1
|
Hart I, Wells C, Tsigarida A, Bezerra B. Effectiveness of mechanical and chemical decontamination methods for the treatment of dental implant surfaces affected by peri-implantitis: A systematic review and meta-analysis. Clin Exp Dent Res 2024; 10:e839. [PMID: 38345466 PMCID: PMC10847712 DOI: 10.1002/cre2.839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 12/20/2023] [Accepted: 12/30/2023] [Indexed: 02/15/2024] Open
Abstract
OBJECTIVE To assess which decontamination method(s) used for the debridement of titanium surfaces (disks and dental implants) contaminated with bacterial, most efficiently eliminate bacterial biofilms. MATERIAL AND METHODS A systematic search was conducted in four electronic databases between January 1, 2010 and October 31, 2022. The search strategy followed the PICOS format and included only in vitro studies completed on either dental implant or titanium disk samples. The assessed outcome variable consisted of the most effective method(s)-chemical or mechanical- removing bacterial biofilm from titanium surfaces. A meta-analysis was conducted, and data was summarized through single- and multi-level random effects model (p < .05). RESULTS The initial search resulted in 5260 articles after the removal of duplicates. After assessment by title, abstract, and full-text review, a total of 13 articles met the inclusion criteria for this review. Different decontamination methods were assessed, including both mechanical and chemical, with the most common method across studies being chlorhexidine (CHX). Significant heterogeneity was noted across the included studies. The meta-analyses only identified a significant difference in biofilm reduction when CHX treatment was compared against PBS. The remaining comparisons did not identify significant differences between the various decontamination methods. CONCLUSIONS The present results do not demonstrate that one method of decontamination is superior in eliminating bacterial biofilm from titanium disk and implant surfaces.
Collapse
Affiliation(s)
- Iain Hart
- Department of Periodontology, Eastman Institute for Oral HealthUniversity of RochesterRochesterNew YorkUSA
| | - Christine Wells
- Statistical Methods and Data AnalyticsUCLA Office of Advanced Research ComputingLos AngelesCaliforniaUSA
| | - Alexandra Tsigarida
- Department of Periodontology, Eastman Institute for Oral HealthUniversity of RochesterRochesterNew YorkUSA
| | - Beatriz Bezerra
- Section of Periodontics, Division of Regenerative and Reconstructive SciencesUCLA School of DentistryLos AngelesCaliforniaUSA
| |
Collapse
|
2
|
Han J, Ma Q, An Y, Wu F, Zhao Y, Wu G, Wang J. The current status of stimuli-responsive nanotechnologies on orthopedic titanium implant surfaces. J Nanobiotechnology 2023; 21:277. [PMID: 37596638 PMCID: PMC10439657 DOI: 10.1186/s12951-023-02017-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 07/21/2023] [Indexed: 08/20/2023] Open
Abstract
With the continuous innovation and breakthrough of nanomedical technology, stimuli-responsive nanotechnology has been gradually applied to the surface modification of titanium implants to achieve brilliant antibacterial activity and promoted osteogenesis. Regarding to the different physiological and pathological microenvironment around implants before and after surgery, these surface nanomodifications are designed to respond to different stimuli and environmental changes in a timely, efficient, and specific way/manner. Here, we focus on the materials related to stimuli-responsive nanotechnology on titanium implant surface modification, including metals and their compounds, polymer materials and other materials. In addition, the mechanism of different response types is introduced according to different activation stimuli, including magnetic, electrical, photic, radio frequency and ultrasonic stimuli, pH and enzymatic stimuli (the internal stimuli). Meanwhile, the associated functions, potential applications and developing prospect were discussion.
Collapse
Affiliation(s)
- Jingyuan Han
- Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, 710032 China
- School of Stomatology, Heilongjiang Key Lab of Oral Biomedicine Materials and Clinical Application, Experimental Center for Stomatology Engineering, Jiamusi University, Jiamusi, 154007 China
| | - Qianli Ma
- Department of Biomaterials, Institute of Clinical Dentistry, University of Oslo, Geitmyrsveien, Oslo, 710455 Norway
| | - Yanxin An
- Department of General Surgery, The First Affiliated Hospital of Xi’an Medical University, Xi’an, China
| | - Fan Wu
- Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, 710032 China
- School of Stomatology, Heilongjiang Key Lab of Oral Biomedicine Materials and Clinical Application, Experimental Center for Stomatology Engineering, Jiamusi University, Jiamusi, 154007 China
| | - Yuqing Zhao
- Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, 710032 China
- School of Stomatology, Heilongjiang Key Lab of Oral Biomedicine Materials and Clinical Application, Experimental Center for Stomatology Engineering, Jiamusi University, Jiamusi, 154007 China
| | - Gaoyi Wu
- School of Stomatology, Heilongjiang Key Lab of Oral Biomedicine Materials and Clinical Application, Experimental Center for Stomatology Engineering, Jiamusi University, Jiamusi, 154007 China
| | - Jing Wang
- Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, 710032 China
| |
Collapse
|
3
|
Gulati K, Chopra D, Kocak-Oztug NA, Verron E. Fit and forget: The future of dental implant therapy via nanotechnology. Adv Drug Deliv Rev 2023; 199:114900. [PMID: 37263543 DOI: 10.1016/j.addr.2023.114900] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/11/2023] [Accepted: 05/21/2023] [Indexed: 06/03/2023]
Abstract
Unlike orthopedic implants, dental implants require the orchestration of both osseointegration at the bone-implant interface and soft-tissue integration at the transmucosal region in a complex oral micro-environment with ubiquitous pathogenic bacteria. This represents a very challenging environment for early acceptance and long-term survival of dental implants, especially in compromised patient conditions, including aged, smoking and diabetic patients. Enabling advanced local therapy from the surface of titanium-based dental implants via novel nano-engineering strategies is emerging. This includes anodized nano-engineered implants eluting growth factors, antibiotics, therapeutic nanoparticles and biopolymers to achieve maximum localized therapeutic action. An important criterion is balancing bioactivity enhancement and therapy (like bactericidal efficacy) without causing cytotoxicity. Critical research gaps still need to be addressed to enable the clinical translation of these therapeutic dental implants. This review informs the latest developments, challenges and future directions in this domain to enable the successful fabrication of clinically-translatable therapeutic dental implants that would allow for long-term success, even in compromised patient conditions.
