Zhao X, Zeng Y, Yan B, Liu Y, Qian Y, Zhu A, Zhao Y, Zhang X, Zhang C, Wan Z. A novel extraction-free dual HiFi-LAMP assay for detection of methicillin-sensitive and methicillin-resistant Staphylococcus aureus. Microbiol Spectr 2024; 12:e0413323. [PMID: 38376361 PMCID: PMC10986577 DOI: 10.1128/spectrum.04133-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 01/26/2024] [Indexed: 02/21/2024] Open
Abstract
Staphylococcus aureus (S. aureus) is a leading cause of bacteremia and blood stream infections. Methicillin-resistant S. aureus (MRSA) that first appeared in 1961 often caused hospital-acquired infections (HAIs) and community-acquired infections (CAIs) and was associated with high mortality rate. Accurate and rapid point-of-care testing (POCT) of MRSA is crucial for clinical management and treatment of MRSA infections, as well as the prevention and control of HAIs and CAIs. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of methicillin-susceptible S. aureus and MRSA. The dual HiFi-LAMP assay can detect 30 copies/reaction of nuc and mecA genes with detection limits of 147 and 158 copies per 25 µL reaction, respectively. A retrospective clinical evaluation with 107 clinical S. aureus isolates showed both sensitivity and specificity of 100%. A prospective clinical evaluation with 35 clinical samples revealed a specificity of 100% and a sensitivity of 92.3%. The dual HiFi-LAMP assay can detect almost all S. aureus samples (141/142; 99.3%) within 20 min, implying that the entire HiFi-LAMP assay (including sample process) can be completed within 40 min, extremely significantly shorter than 3-5 days by the traditional clinical microbial culture and antibiotic susceptibility testing. The novel extraction-free dual HiFi-LAMP assay can be used as a robust POCT tool to promote precise diagnosis and treatment of MRSA infections in hospitals and to facilitate surveillance of MRSA at hospital and community settings.IMPORTANCEMethicillin-resistant Staphylococcus aureus (MRSA) was associated with high mortality rate and listed as a "priority pathogen" by the World Health Organization. Accurate and rapid point-of-care testing (POCT) of MRSA is critically required for clinical management and treatment of MRSA infections. Some previous LAMP-based POCT assays for MRSA might be questionable due to their low specificity and the lack of appropriate evaluation directly using clinical samples. Furthermore, they are relatively tedious and time-consuming because they require DNA extraction and lack multiplex detection capacity. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of MRSA and methicillin-susceptible S. aureus. The assay has high specificity and sensitivity and can be completed within 40 min. Clinical evaluation with real clinical samples and clinical isolates showed excellent performance with 100% specificity and 92.3%-100% sensitivity. The novel extraction-free assay may be a robust POCT tool to promote precise diagnosis of MRSA infections and facilitate surveillance of MRSA at hospital and community settings.
Collapse
Affiliation(s)
- Xiuli Zhao
- Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
| | - Yi Zeng
- Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Beibei Yan
- Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
| | - Yanping Liu
- Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
| | - Yueqin Qian
- Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
| | - Aiping Zhu
- Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
| | - Yongjuan Zhao
- Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Xiaoling Zhang
- Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Chiyu Zhang
- Shanghai Public Health Clinical Center, Fudan University, Shanghai, China
| | - Zhenzhou Wan
- Medical Laboratory of Taizhou Fourth People’s Hospital, Taizhou, China
| |
Collapse
|
2
|
Heuser E, Becker K, Idelevich EA. Bactericidal Activity of Sodium Bituminosulfonate against Staphylococcus aureus. Antibiotics (Basel) 2022; 11:antibiotics11070896. [PMID: 35884150 PMCID: PMC9311858 DOI: 10.3390/antibiotics11070896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 12/10/2022] Open
Abstract
