• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4600964)   Today's Articles (388)   Subscriber (49365)
For: Lee H, Tatsumi E, Homma A, Tsukiya T, Taenaka Y. Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart. J Artif Organs 2006;9:154-60. [PMID: 16998700 DOI: 10.1007/s10047-006-0332-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2005] [Accepted: 02/27/2006] [Indexed: 11/27/2022]
Number Cited by Other Article(s)
1
Larti F, Geraiely B, Asli SH, Moghadam AS. Revisiting echocardiographic features of prosthetic heart valves: the necessity of correct differentiation of mono-leaflet vs. bileaflet mechanical heart valves in a case report. J Cardiothorac Surg 2024;19:176. [PMID: 38576022 PMCID: PMC10996195 DOI: 10.1186/s13019-024-02633-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 03/11/2024] [Indexed: 04/06/2024]  Open
2
Lee H, Taenaka Y. Characteristics of Mechanical Heart Valve Cavitation in a Pneumatic Ventricular Assist Device. Artif Organs 2008;32:453-60. [DOI: 10.1111/j.1525-1594.2008.00564.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
3
Journal of Artificial Organs 2007: the year in review. J Artif Organs 2008;11:4-11. [PMID: 18414986 DOI: 10.1007/s10047-008-0404-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2008] [Indexed: 10/22/2022]
4
Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve. ASAIO J 2008;54:25-30. [PMID: 18204312 DOI: 10.1097/mat.0b013e318161d71c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
5
Lee H, Homma A, Taenaka Y. Hydrodynamic Characteristics of Bileaflet Mechanical Heart Valves in an Artificial Heart: Cavitation and Closing Velocity. Artif Organs 2007;31:532-7. [PMID: 17584477 DOI: 10.1111/j.1525-1594.2007.00419.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
6
Sawa Y, Horiuchi T, Kishida A, Masuzawa T, Nishimura M, Tatsumi E, Tomizawa Y, Watanabe H. Journal of Artificial Organs 2006: the year in review. J Artif Organs 2007;10:53-9. [PMID: 17574506 DOI: 10.1007/s10047-007-0386-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2007] [Indexed: 10/23/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA