1
|
Göstemeyer G, Preus M, Elhennawy K, Schwendicke F, Paris S, Askar H. Accuracy of different approaches for detecting proximal root caries lesions in vitro. Clin Oral Investig 2023; 27:1143-1151. [PMID: 36112228 PMCID: PMC9985551 DOI: 10.1007/s00784-022-04709-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 09/05/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The objective was to evaluate the diagnostic accuracy of radiographic evaluation (XR), visual-tactile assessment (VT), laser-fluorescence (LF) (DIAGNOdent Pen/KaVo), and near-infrared-light transillumination (NILT) (DIAGNOcam/KaVo) on proximal root caries lesions in vitro. METHODS Two-hundred extracted permanent premolars and molars with and without proximal root caries lesions were allocated to 50 diagnostic models simulating the proximal contacts between teeth and mounted in a phantom dummy head. Two independent examiners used the diagnostic approaches to detect any or advanced root caries lesions, with histologic evaluation of the lesions serving as reference. Receiver operating characteristic (ROC) curves were employed, and sensitivity, specificity, and the area under the ROC curve (AUC) are calculated. Significant differences in mean AUCs between approaches were assumed if p < 0.05 (two-sample t-test). RESULTS NILT was not applicable for proximal root caries detection. The sensitivity/specificity to detect any lesions was 0.81/0.63 for XR, 0.76/0.88 for VT and 0.81/0.95 for LF, and the sensitivity/specificity to detect advanced lesions was 0.43/0.94 for XR, 0.66/0.99 for VT, and 0.83/0.78 for LF, respectively. For both, any and advanced root caries lesions, mean AUCs for LF and VT were significantly higher compared to XR (p < 0.05). For any root caries lesions, LF was significantly more accurate than VT (p = 0.01), but not for advanced root caries lesions (p = 0.59). CONCLUSIONS Under the in vitro conditions chosen, LF and VT were more accurate than XR to detect proximal root caries lesions, with LF being particularly useful for initial lesion stages. CLINICAL RELEVANCE LF might be a useful diagnostic aid for proximal root caries diagnosis. Clinical studies are necessary to corroborate the findings.
Collapse
Affiliation(s)
- Gerd Göstemeyer
- Department of Operative, Preventive and Pediatric Dentistry, Charité - Universitätsmedizin Berlin, Assmannshauser Straße 4-6, 14197, Berlin, Germany.
| | - Mareike Preus
- Department of Operative, Preventive and Pediatric Dentistry, Charité - Universitätsmedizin Berlin, Assmannshauser Straße 4-6, 14197, Berlin, Germany
| | - Karim Elhennawy
- Department of Orthodontics, Dentofacial Orthopedics and Pedodontics, Charité - Universitätsmedizin Berlin, Assmannshauser Straße 4-6, 14197, Berlin, Germany
| | - Falk Schwendicke
- Department of Oral Diagnostics, Digital Health and Health Services Research, Charité - Universitätsmedizin Berlin, Assmannshauser Straße 4-6, 14197, Berlin, Germany
| | - Sebastian Paris
- Department of Operative, Preventive and Pediatric Dentistry, Charité - Universitätsmedizin Berlin, Assmannshauser Straße 4-6, 14197, Berlin, Germany
| | - Haitham Askar
- Department of Operative, Preventive and Pediatric Dentistry, Charité - Universitätsmedizin Berlin, Assmannshauser Straße 4-6, 14197, Berlin, Germany
| |
Collapse
|
2
|
Emerging Technologies for Dentin Caries Detection-A Systematic Review and Meta-Analysis. J Clin Med 2022; 11:jcm11030674. [PMID: 35160127 PMCID: PMC8837049 DOI: 10.3390/jcm11030674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 01/19/2022] [Accepted: 01/26/2022] [Indexed: 11/20/2022] Open
Abstract
This systematic review and meta-analysis aimed at assessing the diagnostic accuracy of emerging technologies, such as laser fluorescence (LF), transillumination, light-emitting diode devices, optical coherence tomography (OCT), alternating current impedance spectroscopy, fluorescence cameras (FC), photo-thermal radiometry, and modulated luminescence technology. In vivo and in vitro results of such non-ionizing, non-invasive, and non-destructive methods’ effectiveness in non-cavitated dentin caries detection are sometimes ambiguous. Following the PRISMA guidelines, 34 relevant research articles published between 2011–2021 were selected. The risk of bias was assessed with a tool tailored for caries diagnostic studies, and subsequent quantitative uni- and bi-variate meta-analysis was carried out in separate sub-groups according to the investigated surface (occlusal/proximal) and study setting (in vivo/in vitro). In spite of the high heterogeneity across the review groups, in vitro studies on LF and FC proved a good diagnostic ability for the occlusal surface, with area under the curve (AUC) of 0.803 (11 studies) and 0.845 (five studies), respectively. OCT studies reported an outstanding performance with an overall AUC = 0.945 (four studies). Promising technologies, such as OCT or FC VistaProof, still need well-designed and well-powered studies to accrue experimental and clinical data for conclusive medical evidence, especially for the proximal surface. Registration: INPLASY202210097.
Collapse
|
3
|
Kapor S, Rankovic MJ, Khazaei Y, Crispin A, Schüler I, Krause F, Lussi A, Neuhaus K, Eggmann F, Michou S, Ekstrand K, Huysmans MC, Kühnisch J. Systematic review and meta-analysis of diagnostic methods for occlusal surface caries. Clin Oral Investig 2021; 25:4801-4815. [PMID: 34128130 PMCID: PMC8342337 DOI: 10.1007/s00784-021-04024-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 06/01/2021] [Indexed: 02/01/2023]
Abstract
AIM This systematic review and meta-analysis aimed to assess the diagnostic performance of commonly used methods for occlusal caries diagnostics, such as visual examination (VE), bitewing radiography (BW) and laser fluorescence (LF), in relation to their ability to detect (dentin) caries under clinical and laboratory conditions. MATERIALS AND METHODS A systematic search of the literature was performed to identify studies meeting the inclusion criteria using the PIRDS concept (N = 1090). A risk of bias (RoB) assessment tool was used for quality evaluation. Reports with low/moderate RoB, well-matching thresholds for index and reference tests and appropriate reporting were included in the meta-analysis (N = 37; 29 in vivo/8 in vitro). The pooled sensitivity (SE), specificity (SP), diagnostic odds ratio (DOR) and areas under ROC curves (AUCs) were computed. RESULTS SP ranged from 0.50 (fibre-optic transillumination/caries detection level) to 0.97 (conventional BW/dentine detection level) in vitro. AUCs were typically higher for BW or LF than for VE. The highest AUC of 0.89 was observed for VE at the 1/3 dentin caries detection level; SE (0.70) was registered to be higher than SP (0.47) for VE at the caries detection level in vivo. CONCLUSION The number of included studies was found to be low. This underlines the need for high-quality caries diagnostic studies that further provide data in relation to multiple caries thresholds. CLINICAL RELEVANCE VE, BW and LF provide acceptable measures for their diagnostic performance on occlusal surfaces, but the results should be interpreted with caution due to the limited data in many categories.
Collapse
Affiliation(s)
- Svetlana Kapor
- Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilian University, Munich, Germany
| | - Mila Janjic Rankovic
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital, Ludwig-Maximilian Universität München, Munich, Germany
| | - Yegane Khazaei
- Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilian University, Munich, Germany
- Institute of Medical Biometry and Epidemiology, Ludwig-Maximilian University of Munich, Munich, Germany
| | - Alexander Crispin
- Institute of Medical Biometry and Epidemiology, Ludwig-Maximilian University of Munich, Munich, Germany
| | - Ina Schüler
- Department of Orthodontics, Section of Preventive and Paediatric Dentistry, University Hospital, Jena, Germany
| | - Felix Krause
- Clinic for Operative Dentistry, Periodontology and Preventive Dentistry, University Hospital RWTH Aachen, Aachen, Germany
| | - Adrian Lussi
- Department of Operative Dentistry and Periodontology, Faculty of Dentistry, University Medical Centre, Freiburg, Germany
- School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Klaus Neuhaus
- Clinic of Periodontology, Endodontology and Cariology, University Centre for Dental Medicine Basel, University of Basel, Basel, Switzerland
- Department of Dermatology, Inselspital-Bern University Hospital, Bern, Switzerland
| | - Florin Eggmann
- Clinic of Periodontology, Endodontology and Cariology, University Centre for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Stavroula Michou
- Department of Odontology, University Copenhagen, Copenhagen, Denmark
| | - Kim Ekstrand
- Department of Odontology, University Copenhagen, Copenhagen, Denmark
| | | | - Jan Kühnisch
- Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilian University, Munich, Germany.
- Poliklinik Für Zahnerhaltung Und Parodontologie, Klinikum Der Universität München, LMU München, Goethestraße 70, 80336, München, Germany.