Antibiotic resistance is increasing worldwide making it necessary to search for alternative antimicrobials. Sodium bituminosulfonate is a long-known substance, whose antimicrobial inhibitory activity has recently been re-evaluated. However, to the best of our knowledge, the bactericidal mode of action of this substance has not been systematically characterized. The aim of this study was to investigate the in vitro bactericidal activity of sodium bituminosulfonate by determining the minimal bactericidal concentrations (MBC), as well as the rapidity of bactericidal effect by time-kill curves. Clinical isolates of methicillin-susceptible (MSSA, n = 20) and methicillin-resistant (mecA/mecC-MRSA, n = 20) Staphylococcus aureus were used to determine MBC by a broth microdilution method. Sodium bituminosulfonate (Ichthyol® light) was tested in double-dilution concentration steps ranging from 0.03 g/L to 256 g/L. For time-kill analysis, two reference and two clinical S. aureus strains were tested with different concentrations of sodium bituminosulfonate (1× minimal inhibitory concentration (MIC), 2× MIC, 4× MIC, 16× MIC and 256× MIC). For MSSA isolates, MBC50, MBC90 and the MBC range were 0.5 g/L, 1.0 g/L and 0.125–1.0 g/L; (MBC/MIC ratio)50, (MBC/MIC ratio)90 and the range of the MBC/MIC ratio were 4, 4 and 1–8, respectively. Among MRSA isolates, MBC50, MBC90 and the MBC range amounted to 0.5 g/L, 1.0 g/L and 0.06–1.0 g/L; (MBC/MIC ratio)50, (MBC/MIC ratio)90 and the range of the MBC/MIC ratio were 2, 4 and 1–8, respectively. Time-kill kinetics revealed a bactericidal effect after 30 min for sodium bituminosulfonate concentrations of 16× MIC and 256× MIC. The bactericidal activity against MSSA and MRSA was demonstrated for sodium bituminosulfonate. The killing was very rapid with the initial population reduced by 99.9% after only short incubation with concentrations of 16× MIC and higher.
Collapse
Affiliation(s)
- Elisa Heuser
- Friedrich Loeffler-Institute of Medical Microbiology, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße 1, 17489 Greifswald, Germany; (E.H.); (K.B.)
| | - Karsten Becker
- Friedrich Loeffler-Institute of Medical Microbiology, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße 1, 17489 Greifswald, Germany; (E.H.); (K.B.)
| | - Evgeny A. Idelevich
- Friedrich Loeffler-Institute of Medical Microbiology, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße 1, 17489 Greifswald, Germany; (E.H.); (K.B.)
- Institute of Medical Microbiology, University Hospital Münster, Domagkstraße 10, 48149 Münster, Germany
- Correspondence: ; Tel.: +49-3834-86-5563; Fax: +49-3834-86-5561
| |
Collapse
|
3
|
Long LJ, Lin M, Chen YR, Meng X, Cui TT, Li YP, Guo XG. Evaluation of the loop-mediated isothermal amplification assay for Staphylococcus aureus detection: a systematic review and meta-analysis. Ann Clin Microbiol Antimicrob 2022; 21:27. [PMID: 35751121 PMCID: PMC9233341 DOI: 10.1186/s12941-022-00522-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Accepted: 06/06/2022] [Indexed: 12/14/2022] Open
Abstract
Background Staphylococcus aureus can cause many diseases and even death. It’s important to detect Staphylococcus aureus rapidly and reliably. The accuracy of a novel test named LAMP in detecting Staphylococcus aureus is unclear. Therefore, a systematic review and meta-analysis were conducted to evaluate the accuracy of the LAMP assay for Staphylococcus aureus detection. Methods Four databases were searched for relevant studies. Meta-DiSc 1.4.0 and Stata 12.0 were used for statistical analysis. At the same time, we used QUADAS-2 to assess the studies we included. Two groups of subgroup analysis were done to differentiate the diagnostic effects of various LAMP tests and in cases of different gold standards. Results 11 studies were identified and 19 2 × 2 contingency tables were extracted in our study. The results showed that both pooled sensitivity and specificity of the LAMP assay were 99% (95% CI 99–100). Conclusion The LAMP assay demonstrated high sensitivity and specificity in diagnosing Staphylococcus aureus. Supplementary Information The online version contains supplementary material available at 10.1186/s12941-022-00522-6.
