1
|
Shao Z, Tao T, Xu H, Chen C, Lee I, Chung S, Dong Z, Li W, Ma L, Bai H, Chen Q. Recent progress in biomaterials for heart valve replacement: Structure, function, and biomimetic design. VIEW 2021. [DOI: 10.1002/viw.20200142] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Affiliation(s)
- Ziyu Shao
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine & Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University Hangzhou 310006 China
- State Key Laboratory of Chemical Engineering College of Chemical and Biological Engineering Zhejiang University Hangzhou China
| | - Tingting Tao
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Hongfei Xu
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Cen Chen
- College of Life Sciences and Medicine Zhejiang Sci‐Tech University Hangzhou China
| | - In‐Seop Lee
- College of Life Sciences and Medicine Zhejiang Sci‐Tech University Hangzhou China
- Institute of Natural Sciences Yonsei University Seoul Republic of Korea
| | - Sungmin Chung
- Biomaterials R&D Center GENOSS Co., Ltd. Suwon‐si Republic of Korea
| | - Zhihui Dong
- State Key Laboratory of Chemical Engineering College of Chemical and Biological Engineering Zhejiang University Hangzhou China
| | - Weidong Li
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Liang Ma
- Department of Cardiovascular Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China
| | - Hao Bai
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine & Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University Hangzhou 310006 China
- State Key Laboratory of Chemical Engineering College of Chemical and Biological Engineering Zhejiang University Hangzhou China
| | - Qianming Chen
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine & Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University Hangzhou 310006 China
| |
Collapse
|
2
|
Jung SY, Lee SJ, Kim HY, Park HS, Wang Z, Kim HJ, Yoo JJ, Chung SM, Kim HS. 3D printed polyurethane prosthesis for partial tracheal reconstruction: a pilot animal study. Biofabrication 2016; 8:045015. [PMID: 27788126 DOI: 10.1088/1758-5090/8/4/045015] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A ready-made, acellular patch-type prosthesis is desirable in repairing partial tracheal defects in the clinical setting. However, many of these prostheses may not show proper biological integration and biomechanical function when they are transplanted. In this study, we developed a novel 3D printed polyurethane (PU) tracheal scaffold with micro-scale architecture to allow host tissue infiltration and adequate biomechanical properties to withstand physiological tracheal condition. A half-pipe shaped PU scaffold (1.8 cm of height, 0.18 cm thickness, and 2 cm of diameter) was fabricated by 3D printing of PU 200 μm PU beam. The 3D printed tracheal scaffolds consisted of a porous inner microstructure with 200 × 200 × 200 μm3 sized pores and a non-porous outer layer. The mechanical properties of the scaffolds were 3.21 ± 1.02 MPa of ultimate tensile strength, 2.81 ± 0.58 MPa of Young's modulus, and 725% ± 41% of elongation at break. To examine the function of the 3D printed tracheal scaffolds in vivo, the scaffolds were implanted into 1.0 × 0.7 cm2 sized anterior tracheal defect of rabbits. After implantation, bronchoscopic examinations revealed that the implanted tracheal scaffolds were patent for a 16 week-period. Histologic findings showed that re-epithelialization after 4 weeks of implantation and ciliated respiratory epithelium with ciliary beating after 8 weeks of implantation were observed at the lumen of the implanted tracheal scaffolds. The ingrowth of the connective tissue into the scaffolds was observed at 4 weeks after implantation. The biomechanical properties of the implanted tracheal scaffolds were continually maintained for 16 week-period. The results demonstrated that 3D printed tracheal scaffold could provide an alternative solution as a therapeutic treatment for partial tracheal defects.
Collapse
Affiliation(s)
- Soo Yeon Jung
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Ewha Womans University, Seoul 07985, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Sumikura H, Nakayama Y, Ohnuma K, Kishimoto S, Takewa Y, Tatsumi E. In vitro hydrodynamic evaluation of a biovalve with stent (tubular leaflet type) for transcatheter pulmonary valve implantation. J Artif Organs 2015; 18:307-14. [PMID: 26141924 DOI: 10.1007/s10047-015-0851-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Accepted: 06/21/2015] [Indexed: 10/23/2022]
Abstract
We have been developing an autologous heart valve-shaped tissue with a stent (stent-biovalve) for transcatheter pulmonary valve implantation (TPVI) using "in-body tissue architecture" technology. In this study, the hydrodynamic performance of a stent-biovalve with tubular leaflets was evaluated by changing its leaflet height in an in vitro test in order to determine the appropriate stent-biovalve form for the pulmonary valve. A specially designed, self-expandable, stent-mounted, cylindrical acrylic mold was placed in a dorsal subcutaneous pouch of goat, and the implant was extracted 2 months later. Only the cylindrical acrylic mold was removed from the implant, and a tubular hollow structure of membranous connective tissue impregnated with the stent strut was obtained. Half of tubular tissue was completely folded in half inwards, and 3 commissure parts were connected to form 3 leaflets, resulting in the preparation of a stent-biovalve with tubular leaflets (25-mm ID). The stent-biovalve with adjusting leaflet height (13, 14, 15, 17, 20, and 25 mm) was fixed to a specially designed pulsatile mock circulation circuit under pulmonary valve conditions using 37 °C saline. The mean pressure difference and effective orifice area were better than those of the biological valve. The lowest and highest leaflet heights had a high regurgitation rate due to lack of coaptation or prevention of leaflet movement, respectively. The lowest regurgitation (ca. 11%) was observed at a height of 15 mm. The leaflet height was found to significantly affect the hydrodynamics of stent-biovalves, and the existence of an appropriate leaflet height became clear.
