Carr JC, Pedagandham SP, Giugni A, Shen C, Kim AM, Cribbin EM, Lin X, Oomatia A, Lu W, Al Muderis M, Xing D, Li JJ. Bone mineral density in osseointegration implant surgery: A review of current studies (Review). Biomed Rep 2024; 21:122. [PMID: 38978538 PMCID: PMC11229397 DOI: 10.3892/br.2024.1809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 06/04/2024] [Indexed: 07/10/2024] Open
Abstract
Osseointegration implant (OI) surgery is the latest rehabilitation technology for amputees, where a bone-anchored implant obviates the limitations of traditional socket prostheses. The bone mineral density (BMD) in the periprosthetic and other anatomical regions can be used to assess bone remodelling following OI surgery. Currently, limited studies have used BMD measurements in reporting post-operative OI outcomes and the association between the maintenance of BMD and implant efficacy has remained elusive. This review captured and analysed all studies that have reported the BMD as an objective outcome measure in patients with trans-femoral or trans-tibial OI. The PubMed, Medline, Scopus and Web of Science databases were searched using the terms 'amputation', 'osseointegration' and 'bone mineral density'. A total of 6 studies involving human participants were included for analysis. All studies used dual X-ray absorptiometry and/or X-rays for measuring BMD. Rehabilitation of trans-femoral or trans-tibial amputation using OI may help restore healthy BMD by enabling physiological bone loading. However, there is a low correlation between the BMD around the OI and the success of OI surgery or the risk of periprosthetic fractures. This review summarises the current evidence on BMD assessment in OI for lower limb amputee rehabilitation. Despite the great variability in the results, the available evidence suggests that OI may help restore BMD following surgery. The limited evidence calls for further investigation, as well as the development of a standard BMD measurement protocol.
Collapse
Affiliation(s)
- Joshua C Carr
- Kolling Institute, Faculty of Medicine and Health, University of Sydney, St Leonards, NSW 2065, Australia
| | - Sai Pranitha Pedagandham
- School of Biomedical Engineering, Faculty of Engineering and IT, University of Technology Sydney, Ultimo, NSW 2007, Australia
- Osseointegration Group of Australia, Sydney, NSW 2153, Australia
| | - Amelia Giugni
- School of Biomedical Engineering, Faculty of Engineering and IT, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Christina Shen
- Osseointegration Group of Australia, Sydney, NSW 2153, Australia
| | - Alice M Kim
- School of Biomedical Engineering, Faculty of Engineering and IT, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Elise M Cribbin
- School of Biomedical Engineering, Faculty of Engineering and IT, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Xiaoqi Lin
- School of Biomedical Engineering, Faculty of Engineering and IT, University of Technology Sydney, Ultimo, NSW 2007, Australia
| | - Atiya Oomatia
- Osseointegration Group of Australia, Sydney, NSW 2153, Australia
| | - William Lu
- Osseointegration Group of Australia, Sydney, NSW 2153, Australia
| | | | - Dan Xing
- Arthritis Clinic and Research Center, Peking University People's Hospital, Peking University, Beijing 100044, P.R. China
| | - Jiao Jiao Li
- Kolling Institute, Faculty of Medicine and Health, University of Sydney, St Leonards, NSW 2065, Australia
- School of Biomedical Engineering, Faculty of Engineering and IT, University of Technology Sydney, Ultimo, NSW 2007, Australia
| |
Collapse
|
2
|
Ramesh A, Di Laura A, De Angelis S, Henckel J, Hart A. Bone remodeling after revision total hip arthroplasty for large acetabular defects. J Orthop Res 2024. [PMID: 38992884 DOI: 10.1002/jor.25936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 05/14/2024] [Accepted: 06/11/2024] [Indexed: 07/13/2024]
Abstract
Large acetabular bone defects are challenging in hip revision surgery. Clinical assessment is crucial to evaluate modern technologies in surgical reconstruction. We aimed to better understand the bone remodeling that occurs following acetabular reconstruction. Our objectives were: (1) To characterize changes in the shape of the pelvis by studying sequential computed tomography (CT) scans collected immediately and 1-year postoperatively and (2) to identify which part of the pelvis is most susceptible to remodeling. We used the CT scans taken at two timepoints, of 24 patients with acetabular bone defects classified as Paprosky IIIB, treated with three-dimensional (3D)-printed custom-made acetabular implants. Segmented 3D models of the bony pelvis were co-registered using three different techniques. A global co-registration of the full pelvis was conducted, followed by the co-registration of the innominate bone and then ilium only, on the ipsilateral reconstructed side. The relative movements of the ilium, ischium, and pubis were analyzed from visual inspection and using co-registration metrics (root mean square error and intersection over union). No bone remodeling was found in 14/24 patients (58%). The co-registration of the innominate bone indicated bone remodeling in five cases (21%), while the remaining five cases (21%) presented remodeling in the global co-registration but not the innominate bone co-registration, suggestive of changes occurring at the sacroiliac joint. Changes in the pelvic shape were greatest at the pubis and ischium. Bone remodeling may occur in complex cases of Paprosky type IIIB defects, after acetabular reconstruction (occurrence of 21%, 5/24 cases). Surgeons and engineers should consider this when monitoring implant migration.
Collapse
Affiliation(s)
- Angelika Ramesh
- Department of Mechanical Engineering, University College London, London, UK
| | - Anna Di Laura
- Department of Mechanical Engineering, University College London, London, UK
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Sara De Angelis
- Department of Mechanical Engineering, University College London, London, UK
| | - Johann Henckel
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Alister Hart
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
- Institute of Orthopaedics and Musculoskeletal Science, University College London, London, UK
- Cleveland Clinic London, London, UK
| |
Collapse
|
3
|
Christiansen JD, Laursen M, Blunn GW, Nielsen PT. Stable fixation of an ultra-short femoral neck-preserving hip prosthesis: a 5-year RSA, DXA, and clinical prospective outcome study of 48 patients. Acta Orthop 2024; 95:138-146. [PMID: 38392247 PMCID: PMC10886218 DOI: 10.2340/17453674.2024.40074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 01/09/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND AND PURPOSE We previously showed promising primary stability and preservation of bone stock with the ultra-short neck-loading hip implant in total hip arthroplasty (THA). The aim of this study was to evaluate clinical outcome, implant stability, and bone mineral density (BMD). METHODS 50 patients were treated with the ultra-short neck Primoris hip implant at baseline and 48 were available for evaluation at 5-year follow-up. 5 different patient-reported outcome measures (PROMs) including hip-specific scores, disease-specific and generic quality of life outcome measures, and an activity score were used. Furthermore, implant stability using radiostereometric analysis (RSA) and assessment of periprosthetic BMD using dual-energy X-ray absorptiometry (DXA) were applied. RESULTS By 1-year follow-up, all PROMs showed improvements and remained high at 5-year follow-up. After initial distal translation (subsidence) and negative rotation around the z-axis (varus tilt) the implant showed stable fixation at 5-year follow-up with no further migration beyond 12 months. In the regions of interest (ROI) 3 and 4, BMD remained stable. In ROI 2, further bone loss of 12% was found at 5-year follow-up. CONCLUSION Clinical outcome including PROMs was satisfying throughout the 5-year follow-up period. The hip implant remains stable with both bone preservation and loss 5 years after surgery.
Collapse
Affiliation(s)
- Janus D Christiansen
- Department of Orthopaedic Surgery and Orthopaedic Surgery Research Unit, Aalborg University, Aalborg, North Region; Department of Clinical Medicine, Aalborg University, Aalborg, North Region, Denmark.
| | - Mogens Laursen
- Department of Orthopaedic Surgery and Orthopaedic Surgery Research Unit, Aalborg University, Aalborg, North Region; Department of Clinical Medicine, Aalborg University, Aalborg, North Region, Denmark
| | - Gordon W Blunn
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK
| | - Poul T Nielsen
- Department of Orthopaedic Surgery and Orthopaedic Surgery Research Unit, Aalborg University, Aalborg, North Region
| |
Collapse
|
4
|
Mittelstaedt H, Anderl C, Ortmaier R, Johl C, Krüger T, Wallroth K, Weigert U, Schagemann JC. Subsidence analysis of a cementless short stem THA using EBRA-FCA - A seven-year prospective multicentre study. J Orthop 2023; 43:93-100. [PMID: 37575949 PMCID: PMC10415660 DOI: 10.1016/j.jor.2023.06.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 06/26/2023] [Indexed: 08/15/2023] Open
Abstract
Background Metaphyseal fixation of short stem THA allows for minimally invasive surgery, less bone removal, improved bone load transfer and reduced stress shielding. Short stems facilitate the anatomic restoration i.a. of leg length, femoroacetabular offset, and center of rotation. However, metaphyseal fixation might cause impaired primary and/or secondary stability resulting in an inherent tendency for early axial migration and aseptic loosening eventually. The objective of this study was to investigate the long-term outcome and migration pattern of a calcar-guided short stem. Methods In a prospective multicenter study, 213 patients (224 THAs) were enrolled. Patients were followed for up to 84 months postoperatively. Clinical outcome was assessed using the Harris Hip Score and the VAS for pain and satisfaction. Standardized and calibrated radiographs were screened i.a. for stress shielding and loosening. Einzel-Bild-Roentgen-Analyse - femoral component analysis (EBRA-FCA) was used to detect longitudinal subsidence. Results At 7 year follow-up, n = 139/224 cases were available for analysis. All clinical parameters improved significantly (p < 0.001) and improvement persisted. There were no radiographic changes indicating stress shielding. EBRA-FCA revealed a mean subsidence of -1.44 mm followed by a stabilization. Weight >80 kg (p = 0.115), BMI <30 kg/m2 (p = 0.282), male gender (p = 0.246), and age <65 years (p = 0.304) seemed to be associated with a higher risk for migration. The cumulative revision rate was 2.23%. Revisions due to stem migration (0.89%) occurred early (mean time between index surgery and revision: 3.3 months). Conclusions If at all, there appears to be a pronounced initial subsidence, which stabilizes thereafter. Stem migration was rarely a compelling reason for failure or revision. Demographics do not seem to have a significant effect on migration pattern. The absence of radioluce lines, resorption or hypertrophy of the proximal femora support the hypothesis of a reduced stress shielding for metaphyseal anchoring short stems.
