1
|
Yilmaz H, Keles S. The effect of the Er: YAG laser on the clinical success of hydrophilic fissure sealant: a randomized clinical trial. Eur Oral Res 2020; 54:148-153. [PMID: 33543121 PMCID: PMC7837707 DOI: 10.26650/eor.20200029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Purpose: The aim of this study was to assess the effect of the Er:YAG laser on the clinical
success of a hydrophilic fissure sealant over 12 months. Subject and methods: This study was conducted on 132 permanent first molars from 44 (19 girls and 25
boys) patients aged 7-11 years. The teeth were divided into three groups. The first
group (Group A-control) of teeth were etched with phosphoric acid, the second
group of teeth (Group L) were etched with an Er:YAG laser, and the third group of
teeth (Group A+L) were etched with both the Er:YAG laser and phosphoric acid.
Clinical evaluations were performed at baseline and at 3-, 6-, 9- and 12-month
follow-up visits. The data were analyzed with Pearson chi-square tests, Cochran Q
tests and Kaplan-Meier analysis. Results: At the end of the 12 months, total retention rates were 72.7%, 59.1%, and 65.9% in
the acid group, the laser group and the laser and acid group, respectively. Although
there was no statistically significant difference between group retention rates
(p>0.05), the lowest retention rate was found in the laser group at the end of the
12-month follow-up period. No new caries were observed in any group during the
study period. Conclusion: Etching with the Er:YAG laser, phosphoric acid or a combination of both methods
provided similar results for the clinical success of hydrophilic based fissure sealant.
Collapse
Affiliation(s)
- Hulya Yilmaz
- Bornova Oral and Dental Health Center, Izmir, Turkey
| | - Sultan Keles
- Department of Pediatric Dentistry, Faculty of Dentistry,Aydin Adnan Menderes University, Aydın,Turkey
| |
Collapse
|
2
|
AlHumaid J, Alagl AS, Bedi S. Effect of Erbium Laser on Microtensile Bond Strength of Fissure Sealant in Primary Teeth: An in vitro Study. SAUDI JOURNAL OF MEDICINE & MEDICAL SCIENCES 2019; 6:27-31. [PMID: 30787813 PMCID: PMC6196675 DOI: 10.4103/sjmms.sjmms_102_17] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Background: Laser etching has several advantages as compared with conventional acid etching. However, results of earlier studies on conditioning surfaces with erbium, chromium:yttrium–scandium–gallium–garnet (Er, Cr:YSGG) before application of the fissure sealant have been inconclusive. Aim: The study aimed to evaluate the microtensile strength of resin-based fissure sealant bonded to primary enamel conditioned by Er, Cr:YSGG laser with varying power outputs. Materials and Methods: Fifty sound primary first molars were randomized into the following five groups based on pretreatment choice: Group 1: 3.5 W laser etching + acid etching; Group 2: 2.5 W laser etching + acid etching; Group 3: 3.5 W laser etching with no acid; Group 4: 2.5 W laser etching with no acid and Group 5: acid etching with no laser. Acid etch was performed with 35% orthophosphoric acid for 30 s. Laser etching was performed with Er, Cr:YSGG (2780 nm) laser using G6 tips and 600 μm diameter, 2.5 W or 3.5 W power outputs, pulse duration of 140 μs and a repetition rate of 20 Hz. Sealant was applied on the buccal surface followed by an incremental buildup with composite resin. Microtensile bond strength was assessed and compared among the five groups using one- and two-way ANOVA. Results: There was no statistical difference in the mean bond strength between groups except in Group 4 (9.66 MPa) (Group 1: 15.57 MPa; Group 2: 14.18 MPa; Group 3: 14.78 MPa; Group 5: 14.63 MPa). Conclusion: Pretreatment with 3.5 W Er, Cr:YSGG laser alone results in microtensile bond strengths similar to that produced by acid etching, indicating that enamel etching using 3.5 W Er, Cr:YSGG laser would result in the long-term success of pit and fissure sealants in primary teeth.
Collapse
Affiliation(s)
- Jehan AlHumaid
- Department of Preventive Dental Sciences, College of Dentistry, Imam AbdulRahman Bin Faisal University, Dammam, Saudi Arabia
| | - Adel Sulaiman Alagl
- Department of Preventive Dental Sciences, College of Dentistry, Imam AbdulRahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sumit Bedi
- Department of Preventive Dental Sciences, College of Dentistry, Imam AbdulRahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
3
|
Luong E, Shayegan A. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study. Clin Cosmet Investig Dent 2018; 10:83-92. [PMID: 29881311 PMCID: PMC5985794 DOI: 10.2147/ccide.s153989] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching.