Collapse
Affiliation(s)
- Karan Gulati
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia.
| | - Divya Chopra
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia
| | - Necla Asli Kocak-Oztug
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia; Istanbul University, Faculty of Dentistry, Department of Periodontology, 34116 Istanbul, Turkey
| | - Elise Verron
- Nantes Université, CNRS, CEISAM, UMR 6230, 44000 Nantes, France
| |
Collapse
|
4
|
Bayrak M, Kocak-Oztug NA, Gulati K, Cintan S, Cifcibasi E. Influence of Clinical Decontamination Techniques on the Surface Characteristics of SLA Titanium Implant. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4481. [PMID: 36558334 PMCID: PMC9784882 DOI: 10.3390/nano12244481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/04/2022] [Accepted: 12/12/2022] [Indexed: 06/17/2023]
Abstract
The study aims: 1. To perform diode laser, titanium (Ti) brush, and Ti curette treatment on sandblasted and acid-etched (SLA) Ti surfaces, with/without H2O2 and CHX, 2. To investigate the influence of decontamination techniques on implant surface topography and hydrophilicity. Diode laser, Ti brush, and Ti curette treatments were performed on the Grade 4 Ti discs, with/without treatment with 3% H2O2 solution or 0.2% CHX. Surface characteristics were investigated via SEM, optical profilometry, and water contact angle meter. SEM findings revealed flat and scratched areas when treated with Ti curette and Ti brush. For diode laser, SEM showed melting in specific areas. Ra and Rt values were lower in all test groups than in the control group (p < 0.05). The adjunctive chemical treatment showed negligible effects in SEM images and surface roughness measurements compared to laser and mechanical treatment-only groups. H2O2 treatment resulted in enhanced hydrophilicity in either treatment modalities with a significant difference compared to the negative control group (p < 0.05). In all test groups, the hydrophilicity was enhanced compared to the negative control group (p < 0.05). Diode laser treatment had the least disruptive effect on the Ti surface characteristics. The use of other mechanical methods caused significant alterations in the surface roughness.
Collapse
Affiliation(s)
- Meltem Bayrak
- Faculty of Dentistry, Department of Periodontology, Istanbul University, Istanbul 34116, Turkey
- Institute of Graduate Studies in Health Sciences, Department of Periodontology, Istanbul University, Istanbul 34126, Turkey
| | - Necla Asli Kocak-Oztug
- Faculty of Dentistry, Department of Periodontology, Istanbul University, Istanbul 34116, Turkey
- School of Dentistry, The University of Queensland, Herston, QLD 4006, Australia
| | - Karan Gulati
- School of Dentistry, The University of Queensland, Herston, QLD 4006, Australia
| | - Serdar Cintan
- Faculty of Dentistry, Department of Periodontology, Istanbul University, Istanbul 34116, Turkey
| | - Emine Cifcibasi
- Faculty of Dentistry, Department of Periodontology, Istanbul University, Istanbul 34116, Turkey
| |
Collapse
|
5
|
Dhaliwal JS, Abd Rahman NA, Ming LC, Dhaliwal SKS, Knights J, Albuquerque Junior RF. Microbial Biofilm Decontamination on Dental Implant Surfaces: A Mini Review. Front Cell Infect Microbiol 2021; 11:736186. [PMID: 34692562 PMCID: PMC8531646 DOI: 10.3389/fcimb.2021.736186] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 09/09/2021] [Indexed: 11/25/2022] Open
Abstract
Introduction After insertion into the bone, implants osseointegrate, which is required for their long-term success. However, inflammation and infection around the implants may lead to implant failure leading to peri-implantitis and loss of supporting bone, which may eventually lead to failure of implant. Surface chemistry of the implant and lack of cleanliness on the part of the patient are related to peri-implantitis. The only way to get rid of this infection is decontamination of dental implants. Objective This systematic review intended to study decontamination of microbial biofilm methods on titanium implant surfaces used in dentistry. Methods The electronic databases Springer Link, Science Direct, and PubMed were explored from their inception until December 2020 to identify relevant studies. Studies included had to evaluate the efficiency of new strategies either to prevent formation of biofilm or to treat matured biofilm on dental implant surfaces. Results and Discussion In this systematic review, 17 different groups of decontamination methods were summarized from 116 studies. The decontamination methods included coating materials, mechanical cleaning, laser treatment, photodynamic therapy, air polishing, anodizing treatment, radiation, sonication, thermal treatment, ultrasound treatment, chemical treatment, electrochemical treatment, antimicrobial drugs, argon treatment, and probiotics. Conclusion The findings suggest that most of the decontamination methods were effective in preventing the formation of biofilm and in decontaminating established biofilm on dental implants. This narrative review provides a summary of methods for future research in the development of new dental implants and decontamination techniques.