Collapse
Affiliation(s)
- Hagen Mittelstaedt
- UKSH Campus Lübeck, Klinik für Orthopädie und Unfallchirurgie Sektion Orthopädie, Ratzeburger Allee, Lübeck, Germany
| | - Conrad Anderl
- Ordensklinikum Linz, Krankenhaus der Barmherzigen Schwestern Linz GmbH, Seilerstätte, Linz, Austria
| | - Reinhold Ortmaier
- Ordensklinikum Linz, Krankenhaus der Barmherzigen Schwestern Linz GmbH, Seilerstätte, Linz, Austria
| | - Carsten Johl
- Klinikum Dahme-Spreewald GmbH, Lübben (Spreewald), Germany
| | - Thomas Krüger
- Helios Klinik Köthen, Hallesche Straße, Köthen (Anhalt), Germany
| | - Karsten Wallroth
- Kreiskrankenhaus Stollberg GmbH, Jahnsdorfer Straße Stollberg, Stollberg, Germany
| | - Ulrich Weigert
- Praxis für Orthopädie und Unfallchirurgie, Friedrichstraße, Erkner, Germany
| | - Jan C. Schagemann
- UKSH Campus Lübeck, Klinik für Orthopädie und Unfallchirurgie Sektion Orthopädie, Ratzeburger Allee, Lübeck, Germany
- Christophorus Kliniken Coesfeld, Südring 41, 48653, Coesfeld, Germany
| |
Collapse
|
5
|
Anjiki K, Hayashi S, Fujishiro T, Hiranaka T, Kuroda R, Matsumoto T. Rectangular tapered short stem excellently preserves proximal bone mineral density preservation than tapered wedge short stem. Acta Orthop Belg 2023; 89:491-497. [PMID: 37935234 DOI: 10.52628/89.3.11833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Fitmore stem is a rectangular, tapered, short, cementless stem. A characteristic feature of this stem is that it provides rotational stability due to the high medullary occupancy achieved by its rectangular cross-section and thick antero- posterior width. We aimed to investigate the differences in periprosthetic bone remodelling between a rectangular- tapered short stem and a short tapered-wedge stem. Eighty patients who underwent primary total hip arthroplasty using a rectangular-tapered short stem (Fitmore) or a short tapered-wedge stem (Tri-Lock BPS) were enrolled in this study. Bone mineral densities (BMDs) in the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry at baseline, and at 6 and 24 months postoperatively. Peri-prosthetic BMD and clinical factors were assessed and compared. In addition, correlations between periprosthetic BMD changes and stem anteversion error were analyzed using Pearson's correlation coefficient in the two groups. A significantly better postoperative periprosthetic BMD change was found in zones 1 and 7 in the rectangular-tapered group. Additionally, no significant correlation was observed between stem anteversion error and periprosthetic BMD changes in the rectangular-tapered groups. However, in the tapered-wedge group, there were significant negative correlations between the stem anteversion error and BMD changes at 6 months and 24 months in zones 1 and 7. In the rectangular-tapered group, a significantly better postoperative periprosthetic BMD change was found particularly in the region proximal to the stem. Rectangular-tapered short stem can be more resistant to rotation due to higher medullary occupancy and may lead to better periprosthetic BMD than the tapered-wedge short stem, especially in the proximal region of the stem.
Collapse
|
6
|
Ding Z, Wang J, Wang Y, Zhang X, Huan Y, Zhang D. Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis. BMC Musculoskelet Disord 2023; 24:89. [PMID: 36732725 PMCID: PMC9893650 DOI: 10.1186/s12891-023-06205-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 01/30/2023] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Short-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint. METHODS Native femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress/strain cloud chart allowed the direction of stress/strain to be assessed. Six BCFP models with different screw angles (5°, 10°, 15°, 20°, 25°, and 30°) and the Corail model were created. The stress/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models. RESULTS The native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5° stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur. CONCLUSIONS Stress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5° stem minimizes the stress shielding effect and presents a more bionic mechanical performance.
Collapse
Affiliation(s)
- Zhentao Ding
- grid.411634.50000 0004 0632 4559Department of Orthopedics and Trauma, Peking University People’s Hospital, Beijing, 100044 China ,grid.411634.50000 0004 0632 4559National Centre for Trauma Medicine, Peking University People’s Hospital, Beijing, 100044 China ,grid.419897.a0000 0004 0369 313XKey Laboratory of Trauma and Neural Regeneration (Peking University), Ministry of Education, Beijing, 100044 China
| | - Jun Wang
- grid.9227.e0000000119573309State Key Laboratory of Nonlinear Mechanics (LNM), Institute of Mechanics, Chinese Academy of Sciences, Beijing, 100190 China ,grid.410726.60000 0004 1797 8419School of Engineering Science, University of Chinese Academy of Sciences, Beijing, 100049 China
| | - Yanhua Wang
- grid.411634.50000 0004 0632 4559Department of Orthopedics and Trauma, Peking University People’s Hospital, Beijing, 100044 China ,grid.411634.50000 0004 0632 4559National Centre for Trauma Medicine, Peking University People’s Hospital, Beijing, 100044 China ,grid.419897.a0000 0004 0369 313XKey Laboratory of Trauma and Neural Regeneration (Peking University), Ministry of Education, Beijing, 100044 China
| | - Xiaomeng Zhang
- grid.411634.50000 0004 0632 4559Department of Orthopedics and Trauma, Peking University People’s Hospital, Beijing, 100044 China ,grid.411634.50000 0004 0632 4559National Centre for Trauma Medicine, Peking University People’s Hospital, Beijing, 100044 China ,grid.419897.a0000 0004 0369 313XKey Laboratory of Trauma and Neural Regeneration (Peking University), Ministry of Education, Beijing, 100044 China
| | - Yong Huan
- grid.9227.e0000000119573309State Key Laboratory of Nonlinear Mechanics (LNM), Institute of Mechanics, Chinese Academy of Sciences, Beijing, 100190 China ,grid.410726.60000 0004 1797 8419School of Engineering Science, University of Chinese Academy of Sciences, Beijing, 100049 China
| | - Dianying Zhang
- grid.411634.50000 0004 0632 4559Department of Orthopedics and Trauma, Peking University People’s Hospital, Beijing, 100044 China ,grid.411634.50000 0004 0632 4559National Centre for Trauma Medicine, Peking University People’s Hospital, Beijing, 100044 China ,grid.419897.a0000 0004 0369 313XKey Laboratory of Trauma and Neural Regeneration (Peking University), Ministry of Education, Beijing, 100044 China
| |
Collapse
|
7
|
Reinbacher P, Smolle MA, Friesenbichler J, Draschl A, Leithner A, Maurer-Ertl W. Three-year migration analysis of a new metaphyseal anchoring short femoral stem in THA using EBRA-FCA. Sci Rep 2022; 12:17173. [PMID: 36229640 PMCID: PMC9561653 DOI: 10.1038/s41598-022-22160-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 10/10/2022] [Indexed: 01/04/2023] Open
Abstract
Cementless calcar-guided femoral short stems in total hip arthroplasty (THA) have become increasingly popular over the years. Early distal migration of femoral stems measured by Einzel-Bild-Roentgen Analyse, Femoral Component Analyse (EBRA-FCA) has been reported to be a risk factor for aseptic loosening. The aim of this study was to analyse axial migration behavior and subsidence of a new short stem (launched in 2015) over a follow-up period of 3 years. According to the study protocol, 100 hip osteoarthritis patients who consecutively received an unilateral cementless calcar-guided short stem (ANA.NOVA proxy) at a single department were prospectively included in this mid-term follow-up study. Thirteen patients were lost to follow-up, resulting in 87 patients with unilateral THA who fulfilled the criteria for migration analysis with EBRA-FCA. The cohort comprised 41 males (mean age: 60 ± 16.5; mean BMI (Body Mass Index): 30 ± 13) and 46 females (mean age: 61 ± 15.5; mean BMI: 27 ± 10). Seven standardized radiographs per patient were analyzed with EBRA-FCA. An average migration of 2.0 mm (0.95-3.35) was observed within the first 3 years. The median increase during the first year was higher than in the second and third year (1.2 mm [IQR: 0.5-2.15] vs. 0.3 mm [IQR: 0.1-0.6 mm] vs. 0.25 mm [IQR: 0.1-0.5 mm]. Detected migration did not lead to stem loosening, instability, dislocation, or revision surgery in any patient. A higher risk for subsidence was observed in male and heavyweight patients, whereas the female gender was associated with a lower risk. No correlation between migration and revision could be observed. Although moderate subsidence was detectable, the performance of the short stem ANA.NOVA proxy is encouraging. Yet, its use may be re-considered in overweight and male patients due to more pronounced subsidence.