| |
Collapse
|
4
|
Macey R, Walsh T, Riley P, Glenny AM, Worthington HV, O'Malley L, Clarkson JE, Ricketts D. Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries. Cochrane Database Syst Rev 2021; 6:CD014546. [PMID: 34124773 PMCID: PMC8428329 DOI: 10.1002/14651858.cd014546] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The detection and diagnosis of caries at the initial (non-cavitated) and moderate (enamel) levels of severity is fundamental to achieving and maintaining good oral health and prevention of oral diseases. An increasing array of methods of early caries detection have been proposed that could potentially support traditional methods of detection and diagnosis. Earlier identification of disease could afford patients the opportunity of less invasive treatment with less destruction of tooth tissue, reduce the need for treatment with aerosol-generating procedures, and potentially result in a reduced cost of care to the patient and to healthcare services. OBJECTIVES To determine the diagnostic accuracy of different visual classification systems for the detection and diagnosis of non-cavitated coronal dental caries for different purposes (detection and diagnosis) and in different populations (children or adults). SEARCH METHODS Cochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 30 April 2020); Embase Ovid (1980 to 30 April 2020); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 30 April 2020); and the World Health Organization International Clinical Trials Registry Platform (to 30 April 2020). We studied reference lists as well as published systematic review articles. SELECTION CRITERIA We included diagnostic accuracy study designs that compared a visual classification system (index test) with a reference standard (histology, excavation, radiographs). This included cross-sectional studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. Studies reporting at both the patient or tooth surface level were included. In vitro and in vivo studies were considered. Studies that explicitly recruited participants with caries into dentine or frank cavitation were excluded. We also excluded studies that artificially created carious lesions and those that used an index test during the excavation of dental caries to ascertain the optimum depth of excavation. DATA COLLECTION AND ANALYSIS We extracted data independently and in duplicate using a standardised data extraction and quality assessment form based on QUADAS-2 specific to the review context. Estimates of diagnostic accuracy were determined using the bivariate hierarchical method to produce summary points of sensitivity and specificity with 95% confidence intervals (CIs) and regions, and 95% prediction regions. The comparative accuracy of different classification systems was conducted based on indirect comparisons. Potential sources of heterogeneity were pre-specified and explored visually and more formally through meta-regression. MAIN RESULTS We included 71 datasets from 67 studies (48 completed in vitro) reporting a total of 19,590 tooth sites/surfaces. The most frequently reported classification systems were the International Caries Detection and Assessment System (ICDAS) (36 studies) and Ekstrand-Ricketts-Kidd (ERK) (15 studies). In reporting the results, no distinction was made between detection and diagnosis. Only two studies were at low risk of bias across all four domains, and 15 studies were at low concern for applicability across all three domains. The patient selection domain had the highest proportion of high risk of bias studies (49 studies). Four studies were assessed at high risk of bias for the index test domain, nine for the reference standard domain, and seven for the flow and timing domain. Due to the high number of studies on extracted teeth concerns regarding applicability were high for the patient selection and index test domains (49 and 46 studies respectively). Studies were synthesised using a hierarchical bivariate method for meta-analysis. There was substantial variability in the results of the individual studies: sensitivities ranged from 0.16 to 1.00 and specificities from 0 to 1.00. For all visual classification systems the estimated summary sensitivity and specificity point was 0.86 (95% CI 0.80 to 0.90) and 0.77 (95% CI 0.72 to 0.82) respectively, diagnostic odds ratio (DOR) 20.38 (95% CI 14.33 to 28.98). In a cohort of 1000 tooth surfaces with 28% prevalence of enamel caries, this would result in 40 being classified as disease free when enamel caries was truly present (false negatives), and 163 being classified as diseased in the absence of enamel caries (false positives). The addition of test type to the model did not result in any meaningful difference to the sensitivity or specificity estimates (Chi2(4) = 3.78, P = 0.44), nor did the addition of primary or permanent dentition (Chi2(2) = 0.90, P = 0.64). The variability of results could not be explained by tooth surface (occlusal or approximal), prevalence of dentinal caries in the sample, nor reference standard. Only one study intentionally included restored teeth in its sample and no studies reported the inclusion of sealants. We rated the certainty of the evidence as low, and downgraded two levels in total for risk of bias due to limitations in the design and conduct of the included studies, indirectness arising from the in vitro studies, and inconsistency of results. AUTHORS' CONCLUSIONS Whilst the confidence intervals for the summary points of the different visual classification systems indicated reasonable performance, they do not reflect the confidence that one can have in the accuracy of assessment using these systems due to the considerable unexplained heterogeneity evident across the studies. The prediction regions in which the sensitivity and specificity of a future study should lie are very broad, an important consideration when interpreting the results of this review. Should treatment be provided as a consequence of a false-positive result then this would be non-invasive, typically the application of fluoride varnish where it was not required, with low potential for an adverse event but healthcare resource and finance costs. Despite the robust methodology applied in this comprehensive review, the results should be interpreted with some caution due to shortcomings in the design and execution of many of the included studies. Studies to determine the diagnostic accuracy of methods to detect and diagnose caries in situ are particularly challenging. Wherever possible future studies should be carried out in a clinical setting, to provide a realistic assessment of performance within the oral cavity with the challenges of plaque, tooth staining, and restorations, and consider methods to minimise bias arising from the use of imperfect reference standards in clinical studies.