Collapse
Affiliation(s)
- Emilie Luong
- Department of Children and Adult Operative Dentistry, César de Paepe Hospital, Free University of Brussels, Bruxelles, Belgium
| | - Amir Shayegan
- Department of Children and Adult Operative Dentistry, Children's Hospital of Queen Fabiola, Free University of Brussels, Bruxelles, Belgium
| |
Collapse
|
4
|
Erdur EA, Basciftci FA. Effect of Ti:Sapphire-femtosecond laser on the surface roughness of ceramics. Lasers Surg Med 2015; 47:833-8. [DOI: 10.1002/lsm.22432] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/29/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Emire Aybuke Erdur
- Department of Orthodontics; Faculty of Dentistry; University of Selcuk; Konya Turkey
| | - Faruk Ayhan Basciftci
- Department of Orthodontics; Faculty of Dentistry; University of Selcuk; Konya Turkey
| |
Collapse
|
5
|
Erdur EA, Basciftci FA. Effect of Ti:sapphire laser on shear bond strength of orthodontic brackets to ceramic surfaces. Lasers Surg Med 2015; 47:512-9. [PMID: 25994849 DOI: 10.1002/lsm.22371] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/22/2015] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVES With increasing demand for orthodontic treatments in adults, orthodontists continue to debate the optimal way to prepare ceramic surfaces for bonding. This study evaluated the effects of a Ti:sapphire laser on the shear bond strength (SBS) of orthodontic brackets bonded to two ceramic surfaces (feldspathic and IPS Empress e-Max) and the results were compared with those using two other lasers (Er:YAG and Nd:YAG) and 'conventional' techniques, i.e., sandblasting (50 µm) and hydrofluoric (HF) acid. MATERIALS AND METHODS In total, 150 ceramic discs were prepared and divided into two groups. In each group, the following five subgroups were prepared: Ti:sapphire laser, Nd:YAG laser, Er:YAG laser, sandblasting, and HF acid. Mandibular incisor brackets were bonded using a light-cured adhesive. The samples were stored in distilled water for 24 hours at 37°C and then thermocycled. Extra samples were prepared and examined using scanning electron microscopy (SEM). SBS testing was performed and failure modes were classified. ANOVA and Tukey's HSD tests were used to compare SBS among the five subgroups (P < 0.05). RESULTS Feldspathic and IPS Empress e-Max ceramics had similar SBS values. The Ti:sapphire femtosecond laser (16.76 ± 1.37 MPa) produced the highest mean bond strength, followed by sandblasting (12.79 ± 1.42 MPa) and HF acid (11.28 ± 1.26 MPa). The Er:YAG (5.43 ± 1.21 MPa) and Nd:YAG laser (5.36 ± 1.04 MPa) groups were similar and had the lowest SBS values. More homogeneous and regular surfaces were observed in the ablation pattern with the Ti:sapphire laser than with the other treatments by SEM analysis. CONCLUSIONS Within the limitations of this in vitro study, Ti:sapphire laser- treated surfaces had the highest SBS values. Therefore, this technique may be useful for the pretreatment of ceramic surfaces as an alternative to 'conventional' techniques.
Collapse
Affiliation(s)
- Emire Aybuke Erdur
- Research Assistant, Department of Orthodontics, Faculty of Dentistry, University of Selcuk, Konya, Turkey
| | - Faruk Ayhan Basciftci
- Professor, Department of Orthodontics, Faculty of Dentistry, University of Selcuk, Konya, Turkey
| |
Collapse
|
6
|
Sungurtekin-Ekci E, Oztas N. Microtensile bond strength of a resin-based fissure sealant to Er,Cr:YSGG laser-etched primary enamel. Odontology 2015; 104:163-9. [PMID: 25847685 DOI: 10.1007/s10266-015-0203-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Accepted: 03/15/2015] [Indexed: 11/28/2022]
Abstract
The aim of this study was to evaluate the effect of Er,Cr:YSGG laser pre-treatment alone, or associated with acid-etching, on the microtensile bond strength of a resin-based fissure sealant to primary enamel. Twenty-five human primary molars were randomly divided into five groups including (1) 35 % acid etching, (2) 2.5-W laser etching, (3) 3.5-W laser etching, (4) 2.5-W laser etching + acid etching, and (5) 3.5-W laser etching + acid etching. Er,Cr:YSGG laser was used at a wavelength of 2.780 nm and pulse duration of 140-200 μs with a repetition rate of 20 Hz. Following surface pre-treatment, the fissure sealant (ClinPro™, 3M Dental Products) was applied. Each tooth was sectioned and subjected to microtensile testing. Kruskal-Wallis test was used for statistical analysis. The level of significance was set at p < 0.05. The microtensile bond strength values of group 1 were significantly higher than those of group 2, while no statistically significant difference was detected between groups 1, 3, 4, and 5. It was concluded that 3.5-W laser etching produced results comparable to conventional acid etching technique, whereas 2.5-W laser etching was not able to yield adequate bonding performance.
