylate (NB2C) glues to sutures, two compared self-fixing meshes to sutures, four compared fibrin sealant to sutures, one compared tacks to sutures, and one compared absorbable sutures to non-absorbable sutures. The majority of the trials were rated as low or very low-quality studies. There was no significant difference in recurrence or surgical site infection rates between fixation methods. There was significant heterogeneity in the measurement of chronic pain. Three trials reported significantly lower rates of chronic pain with fibrin sealant or glue fixation compared to sutures. A further three studies reported lower pain rates within the first week with non-suture fixation techniques compared to suture fixation. A significant reduction in operative time, ranging form 6 to 17.9 min with non-suture fixation, was reported in five of the studies. Although infrequently measured, there were no significant differences in length of hospital stay or quality of life between fixation methods. CONCLUSIONS There is insufficient evidence to promote fibrin sealant, self-fixing meshes or NB2C glues ahead of suture fixation. However, these products have been shown to be at least substantially equivalent, and moderate-quality RCTs have suggested that both fibrin sealant and NB2C glues may have a beneficial effect on reducing immediate post-operative pain and chronic pain in at-risk populations, such as younger active patients. It will ultimately be up to surgeons and health-care policy makers to decide whether based on the limited evidence these products represent a worthwhile cost for their patients.
Collapse
Affiliation(s)
- D L Sanders
- Department of Upper GI Surgery, Royal Cornwall Hospital, Treliske, Truro, TR1 3LJ, UK,
| | | |
Collapse
|
17
|
Bracale U, Rovani M, Picardo A, Merola G, Pignata G, Sodo M, Di Salvo E, Ratto EL, Noceti A, Melillo P, Pecchia L. Beneficial effects of fibrin glue (Quixil) versus Lichtenstein conventional technique in inguinal hernia repair: a randomized clinical trial. Hernia 2012. [PMID: 23180147 DOI: 10.1007/s10029-012-1020-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
INTRODUCTION In inguinal hernia repair, many complications are due to mesh fixation technique. Therefore, new types of atraumatic methods of fixation have been proposed. In this article, we present the results of a prospective multicentric parallel randomized controlled trial aiming to compare two mesh fixation techniques: fibrin sealant (QUIXIL(®), Omrix Biopharmaceuticals S.A., Belgium) and Lichtenstein technique. METHOD Adult patients with primary uncomplicated inguinal hernia were randomized in two groups: fibrin sealant group (FSG) and Lichtenstein group (LTG). The two groups underwent a follow-up of 15 months. Operative time is the primary outcome. Intraoperative and postoperative outcomes were analyzed. Moreover, a differential cost analysis was performed. Patients and evaluators (with exception of the surgeon who treated the patient) were blinded. RESULTS A total of 102 patients, 50 in FSG and 52 in LTG, were enrolled from January 2009 to June 2010, and two patients were lost to follow-up at the twelfth month. No significant differences in baseline and clinical characteristics were observed in the two groups. Operative time was longer in LTG (median/ interquartile range: 35 min/30-42.5 min vs. 31 min/28-35 min; effect size: 0.65/95% CI 0.50-0.91; p < 0.05). No differences in intraoperative complications were observed. No significant differences were observed in early complication rate (RR = 0.62; p > 0.05). Numbness rate was lower in the FSG at 1 week (RR = 0.43; p < 0.01) and at 1 month (RR = 0.17; p < 0.05). No significant differences were observed after 6 months. Postoperative pain was lower in the FSG at 1 week (0/0-1 vs. 1/0-2; p < 0.05) and at 1 month (0/0-0 vs. 0/0-1; p < 0.05). Pain disappeared in all patients after 6 months. Analgesic assumption rate was lower in the FSG (RR = 0.42; p < 0.05). Twenty per cent of FSG and 9.62% of LTG patients were discharged within 12 h; 78% of FSG and 90.38% of LTG patients were discharged within 24 h. The only one recurrence we observed was in FSG group. About costs, although fibrin sealant needed for one mesh fixation is about 10 times more costly than the needed sutures, the total costs of the two procedures did not change significantly. This was mainly due to reduction in operative time. CONCLUSIONS The use of fibrin sealant determined a significant reduction in short-term numbness rate and postoperative pain. There was no relevant difference in total costs per patient between the two procedures.
Collapse
Affiliation(s)
- U Bracale
- Department of General, Vascular and Thoracic Surgery, University of Naples "Federico II", Via Pansini n°5, Naples, Italy,
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Abstract
OBJECTIVE The objective of this review is to evaluate the results of laparoscopic treatment of ventral hernias using intra-peritoneal prosthetic mesh through a review of published surgical series. METHODS All large series of patients treated for an incisional hernia by laparoscopy and published between 2002 and 2011 were identified. The results of controlled randomized series comparing this technique with open surgical repair were analyzed. RESULTS Twenty-two series with a total of 7057 patients were analyzed (range 51-1242); the mean Body Mass Index (BMI) was 32 (range: 28.5-46), and the mean size of the hernia defect was 10.6 cm (range: 6-14.9 cm). The mean rate of conversion to open surgical repair was 2.7%. Mean operative duration was 90 ± 33 minutes. Mortality was 0.8%, usually due to an unrecognized intestinal injury (1.6%), which occurred more frequently with second or iterative hernia repairs. Hospital stay averaged 2.5 days. The infection rate was 0.3% and the rate of hernia recurrence was 4.6% (with a mean follow-up of 36 months). No statistically significant differences were found in terms of post-operative complications or hernia recurrence in the randomized studies comparing laparoscopic to open anterior abdominal surgical repair. However, duration of hospital stay was shorter after laparoscopy in some studies. CONCLUSION Laparoscopic repair of ventral incisional hernia is technically feasible and reliable for large hernia defects, even in obese patients. This approach should be reserved for patients with no history of previous hernia repair in order to avoid the risk of intestinal injury. It appears to allow for a shortened duration of hospitalization.
Collapse
|