Collapse
Affiliation(s)
- Richard Macey
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Tanya Walsh
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Philip Riley
- Cochrane Oral Health, Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Anne-Marie Glenny
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Helen V Worthington
- Cochrane Oral Health, Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Lucy O'Malley
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Janet E Clarkson
- Division of Oral Health Sciences, Dundee Dental School, University of Dundee, Dundee, UK
| | | |
Collapse
|
5
|
Macey R, Walsh T, Riley P, Glenny AM, Worthington HV, Fee PA, Clarkson JE, Ricketts D. Fluorescence devices for the detection of dental caries. Cochrane Database Syst Rev 2020; 12:CD013811. [PMID: 33319353 PMCID: PMC8677328 DOI: 10.1002/14651858.cd013811] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Caries is one of the most prevalent and preventable conditions worldwide. If identified early enough then non-invasive techniques can be applied, and therefore this review focusses on early caries involving the enamel surface of the tooth. The cornerstone of caries detection is a visual and tactile dental examination, however alternative methods of detection are available, and these include fluorescence-based devices. There are three categories of fluorescence-based device each primarily defined by the different wavelengths they exploit; we have labelled these groups as red, blue, and green fluorescence. These devices could support the visual examination for the detection and diagnosis of caries at an early stage of decay. OBJECTIVES Our primary objectives were to estimate the diagnostic test accuracy of fluorescence-based devices for the detection and diagnosis of enamel caries in children or adults. We planned to investigate the following potential sources of heterogeneity: tooth surface (occlusal, proximal, smooth surface or adjacent to a restoration); single point measurement devices versus imaging or surface assessment devices; and the prevalence of more severe disease in each study sample, at the level of caries into dentine. SEARCH METHODS Cochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 30 May 2019); Embase Ovid (1980 to 30 May 2019); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 30 May 2019); and the World Health Organization International Clinical Trials Registry Platform (to 30 May 2019). We studied reference lists as well as published systematic review articles. SELECTION CRITERIA We included diagnostic accuracy study designs that compared a fluorescence-based device with a reference standard. This included prospective studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. Studies that explicitly recruited participants with caries into dentine or frank cavitation were excluded. DATA COLLECTION AND ANALYSIS Two review authors extracted data independently using a piloted study data extraction form based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Sensitivity and specificity with 95% confidence intervals (CIs) were reported for each study. This information has been displayed as coupled forest plots and summary receiver operating characteristic (SROC) plots, displaying the sensitivity-specificity points for each study. We estimated diagnostic accuracy using hierarchical summary receiver operating characteristic (HSROC) methods. We reported sensitivities at fixed values of specificity (median 0.78, upper quartile 0.90). MAIN RESULTS We included a total of 133 studies, 55 did not report data in the 2 x 2 format and could not be included in the meta-analysis. 79 studies which provided 114 datasets and evaluated 21,283 tooth surfaces were included in the meta-analysis. There was a high risk of bias for the participant selection domain. The index test, reference standard, and flow and timing domains all showed a high proportion of studies to be at low risk of bias. Concerns regarding the applicability of the evidence were high or unclear for all domains, the highest proportion being seen in participant selection. Selective participant recruitment, poorly defined diagnostic thresholds, and in vitro studies being non-generalisable to the clinical scenario of a routine dental examination were the main reasons for these findings. The dominance of in vitro studies also means that the information on how the results of these devices are used to support diagnosis, as opposed to pure detection, was extremely limited. There was substantial variability in the results which could not be explained by the different devices or dentition or other sources of heterogeneity that we investigated. The diagnostic odds ratio (DOR) was 14.12 (95% CI 11.17 to 17.84). The estimated sensitivity, at a fixed median specificity of 0.78, was 0.70 (95% CI 0.64 to 0.75). In a hypothetical cohort of 1000 tooth sites or surfaces, with a prevalence of enamel caries of 57%, obtained from the included studies, the estimated sensitivity of 0.70 and specificity of 0.78 would result in 171 missed tooth sites or surfaces with enamel caries (false negatives) and 95 incorrectly classed as having early caries (false positives). We used meta-regression to compare the accuracy of the different devices for red fluorescence (84 datasets, 14,514 tooth sites), blue fluorescence (21 datasets, 3429 tooth sites), and green fluorescence (9 datasets, 3340 tooth sites) devices. Initially, we allowed threshold, shape, and accuracy to vary according to device type by including covariates in the model. Allowing consistency of shape, removal of the covariates for accuracy had only a negligible effect (Chi2 = 3.91, degrees of freedom (df) = 2, P = 0.14). Despite the relatively large volume of evidence we rated the certainty of the evidence as low, downgraded two levels in total, for risk of bias due to limitations in the design and conduct of the included studies, indirectness arising from the high number of in vitro studies, and inconsistency due to the substantial variability of results. AUTHORS' CONCLUSIONS There is considerable variation in the performance of these fluorescence-based devices that could not be explained by the different wavelengths of the devices assessed, participant, or study characteristics. Blue and green fluorescence-based devices appeared to outperform red fluorescence-based devices but this difference was not supported by the results of a formal statistical comparison. The evidence base was considerable, but we were only able to include 79 studies out of 133 in the meta-analysis as estimates of sensitivity or specificity values or both could not be extracted or derived. In terms of applicability, any future studies should be carried out in a clinical setting, where difficulties of caries assessment within the oral cavity include plaque, staining, and restorations. Other considerations include the potential of fluorescence devices to be used in combination with other technologies and comparative diagnostic accuracy studies.
Collapse
Affiliation(s)
- Richard Macey
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Tanya Walsh
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Philip Riley
- Cochrane Oral Health, Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Anne-Marie Glenny
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Helen V Worthington
- Cochrane Oral Health, Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Patrick A Fee
- Dundee Dental School, University of Dundee, Dundee, UK
| | - Janet E Clarkson
- Division of Oral Health Sciences, Dundee Dental School, University of Dundee, Dundee, UK
| | | |
Collapse
|
6
|
Khosroshahi ME, Farahani FD, Ghazanfari L, Woll-Morison V. Dynamic characterization of indocyanine green-assisted dental caries ablation with continuous diode laser using thermal imaging and fluorescence spectroscopy. Lasers Med Sci 2020; 36:667-674. [PMID: 32772274 DOI: 10.1007/s10103-020-03118-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 08/01/2020] [Indexed: 11/21/2022]
Abstract
We describe the time-resolved thermal changes in indocyanine green (ICG)-assisted diode laser ablation of dental caries as a potential technique for painless treatment based on the selective photoabsorption and controlled photothermal ablation. Static ablation mode produced a higher temperature rise compared with scanning mode due to localized accumulation of heat. A temperature rise between 45-80 and 70-95 °C was obtained after 20 s that corresponded to 29 and 80 W cm-2, respectively. The temperature of the tooth surface increased by irradiation time, and it behaved linearly up to 70 °C at 29 and 80 W cm-2. A maximum ablation per area of about 0.3 and 0.45 mg cm-2 was achieved after 80 s exposure at 29 and 80 W cm-2, respectively. A statistically significant difference is observed in mean carious teeth weight at various exposure times between low and high irradiances. A thermal penetration depth of 0.8-9 mm is determined for 1-100 s of exposure time. The IR thermal imaging of ICG temperature as a function of exposure time showed a linear increase for 60 s beyond which it deviated. The laser-induced fluorescence spectroscopy indicated that the ICG quality can be altered during the course of irradiation, which in our case, it corresponded to ≈ 78% loss of signal within 23 min of exposure. The caries removal experiment was performed within 100 s corresponding to ≈ 7% loss. We believe that the application of the above-combined technique can be utilized as a monitoring device to control the ablation interaction process.
Collapse
Affiliation(s)
- Mohammad E Khosroshahi
- Laser & Nanobiophotonics Laboratory, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran. .,Nanobiophotonics & Biomedical Research Laboratory, MIS-Electronics Inc., Richmond Hill, Canada. .,Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada.
| | - Faezeh D Farahani
- Laser & Nanobiophotonics Laboratory, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.,Medric Teb Co., Tehran, Iran
| | - Lida Ghazanfari
- Laser & Nanobiophotonics Laboratory, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.,Eshelman School of Pharmacy, University of North Carolina-Chapel Hill, Chapel Hill, NC, USA
| | - Vaughan Woll-Morison
- Nanobiophotonics & Biomedical Research Laboratory, MIS-Electronics Inc., Richmond Hill, Canada
| |
Collapse
|
7
|
Combined Near-Infrarred Light Transillumination and Direct Digital Radiography Increases Diagnostic In Approximal Caries. Sci Rep 2019; 9:14224. [PMID: 31578410 PMCID: PMC6775139 DOI: 10.1038/s41598-019-50850-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Accepted: 09/15/2019] [Indexed: 12/03/2022] Open
Abstract
The objective of this study was to evaluate the clinical ability of Near-Infrared Light-Transillumination (NILT) for approximal dentinal caries detection and to compare with direct digital-radiography (DDR), as well as to determine whether the combination of both techniques improves the diagnostic capacity of the lesions. From 88 patients (over 18 years), 138 posterior teeth (76 molars and 62 premolars), that had approximal caries reached into dentine determined by DDR, were included. Lesion extension and DDR images were scored as follows: D0 = sound surface, D1/D2 = caries restricted to the outer/inner-half of the enamel, and D3/4 = caries restricted to the outer/inner-half of the dentin. Opening of the approximal surface using 0.5 mm-in-diameter diamond-bar was used as gold-standard. The lesion extension was then determined by the following criteria: no dentinal caries (D0/1/2) or dentinal caries (D3/4). Seventy-one lesions were D3 and 67 lesions were D4. Sensitivities of overall/D3/D4 were 98.0/95.7/100.0 (NILT) and 100/100/100 (DDR), respectively. Correlations with gold-standard were 0.92 (NILT) and 0.42 (DDR), respectively. The correlation increased to 0.97 (p = 0.045) on combining NILT and DDR. There was no difference in sensitivity between the methods (p > 0.05); but was differences in the correlation (p < 0.01). It can be concluded that NILT showed sensitivity similar to that of DDR and higher correlation than DDR for approximal dentinal caries detection. Accordingly, it may be used to monitor the progression of caries without exposing the patient to ionizing radiation, this being of particular interest in growing patients and in pregnant women. In this respect, NILT can be an effective diagnostic tool adjunctive to bitewing radiographs in detecting approximal dentinal caries. The combination of NILT and DDR represents an increase in the diagnosis of approximal lesions The proposed diagnostic protocol comprises visual examination, followed by NILT and DDR only if the former technique detects approximal caries.
Collapse
|
8
|
Alikhasi M, Zadeh BY, Mansourian A, Nokhbatolfoghahaei H. Detection of Residual Excess Zinc Oxide–Based Cement With Laser Fluorescence (DIAGNOdent): In Vitro Evaluation. J ORAL IMPLANTOL 2019; 45:89-93. [DOI: 10.1563/aaid-joi-d-17-00163] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Because of its importance in the development of peri-implant mucositis and peri-implantitis, detection of residual excess cement (REC) is often the focus of studies addressing cement-retained implant-supported restorations. The purpose of this study was to evaluate the sensitivity and specificity of laser fluorescence (DIAGNOdent) for detecting residual excess zinc oxidebased cement around dental implants. In this in vitro study, 15 tissue-level implants were embedded in acrylic resin. To simulate gingiva around the implants, the transgingival part of each implant was covered with a gingival mask silicon material. Cement (Tempobond; 1 × 1 × 1 mm) was applied to 30 areas, 4 mm below the gingival-mimicking line using a custom-made template. A DIAGNOdent laser device was used by 2 independent examiners to evaluate the presence or absence of cement in a selected area. The examiners were allowed to probe the gingival sulcus (2-mm depth) 2 times with a 5-minute interval between tests. The residual cement was recognized by gently walking the device tip around the implant. A detection score less than 16 indicated an absence of cement, and scores of 16 or greater indicated the presence of excess luting agent in the implant sulcus. The sensitivity and specificity of DIAGNOdent to detect REC in the sulcus were 100% and 96.67%, respectively. Based on our findings, we propose that DIAGNOdent could be used to detect REC in the sulcus of cement-retained implant supported restorations.