Collapse
Affiliation(s)
- Elif Sungurtekin-Ekci
- Faculty of Dentistry, Department of Paediatric Dentistry, Yeditepe University, Bagdat Caddesi No. 238, Goztepe, Kadikoy, 34728, Istanbul, Turkey.
| | - Nurhan Oztas
- Faculty of Dentistry, Department of Paediatric Dentistry, Gazi University, 8. Cd. 1.Sok., Emek, 06510, Ankara, Turkey
| |
Collapse
|
7
|
Guedes SFF, Melo MAS, Lima JPM, Ely C, Rôla AJ, Piva E, Rodrigues LKA. Acid Etching Concentration as a Strategy to Improve the Adhesive Performance on Er:YAG Laser and Bur-Prepared Demineralized Enamel. Photomed Laser Surg 2014; 32:379-85. [DOI: 10.1089/pho.2013.3655] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Affiliation(s)
- Sarah F. F. Guedes
- Faculty of Pharmacy, Dentistry, and Nursing, Federal University of Ceará, Rodolfo Teófilo, Brazil
| | - Mary Anne S. Melo
- Department of Endodontics, Prosthodontics, and Operative Dentistry, University of Maryland Dental School, Baltimore, Maryland
| | - Juliana PM. Lima
- Faculty of Pharmacy, Dentistry, and Nursing, Federal University of Ceará, Rodolfo Teófilo, Brazil
| | - Caroline Ely
- Biomaterials Development and Control Center (CDC-Bio), School of Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | - Antero J.S. Rôla
- Faculty of Pharmacy, Dentistry, and Nursing, Federal University of Ceará, Rodolfo Teófilo, Brazil
| | - Evandro Piva
- Biomaterials Development and Control Center (CDC-Bio), School of Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | - Lidiany K. A. Rodrigues
- Faculty of Pharmacy, Dentistry, and Nursing, Federal University of Ceará, Rodolfo Teófilo, Brazil
| |
Collapse
|
8
|
Borsatto MC, Giuntini JDL, Contente MMMG, Gomes-Silva JM, Torres CP, Galo R. Self-etch bonding agent beneath sealant: Bond strength for laser-irradiated enamel. Eur J Dent 2014; 7:289-295. [PMID: 24926208 PMCID: PMC4053617 DOI: 10.4103/1305-7456.115412] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVES This study evaluated the in vitro shear bond strength (SBS) of a resin-based pit-and-fissure sealant (Fluroshield [F], Dentsply/Caulk) associated with either an etch-and-rinse (Adper Single Bond 2 [SB], 3M/ESPE) or a two-step self-etch adhesive system (Adper SE Plus [SE], 3M/ESPE) on Er: YAG laser-irradiated enamel. MATERIALS AND METHODS Seventeen sound third molar crowns were embedded in acrylic resin, and the mesial-distal enamel surfaces were flattened. The enamel sites were irradiated with a 2.94-μm wavelength Er: YAG laser (120 mJ, 4 Hz, noncontact mode/17 mm, 20 s). The specimens were randomly assigned to three groups according to the bonding technique: I - 37% phosphoric acid etching + SB + F; II - SE + F and III - F applied to acid-etched enamel, without an intermediate layer of bonding agent. In all of the groups, a 3-mm diameter enamel-bonding site was demarcated and the sealant cylinders were bonded. After 24 hours in distilled water, the shear bond strength was tested at a crosshead speed of 0.5 mm/minute. The data were analyzed by one-way ANOVA and Tukey's test. The debonded specimens were examined with a stereomicroscope to assess the failure modes. RESULTS The mean SBS values in MPa were I = 6.39 (±1.44); II = 9.50 (±2.79); and III = 5.26 (±1.82). No statistically significant differences were observed between groups I and III; SE/F presented a significantly higher SBS than that of the other groups (P = 0.001). With regard to the failure mode, groups I (65%) and II (75%) presented adhesive failures, while group III showed 50% adhesive failure. Cohesive failure did not occur. CONCLUSION The application of the two-step self-etch bonding agent (Adper SE Plus) beneath the resin pit-and-fissure sealant placement resulted in a significantly higher bond strength for the Er:YAG laser-irradiated enamel.