Collapse
Affiliation(s)
- Li-Jun Long
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China.,Department of Medical Laboratory Technology, The King Med School of Laboratory Medicine, Guangzhou Medical University, Guangzhou, 511436, China
| | - Min Lin
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China.,Department of Traditional Chinese and Western Medicine in Clinical Medicine, The Clinical School of Traditional Chinese and Western Medicine of Guangzhou Medical University, Guangzhou, 511436, China
| | - Yu-Ran Chen
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China.,Department of Medical Laboratory Technology, The King Med School of Laboratory Medicine, Guangzhou Medical University, Guangzhou, 511436, China
| | - Xin Meng
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China.,Department of Medical Imageology, The Third Clinical School of Guangzhou Medical University, Guangzhou, 511436, China
| | - Ting-Ting Cui
- Department of Pediatrics, Pediatrics School, Guangzhou Medical University, Guangzhou, 511436, China
| | - Ya-Ping Li
- Department of Clinical Medicine, The Second Clinical School of Guangzhou Medical University, Guangzhou, 511436, China
| | - Xu-Guang Guo
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China. .,Department of Medical Imageology, The Third Clinical School of Guangzhou Medical University, Guangzhou, 511436, China. .,Key Laboratory for Major Obstetric Diseases of Guangdong Province, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China. .,Key Laboratory of Reproduction and Genetics of Guangdong Higher Education Institutes, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China.
| |
Collapse
|
4
|
Recent Developments in Phenotypic and Molecular Diagnostic Methods for Antimicrobial Resistance Detection in Staphylococcus aureus: A Narrative Review. Diagnostics (Basel) 2022; 12:diagnostics12010208. [PMID: 35054375 PMCID: PMC8774325 DOI: 10.3390/diagnostics12010208] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/12/2022] [Accepted: 01/13/2022] [Indexed: 11/17/2022] Open
Abstract
Staphylococcus aureus is an opportunistic pathogen responsible for a wide range of infections in humans, such as skin and soft tissue infections, pneumonia, food poisoning or sepsis. Historically, S. aureus was able to rapidly adapt to anti-staphylococcal antibiotics and become resistant to several classes of antibiotics. Today, methicillin-resistant S. aureus (MRSA) is a multidrug-resistant pathogen and is one of the most common bacteria responsible for hospital-acquired infections and outbreaks, in community settings as well. The rapid and accurate diagnosis of antimicrobial resistance in S. aureus is crucial to the early initiation of directed antibiotic therapy and to improve clinical outcomes for patients. In this narrative review, I provide an overview of recent phenotypic and molecular diagnostic methods for antimicrobial resistance detection in S. aureus, with a particular focus on MRSA detection. I consider methods for resistance detection in both clinical samples and isolated S. aureus cultures, along with a brief discussion of the advantages and the challenges of implementing such methods in routine diagnostics.
Collapse
|
5
|
Bach K, Edel B, Höring S, Bartoničkova L, Glöckner S, Löffler B, Bahrs C, Rödel J. Performance of the eazyplex® BloodScreen GN as a simple and rapid molecular test for identification of Gram-negative bacteria from positive blood cultures. Eur J Clin Microbiol Infect Dis 2021; 41:489-494. [PMID: 34807364 PMCID: PMC8831353 DOI: 10.1007/s10096-021-04383-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 11/16/2021] [Indexed: 12/18/2022]
Abstract
The LAMP-based eazyplex® BloodScreen GN was evaluated for the detection of frequent Gram-negatives directly from positive blood culture (BC) bottles. A total of 449 BCs were analyzed. Sensitivities and specificities were 100% and 100% for Escherichia coli, 95.7% and 100% for Klebsiella pneumoniae, 100% and 100% for blaCTX-M, 100% and 100% for Klebsiella oxytoca, 100% and 99% for Proteus mirabilis, and 100% and 99.8% for Pseudomonas aeruginosa, respectively. The time to result ranged from 8 to 16 min, plus about 6 min for sample preparation. The eazyplex® BloodScreen GN is a reliable molecular assay for rapid BC testing.
Collapse
Affiliation(s)
- Katharina Bach
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany
| | - Birgit Edel
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany
| | - Steffen Höring
- Division of Infection Control and Infectious Diseases, RWTH Aachen University Hospital, Aachen, Germany
| | - Lucie Bartoničkova
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany
| | - Stefan Glöckner
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany
| | - Bettina Löffler
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany
| | - Christina Bahrs
- Institute for Infectious Diseases and Infection Control, Jena University Hospital, Friedrich Schiller University, Jena, Germany
- Division of Infectious Diseases and Tropical Medicine, Department of Medicine I, Medical University of Vienna, Vienna, Austria
| | - Jürgen Rödel
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany.
| |
Collapse
|