Collapse
Affiliation(s)
- Jagjit Singh Dhaliwal
- Pengiran Anak Puteri Rashidah Sa'adatul Bolkiah Institute of Health Sciences, Universiti Brunei, Darussalam, Gadong, Brunei
| | - Nurul Adhwa Abd Rahman
- Pengiran Anak Puteri Rashidah Sa'adatul Bolkiah Institute of Health Sciences, Universiti Brunei, Darussalam, Gadong, Brunei
| | - Long Chiau Ming
- Pengiran Anak Puteri Rashidah Sa'adatul Bolkiah Institute of Health Sciences, Universiti Brunei, Darussalam, Gadong, Brunei
| | - Sachinjeet Kaur Sodhi Dhaliwal
- Pengiran Anak Puteri Rashidah Sa'adatul Bolkiah Institute of Health Sciences, Universiti Brunei, Darussalam, Gadong, Brunei
| | - Joe Knights
- Pengiran Anak Puteri Rashidah Sa'adatul Bolkiah Institute of Health Sciences, Universiti Brunei, Darussalam, Gadong, Brunei
| | | |
Collapse
|
6
|
Bacterial reduction effect of four different dental lasers on titanium surfaces in vitro. Lasers Med Sci 2021; 36:1759-1767. [PMID: 34313893 DOI: 10.1007/s10103-021-03349-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 06/07/2021] [Indexed: 10/20/2022]
Abstract
Compare the effectiveness of selected dental lasers for decontamination of machined titanium surfaces in vitro. Seventy-two sterile machined surface titanium discs were individually inoculated with strains of Streptococcus mutans (Sm), Streptococcus oralis (So), Aggregatibacter actinomycetemcomitans (Aa), or all three bacteria together (MIX) at 34.0° C, 20.8% O2 and 5% CO2 for 12 h. After incubation, the discs were divided into six groups: 1) no treatment, 2) 0.12% chlorhexidine gluconate (CHX), and 3) 10,600 CO2, 4) 810 nm diode, 5) 2780 nm Er,Cr:YSGG, 6) 1064 nm Nd:YAG laser groups. After treatment, any remaining viable bacteria were liberated from the discs via sonication, transferred onto brain heart infusion (BHI) agar plates for culturing, and colony-forming units (CFUs) were recorded. Statistical analysis was performed. There were statistically significantly differences (SSD) (p < 0.01) in bacterial reduction of discs individually inoculated with Aa between the Er,Cr:YSGG and Nd:YAG lasers. There was also a SSD (p < 0.01) lower effect with the MIX with the Er,Cr:YSGG compared with all other modalities. Bacterial reduction with the CO2 was better (p < 0.001) than treatment with CHX or the Er,Cr:YSGG laser on killing of So. Although all modalities of treatment showed a mean of 98% or greater viable bacterial reduction, the most consistent bacterial reduction of all titanium discs was with the Nd:YAG laser (100%).