Collapse
Affiliation(s)
- Patrick Reinbacher
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Maria Anna Smolle
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
| | - Joerg Friesenbichler
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Alexander Draschl
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Werner Maurer-Ertl
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| |
Collapse
|
8
|
Anil U, Singh V, Schwarzkopf R. Diagnosis and Detection of Subtle Aseptic Loosening in Total Hip Arthroplasty. J Arthroplasty 2022; 37:1494-1500. [PMID: 35189292 DOI: 10.1016/j.arth.2022.02.060] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/10/2022] [Accepted: 02/14/2022] [Indexed: 02/02/2023] Open
Abstract
Aseptic loosening is a common cause of revision total hip arthroplasty (rTHA), and with the rising number of primary THAs, revisions for aseptic loosening represent a significant burden for arthroplasty surgeons. Aseptic loosening remains a diagnostic and management challenge. Loosening can occur as a result of inadequate initial fixation, mechanical loss of fixation over time, or a biological loss of fixation over time. However, in most cases, etiology is multifactorial, involving all 3 factors. The diagnosis of aseptic loosening involves a careful history, focused clinical exam, and thorough evaluation of imaging using several diagnostic modalities. The careful evaluation of serial radiographs remains the cornerstone of diagnosis with additional input from advanced imaging modalities such as FDG-PET, DEXA, MRI, and several others, each offering unique advantages and disadvantages. In certain patients, history and physical exam might be the only initial obvious signs of loosening, and thus, unexplained continuous pain augmented by imaging findings serves as an indication for revision surgery.
Collapse
Affiliation(s)
- Utkarsh Anil
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| | - Vivek Singh
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York
| |
Collapse
|
9
|
Anderl C, Steinmair M, Hochreiter J. Bone Preservation in Total Hip Arthroplasty. J Arthroplasty 2022; 37:1118-1123. [PMID: 35121089 DOI: 10.1016/j.arth.2022.01.077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 12/27/2021] [Accepted: 01/22/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Preserving bone stock in younger and more active patients after total hip arthroplasty (THA) is important for future revision. Newer prosthesis designs, including short femoral stems and isoelastic acetabular cups, are likely to preserve more bone stock. However, long-term follow-up studies on bone remodeling after short-stem THA with an isoelastic monoblock acetabular cup are few. Therefore, we evaluated bone preservation after THA using these prostheses at a 5-year follow-up. METHODS This prospective observational study is a 5-year follow-up of our previously reported 2-year observational study on the same cohort of patients. We included 45 patients with primary osteoarthritis treated with a calcar-guided femoral short-stem prosthesis and a monoblock press-fit acetabular cup. We evaluated bone mineral density (BMD) around the prostheses using dual-energy X-ray absorptiometry and reported functional outcomes preoperatively and at 3, 12, 24, and 60 months postoperatively. All complications were recorded. RESULTS At the final follow-up, the BMD was comparable with that at 24 months in Gruen zones 3, 4, 5, 6, and 7, whereas it significantly differed in Gruen zones 1 (P < .0001) and 2 (P < .004). On the acetabular side, the BMD leveled off similarly in all DeLee and Charnley zones between 24 and 60 months (P > .05). Moreover, all measured clinical outcomes significantly improved (P < .001). One perioperative dislocation was reported. CONCLUSION Patients undergoing THA with a calcar-guided femoral short-stem prosthesis and a monoblock acetabular cup can expect preservation of bone stock over a longer follow-up with excellent clinical outcomes and few complications.
Collapse
Affiliation(s)
- Conrad Anderl
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, Austria
| | - Martin Steinmair
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, Austria
| | - Josef Hochreiter
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, Austria
| |
Collapse
|
10
|
[Translated article] Results of the short neck-retaining stem prostheses CFP with a minimum follow-up of 10 years. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022. [DOI: 10.1016/j.recot.2021.09.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
11
|
Berlanga-de-Mingo D, Pons-Cabrafiga M. Resultado del vástago corto con preservación del cuello femoral CFP con un seguimiento mínimo de 10 años. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022; 66:176-181. [DOI: 10.1016/j.recot.2021.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 06/29/2021] [Accepted: 09/07/2021] [Indexed: 10/19/2022] Open
|
12
|
Liu Y, Wei WX, Zeng Y, Ma J, Yang J, Shen B. Comparison of Femoral Bone Mineral Density Changes around 3 Common Designs of Cementless Stems after Total Hip Arthroplasty-A Retrospective Cohort Study. Orthop Surg 2022; 14:1059-1070. [PMID: 35466536 PMCID: PMC9163965 DOI: 10.1111/os.13265] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 03/16/2022] [Accepted: 03/21/2022] [Indexed: 02/04/2023] Open
Abstract
Objective The aim of this study was to compare the periprosthetic BMD changes around Tri‐Lock “Bone Preserving Stem” with the other two common and longer stems (Corail and Summit) after THA. Methods It was a retrospective cohort study followed patients underwent the total hip arthroplasty from January 2013 to December 2015. They were selected and followed from January 2013 to Janaury 2020. Patients without osteoporosis underwent hip replacements with three aimed stems were included. Among the 138 patients included, 49 patients received the Tri‐Lock stem, 44 patients received the Corail stem, and 45 patients received the Summit stem. The periprosthetic BMD changes evaluated by the Dual energy X‐ray absorptiometry (iDXA) measurement according to the seven Gruen zones was the primary outcome. The Radiographic changes including spot welds, pedestal sign and grade of stress shielding was evaluated by the consecutive hip images. Einzel‐Bild‐Roentgen‐Analyze‐femoral component analysis (EBRA‐FCA) was used to measure the stem migration at 5 years postoperatively. Patient‐reported outcomes (PROMs) and adverse events were assessed and compared in three groups. Finally, the subgroups for the periprosthetic BMD changes, radiological and clinical outcomes were made based on the age, gender and length of follow‐up. Results A total of 138 patients were retrospectively followed for an average of 4.66 years. Excepting the different stems used in three groups, the age, gender and other characteristics of patients included were similar between groups. There was no significant difference between the three groups in periprosthetic BMD changes over postoperative 5 years. The Summit stem shown more BMD loss in Gruen zone 1 compared with the Tri‐Lock and Corail stems without significant difference (7.49%, −1.89% and −2.62%, respectively, P = 0.42). And the most prominent BMD loss was found in Gruen zone 7 for all three stems (−12.60%, −11.84%, and −9.56%, respectively, P = 0.91). The spot weld was significantly more common around the Corail stem, while there was no difference in the stem migration between three groups. Patient reported outcomes (PROMs) were significantly improved compared with the preoperative values. Regarding the rate of postoperative complications, two patients underwent the dislocation and 25 patients sometimes felt mild to moderate thigh pain. Subgroup analysis showed that female patients older than 50 years lost more BMD and had lower clinical scores, while the stem stability was not good enough in male patients. Conclusions The Tri‐Lock Bone Preserving Stem did not show significant difference in periprosthetic BMD changes compared with the other two conventional longer stems at 5 years after THA.
Collapse
Affiliation(s)
- Yuan Liu
- Orthopedics Research Institute, Department of Orthopedics, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Wen-Xing Wei
- Orthopedics Research Institute, Department of Orthopedics, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yi Zeng
- Orthopedics Research Institute, Department of Orthopedics, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jun Ma
- Orthopedics Research Institute, Department of Orthopedics, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jing Yang
- Orthopedics Research Institute, Department of Orthopedics, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Bin Shen
- Orthopedics Research Institute, Department of Orthopedics, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
13
|
Djebara AE, El Yagoubi A, Mertl P, El Fatayri B, Dehl M, Gabrion A. Comparison of periprosthetic bone mineral density between two types of short-stems in total hip arthroplasty with a mean follow-up of 4 years. Orthop Traumatol Surg Res 2022; 108:103044. [PMID: 34389498 DOI: 10.1016/j.otsr.2021.103044] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 12/17/2020] [Accepted: 01/04/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The use of short stems in primary hip arthroplasty has grown considerably in recent years, with a large variety of designs and stabilization methods available. Few studies have directly compared how these designs and fixation modes influence the bone mineral density (BMD) that is said to be better preserved with shorter implants. This led us to carry out a medium-term retrospective comparative study to (1) specify how the design of two different types of short stems influences the periprosthetic BMD, (2) compare the radiological and clinical outcomes of these stems. HYPOTHESIS The periprosthetic BMD of a short stem varies based on the implant's design. MATERIALS AND METHODS Ninety-three patients underwent total hip arthroplasty (THA) with a short stem between July 2012 and July 2014. Two groups of patients were formed: Vitae™ short stem (Adler Ortho, Milan, France), Optimys™ short stem (Mathys, Bettlach, Switzerland). The Vitae group consisted of 46 patients, while the Optimys group consisted of 47 patients. The mean age was 66 years, and the mean body mass index (BMI) was 26 kg/m2. The groups had comparable age, BMI, sex, Harris Hip score and preoperative radiological features. Periprosthetic BMD of the two types of implants was determined between the 1st and 4th year postoperative using dual-energy x-ray absorptiometry (DEXA) in the Gruen zones. The radiological and clinical outcomes were also determined. RESULTS There was a significant decrease in BMD in zone 7(-5.8%±0.1 CI95%[-0.09; -0.02] (p=0.003)), zone 2 (-4.8% ±0.1 CI95%[-0.093; -0.003] (p=0.038)) and zone 6 (-11% ±0.2 CI95%[-0.19; -0.03] (p=0.009)) in the patients with Vitae stems and in zone 2 (-13.7%±0.3 CI95%[-0.25; -0.03] (p=0.018)) in the patients with Optimys stems. A significant difference in BMD in zone 7 at 1 year (p=0.014) and 4 years (p=0.001) postoperative and in zone 6 (p=0.011) at 4 years postoperative existed between groups, with the Optimys group having higher BMD. There was a significant increase in femoral offset in the Optimys group but not the Vitae group: Δoffset=-0.50 mm±5.2 CI95%[-2.05; 1.05] (p=0.522) and Δoffset=2.79 mm±4.2 CI95%[1.21; 4.37] (p=0.001). The Harris Hip score was not significantly different between the two groups at 4 years postoperative (95.3±2.5 [88; 99] vs. 95.2±2.6 [88; 99] (p=0.991)). DISCUSSION The design of short stems appears to influence the distribution of loads and the periprosthetic BMD. These stems are associated with very good radiological and clinical results in the medium term. Bone remodeling appears to continue beyond 1 year after the THA procedure. LEVEL OF EVIDENCE III; Retrospective case-control study.
Collapse
Affiliation(s)
- Az-Eddine Djebara
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France.
| | - Abdelkader El Yagoubi
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Patrice Mertl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Bachar El Fatayri
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Massinissa Dehl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Antoine Gabrion
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| |
Collapse
|
14
|
Afghanyar Y, Kutzner KP, Pfeil J, Drees P, Rehbein P, Dargel J. Cementless Short Stems in Total Hip Arthroplasty: Chances and Limits. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2022. [PMID: 35104904 DOI: 10.1055/a-1678-7684] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
In recent decades, a large number of cementless short stems have been introduced to the market. The concept aims at saving soft tissue using minimally invasive surgery and at the same time preserving as much bone as possible. In particular, the latest generation of short stems, which are implanted using a calcar-guided round-the-corner technique, are attracting increasing attention. An individualised resection level allows individual stem alignment and thus an ideal reconstruction of the hip anatomy. The early clinical results of short-stem total hip arthroplasty (THA) are promising and have led to an expansion of the indications and limitations for the use of short stems. In particular, the individual positioning in valgus or varus and the resulting individual metaphyseal or metadiaphyseal anchorage offers various possibilities to reconstruct even abnormal joint morphologies. Consequently, short stems are increasingly used in patients with complex anatomical variations or in cases of osteonecrosis of the femoral head. In some various cases, they can also be used in revision or conversion arthroplasty. In some patients, short stems can also be used after femoral neck fracture. Currently, scientific data on those areas of indication of short-stem THA is scarce.
Collapse
Affiliation(s)
- Yama Afghanyar
- Klinik für Orthopädie und Unfallchirurgie, St Josefs Hospital Wiesbaden GmbH, Wiesbaden, Deutschland
| | - Karl Philipp Kutzner
- Klinik für Orthopädie und Unfallchirurgie, St Josefs Hospital Wiesbaden GmbH, Wiesbaden, Deutschland.,Zentrum für Orthopädie und Unfallchirurgie (ZOU), Universitätsmedizin der Johannes Gutenberg-Universität Mainz, Mainz, Deutschland
| | - Joachim Pfeil
- Klinik für Orthopädie und Unfallchirurgie, St Josefs Hospital Wiesbaden GmbH, Wiesbaden, Deutschland
| | - Philipp Drees
- Zentrum für Orthopädie und Unfallchirurgie (ZOU), Universitätsmedizin der Johannes Gutenberg-Universität Mainz, Mainz, Deutschland
| | - Philipp Rehbein
- Klinik für Orthopädie und Unfallchirurgie, St Josefs Hospital Wiesbaden GmbH, Wiesbaden, Deutschland
| | - Jens Dargel
- Klinik für Orthopädie und Unfallchirurgie, St Josefs Hospital Wiesbaden GmbH, Wiesbaden, Deutschland
| |
Collapse
|
15
|
de Waard S, van der Vis J, Venema PAHT, Sierevelt IN, Kerkhoffs GMMJ, Haverkamp D. Short-term success of proximal bone stock preservation in short hip stems: a systematic review of the literature. EFORT Open Rev 2021; 6:1040-1051. [PMID: 34909223 PMCID: PMC8631238 DOI: 10.1302/2058-5241.6.210030] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Total hip arthroplasty is performed more frequently in younger patients nowadays, making long-term bone stock preservation an important topic. A mechanism for late implant failure is periprosthetic bone loss, caused by stress shielding around the hip stem due to different load distribution. Short stems are designed to keep the physical loading in the proximal part of the femur to reduce stress shielding. The aim of this review is to give more insight into how short and anatomic stems behave and whether they succeed in preservation of proximal bone stock. A systematic literature search was performed to find all published studies on bone mineral density in short and anatomic hip stems. Results on periprosthetic femoral bone mineral density, measured with dual-energy X-ray absorptiometry (DEXA), were compiled and analysed per Gruen zone in percentual change. A total of 29 studies were included. In short stems, Gruen 1 showed bone loss of 5% after one year (n = 855) and 5% after two years (n = 266). Gruen 7 showed bone loss of 10% after one year and –11% after two years. In anatomic stems, Gruen 1 showed bone loss of 8% after one year (n = 731) and 11% after two years (n = 227). Gruen 7 showed bone loss of 14% after one year and 15% after two years. Short stems are capable of preserving proximal bone stock and have slightly less proximal bone loss in the first years, compared to anatomic stems.
Cite this article: EFORT Open Rev 2021;6:1040-1051. DOI: 10.1302/2058-5241.6.210030
Collapse
Affiliation(s)
- Sheryl de Waard
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands.,Academic Medical Centre (AMC), Amsterdam, Netherlands
| | - Jacqueline van der Vis
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Pascale A H T Venema
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Inger N Sierevelt
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | | | - Daniël Haverkamp
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| |
Collapse
|
16
|
Drobniewski M, Synder M, Synder MA, Krasińska M, Olewnik L, Borowski A. Future of total hip arthroplasty with the Metha short stem in modern surgeries. Sci Rep 2021; 11:21763. [PMID: 34741121 PMCID: PMC8571394 DOI: 10.1038/s41598-021-01367-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 10/25/2021] [Indexed: 12/02/2022] Open
Abstract
The aim of the study was to analyse the results of uncemented total hip replacement, using the Metha (metaphyseal) stem. A total of 158 patients (70 females and 88 males) were qualified to the study and submitted to total hip arthroplasty (183 procedures altogether), using the Metha stem. The mean age of the patients on the day of surgery was 51.7 years (the range from 17 to 69 years). The mean follow up period was 9.2 years (the range from 5 to 13.5 years). Preoperative assessments gave poor scores, according to the Merle d’Aubigne and Postel classification, modified by Charnley. The average improvement after surgery, according to the used scale, was 6.9 points. A very good outcome was recorded in 154 cases (84.2%), a good outcome was achieved in 20 cases (10.9%) and a poor outcome was confirmed in 9 cases, while no satisfactory case was observed. Poor outcomes were associated with implant loosening. Extraskeletal ossification was noted in 10 cases (5.5%). According to the Kaplan–Meier estimator, the 10-year survival was 93.2% and 97.3% for the whole implant and the stem alone, respectively. 1. Our follow-up period of more than 9 years on the average, indicates that Metha stems produce excellent clinical and functional results in operated young patients with advanced degenerative changes of the hip joint. 2. Assuming a proper qualification for the procedure, the absence of complications and a correct surgical technique, which is slightly more difficult, when compared to standard stem implantation, the risk of aseptic loosening is fairly negligible.
Collapse
Affiliation(s)
- Marek Drobniewski
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Marek Synder
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Marek Aleksander Synder
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Magdalena Krasińska
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Lukasz Olewnik
- Department of Anatomical Dissection and Donation, Medical University of Lodz, Lodz, Poland
| | - Andrzej Borowski
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland.
| |
Collapse
|
17
|
Pons-Cabrafiga M, Arias de la Torre J, Berlanga-de-Mingo D, Lobo-Escolar L. Is diaphyseal fixation of short neck-retaining stem prostheses related to the size of the implant? Hip Int 2021; 31:196-200. [PMID: 32538203 DOI: 10.1177/1120700020932937] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Short-stem hip prostheses present variable proximal femoral bone radiological findings. The aims of this study were to analyse, in our patients with implanted collum femoris-preserving (CFP) stems, cancellous bone remodelling, cortical distal hypertrophy and pedestal formation, and the relationship between those radiological changes that suggest distal fixation with the size of the stem. METHODS From October 2001 to December 2012 a total of 199 consecutive primary total hip arthroplasties in 180 patients were performed at our department using the CFP stem and followed up for a minimum of 5 years until December 2017. RESULTS Stress shielding was present in 74% of oversized stems cases, but in normal or undersized stems, stress shielding was present in 8.5%. Cortical hyperthrophy was observed in 49% of the oversized stems and in 6% of the normal or undersized ones. Finally, non-statistically significant differences (p = 0.089) in pedestal formation were found, present in 16.3% of the oversized stems and in 6% of normal or undersized ones. CONCLUSIONS Oversized stems cause more stress shielding and distal cortical hypertrophy in the distal part of the stem, which indicates distal fixation in bigger sizes of stem.
Collapse
|
18
|
Hasler J, Flury A, Dimitriou D, Holweg I, Helmy N, Finsterwald M. Mid-term subsidence and periprosthetic radiolucency of the AMIStem: a 5-year EBRA-FCA analysis. J Orthop Surg Res 2021; 16:19. [PMID: 33413463 PMCID: PMC7792117 DOI: 10.1186/s13018-020-02104-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 11/19/2020] [Indexed: 01/22/2023] Open
Abstract
Background There has been an evolution in cementless total hip arthroplasty (THA) with newer short stem designs aimed to preserve metaphyseal bone stock and facilitate implantation through minimally invasive approaches. While early subsidence has been correlated to aseptic loosening in conventional stems, there is a paucity of data regarding short stems. The current study aims to report on stem subsidence and mid-term clinical outcomes of a cementless, metaphyseal-anchored short femoral stem, specifically designed for the direct anterior approach (DAA). Methods Ninety-four consecutive patients (100 hips) with a minimum follow-up of 5 years following cementless THA were included in this single-center retrospective study. Subsidence was evaluated using the “Ein-Bild-Roentgen-Analyse” (EBRA). Periprosthetic radiolucency allocated to the zones of Charnley and Gruen was assessed. Additionally, demographic and implant-related factors potentially associated with increased subsidence and clinical outcomes were evaluated. Results At the last follow-up, the average stem subsidence was 1.98 ± 1.20 mm, with 48% of the implants demonstrating subsidence of > 2 mm. Periprosthetic radiolucency of > 2 mm was found in 26% of the implants in zone 1 and in 9% in zone 7, respectively. Neither the amount of subsidence nor proximal periprosthetic radiolucency was associated with aseptic loosening or worse clinical outcomes. Conclusions Comparable to other proximally fixed short stem designs, the highest subsidence was observed within the first 3 months following implantation. No demographic or implant-related factors were found to have a statistically significant influence on stem subsidence. Periprosthetic radiolucency and subsidence of the AMISstem is not correlated with worse clinical outcomes at 5-year follow-up.