Collapse
Affiliation(s)
- Maria Cristina Borsatto
- Department of Pediatric Clinics, Preventive and Community Dentistry, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-904, Brazil
| | - Jackelline de Lemes Giuntini
- Department of Pediatric Clinics, Preventive and Community Dentistry, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-904, Brazil
| | - Marta Maria Martins Giamatei Contente
- Department of Pediatric Clinics, Preventive and Community Dentistry, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-904, Brazil
| | - Jaciara Miranda Gomes-Silva
- Department of Pediatric Clinics, Preventive and Community Dentistry, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-904, Brazil
| | - Carolina Paes Torres
- Department of Pediatric Clinics, Preventive and Community Dentistry, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-904, Brazil
| | - Rodrigo Galo
- Department of Dental Materials and Prostheses, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, 14040-904, Brazil
| |
Collapse
|
9
|
UNAL M, HUBBEZOGLU I, ZAN R, OZNURHAN F. The effect of Er:YAG laser and different surface conditioning procedures on microtensile bond strength of the fissure sealant containing amorphous calcium phosphate after artificial aging. Dent Mater J 2014; 33:21-6. [DOI: 10.4012/dmj.2013-176] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
10
|
Pires PT, Ferreira JC, Oliveira SA, Azevedo AF, Dias WR, Melo PR. Shear bond strength and SEM morphology evaluation of different dental adhesives to enamel prepared with ER:YAG laser. Contemp Clin Dent 2013; 4:20-6. [PMID: 23853447 PMCID: PMC3703689 DOI: 10.4103/0976-237x.111588] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
CONTEXT Early observations of enamel surfaces prepared by erbium lasers motivated clinicians to use laser as an alternative to chemical etching. AIMS Evaluate shear bond strength (SBS) values of different dental adhesives on Erbium:Yttrium Aluminum Garnet (Er:YAG) laser prepared enamel and to evaluate possible etching patterns correlations between dental adhesives and SBS values. SUBJECTS AND METHODS One hundred bovine incisors were randomly assigned to SBS tests on enamel (n = 15) and to enamel morphology analysis (n = 5) after Er:YAG laser preparation as follows: Group I - 37% phosphoric acid (PA)+ ExciTE(®); Group II - ExciTE(®); Group III - AdheSE(®) self-etching; Group IV - FuturaBond(®) no-rinse. NR; Group V - Xeno(®) V. Teeth were treated with the adhesive systems and subjected to thermal cycling. SBS were performed in a universal testing machine at 5 mm/min. STATISTICAL ANALYSIS USED One-way ANOVA and post-hoc tests (P < 0.05). For the morphology evaluation, specimens were immersed in Ethylenediamine tetraacetic acid (EDTA) and the etching pattern analyzed under Scanning Electron Microscope (SEM). RESULTS Mean bond strengths were Group I - 47.17 ± 1.61 MPa (type I etching pattern); Group II - 32.56 ± 1.64 MPa, Group III - 29.10 ± 1.34 MPa, Group IV - 23.32 ± 1.53 MPa (type III etching pattern); Group V - 24.43 MPa ± 1.55 (type II etching pattern). CONCLUSIONS Different adhesive systems yielded significantly different SBSs. Acid etching significantly increased the adhesion in laser treated enamel. No differences in SBS values were obtained between AdheSE(®) and ExciTE(®) without condition with PA. FuturaBond(®) NR and Xeno(®) V showed similar SBS, which was lower in comparison to the others adhesives. No correlation between enamel surface morphology and SBS values was observed, except when PA was used.
Collapse
Affiliation(s)
- Patrícia T Pires
- Department of Operative Dentistry, Faculty of Dentistry, University of Porto, Porto, Portugal
| | | | | | | | | | | |
Collapse
|