Collapse
|
7
|
Park SH, Kim OJ, Chung HJ, Kim OS. Effect of a Er, Cr:YSGG laser and a Er:YAG laser treatment on oral biofilm-contaminated titanium. J Appl Oral Sci 2020; 28:e20200528. [PMID: 33263649 PMCID: PMC7714262 DOI: 10.1590/1678-7757-2020-0528] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 08/31/2020] [Indexed: 02/07/2023] Open
Abstract
OBJECTIVE Implant surface decontamination is a challenging procedure for therapy of peri-implant disease. This study aimed to compare the effectiveness of decontamination on oral biofilm-contaminated titanium surfaces in Er:YAG laser, Er, Cr:YSGG laser, and plastic curette. METHODOLOGY For oral biofilms formation, six participants wore an acrylic splint with eight titanium discs in the maxillary arch for 72 hours. A total of 48 contaminated discs were distributed among four groups: untreated control; decontamination with plastic curettes; Er, Cr:YSGG laser; and Er:YAG laser irradiation. Complete plaque removal was estimated using naked-eye and the time taken was recorded; the residual plaque area was measured and the morphological alteration of the specimen surface was observed by scanning electron microscopy. The total bacterial load and the viability of adherent bacteria were quantified by live or dead cell labeling with fluorescence microscopy. RESULTS The mean treatment time significantly decreased based on the treatment used in the following order: Er:YAG, Er, Cr:YSGG laser, and plastic curettes (234.9±25.4 sec, 156.1±12.7 sec, and 126.4±18.6 sec, P=0.000). The mean RPA in the Er, Cr:YSGG laser group (7.0±2.5%) was lower than Er:YAG and plastic curettes groups (10.3±2.4%, 12.3±3.6%, p=0.023). The viable bacteria on the titanium surface after Er, Cr:YSGG laser irradiation was significantly lower compared to the decontamination with plastic curette (P=0.05) but it was not significantly different from the Er:YAG laser irradiation. CONCLUSION We found that Er:YAG laser and Er, Cr:YSGG laser irradiation were effective methods for decontaminations without surface alterations.
Collapse
Affiliation(s)
- So-Hyun Park
- Chonnam National University, School of Dentistry, Dental Science Research Institute, Department of Periodontology, Gwangju, Republic of Korea
| | - Ok-Joon Kim
- Department of Oral Pathology, National University, School of Dentistry Chonnam, Gwangju, Republic of Korea
| | - Hyun-Ju Chung
- Chonnam National University, School of Dentistry, Dental Science Research Institute, Department of Periodontology, Gwangju, Republic of Korea
| | - Ok-Su Kim
- Chonnam National University, School of Dentistry, Hard-tissue Biointerface Research Center, Department of Periodontology, Gwangju, Republic of Korea
| |
Collapse
|
8
|
Balderrama ÍDF, Stuani VDT, Cardoso MV, Oliveira RC, Lopes MMR, Greghi SLA, Adriana Campos Passanezi S. The influence of implant surface roughness on decontamination by antimicrobial photodynamic therapy and chemical agents: A preliminary study in vitro. Photodiagnosis Photodyn Ther 2020; 33:102105. [PMID: 33217567 DOI: 10.1016/j.pdpdt.2020.102105] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 10/06/2020] [Accepted: 11/13/2020] [Indexed: 11/17/2022]
Abstract
BACKGROUND The aim of this preliminary study was to analyze the effectiveness of three different protocols of decontamination on five commercial moderate rough implants. MATERIAL AND METHODS The types of implants investigated were: Neoporos Drive CM (CM; Neodent®), Drive CM Acqua (ACQ; Neodent®), SLActive (SLA; Straumann®), Osseotite (OT; Biomet 3i®) and Nanotite (NT; Biomet 3i®). Implant surface properties (n = 2/type of implant; control groups) were analyzed by scanning electron microscopy (SEM) images to determine surface roughness parameters (SRP) and energy disperse X-ray spectrometry to determine the chemical composition. Implants were then inoculated with Aggregatibacter actinomycetencomitans in vitro (n = 6/type of implant;experimental groups) and the contaminated areas were determined in SEM images (500x magnifications). Decontamination of implants was performed in duplicate by three protocols: antimicrobial photodynamic therapy (aPDT), EDTA associated with citric acid (EDTA + CA) and 0.12 % chlorhexidine (CHX). The remaining contaminated area (rCtA) was determined in SEM images (500x magnifications). All quantitative analysis through SEM images were analyzed in ImageJ® software for two-dimensional parameters. RESULTS No significant differences were found in SRP among implants (control group), except for Rv (lowest valley) between SLA vs. OT (p=0.0031; Kruskal Wallis post hoc Dunn). NT implants showed highest contaminated area vs. ACQ implants (68.19 % ± 8.63 % and 57.32 % ± 5.38 %, respectively; p = 0.0016, Tukey's test). SRP after decontamination showed statistical difference for Ra (arithmetical mean deviation) for all decontamination groups when compared to control (p < 0.05; ANOVA with post-hoc Tukey's multiple comparisons test), only CM implants showed statistical difference when compared decontamination protocols to control with highest modification of SRP for EDTA + AC group. For decontamination analysis, for applicability of different protocols in the same type of implant, only SLA showed statistical significant difference for aPDT vs. EDTA + CA (p = 0.0114; ANOVA with post-hoc Tukey's multiple comparisons test) with lowest rCTA for aPDT, however for ACQ implants the aPDT showed lowest rCTA with no statistical difference (p > 0.05; ANOVA with post-hoc Tukey's multiple comparisons test). No statistical difference was observed between the decontamination protocols at other implant types. CONCLUSION It can be suggested that the chemical-physical characteristics of dental implants can be effected by the process of contamination and decontamination by aPDT and chemical agents.