Collapse
Affiliation(s)
- Marzieh Alikhasi
- Dental Research Center, Laser Research Center, Dentistry Research Institute, School of Dentistry, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Behnoush Yaghoub Zadeh
- Laser Research Center of Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Arash Mansourian
- Department of Oral Medicine, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Hanieh Nokhbatolfoghahaei
- Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
9
|
Akgul S, Bala O, Yikilgan İ. Performance of Different Methods for Detection of Incipient Occlusal Caries Lesions: An In Vitro Study. Photomed Laser Surg 2017; 36:191-197. [PMID: 29261013 DOI: 10.1089/pho.2017.4353] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVE The aim of this in vitro study was to evaluate the diagnostic performance of visual inspection (VI), laser fluorescence (LF pen), fluorescence camera (FC), and alternating current impedance spectroscopy technique (ACIST) for detection of incipient occlusal caries lesions. Histology was used as the gold standard to determine the interexaminer reliability of the methods, among three examiners with different levels of experiences (Examiner 1: 5 years; examiner 2: 10 years; and examiner 3: 25 years). MATERIALS AND METHODS One hundred two molar teeth were selected. The occlusal surfaces of teeth were evaluated with VI, LF pen, FC, and ACIST devices independently by three examiners. Diagnostic performances of methods were evaluated with binormal receiver-operating characteristics analysis. Interexaminer agreement of detection methods was assessed using Cohen's kappa coefficient values (p < 0.001). RESULTS Incipient enamel lesions were determined more successfully with VI by all examiners. All detection methods were presented with statistically acceptable interexaminer agreement (p < 0.001). For D2 and D3 thresholds, FC for examiner 1, VI for examiner 2, and both VI and FC for examiner 3 demonstrated statistically high sensitivity and specificity (p < 0.05). CONCLUSIONS It can be concluded that diagnostic performance of the methods was insufficient for detecting incipient occlusal caries lesions by itself. Performance can be improved by using them with VI as a traditional caries detection method.
Collapse
Affiliation(s)
- Sinem Akgul
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University , Ankara, Turkey
| | - Oya Bala
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University , Ankara, Turkey
| | - İhsan Yikilgan
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University , Ankara, Turkey
| |
Collapse
|
10
|
PRESOTO CD, TREVISAN TC, ANDRADE MCD, DANTAS AAR, CAMPOS JADB, OLIVEIRA-JUNIOR OBD. Clinical effectiveness of fluorescence, digital images and ICDAS for detecting occlusal caries. REVISTA DE ODONTOLOGIA DA UNESP 2017. [DOI: 10.1590/1807-2577.12416] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Abstract Introduction The detection of small caries lesions is still a challenge for dental professionals who in their clinical practice have a wide variety of methods to detect caries on occlusal surfaces. Objective To clinically assess the effectiveness of the Vista Proof fluorescence camera, the Vista Cam digital intraoral micro camera and the International Caries Detection and Assessment System (ICDAS) visual criterion for detecting caries lesions on occlusal surfaces of permanent teeth. Material and method One hundred and seven posterior teeth from adult patients were examined visually and by means of digital radiographs by an examiner who rated them according to the presence or absence of occlusal caries. The teeth were then assessed by the other examiner using ICDAS, fluorescence and magnified digital images. The effectiveness of the methods was measured based on sensitivity, specificity, positive and negative likelihood ratio. For each method, the Receiver Operating Characteristic (ROC) curve and the Area Under the ROC curve (AUROC) were estimated. Result There was exceptional discrimination capacity for the intraoral images (AUROC=.93) and the ICDAS (AUROC=.91), with no significant statistical difference between them (z=.35, p=.73). The fluorescence exhibited an acceptable discrimination capacity (AUROC=0.78), although it was lower than the others. The positive likelihood ratio for the fluorescence was only 2.32, compared to 20.58 for the intraoral image and 58.11 for the ICDAS. Conclusion Both methods and the ICDAS exhibited an adequate clinical performance, although the ICDAS and intraoral image were more effective than the fluorescence.