Collapse
Affiliation(s)
- Hirohito Sumikura
- Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan.
| | - Yasuhide Nakayama
- Division of Medical Engineering and Materials, National Cerebral and Cardiovascular Center Research Institute, Osaka, Japan
| | - Kentaro Ohnuma
- Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Satoru Kishimoto
- Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Yoshiaki Takewa
- Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Eisuke Tatsumi
- Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| |
Collapse
|
4
|
ANDO T. Star Polymers for Biomedical Applications. KOBUNSHI RONBUNSHU 2015. [DOI: 10.1295/koron.2015-0009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Tsuyoshi ANDO
- Graduate School of Materials Science, Nara Institute of Science and Technology
| |
Collapse
|
5
|
Totani M, Ando T, Terada K, Terashima T, Kim IY, Ohtsuki C, Xi C, Kuroda K, Tanihara M. Utilization of star-shaped polymer architecture in the creation of high-density polymer brush coatings for the prevention of platelet and bacteria adhesion. Biomater Sci 2014; 2:1172-1185. [PMID: 25485105 PMCID: PMC4251873 DOI: 10.1039/c4bm00034j] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We demonstrate utilization of star-shaped polymers as high-density polymer brush coatings and their effectiveness to inhibit the adhesion of platelets and bacteria. Star polymers consisting of poly(2-hydroxyethyl methacrylate) (PHEMA) and/or poly(methyl methacrylate) (PMMA), were synthesized using living radical polymerization with a ruthenium catalyst. The polymer coatings were prepared by simple drop casting of the polymer solution onto poly(ethylene terephthalate) (PET) surfaces and then dried. Among the star polymers prepared in this study, the PHEMA star polymer (star-PHEMA) and the PHEMA/PMMA (mol. ratio of 71/29) heteroarm star polymer (star-H71M29) coatings showed the highest percentage of inhibition against platelet adhesion (78-88% relative to noncoated PET surface) and Escherichia coli (94-97%). These coatings also showed anti-adhesion activity against platelets after incubation in Dulbecco's phosphate buffered saline or surfactant solution for 7 days. In addition, the PMMA component of the star polymers increased the scratch resistance of the coating. These results indicate that the star-polymer architecture provides high polymer chain density on PET surfaces to prevent adhesion of platelets and bacteria, as well as coating stability and physical durability to prevent exposure of bare PET surfaces. The star polymers provide a simple and effective approach to preparing anti-adhesion polymer coatings on biomedical materials against the adhesion of platelets and bacteria.
Collapse
Affiliation(s)
- Masayasu Totani
- Graduate School of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan
| | - Tsuyoshi Ando
- Graduate School of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan
| | - Kayo Terada
- Graduate School of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan
| | - Takaya Terashima
- Department of Polymer Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan
| | - Ill Yong Kim
- Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Naogya 464-8603, Japan
| | - Chikara Ohtsuki
- Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Naogya 464-8603, Japan
| | - Chuanwu Xi
- Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Kenichi Kuroda
- Department of Biologic and Materials Sciences, School of Dentistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Masao Tanihara
- Graduate School of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan
| |
Collapse
|
6
|
Sumikura H, Nakayama Y, Ohnuma K, Takewa Y, Tatsumi E. In Vitro Evaluation of a Novel Autologous Aortic Valve (Biovalve) With a Pulsatile Circulation Circuit. Artif Organs 2013; 38:282-9. [DOI: 10.1111/aor.12173] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Hirohito Sumikura
- Department of Artificial Organs; National Cerebral and Cardiovascular Center Research Institute; Suita Osaka Japan
| | - Yasuhide Nakayama
- Department of Biomedical Engineering; National Cerebral and Cardiovascular Center Research Institute; Suita Osaka Japan
| | - Kentaro Ohnuma
- Department of Artificial Organs; National Cerebral and Cardiovascular Center Research Institute; Suita Osaka Japan
| | - Yoshiaki Takewa
- Department of Artificial Organs; National Cerebral and Cardiovascular Center Research Institute; Suita Osaka Japan
| | - Eisuke Tatsumi
- Department of Artificial Organs; National Cerebral and Cardiovascular Center Research Institute; Suita Osaka Japan
| |
Collapse
|
7
|
|