Collapse
Affiliation(s)
- Ísis de Fátima Balderrama
- Department of Diagnosis and Surgery, Araraquara School of Dentistry, Sao Paulo State University, Araraquara, SP, Brazil; Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil.
| | - Vitor de Toledo Stuani
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil.
| | - Matheus Völz Cardoso
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil.
| | - Rodrigo Cardoso Oliveira
- Department of Biological Science, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil.
| | | | - Sebastião Luiz Aguiar Greghi
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil.
| | | |
Collapse
|
9
|
Nitride-Coated and Anodic-Oxidized Titanium Promote a Higher Fibroblast and Reduced Streptococcus gordonii Proliferation Compared to the Uncoated Titanium. PROSTHESIS 2020. [DOI: 10.3390/prosthesis2040031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Titanium shows optimal biocompatibility properties; however, its gray color may be a limit for aesthetic results of dental rehabilitations. Some surface treatments that change the color of the material have been proposed. The aim of this study is to, in vitro, investigate the biocompatibility of the surfaces subjected to titanium nitride (NiT) coating and anodic-oxidized (AO) treatment and their propensity to impair bacterial proliferation. The viability of primary human gingival fibroblasts (HGFs) has been evaluated through a methyl thiazolyl tetrazolium (MTT) assay in three experimental groups: uncoated titanium (UNCOATED), titanium nitride (NiT)-coated surface, and anodic-oxidized (AO) titanium. Bacterial proliferation experiments were performed using a Streptococcus gordonii clinical isolate in contact with the three different above-mentioned materials. The treated surfaces (NiT and AO) showed a significantly higher fibroblast proliferation than the uncoated titanium alloy (p < 0.05). In contrast, Streptococcus gordonii growth was significantly higher on the untreated titanium (p < 0.05).
Collapse
|
10
|
Wu H, Xie L, He M, Zhang R, Tian Y, Liu S, Gong T, Huo F, Yang T, Zhang Q, Guo S, Tian W. A wear-resistant TiO 2 nanoceramic coating on titanium implants for visible-light photocatalytic removal of organic residues. Acta Biomater 2019; 97:597-607. [PMID: 31398472 DOI: 10.1016/j.actbio.2019.08.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 07/25/2019] [Accepted: 08/02/2019] [Indexed: 12/18/2022]
Abstract
An effective treatment for peri-implantitis is to completely remove all the bacterial deposits from the contaminated implants, especially the organic residues, to regain biocompatibility and re-osseointegration, but none of the conventional decontamination treatments has achieve this goal. The photocatalytic activity of TiO2 coating on titanium implants to degrade organic contaminants has attracted researchers' attention recently. But a pure TiO2 coating only responses to harmful ultraviolet light. Additionally, the poor coating mechanical properties are unable to protect the coating integrity versus initial mechanical decontamination. To address these issues, a unique TiO2 nanoceramic coating was fabricated on titanium substrates through an innovative plasma electrolytic oxidation (PEO) based procedure, which showed a disordered layer with oxygen vacancies on the outmost part. As a result, the coating could decompose methylene blue, rhodamine B, and pre-adsorbed lipopolysaccharide (LPS) under visible light. Additionally, the coating showed two-fold higher hardness than untreated titanium and excellent wear resistance against steel decontamination instruments, which could be attributed to the specific micro-structure, including the densely packed nanocrystals and good metallurgical combination. Moreover, the in vitro response of MG63 cells confirmed that the coating had comparable biocompatibility and osteoconductivity to untreated titanium substrates. This study provides a unique coating technique as well as a photocatalytic cleaning strategy to enhance decontamination of titanium dental implants, which will favour the development of peri-implantitis treatments. STATEMENT OF SIGNIFICANCE: The treatment of peri-implantitis is based on the complete removal of bacterial deposits, especially the organic residues, but conventional decontamination treatments are hard to achieve it. The photocatalytic activity of TiO2 coating on titanium implants to degrade organic contaminants provides a promising strategy for deeper decontamination, but its nonactivation to visible light and poor mechanical properties have limited its application. To address these issues, a unique TiO2 nanoceramic coating was fabricated on titanium substrates based on plasma electrolytic oxidation. The coating showed enhanced visible-light photocatalytic activity, excellent wear resistance and satisfied biocompatibility. Based on this functional coating, it is promising to develop a more efficient strategy for deep decontamination of implant surface, which will favour the development of peri-implantitis treatments.
Collapse
|
11
|
Benli M, Petit C, Tenenbaum H, Huck O. In vitro Assessment of Peri-implantitis Treatment Procedures: A Review. Open Dent J 2019. [DOI: 10.2174/1874210601913010267] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background:
The prevalence of peri-implantitis is increasing continuously and such a biological complication significantly decreases implant survival and success. Although various treatment modalities have been identified for peri-implantitis, no completely efficient method has yet been established.
Objective:
The aim of this review was to evaluate the scientific literature regarding the in vitro effects of peri-implantitis treatment.
Methods:
A review of the literature was performed by using Google Scholar, PubMed/ MEDLINE and Science Direct databases. In vitro studies on peri-implantitis treatment modalities were selected. The search strategy identified 57 eligible studies. After selection, 21 articles met all the inclusion criteria and were included in the present review.