Collapse
|
11
|
Rosa MI, Schambeck VS, Dondossola ER, Alexandre MC, Tuon L, Grande AJ, Hugo F. Laser fluorescence of caries detection in permanent teeth in vitro: a systematic review and meta-analysis. J Evid Based Med 2016; 9:213-224. [PMID: 27792279 DOI: 10.1111/jebm.12227] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Accepted: 06/23/2016] [Indexed: 12/01/2022]
Abstract
BACKGROUND/OBJECTIVES The detection of dental caries in the early stages, particularly on the occlusal surfaces, has become a mainstay of contemporary clinical practice. The objective of the study was to verify the accuracy of laser fluorescence for caries detection. METHODS A comprehensive search of the MEDLINE (PubMed), EMBase, Cochrane Central Register of Controlled Trials, IBECS, BIOSIS, Web of Science, SCOPUS, Congress Abstracts, and Grey literature databases was undertaken from 1980 through January 2016. We included cross-sectional studies that evaluated laser fluorescence in caries diagnoses in vitro and compared them with histological analyses. RESULTS A total of 39 articles were included in the meta-analysis, which included 2082 caries sites. The pooled sensitivity was 0.71 (0.69, 0.73), and the specificity was 0.81 (0.73, 0.82). The diagnostic odds ratio was 14.93 (11.2, 19.9). A summary receiver operating characteristic curve was constructed. The area under the curve was 0.865. CONCLUSION This meta-analysis showed that laser fluorescence in vitro had the ability to diagnose occlusal caries lesions in permanent teeth and enamel and dentin caries.
Collapse
Affiliation(s)
- Maria I Rosa
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| | - Vilson S Schambeck
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| | - Eduardo R Dondossola
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| | - Maria Cm Alexandre
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| | - Lisiane Tuon
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| | - Antonio J Grande
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| | - Fernando Hugo
- Universidade do Extremo Sul Catarinense Ringgold standard institution Criciuma, SC, Brazil
| |
Collapse
|
12
|
de Azevedo CS, Garbui BU, Martins e Silva C, Simionato Lorenzetti MR, de Freitas AZ, Matos AB. Obtaining artificially caries-affected dentin for in vitro studies. J Contemp Dent Pract 2014; 15:12-19. [PMID: 24939258 DOI: 10.5005/jp-journals-10024-1480] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
AIM This study evaluated and improved a protocol for obtaining standard caries-affected dentin (CAD) by Streptococcus mutans biofilm demineralization process. MATERIALS AND METHODS Forty-eight human molars were divided in six experimental groups, according to: period of cariogenic challenge (7, 14 or 21 days) and type of dentin (erupted or unerupted teeth). After complete cariogenic challenge sound and CAD dentin were evaluated by: visual inspection (VI), digital radiography (DR), optical coherence tomography (OCT) and laser fluorescence (LF). RESULTS Visual inspection confirmed the formation of CAD based on tissue yellowing and loss of surface gloss. Digital radiography detected the presence of radiolucent images, suggesting caries. Three calibrated examiners viewed all images obtained by VI and DR and were able to distinguish healthy from CAD. Fisher's exact statistical test (p < 0.05) confirmed no difference between groups by VI (G1/G4: p = 0.6; G2/G5: p = 1; G3/G6: p = 1) or DR (G1/G4: p = 1; G2/G5: p = 1; G3/G6: p = 1). Both LF values and demineralization depth, as determined by OCT, were subjected to ANOVA (p < 0.05). For LF, a statistically significant difference was observed for the type of substrate (p = 0.001). For OCT, no statistically significant differences in the type of substrate (p = 0.163), length of cariogenic challenge (p = 0.512) or interaction between factors (p = 0.148) were observed. Scanning electron micrographs confirmed the presence of CAD; a more uniform demineralization surface was observed in the dentin of unerupted teeth. CONCLUSION This protocol suggests that standard CAD can be obtained in 7 days of cariogenic challenge using unerupted teeth. Clinical significance: With the new perspective on the clinical treatment of caries lesions, bonding is increasingly performed to demineralize CAD, which is susceptible to remineralization. A useful protocol to standardize the production of CAD, by microbiological cariogenic challenge, would be an important contribution to laboratorial test in the field of operative dentistry.
Collapse
Affiliation(s)
| | - Bruna Uglik Garbui
- BDS, Department of Operative Dentistry, University of São Paulo São Paulo, Brazil
| | | | | | | | - Adriana Bona Matos
- Full Professor, Department of Operative Dentistry, University of São Paulo São Paulo, Brazil
| |
Collapse
|
13
|
Patel SA, Shepard WD, Barros JA, Streckfus CF, Quock RL. In vitro evaluation of Midwest Caries ID: a novel light-emitting diode for caries detection. Oper Dent 2013; 39:644-51. [PMID: 24107098 DOI: 10.2341/13-114-l] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
INTRODUCTION Traditional detection techniques have limits in diagnosing occlusal caries. Thus, more accurate methods are needed. This study evaluates the ability of the Midwest Caries ID (Midwest) to detect caries. METHODS Two hundred sixty-four extracted, nonrestored premolars and molars were cleaned and stored in 0.2% sodium azide. Teeth were divided into three groups of 88. One examination site on each occlusal surface was chosen. Each site was inspected by a calibrated examiner via visual, Midwest, and histologic exams. First, a visual exam was performed following the International Caries Detection and Assessment guidelines. Next, the same site was inspected using the Midwest device. Finally, the tooth was sectioned mesiodistally through the site. The half with greater caries progression was visualized under a stereomicroscope (64×). Histologic appearance was scored based on the Downer system. Data were analyzed using Kendall tau-b, partial correlation coefficients, and the receiver operating characteristics curve. RESULTS Overall, the Midwest scoring assessment correlated with histologic assessments (tau = 0.32; p<0.0001), but the visual exam had a stronger correlation (tau = 0.53; p<0.0001) with the histologic exam. The sensitivity and specificity of the Midwest was also reported at 0.56 and 0.84, compared with 0.92 and 0.43, respectively, for the visual exam. CONCLUSIONS Midwest Caries ID is a novel caries detection device that has limitations and should not be used as the sole means to detect occlusal caries.