Collapse
Affiliation(s)
- Julian Hasler
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland.
| | - Andreas Flury
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Dimitris Dimitriou
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Iris Holweg
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Naeder Helmy
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| | - Michael Finsterwald
- Departement of Orthopaedics and Traumatology, Bürgerspital Solothurn, Solothurn, Switzerland
| |
Collapse
|
19
|
Hu H, Liu Z, Liu B, Ding X, Liu S, Wu T, Ma W, Han Y. Comparison of Clinical Outcomes, Radiological Outcomes and Bone Remodeling Outcomes Between Proximal Coated Single-Wedge New Stem and Full Coated Dual-Wedge Classic Stem in 1-Stage Bilateral Total Hip Arthroplasty. Med Sci Monit 2020; 26:e921847. [PMID: 32001666 PMCID: PMC7006600 DOI: 10.12659/msm.921847] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Background This retrospective study investigated the clinical outcomes, radiological outcomes, and bone remodeling patterns associated with a Medial/Lateral Taper (M/L Taper) stem and Link Classic Uncemented (LCU) stem in 1-stage bilateral total hip arthroplasty (THA). Material/Methods The results of 52 patients who underwent 1-stage bilateral THA with a M/L Taper stem on one side and an LCU stem on the other between January 2012 and February 2015 were retrospectively compared. Patients were clinically assessed by the Harris hip score (HHS), visual analogue score (VAS) and incidence of complications. Radiological indicators were measured. Periprosthetic bone remodeling was assessed via bone mineral density (BMD) measurements. Results The mean follow-up time was 5.2 years. At each follow-up, there was no difference in the HHS and VAS between the 2 groups. The neck-shaft angle, offset, vertical height of the rotational center and limb lengthening were lower in the M/L Taper group than in the LCU group (P<0.001). The Engh total score was lower in the LCU group (P=0.039). Significantly higher (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 1, 2, and 6. significantly lower (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 3 and 5. Conclusions Due to the increased postoperative neck-shaft angle, the full coated dual-wedge classic stem was prone to cause lower limb lengthening. The proximal coated single-wedge new stem patients were more likely to have an insufficient postoperative neck length. The new stem achieved load transfer and proximal fixation, leading to better proximal femoral bone preservation is more in line with human biomechanical characteristics.
Collapse
Affiliation(s)
- Hongpeng Hu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Zeming Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Bo Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Xuzhuang Ding
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Sikai Liu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Tao Wu
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Wenhui Ma
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| | - Yongtai Han
- Department of Osteonecrosis and Hip Surgery, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China (mainland)
| |
Collapse
|
20
|
Hochreiter J, Mattiassich G, Ortmaier R, Steinmair M, Anderl C. Femoral bone remodeling after short-stem total hip arthroplasty: a prospective densitometric study. INTERNATIONAL ORTHOPAEDICS 2020; 44:753-759. [PMID: 31965311 DOI: 10.1007/s00264-020-04486-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Accepted: 01/15/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE Due to improved prosthesis designs and surgical techniques, indications for total hip arthroplasty (THA) now include younger and more active patients. Preserving bone stock and soft tissue in these patients is paramount to allow for future revision. Designed for anatomical reconstruction, short femoral stems have the potential to reduce adaptive bone loss and stress shielding. To confirm this, we evaluated bone remodeling around a short femoral stem and the accuracy of hip joint reconstruction. METHODS This prospective observational study involved 46 patients with short-stem THA for clinical and radiographic analysis. We evaluated bone remodeling by Gruen zone using dual-energy X-ray absorptiometry in 45 patients and assessed the accuracy of hip joint reconstruction using caput-collum-diaphyseal angles. Additionally, we reported functional scores and pain. RESULTS Patients were followed for a mean of 24.1 (SD 2.2) months. Bone mineral density increased mainly in the lateral region (Gruen zones 2 and 3) and in the distal-medial region (Gruen zone 5), suggestive of lateral loading. Most caput-collum-diaphyseal angles remained stable after surgery, especially in patients with varus hips. Harris Hip Scores improved significantly, from 57.2 (SD 20.0) pre-operatively to 97.2 (SD 4.0) at 24 months post-operatively (P < 0.0001). Finally, we encountered one peri-operative dislocation but no post-operative complications. CONCLUSION Short femoral stems successfully limited stress shielding and minimized periprosthetic bone loss without compromising primary stability. We were able to accurately reconstruct anatomical relationships in most patients. Finally, excellent clinical outcomes and low complication rates confirmed the favourable results of short-stem THA. TRIAL REGISTRATION DRKS00017076.
Collapse
Affiliation(s)
- Josef Hochreiter
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.
| | - Georg Mattiassich
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.,Ludwig-Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - Reinhold Ortmaier
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.,Research Unit of Orthopedic Sports Medicine and Injury Prevention, Institute for Sports Medicine, Alpine Medicine and Health Tourism (ISAG), UMIT, Eduard-Wallnöfer-Zentrum 1, 6060, Hall in Tirol, Austria
| | - Martin Steinmair
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria
| | - Conrad Anderl
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria
| |
Collapse
|
21
|
Schaer MO, Finsterwald M, Holweg I, Dimitriou D, Antoniadis A, Helmy N. Migration analysis of a metaphyseal-anchored short femoral stem in cementless THA and factors affecting the stem subsidence. BMC Musculoskelet Disord 2019; 20:604. [PMID: 31831070 PMCID: PMC6909646 DOI: 10.1186/s12891-019-2980-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 11/29/2019] [Indexed: 01/14/2023] Open
Abstract
Background Early femoral stem subsidence following a cementless THA is correlated with aseptic loosening of the femoral component. The short femoral stems allow bone sparing and implantation through a minimally invasive approach; however, due to their metaphyseal anchoring, they might demonstrate different subsidence pattern than the conventional stems. Methods In this prospective single-center study, a total of 68 consecutive patients with an average age of 63 years, and a minimum follow-up of 5 years following a cementless THA with a metaphyseal-anchored short femoral stem were included. The femoral stem subsidence was evaluated using “Ein Bild Roentgen Analyse” (EBRA). Results Average stem migration was 0.96 +/− 0.76 mm at 3 months, 1.71 +/− 1.26 mm at 24 months, and 2.04+/− 1.42 mm at last follow-up 60 months postoperative. The only factor that affected migration was a stem size of 6 or more (r2 = 5.74; p = 0.039). Subdivision analysis revealed, that only in females migration appeared to be affected by stem size irrespective of weight but not in men (female stem size of 6 or more vs. less (Difference = − 1.48 mm, R2 = 37.5; p = 0.001). Migration did not have an impact on clinical outcome measures. Conclusions The examined metaphyseal-anchored short femoral stem showed the highest subsidence within the first 3 months postoperative, the implant began to stabilize at about 24 months but continued to slowly migrate with average total subsidence of 2.04 mm at 5 years following the THA. The amount of stem subsidence was not associated with worse clinical outcomes such as HHS, patient satisfaction, or pain.
Collapse
Affiliation(s)
- Michael O Schaer
- Department for Orthopedic Surgery and Traumatology, Buergerspital Solothurn, Schoengruenstrasse 42, 4500, Solothurn, Switzerland. .,Department for Orthopedic Surgery and Traumatology, Inselspital, University of Bern, Bern, Switzerland.
| | - Michael Finsterwald
- Department for Orthopedic Surgery and Traumatology, Buergerspital Solothurn, Schoengruenstrasse 42, 4500, Solothurn, Switzerland
| | - Iris Holweg
- Department for Orthopedic Surgery and Traumatology, Buergerspital Solothurn, Schoengruenstrasse 42, 4500, Solothurn, Switzerland
| | - Dimitris Dimitriou
- Department for Orthopedic Surgery and Traumatology, Buergerspital Solothurn, Schoengruenstrasse 42, 4500, Solothurn, Switzerland
| | - Alexander Antoniadis
- Department for Orthopedic Surgery and Traumatology, Buergerspital Solothurn, Schoengruenstrasse 42, 4500, Solothurn, Switzerland
| | - Naeder Helmy
- Department for Orthopedic Surgery and Traumatology, Buergerspital Solothurn, Schoengruenstrasse 42, 4500, Solothurn, Switzerland
| |
Collapse
|
22
|
Kutzner KP, Donner S, Loweg L, Rehbein P, Dargel J, Drees P, Pfeil J. Mid-term results of a new-generation calcar-guided short stem in THA: clinical and radiological 5-year follow-up of 216 cases. J Orthop Traumatol 2019; 20:31. [PMID: 31673809 PMCID: PMC6823459 DOI: 10.1186/s10195-019-0537-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 08/23/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND In recent years, a variety of short stems have been introduced. To date, mid- and long-term results of calcar-guided short-stem designs have been rarely available. MATERIALS AND METHODS Two hundred and sixteen calcar-guided short stems were included in combination with a cementless cup in a prospective study. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) as well as pain and satisfaction on visual analogue scale (VAS) were assessed during a median follow-up of 61.7 months. Standardised radiographs were analysed at predefined time points regarding radiological alterations such as bone resorption and remodelling, radiolucency, osteolysis and cortical hypertrophy using modified Gruen zones. RESULTS At mid-term follow-up, no revision surgery of the stem had to be performed in the whole collective. At 5 years, HHS was 97.8 (SD 4.7), satisfaction on VAS was 9.7 (SD 0.7), rest pain on VAS was 0.1 (SD 0.5), and load pain on VAS was 0.6 (SD 1.2). Compared to the 2-year results, femoral bone resorption increased significantly at the 5-year follow-up (3.9% versus 42.3%). Rate of femoral cortical hypertrophy remained stable, occurring in a total of 9 hips (4.5%). At the 5-year follow-up, 2 stems (1.0%) showed non-progressive radiolucent lines with a maximum width of 2 mm. Signs of osteolysis were not observed. Compared to the 2-year follow-up, no further subsidence was observed. CONCLUSIONS The rate of stem revision (0%) at the mid-term follow-up was remarkable and indicates the principle of using a calcar-guided short stem as being a safe procedure. However, signs of bone-remodelling, indicating some amount of stress-shielding, must be acknowledged at 5 years depending on stem alignment and type of anchorage. LEVEL OF EVIDENCE IV, Prospective observational study Trial registration German Clinical Trials Register, DRKS00012634, 07/07/2017 (retrospectively registered).