Results:
Included in vitro studies evaluated different types of peri-implantitis treatment modalities such as mechanical, chemical, combination and laser therapies. Combination therapies with the aid of adjuvants were found to be more effective compared to the studies that used only one type of treatment modality. Laser systems were also tested and displayed interesting results in terms of surface decontamination with a variability associated with selected parameters.
Conclusion:
This review was performed to evaluate the efficacy of the treatment modalities used for peri-implantitis in vitro. Although there are various effective treatment methods, none has been completely successful in removing the biofilms related to peri-implantitis. The findings imply the need for further studies to develop more effective antimicrobial treatment procedures.
Collapse
|
12
|
Alagl AS, Madi M, Bedi S, Al Onaizan F, Al-Aql ZS. The Effect of Er,Cr:YSGG and Diode Laser Applications on Dental Implant Surfaces Contaminated with Acinetobacter Baumannii and Pseudomonas Aeruginosa. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E2073. [PMID: 31252629 PMCID: PMC6651164 DOI: 10.3390/ma12132073] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 06/20/2019] [Accepted: 06/25/2019] [Indexed: 12/17/2022]
Abstract
Treatment of peri-implantitis through several implant surface decontamination techniques have been reported, however, some of them can negatively alter the implant surface or enhance more bacterial resistance. The aim of this in vitro study was to evaluate implant surface decontamination by means of Er,Cr:YSGG and diode lasers. Fifty micro-textured (MTX) dental implants were contaminated with Acinetobacter baumannii (n = 25) and with Pseudomonas aeruginosa (n = 25). All implants were then divided into five groups for the decontamination procedure. In group I (GI), decontamination was done with an Er,Cr:YSGG laser (2780 nm), while in group II (GII) decontamination was performed using photodynamic therapy (a 650 nm diode laser). In Group III (GIII) decontamination was performed with photodynamic therapy (an 808 nm diode laser), and in group IV (GIV) decontamination was performed with 0.12% chlorhexidine. Group V (GV) was the control group with no decontamination. After decontamination, colony forming units (CFU) were counted and implants were prepared for SEM analysis. A significant difference (p < 0.001) was observed for GI compared to the other groups, and also for GIV compared to both GII and GIII. The Er,Cr:YSGG laser (GI) showed the best results in decontaminating the implant surface. Chlorhexidine (GIV), proved to be better in decontaminating the implant surface than photodynamic therapy GII and diode laser GIII. No significant difference was found between group GII and GIII. The SEM analysis showed no significant change in the implant surface topography. The results of this study suggest that the Er,Cr:YSGG laser can be considered as an effective technique for reducing bacteria contamination on implant surfaces.
Collapse
Affiliation(s)
- Adel S Alagl
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia.
| | - Sumit Bedi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Faisal Al Onaizan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Zainab S Al-Aql
- Dental Services, King Abdulaziz Medical City, National Guard Health Affairs, Jeddah 21423, Saudi Arabia
| |
Collapse
|
13
|
Khatoon Z, McTiernan CD, Suuronen EJ, Mah TF, Alarcon EI. Bacterial biofilm formation on implantable devices and approaches to its treatment and prevention. Heliyon 2018; 4:e01067. [PMID: 30619958 PMCID: PMC6312881 DOI: 10.1016/j.heliyon.2018.e01067] [Citation(s) in RCA: 551] [Impact Index Per Article: 91.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Revised: 12/17/2018] [Accepted: 12/17/2018] [Indexed: 02/06/2023] Open
Abstract
In living organisms, biofilms are defined as complex communities of bacteria residing within an exopolysaccharide matrix that adheres to a surface. In the clinic, they are typically the cause of chronic, nosocomial, and medical device-related infections. Due to the antibiotic-resistant nature of biofilms, the use of antibiotics alone is ineffective for treating biofilm-related infections. In this review, we present a brief overview of concepts of bacterial biofilm formation, and current state-of-the-art therapeutic approaches for preventing and treating biofilms. Also, we have reviewed the prevalence of such infections on medical devices and discussed the future challenges that need to be overcome in order to successfully treat biofilms using the novel technologies being developed.