Collapse
|
14
|
Gomez J, Tellez M, Pretty I, Ellwood R, Ismail A. Non-cavitated carious lesions detection methods: a systematic review. Community Dent Oral Epidemiol 2013; 41:54-66. [DOI: 10.1111/cdoe.12021] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
| | - M. Tellez
- Maurice H Kornberg School of Dentistry; Temple University; Philadelphia; PA; USA
| | - I.A. Pretty
- University of Manchester; Colgate-Palmolive Dental Health Unit; Manchester; UK
| | - R.P. Ellwood
- University of Manchester; Colgate-Palmolive Dental Health Unit; Manchester; UK
| | - A.I. Ismail
- Maurice H Kornberg School of Dentistry; Temple University; Philadelphia; PA; USA
| |
Collapse
|
15
|
Caries detection under composite restorations by laser fluorescence and digital radiography. Clin Oral Investig 2012; 17:2079-84. [DOI: 10.1007/s00784-012-0908-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2012] [Accepted: 12/05/2012] [Indexed: 10/27/2022]
|
16
|
Use of ICDAS-II, Fluorescence-Based Methods, and Radiography in Detection and Treatment Decision of Occlusal Caries Lesions: An In Vitro Study. Int J Dent 2012; 2012:371595. [PMID: 22973311 PMCID: PMC3437738 DOI: 10.1155/2012/371595] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Revised: 06/21/2012] [Accepted: 06/22/2012] [Indexed: 11/18/2022] Open
Abstract
Aim. To use visual inspection (ICDAS-II), laser fluorescence (LF), fluorescence based camera (FC) and radiographic examination (BW) for detection of caries and for treatment decision. Methods. The occlusal sites of 84 extracted permanent teeth were examined using all methods and treatment decisions (preventive or operative care) were recorded based on each method independently. For validation of the findings, fissures were opened with rotating instruments and clinical depth was determined as gold standard. Correlations (r(s)), sensitivity, specificity and AUC were calculated. McNemar test was used to show whether different methods led to significant changes in treatment decisions. Results. Highest correlation was found between ICDAS-II and FC (r(s) 0.84), ICDAS-II and gold standard (0.82) and FC and gold standard (0.81). ICDAS-II provided the highest performance (AUC 1.0), followed by FC (0.95) and LF (0.88). The greatest difference was found for treatment planning of dentine lesions, where the use of FC (cut-offs according to the literature) had the greatest agreement between operative treatment and dentine lesions, followed by use of ICDAS-II. Conclusion. ICDAS-II may have high potential for detection and treatment planning, and other devices, especially the fluorescence camera, can add substantial information to the visual examination, enabling examiners plan treatment more accurately.
Collapse
|
17
|
|
18
|
Aktan AM, Cebe MA, Ciftçi ME, Sirin Karaarslan E. A novel LED-based device for occlusal caries detection. Lasers Med Sci 2011; 27:1157-63. [PMID: 22080431 DOI: 10.1007/s10103-011-1020-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2011] [Accepted: 10/20/2011] [Indexed: 11/26/2022]
Abstract
The aim of this in-vitro study was to compare the performance of laser-based (DIAGNOdent, KaVo, Biberach, Germany) and LED-based (Midwest Caries I.D., DENTSPLY Professional, New York, USA) caries detectors in the detection of occlusal caries in permanent molars. The study consisted of 129 visually sound or non-cavitated pits or fissures in 82 extracted permanent human molar teeth. Two trained examiners used the laser-based and LED-based caries detectors to examine the fissures for caries. The teeth were then sectioned at the surfaces suspected of containing occlusal caries and histologically evaluated using stereomicroscopy as a gold standard. Inter-examiner reliability of the caries detector examination was assessed using Cohen's Kappa statistics. The sensitivity, specificity, and accuracy in diagnosing occlusal caries using the two devices were calculated according to appropriate cut-off scores. Receiver operating characteristic (ROC) curves were also determined to compare the diagnostic performance of the devices in occlusal caries diagnosis. The cut-off level of significance was taken as p = 0.005. Cohen's Kappa showed substantial agreement for the laser-based caries detector (0.74), and almost perfect agreement for the LED-based (0.89) caries detector. The specificity of the laser-based device varied from 0.49 to 0.97 at T1 and T2. Its sensitivity varied from 0.33 to 0.65 at T1 and T2. The specificity of the LED-based device varied from 0.48 to 0.56 at T1 and T2. Its sensitivity varied from 0.65 to 0.84 at T1 and from 0.80 to 0.84 at T2. Taking the limitations of the current study into consideration, the DIAGNOdent laser pen was more accurate in determining when teeth were free of occlusal caries than was the Midwest Caries I.D. LED-based device, although the Midwest Caries I.D. device more often revealed the presence of occlusal caries than did the DIAGNOdent pen.
Collapse
Affiliation(s)
- Ali Murat Aktan
- Department of Oral Diagnosis and Radiology, Faculty of Dentistry, Gaziantep University, Gaziantep, Turkey.
| | | | | | | |
Collapse
|