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany. .,Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany.
| | - Stefanie Donner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Lennard Loweg
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Joachim Pfeil
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| |
Collapse
|
23
|
Anderson PA, Morgan SL, Krueger D, Zapalowski C, Tanner B, Jeray KJ, Krohn KD, Lane JP, Yeap SS, Shuhart CR, Shepherd J. Use of Bone Health Evaluation in Orthopedic Surgery: 2019 ISCD Official Position. J Clin Densitom 2019; 22:517-543. [PMID: 31519473 DOI: 10.1016/j.jocd.2019.07.013] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 07/16/2019] [Indexed: 02/07/2023]
Abstract
This position development conference (PDC) Task Force examined the assessment of bone status in orthopedic surgery patients. Key questions included which orthopedic surgery patients should be evaluated for poor bone health prior to surgery and which subsets of patients are at high risk for poor bone health and adverse outcomes. Second, the reliability and validity of using bone densitometry techniques and measurement of specific geometries around the hip and knee before and after arthroplasty was determined. Finally, the use of computed tomography (CT) attenuation coefficients (Hounsfield units) to estimate bone quality at anatomic locations where orthopedic surgery is performed including femur, tibia, shoulder, wrist, and ankle were reviewed. The literature review identified 665 articles of which 198 met inclusion exclusion criteria and were selected based on reporting of methodology, reliability, or validity results. We recommend that the orthopedic surgeon be aware of established ISCD guidelines for determining who should have additional screening for osteoporosis. Patients with inflammatory arthritis, chronic corticosteroid use, chronic renal disease, and those with history of fracture after age 50 are at high risk of osteoporosis and adverse events from surgery and should have dual energy X-ray absorptiometry (DXA) screening before surgery. In addition to standard DXA, bone mineral density (BMD) measurement along the femur and proximal tibia is reliable and valid around implants and can provide valuable information regarding bone remodeling and identification of loosening. Attention to positioning, selection of regions of interest, and use of special techniques and software is required. Plain radiographs and CT provide simple, reliable methods to classify the shape of the proximal femur and to predict osteoporosis; these include the Dorr Classification, Cortical Index, and critical thickness. Correlation of these indices to central BMD is moderate to good. Many patients undergoing orthopedic surgery have had preoperative CT which can be utilized to assess regional quality of bone. The simplest method available on most picture archiving and communications systems is to simply measure a regions of interest and determine the mean Hounsfield units. This method has excellent reliability throughout the skeleton and has moderate correlation to DXA based on BMD. The prediction of outcome and correlation to mechanical strength of fixation of a screw or implant is unknown.
Collapse
Affiliation(s)
- Paul A Anderson
- Department of Orthopedics Surgery & Rehabilitation, University of Wisconsin UWMF Centennial Building, Madison, WI, USA.
| | - Sarah L Morgan
- UAB Osteoporosis Prevention and Treatment Clinic, University of Alabama Birmingham, Birmingham, AL, USA
| | - Diane Krueger
- University of Wisconsin, Osteoporosis Clinical Research Program, Madison, WI, USA
| | | | - Bobo Tanner
- Division Rheumatology, Vanderbilt University, Nashville, TN, USA
| | - Kyle J Jeray
- Greenville Health System, Deparment of Orthopaedic Surgery, Greenville, SC, USA
| | | | - Joseph P Lane
- Department of Orthopedic Surgery, Hospital for Special surgery, New York, USA
| | | | | | - John Shepherd
- University of Hawaii Cancer Center, University of Hawaii, Honolulu, HI, USA
| |
Collapse
|
24
|
Is there a significant decrease in the femoral cortical bone around Furlong ® stems after 18 years of follow-up? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 30:117-122. [PMID: 31468186 DOI: 10.1007/s00590-019-02539-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 08/27/2019] [Indexed: 10/26/2022]
Abstract
INTRODUCTION In the context of total hip arthroplasty (THA), there are several reasons that have motivated the development of short stems. It has been postulated that short stems allow a better conservation of the bone stock if compared to conventional stems. As far as we have knowledge, the quantitative loss of diaphyseal bone stock in patients with standard femoral stems has not been fully described. The aim of this study was to provide evidences about the thickness of the cortical bone at the diaphysis in patients who have undergone unilateral THA with Furlong® stems with a minimum follow-up of 18 years. PATIENTS AND METHODS A retrospective study of patients who underwent THA in a single hospital was performed. The inclusion criteria were patients who had undergone a non-cemented elective THA with a Furlong® stem, minimum follow-up of 18 years, and contralateral femur and hip without history of previous surgical procedures. The follow-up analysis was performed by means of radiological examinations performed at the last follow-up visit. Data related to the sex, age at surgery and adverse events registered during the follow-up were gathered. The cortical thickness index (CTI) and cortical thickness (CT) assessed at the last follow-up visit in anteroposterior pelvic X-rays were analyzed, both in the operated hip and in the non-operated hip (which was used as control). Calibration of the measurements was done by means of using the circumference of the head of the THA. RESULTS The total number of patients who met the inclusion criteria was 22. There were 14 women and eight men. There were 12 left hips. The mean age at the time of surgery was 59.32 ± 6.83 (range 50-70) years. The mean follow-up was 20.86 ± 1.90 (range 18-24) years. The CTI was found to be 11.93% greater in the non-operated hips. The CT measured at 3 cm and 6 cm from lesser trochanter, and at 9 cm from the greater trochanter, was found to be 21.64%, 15.33% and 18.73% greater in the non-operated hips, respectively. CONCLUSION After a minimum of 18 years from the implantation of a Furlong® stem, the bone density that surrounds the implant seems to involve a cortical bone ten percent less thick than the cortical bone of the non-operated contralateral side. With this stem, the cortical zones with less CT seem to be the lateral cortex at 9 cm from the greater trochanter, and the medial cortex at 3 and 6 cm from the lesser trochanter. LEVEL OF EVIDENCE III, retrospective case-control study.
Collapse
|
25
|
Drosos GI, Touzopoulos P. Short stems in total hip replacement: evidence on primary stability according to the stem type. Hip Int 2019; 29:118-127. [PMID: 30569737 DOI: 10.1177/1120700018811811] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND: As the prevalence of total hip replacement is increasing in younger patients, less invasive implants (short stems) are becoming more favourable. However, despite the advantages of these stems, clinical results with a follow-up of more than 10 years are limited to a very few stem designs. There has been an increase in publications recently - mechanical and clinical studies - concerning the primary stability of short stems. Primary stem stability is an important factor as it reflects final stem stabilisation and is related to the clinical results of the prosthesis. METHOD: We conducted a systematic review of the literature to retrieve evidence concerning primary implant stability in short stems - as expressed by implant micromotion and stem subsidence - according to our previously proposed short-stem classification. RESULTS: Mechanical in vitro studies on stem micromotion are very few and limited to type 2 "partial collum" short stems. The results are comparable to those of stems with a known long-term excellent clinical course. Clinical results concerning stem migration patterns are also limited to some of the commercially available short stems. Although comparative studies are very few, the results for most of the short stems are similar to those of standard stems. CONCLUSION: There are promising results concerning biomechanical studies of the initial micromotion of short stems, as well as clinical results of stem migration patterns. Long-term clinical studies are needed in order to confirm these findings. The existing literature concerns very few of the many commercially available implants.
Collapse
Affiliation(s)
- Georgios I Drosos
- 1 Department of Orthopaedic Surgery, University General Hospital of Alexandroupolis, Alexandroupolis, Greece.,2 Democritus University of Thrace, Komotini, Greece
| | - Panagiotis Touzopoulos
- 1 Department of Orthopaedic Surgery, University General Hospital of Alexandroupolis, Alexandroupolis, Greece
| |
Collapse
|
26
|
Freitag T, Fuchs M, Woelfle-Roos JV, Reichel H, Bieger R. Mid-term migration analysis of a femoral short-stem prosthesis: a five-year EBRA-FCA-study. Hip Int 2019; 29:128-133. [PMID: 29739256 DOI: 10.1177/1120700018772277] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: The objective of this study was to evaluate the mid-term migration pattern of a femoral short stem. METHODS: Implant migration of 73 femoral short-stems was assessed by Ein-Bild-Roentgen-Analysis Femoral-Component-Analysis (EBRA-FCA) 5 years after surgery. Migration pattern of the whole group was analysed and compared to the migration pattern of implants "at risk" with a subsidence of more than 1.5 mm 2 years postoperative. RESULTS: Mean axial subsidence was 1.1 mm (-5.0 mm to 1.5 mm) after 60 months. There was a statistical significant axial migration until 2 years postoperative with settling thereafter. 2 years after surgery 18 of 73 Implants were classified "at risk." Nevertheless, all stems showed secondary stabilisation in the following period with no implant failure neither in the group of implants with early stabilisation nor the group with extensive early onset migration. CONCLUSION: In summary, even in the group of stems with more pronounced early subsidence, delayed settling occurred in all cases. The determination of a threshold of critical early femoral short stem subsidence is necessary because of the differing migration pattern described in this study with delayed settling of the Fitmore stem 2 years postoperatively compared to early settling within the first postoperative year described for conventional stems.