Collapse
Affiliation(s)
- Zohra Khatoon
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, K1Y 4W7, Canada
| | - Christopher D. McTiernan
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, K1Y 4W7, Canada
| | - Erik J. Suuronen
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, K1Y 4W7, Canada
| | - Thien-Fah Mah
- Department of Biochemistry, Microbiology, and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| | - Emilio I. Alarcon
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, K1Y 4W7, Canada
- Department of Biochemistry, Microbiology, and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
14
|
Tani A, Chellini F, Giannelli M, Nosi D, Zecchi-Orlandini S, Sassoli C. Red (635 nm), Near-Infrared (808 nm) and Violet-Blue (405 nm) Photobiomodulation Potentiality on Human Osteoblasts and Mesenchymal Stromal Cells: A Morphological and Molecular In Vitro Study. Int J Mol Sci 2018; 19:ijms19071946. [PMID: 29970828 PMCID: PMC6073131 DOI: 10.3390/ijms19071946] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 06/15/2018] [Accepted: 06/29/2018] [Indexed: 01/08/2023] Open
Abstract
Photobiomodulation (PBM) has been used for bone regenerative purposes in different fields of medicine and dentistry, but contradictory results demand a skeptical look for its potential benefits. This in vitro study compared PBM potentiality by red (635 ± 5 nm) or near-infrared (NIR, 808 ± 10 nm) diode lasers and violet-blue (405 ± 5 nm) light-emitting diode operating in a continuous wave with a 0.4 J/cm2 energy density, on human osteoblast and mesenchymal stromal cell (hMSC) viability, proliferation, adhesion and osteogenic differentiation. PBM treatments did not alter viability (PI/Syto16 and MTS assays). Confocal immunofluorescence and RT-PCR analyses indicated that red PBM (i) on both cell types increased vinculin-rich clusters, osteogenic markers expression (Runx-2, alkaline phosphatase, osteopontin) and mineralized bone-like nodule structure deposition and (ii) on hMSCs induced stress fiber formation and upregulated the expression of proliferation marker Ki67. Interestingly, osteoblast responses to red light were mediated by Akt signaling activation, which seems to positively modulate reactive oxygen species levels. Violet-blue light-irradiated cells behaved essentially as untreated ones and NIR irradiated ones displayed modifications of cytoskeleton assembly, Runx-2 expression and mineralization pattern. Although within the limitations of an in vitro experimentation, this study may suggest PBM with 635 nm laser as potential effective option for promoting/improving bone regeneration.
Collapse
Affiliation(s)
- Alessia Tani
- Department of Experimental and Clinical Medicine-Section of Anatomy and Histology, University of Florence, Largo Brambilla 3, 50134 Florence, Italy.
| | - Flaminia Chellini
- Department of Experimental and Clinical Medicine-Section of Anatomy and Histology, University of Florence, Largo Brambilla 3, 50134 Florence, Italy.
| | - Marco Giannelli
- Odontostomatologic Laser Therapy Center, via dell' Olivuzzo 162, 50143 Florence, Italy.
| | - Daniele Nosi
- Department of Experimental and Clinical Medicine-Section of Anatomy and Histology, University of Florence, Largo Brambilla 3, 50134 Florence, Italy.
| | - Sandra Zecchi-Orlandini
- Department of Experimental and Clinical Medicine-Section of Anatomy and Histology, University of Florence, Largo Brambilla 3, 50134 Florence, Italy.
| | - Chiara Sassoli
- Department of Experimental and Clinical Medicine-Section of Anatomy and Histology, University of Florence, Largo Brambilla 3, 50134 Florence, Italy.
| |
Collapse
|
15
|
Giannelli M, Bani D, Tani A, Materassi F, Chellini F, Sassoli C. Effects of an Erbium:Yttrium-Aluminum-Garnet Laser and Ultrasonic Scaler on Titanium Dioxide-Coated Titanium Surfaces Contaminated With Subgingival Plaque: An In Vitro Study to Assess Post-Treatment Biocompatibility With Osteogenic Cells. J Periodontol 2017; 88:1211-1220. [PMID: 28691887 DOI: 10.1902/jop.2017.170195] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Effects of conventional ultrasonic scaler versus an erbium:yttrium-aluminum-garnet (Er:YAG) laser on titanium surfaces contaminated with subgingival plaque from patients with peri-implantitis are evaluated in terms of: 1) plaque and biocorroded titanium oxide coating removal; 2) surface change induction; and 3) residual biocompatibility toward osteoblasts. METHODS Subgingival plaque-coated titanium disks with a moderately rough surface were fixed with ethanol and treated with an ultrasonic scaler (metal tip) or Er:YAG laser (20.3 or 38.2 J/cm2) in non-contact mode. Fluorescent detection of residual plaque was performed. Disk surface morphology was evaluated by scanning electron microscopy. Viability, attachment, proliferation, and differentiation of Saos-2 osteoblasts on new and treated disks were assayed by propidium iodide/DNA stain assay and confocal microscopic analysis of cytoskeleton, Ki67, expression of osteopontin and alkaline phosphatase, and formation of mineralized nodules. RESULTS Both methods resulted in effective debridement of treated surfaces, the plaque area being reduced to 11.7% with the ultrasonic scaler and ≤0.03% with the Er:YAG laser (38.2 J/cm2). Ultrasound-treated disks showed marked surface changes, incomplete removal of the titanium dioxide (TiO2) layer, and scanty plaque aggregates, whereas the Er:YAG laser (38.2 J/cm2) completely stripped away the plaque and TiO2 layer, leaving a micropitted surface. Both treatments maintained a good biocompatibility of surfaces to Saos-2 osteoblasts. Air-water cooling kept disk temperature below the critical threshold of 47°C. CONCLUSION This study shows that an ultrasonic scaler with metal tip is less efficient than high-energy Er:YAG irradiation to remove the plaque and TiO2 layer on anodized disks, although both procedures appear capable of restoring an adequate osseoconductivity of treated surfaces.