Collapse
Affiliation(s)
- Tobias Freitag
- 1 Department of Orthopaedic Surgery, University of Ulm, Germany
| | - Michael Fuchs
- 1 Department of Orthopaedic Surgery, University of Ulm, Germany.,2 Centre for Musculoskeletal Surgery, Orthopaedic Department Charite, Berlin, Germany
| | | | - Heiko Reichel
- 1 Department of Orthopaedic Surgery, University of Ulm, Germany
| | - Ralf Bieger
- 1 Department of Orthopaedic Surgery, University of Ulm, Germany
| |
Collapse
|
27
|
Karachalios T, Palaiochorlidis E, Komnos G. Clinical relevance of bone remodelling around conventional and conservative (short-stem) total hip arthroplasty implants. Hip Int 2019; 29:4-6. [PMID: 30421637 DOI: 10.1177/1120700018810846] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Based on data from the existing literature, we can safely suggest that bone mineral changes around cementless and cemented conventional femoral stems, and conservative femoral stems, are not predictive of either satisfactory or unsatisfactory total hip arthroplasty long term clinical outcomes. Additionally, studies with a follow up shorter than 5-10 years are perhaps clinically irrelevant. These observations may be helpful in interpreting the existing literature.
Collapse
|
28
|
von Engelhardt LV, Breil-Wirth A, Kothny C, Seeger JB, Grasselli C, Jerosch J. Long-term results of an anatomically implanted hip arthroplasty with a short stem prosthesis (MiniHip TM). World J Orthop 2018; 9:210-219. [PMID: 30364820 PMCID: PMC6198291 DOI: 10.5312/wjo.v9.i10.210] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 06/17/2018] [Accepted: 06/28/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the clinical and radiological outcome nine and ten years after short-stemmed, bone preserving and anatomical hip arthroplasty with the MiniHipTM system.
METHODS In a prospective study, 186 patients underwent hip arthroplasty with a partial neck preserving short stem (MiniHipTM, Corin). Elderly patients were not excluded from this study, thus the mean age at the time of surgery was 59.3 years (range 32 to 82 years). Surgery and the follow-up assessments were performed at two Centers. Up until now, the mean follow-up was 112.5 ± 8.2 mo. The Oxford Hip Score (OHS) and the Hip Dysfunction Osteoarthritis and Outcome Score (HOOS) was assessed pre- and each year after surgery. The clinical follow-up was accompanied by standardized a.p. and axial radiological examinations. Periprosthetic lucencies, hypertrophies within the Gruen zones one to fourteen were assessed. A subsidence of the stem was investigated according to Morray and heterotopic ossifications were assessed according to Brooker.
RESULTS The OHS and HOOS improved from 18 ± 3.3 to 46 ± 2.0 and from 30 ± 8.3 to 95 ± 4.6 points, P < 0.001 respectively. There were no differences regarding age, etiology, friction pairings, etc., (P > 0.05). Two stems were revised due to a symptomatic subsidence four and twelve months postoperatively. Thus, the survivorship for aseptic loosening at nine to ten years was 98.66%. Including one stem revision due to a symptomatic exostosis, bursitis and thigh pain as well as one revision because of a septic stem loosening, the overall survival for the stem with revision for any reason was 97.32%. Besides one asymptomatic patient, radiological signs of a proximal stress-shielding, such as bone resorptions within the proximal Gruen zones, were not noticed. Findings suggesting a distal loading, e.g., bony hypertrophies or bone appositions of more than 2 mm, were also not detected.
CONCLUSION Regarding these first long-term results on the MiniHipTM, the implant performed exceedingly well with a high rate of survivorship for aseptic loosening. Our radiological results within the Gruen zones support the design rationale of the Minihip to provide a reliable metaphyseal anchoring with the expected proximal, more physiological load transfer. This might minimize or exclude a stress shielding which might be associated with thigh pain, proximal bone loss and an increased risk of aseptic loosening. The MiniHipTM is a reliable partial-neck retaining prosthesis with good a clinical long-term outcome in younger as well as elderly patients.
Collapse
Affiliation(s)
- Lars V von Engelhardt
- Faculty of Health, University of Witten/Herdecke, Witten 58448, Germany
- Department of Trauma Surgery Orthopedics and Sports Medicine, Katholisches Karl-Leisner Klinikum, Kleve 47533, Germany
| | - Andreas Breil-Wirth
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
| | | | - Jörn Bengt Seeger
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Giessen 35392, Germany
| | - Christian Grasselli
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
- Department of Orthopaedics and Traumatology, Waldburg-Zeil Clinic Tettnang, Tettnang 88069, Germany
| | - Joerg Jerosch
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
| |
Collapse
|
29
|
Augustin L, Boller S, Bobach C, Jahnke A, Ahmed GA, Rickert M, Ishaque BA. Development of periprosthetic bone mass density around the cementless Metha® short hip stem during three year follow up-a prospective radiological and clinical study. INTERNATIONAL ORTHOPAEDICS 2018; 43:2031-2037. [PMID: 30178069 DOI: 10.1007/s00264-018-4126-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Accepted: 08/21/2018] [Indexed: 01/25/2023]
Abstract
PURPOSE The purpose of this study was to check the concept of the cementless Metha® short hip stem in order to find out whether proximal physiological load transfer can be achieved. METHODS Fourty-three patients were included. Epidemiological factors were established. The Harris Hip Score was determined and measurement of bone mass density as well as osteodensitometric and radiological measurements was carried out pre-operatively, post-operatively, and after six, 12, 24, and 36 months. RESULTS Harris Hip Score improved from 55.9 ± 12.4 pre-operatively to 94.8 ± 8.2 after 36 months (p < 0.001). After initial reduction of bone density in zones 1 and 7 up to six months post-operatively, there was a steady approximation of bone density to the initial values (p < 0.05). CONCLUSION The Metha® short hip stem shows good clinical results. Furthermore, there is an increase of bone density in the proximal zones 1 and 7 between six and 36 months serving as a sign of physiological load transfer.
Collapse
Affiliation(s)
- Laura Augustin
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Sarah Boller
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Cathrein Bobach
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Alexander Jahnke
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstraße 29, 35392, Giessen, Germany
| | - Gafar Adam Ahmed
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Markus Rickert
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Bernd Alexander Ishaque
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
| |
Collapse
|
30
|
Abstract
Over the last two decades, several conservative femoral prostheses have been designed. The goals of conservative stems include: the spearing of the trochanteric bone stock; a more physiological loading in the proximal femur reducing the risk of stress shielding; and to avoid a long stem into the diaphysis preventing impingement with the femoral cortex and thigh pain. All stems designed to be less invasive than conventional uncemented stems are commonly named ‘short stems’. However, this term is misleading because it refers to a heterogeneous group of stems deeply different in terms of design, biomechanics and bearing. In the short-term follow-up, all conservative stems provided excellent survivorship. However, variable rates of complications were reported, including stem malalignment, incorrect stem sizing and intra-operative fracture. Radiostereometric analysis (RSA) studies demonstrated that some conservative stems were affected by an early slight migration and rotation within the first months after surgery, followed by a secondary stable fixation. Dual-energy x-ray absorptiometry (DEXA) studies demonstrated an implant-specific pattern of bone remodelling. Although the vast majority of stems demonstrated a good osseointegration, some prostheses transferred loads particularly to the lateral and distal-medial regions, favouring proximal stress shielding and bone atrophy in the great trochanter and calcar regions.
Cite this article: EFORT Open Rev 2018;3:149-159. DOI: 10.1302/2058-5241.3.170052
Collapse
Affiliation(s)
- Mattia Loppini
- Department of Biomedical Sciences, Humanitas University, Italy; Hip Diseases and Joint Replacement Surgery Unit, Humanitas Clinical and Research Center, Italy
| | - Guido Grappiolo
- Hip Diseases and Joint Replacement Surgery Unit, Humanitas Clinical and Research Center, Italy
| |
Collapse
|
31
|
Yan SG, Weber P, Steinbrück A, Hua X, Jansson V, Schmidutz F. Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review. INTERNATIONAL ORTHOPAEDICS 2017; 42:2077-2086. [DOI: 10.1007/s00264-017-3691-z] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2017] [Accepted: 11/09/2017] [Indexed: 01/26/2023]
|
32
|
Yan SG, Li D, Yin S, Hua X, Tang J, Schmidutz F. Periprosthetic bone remodeling of short cementless femoral stems in primary total hip arthroplasty: A systematic review and meta-analysis of randomized-controlled trials. Medicine (Baltimore) 2017; 96:e8806. [PMID: 29381984 PMCID: PMC5708983 DOI: 10.1097/md.0000000000008806] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
BACKGROUND Short-stem total hip arthroplasty (SHA) has been increasingly used in the treatment of hip arthroplasty. However, it is unclear whether there is a superiority of SHA in periprosthetic bone remodeling over standard stem total hip arthroplasty (THA). This meta-analysis of randomized-controlled trials (RCTs) compared the periprosthetic bone remodeling after SHA and THA. METHODS PubMed and Embase were screened for relevant publications up to May 2017. RCTs that compared periprosthetic bone remodeling with bone mineral density (BMD) changes between SHA and THA were included. Meta-analysis was conducted to calculate weighted mean differences (WMDs) and 95% confidence intervals (CIs) using Stata version 12.0. Quality appraisal was performed by 2 independent reviewers using RevMan 5.3 software and Grades of Recommendation Assessment, Development, and Evaluation criteria. RESULTS Seven studies involving 910 patients and 5 SHA designs (Proxima, Fitmore, Microplasty short, Unique custom, and Omnifit-HA 1017) were included for meta-analysis. The pooled data showed no significant differences in the percentage BMD changes in all Gruen zones, with Gruen zone 1 [mean difference (MD) = 11.33, 95% CI, -1.67 to 24.33; P = .09] and Gruen zone 7 (MD = 8.46, 95% CI, -1.73 to 18.65; P = .10). Subgroup analysis of short SHA stems with lateral flare showed a significant less percentage BMD changes compared with standard THA in Gruen zone 1 (MD = 27.57, 95% CI, 18.03-37.12; P < .0001) and Gruen zone 7 (MD = 18.54, 95% CI, 8.27-28.81; P < .0001). CONCLUSION The study shows moderate-quality evidence that periprosthetic bone remodeling around the analyzed SHA stems was similar to standard THA stems. However, short SHA stems with lateral flare revealed a moderate- to low-quality evidence for superiority over the standard THA and highlighted the importance of the different SHA designs. Besides, it has to be noticed that despite a similar pattern of periprosthetic bone remodeling, the femoral length where periprosthetic bone remodeling occurs is clearly shorter in SHA. Due to the moderate- to low-quality evidence and the limited stem designs analyzed, the further large-scale multicenter RCTs including the most recent SHA designs are required. However, the current findings should be considered by surgeons for counseling patients regarding total hip replacement.
Collapse
Affiliation(s)
- Shuang G Yan
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University of Munich (LMU), Munich, Germany Department of Orthopedic Surgery, The First Affiliated Hospital of Anhui Medical University, Hefei Department of Orthopedic Surgery, Changhai Hospital, The Second Military Medical University, Shanghai, China BG Trauma Center, Eberhard Karls University Tübingen, Tuebingen, Germany
| | | | | | | | | | | |
Collapse
|
33
|
Fischer M, Beckmann NA, Simank HG. Bone remodelling around the Metha ® short stem implant - Clinical and dual-energy x-ray absorptiometry (DXA) results. J Orthop 2017; 14:525-529. [PMID: 28860687 DOI: 10.1016/j.jor.2017.08.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Accepted: 08/06/2017] [Indexed: 01/29/2023] Open
Abstract
OBJECTIVE Bony ingrowth of short stems is under investigation. METHOD Over one year bony reactions around the Metha® stem were investigated using the DXA method in a standardized zonal system (19 ROIs). Clinical results were documented using the HHS. RESULTS HHS significantly improved from 46 points to 97 points. After one year bone marrow density (BMD) increased in the lateral distal and lateral proximal areas as well as in the mid medial area. BMD decreased in the proximal medial and mid lateral areas. CONCLUSION The concept of metaphyseal ingrowth was confirmed, but distal bony reactions need further investigation.
Collapse
Affiliation(s)
- Markus Fischer
- Orthopädisches Centrum Hochfranken, Klinik Münchberg, Eppenreuther Str. 28, 95032 Hof, Germany
| | - Nicholas A Beckmann
- Orthopädische Universitätsklinik Heidelberg, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany
| | - Hans-Georg Simank
- Orthopädisches Centrum Hochfranken, Klinik Münchberg, Eppenreuther Str. 28, 95032 Hof, Germany
| |
Collapse
|
34
|
High incidence of early subtrochanteric lateral cortical atrophy after hip arthroplasty using bone-conserving short stem. INTERNATIONAL ORTHOPAEDICS 2017; 42:303-309. [PMID: 28681227 DOI: 10.1007/s00264-017-3544-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Accepted: 06/14/2017] [Indexed: 01/23/2023]
Abstract
PURPOSE Load transfer to the bone is believed to be more physiological around the short stem in total hip arthroplasty (THA). However, we found unusual bony remodeling around the shortened tapered stem. This study was performed to investigate the extent and frequency of this phenomenon and to find the possible risk factors of it. METHODS Among 121 consecutive THA using the same short stem, 80 THAs were enrolled. Radiographic measurements were made using anteroposterior (AP) radiographs taken immediately and at two years after surgery. The thickness of the lateral cortex at the level of the distal end of the coated surface and at 10, 20, 30, and 40 mm proximal to it were measured. RESULTS Significant atrophy was noted in all regions (P < 0.001 each). In 46 cases, this presented as an intra-cortical osteolytic line (IOL). Sixty-one cases showed either an IOL or atrophy >10%. The risk of a mean reduction >20% was related to an increased operating time (odds ratio [OR] = 0.981; 0.966 < 95% confidence interval [CI] < 0.996) and lower body mass index (BMI) (OR = 1.216; 1.043 < 95% CI < 1.417). Periprosthetic fracture through the lateral cortex occurred in one case. CONCLUSION Even with THA using a shortened stem, high incidence of proximal stress shielding was noted in the form of lateral cortical atrophy, especially for the patient with low BMI.
Collapse
|
35
|
Ercan A, Sokkar SM, Schmid G, Filler TJ, Abdelkafy A, Jerosch J. Periprosthetic bone density changes after MiniHip TM cementless femoral short stem: one-year results of dual-energy X-ray absorptiometry study. SICOT J 2016; 2:40. [PMID: 27855776 PMCID: PMC5115060 DOI: 10.1051/sicotj/2016033] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 10/07/2016] [Indexed: 02/06/2023] Open
Abstract
Introduction: The purpose of the current study was to investigate the reaction of the femur to the implantation of the MiniHipTM in terms of: (1) bone density change during one year; (2) correlations between stem length, CCD (caput-collum-diaphyseal), femoral offset, T-value, and bone density; (3) other co-variables that influence the change of bone density. Patients and methods: MiniHipTM implant was performed for 62 patients. The age range of the patients who underwent treatment was 25–78 years. Periprothestic bone density was determined within two weeks postoperatively, after three, six, and twelve months utilizing the DEXA scan. Results: The highest change was observed in the first three months post-implantation, while significant decrease in density was recorded at proximal Gruen zones 1, 2, and 7, and at distal Gruen zone 4. The decrease in density reached a plateau between the third and sixth months after operation. Afterwards, bone density recovered up to the 12th postoperative month. The correlation analysis showed significant difference between Gruen zone 1 and stem size and CCD. The same significant trend was not reached for Gruen zone 7. Femoral offset showed no correlation. Covariance analysis was unable to establish connection of the results with diagnosis, pairings, or gender. Discussion: MiniHipTM densitometric results are promising and comparable to good results of the other representatives of the femoral neck partially-sustaining short stem prostheses with a lower proximal bone density reduction. Periprosthetic bone resorption is a multifactorial process where stem size, CCD angle, and patient-specific variables such as T-value have an impact on the periprosthetic bone remodeling. In particular, this applies to Gruen zone 1.
Collapse
Affiliation(s)
- Ahmet Ercan
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, AM Hasenberg 46, 41462 Neuss, Germany
| | - Sherif M Sokkar
- Orthopaedic Surgery and Traumatology Department, Suez Canal University, Circular Road, 41522 Ismailia, Egypt
| | - Gebhard Schmid
- Department of Diagnostic Radiology, Johanna Etienne Hospital, AM Hasenberg 46, 41462 Neuss, Germany
| | - Timm J Filler
- Department of Anatomy, Heinrich-Heine University of Duesseldorf, Universitaetsstrasse 1, 40225 Duesseldorf, Germany
| | - Ashraf Abdelkafy
- Orthopaedic Surgery and Traumatology Department, Suez Canal University, Circular Road, 41522 Ismailia, Egypt
| | - Joerg Jerosch
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, AM Hasenberg 46, 41462 Neuss, Germany
| |
Collapse
|
36
|
One-stage bilateral versus unilateral short-stem total hip arthroplasty: comparison of migration patterns using "Ein-Bild-Roentgen-Analysis Femoral-Component-Analysis". INTERNATIONAL ORTHOPAEDICS 2016; 41:61-66. [PMID: 27075867 DOI: 10.1007/s00264-016-3184-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Accepted: 03/27/2016] [Indexed: 12/22/2022]
Abstract
PURPOSE The hypothesis of this study was that femoral implant migration would not differ between simultaneous bilateral or unilateral short-stem THA. METHOD Implant migration of 202 femoral short-stems (100 unilateral and 102 one-stage bilateral cases) in 151 patients was assessed by "Ein-Bild-Roentgen-Analysis Femoral-Component-Analysis" in a two years follow-up (2.0-3.0 years). Migration patterns of unilateral and simultaneous cases were analysed and compared. RESULTS There was no difference between the two groups regarding age, body mass index and gender. After two years mean subsidence of all 202 implants was 1.43 mm (-6.5 mm to 2.0 mm). After initial subsidence of 0.37 mm per month within the first six weeks, the mean monthly migration was reduced to 0.02 mm between one and two years post-operative. There was no statistical difference in mean migration between unilateral (1.34 mm) and simultaneous bilateral (1.51 mm) THA (p = 0.33). CONCLUSION In summary, two years post-operative there was no difference in the amount of mean implant subsidence between unilateral compared to simultaneous bilateral short-stem THA. This suggests that regarding implant fixation simultaneous bilateral short-stem THA is as safe and successful as a solely unilateral intervention.
Collapse
|