Collapse
Affiliation(s)
| | - Daniele Bani
- Department of Experimental and Clinical Medicine, Section of Anatomy and Histology, University of Florence, Florence, Italy
| | - Alessia Tani
- Department of Experimental and Clinical Medicine, Section of Anatomy and Histology, University of Florence, Florence, Italy
| | | | - Flaminia Chellini
- Department of Experimental and Clinical Medicine, Section of Anatomy and Histology, University of Florence, Florence, Italy
| | - Chiara Sassoli
- Department of Experimental and Clinical Medicine, Section of Anatomy and Histology, University of Florence, Florence, Italy
| |
Collapse
|
16
|
Mesenchymal stromal cell and osteoblast responses to oxidized titanium surfaces pre-treated with λ = 808 nm GaAlAs diode laser or chlorhexidine: in vitro study. Lasers Med Sci 2017; 32:1309-1320. [PMID: 28551763 DOI: 10.1007/s10103-017-2243-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 05/19/2017] [Indexed: 12/15/2022]
Abstract
Preservation of implant biocompatibility following peri-implantitis treatments is a crucial issue in odontostomatological practice, being closely linked to implant re-osseointegration. Our aim was to assess the responses of osteoblast-like Saos2 cells and adult human bone marrow-mesenchymal stromal cells (MSCs) to oxidized titanium surfaces (TiUnite®, TiU) pre-treated with a 808 ± 10 nm GaAlAs diode laser operating in non-contact mode, in continuous (2 W, 400 J/cm2; CW) or pulsed (20 kHz, 7 μs, 0.44 W, 88 J/cm2; PW) wave, previously demonstrated to have a strong bactericidal effect and proposed as optional treatment for peri-implantitis. The biocompatibility of TiU surfaces pre-treated with chlorhexidine digluconate (CHX) was also evaluated. In particular, in order to mimic the in vivo approach, TiU surfaces were pre-treated with CHX (0.2%, 5 min); CHX and rinse; and CHX, rinse and air drying. In some experiments, the cells were cultured on untreated TiU before being exposed to CHX. Cell viability (MTS assay), proliferation (EdU incorporation assay; Ki67 confocal immunofluorescence analysis), adhesion (morphological analysis of actin cytoskeleton organization), and osteogenic differentiation (osteopontin confocal immunofluorescence analysis; mineralized bone-like nodule formation) analyses were performed. CHX resulted cytotoxic in all experimental conditions. Diode laser irradiation preserved TiU surface biocompatibility. Notably, laser treatment appeared even to improve the known osteoconductive properties of TiU surfaces. Within the limitations of an in vitro experimentation, this study contributes to provide additional experimental basis to support the potential use of 808 ± 10 nm GaAlAs diode laser at the indicated irradiation setting, in the treatment of peri-implantitis and to discourage the use of CHX.
Collapse
|
17
|
Effects of photodynamic laser and violet-blue led irradiation on Staphylococcus aureus biofilm and Escherichia coli lipopolysaccharide attached to moderately rough titanium surface: in vitro study. Lasers Med Sci 2017; 32:857-864. [PMID: 28283813 DOI: 10.1007/s10103-017-2185-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Accepted: 03/02/2017] [Indexed: 02/03/2023]
Abstract
Effective decontamination of biofilm and bacterial toxins from the surface of dental implants is a yet unresolved issue. This study investigates the in vitro efficacy of photodynamic treatment (PDT) with methylene blue (MB) photoactivated with λ 635 nm diode laser and of λ 405 nm violet-blue LED phototreatment for the reduction of bacterial biofilm and lipopolysaccharide (LPS) adherent to titanium surface mimicking the bone-implant interface. Staphylococcus aureus biofilm grown on titanium discs with a moderately rough surface was subjected to either PDT (0.1% MB and λ 635 nm diode laser) or λ 405 nm LED phototreatment for 1 and 5 min. Bactericidal effect was evaluated by vital staining and residual colony-forming unit count. Biofilm and titanium surface morphology were analyzed by scanning electron microscopy (SEM). In parallel experiments, discs coated with Escherichia coli LPS were treated as above before seeding with RAW 264.7 macrophages to quantify LPS-driven inflammatory cell activation by measuring the enhanced generation of nitric oxide (NO). Both PDT and LED phototreatment induced a statistically significant (p < 0.05 or higher) reduction of viable bacteria, up to -99 and -98% (5 min), respectively. Moreover, besides bactericidal effect, PDT and LED phototreatment also inhibited LPS bioactivity, assayed as nitrite formation, up to -42%, thereby blunting host inflammatory response. Non-invasive phototherapy emerges as an attractive alternative in the treatment of peri-implantitis to reduce bacteria and LPS adherent to titanium implant surface without causing damage of surface microstructure. Its efficacy in the clinical setting remains to be investigated.
Collapse
|