Ren W, Zhang K, Zhao Z, Zhang X, Lin F, Li Y, Bao K, Yang J, Chang J, Li J. Biomechanical characteristics of Sanders type II and III calcaneal fractures fixed by open reduction and internal fixation and percutaneous minimally invasive fixation. J Orthop Surg Res 2024; 19:166. [PMID: 38443993 PMCID: PMC10916136 DOI: 10.1186/s13018-024-04606-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 01/31/2024] [Indexed: 03/07/2024] Open
Abstract
BACKGROUND This work investigated the differences in the biomechanical properties of open reduction and internal fixation (ORIF) and percutaneous minimally invasive fixation (PMIF) for the fixation of calcaneal fractures (Sanders type II and III calcaneal fractures as examples) through finite element analysis. METHODS Based on CT images of the human foot and ankle, according to the principle of three-point fixation, namely the sustentaculum tali, the anterior process and the calcaneal tuberosity were fixed. Three-dimensional finite element models of Sanders type II and III calcaneal fractures fixed by ORIF and PMIF were established. The proximal surfaces of the tibia, fibula and soft tissue were constrained, and ground reaction force and Achilles tendon force loads were added to simulate balanced standing. RESULTS The maximum stress was 80.54, 211.59 and 113.88 MPa for the calcaneus, screws and plates in the ORIF group and 70.02 and 209.46 MPa for the calcaneus and screws in the PMIF group, respectively; the maximum displacement was 0.26, 0.21 and 0.12 mm for the calcaneus, screws and plates in the ORIF group and 0.20 and 0.14 mm for the calcaneus and screws in the PMIF group, respectively. The values obtained from the simulation were within the permissible stress and elastic deformation range of the materials used in the model, and there was no significant stress concentration. The maximum stress and displacement of the calcaneus and implants were slightly lower in the PMIF group than in the ORIF group when fixing Sanders type II and III calcaneal fractures. CONCLUSIONS This study may provide a reference for optimising the design of implants, the development of individualised preoperative plans and the choice of clinical surgical approach.
Collapse
Affiliation(s)
- Wu Ren
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
- Engineering Technology Research Center of Neurosense and Control of Henan Province, Xinxiang Engineering Technology Research Center of Intelligent Rehabilitation Equipment, Xinxiang, 453003, Henan, China
| | - Kailu Zhang
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
- Engineering Technology Research Center of Neurosense and Control of Henan Province, Xinxiang Engineering Technology Research Center of Intelligent Rehabilitation Equipment, Xinxiang, 453003, Henan, China
| | - Ziya Zhao
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
- Engineering Technology Research Center of Neurosense and Control of Henan Province, Xinxiang Engineering Technology Research Center of Intelligent Rehabilitation Equipment, Xinxiang, 453003, Henan, China
| | - Xueling Zhang
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
- Engineering Technology Research Center of Neurosense and Control of Henan Province, Xinxiang Engineering Technology Research Center of Intelligent Rehabilitation Equipment, Xinxiang, 453003, Henan, China
| | - Fei Lin
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
| | - Yawei Li
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
| | - Ke Bao
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China
| | - Jun Yang
- Hunan Normal University, Changsha, 410000, Hunan, China
| | - Jinlong Chang
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China.
- Engineering Technology Research Center of Neurosense and Control of Henan Province, Xinxiang Engineering Technology Research Center of Intelligent Rehabilitation Equipment, Xinxiang, 453003, Henan, China.
| | - Jia Li
- The First Affiliated Hospital of Xinxiang Medical University, School of Medical Engineering, Xinxiang Medical University, Xinxiang, 453003, Henan, China.
- Engineering Technology Research Center of Neurosense and Control of Henan Province, Xinxiang Engineering Technology Research Center of Intelligent Rehabilitation Equipment, Xinxiang, 453003, Henan, China.
| |
Collapse
|
2
|
Unified validation of a refined second-generation HR-pQCT based homogenized finite element method to predict strength of the distal segments in radius and tibia. J Mech Behav Biomed Mater 2022; 131:105235. [DOI: 10.1016/j.jmbbm.2022.105235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 02/28/2022] [Accepted: 04/10/2022] [Indexed: 11/22/2022]
|
3
|
Porrelli D, Abrami M, Pelizzo P, Formentin C, Ratti C, Turco G, Grassi M, Canton G, Grassi G, Murena L. Trabecular bone porosity and pore size distribution in osteoporotic patients - A low field nuclear magnetic resonance and microcomputed tomography investigation. J Mech Behav Biomed Mater 2021; 125:104933. [PMID: 34837800 DOI: 10.1016/j.jmbbm.2021.104933] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 10/10/2021] [Accepted: 10/25/2021] [Indexed: 01/19/2023]
Abstract
The study of bone morphology is of great importance as bone morphology is influenced by factors such as age and underlying comorbidities and is associated with bone mechanical properties and fracture risk. Standard diagnostic techniques used in bone disease, such as Dual-Energy X-ray absorptiometry and ultrasonography do not provide qualitative and quantitative morphological information. In recent years, techniques such as High Resolution Computed Tomography (HR-CT), micro- CT, Magnetic Resonance Imaging (MRI), and Low Field Nuclear Magnetic Resonance (LF-NMR) have been developed for the study of bone structure and porosity. Data obtained from these techniques have been used to construct models to predict bone mechanical properties thanks to finite element analysis. Cortical porosity has been extensively studied and successfully correlated with disease progression and mechanical properties. Trabecular porosity and pore size distribution, however, have increasingly been taken into consideration to obtain a comprehensive analysis of bone pathology and mechanic. Therefore, we have decided to evaluate the ability of micro- CT (chosen for its high spatial resolving power) and LF-NMR (chosen to analyze the behavior of water molecules within trabecular bone pores) to characterize the morphology of trabecular bone in osteoporosis. Trabecular bone samples from human femoral heads collected during hip replacement surgery were from osteoporosis (test group) and osteoarthritis (control group) patients. Our data show that both micro- CT and LF-NMR can detect qualitative changes in trabecular bone (i.e., transition from plate-like to rod-like morphology). Micro- CT failed to detect significant differences in trabecular bone morphology parameters between osteoporotic and osteoarthritic specimens, with the exception of Trabecular Number and Connectivity Density, which are markers of osteoporosis progression. In contrast, LF-NMR was able to detect significant differences in porosity and pore size of trabecular bone from osteoporotic versus osteoarthritic (control) samples. However, only the combination of these two techniques allowed the detection of structural morphometric changes (increase in the larger pore fraction and enlargement of the larger pores) in the trabecular bone of osteoporotic specimens compared to osteoarthritic ones. In conclusion, the combined use of LF-NMR and micro- CT provides a valuable tool for characterizing the morphology of trabecular bone and may offer the possibility for a new approach to the study and modeling of bone mechanics in the context of aging and disease.
Collapse
Affiliation(s)
- Davide Porrelli
- Department of Medicine, Surgery and Health Sciences, Maggiore Ospital, Trieste University, Piazza dell'Ospitale 1, I-34125, Trieste, Italy
| | - Michela Abrami
- Department of Engineering and Architecture, University of Trieste, Via Valerio 6/A, I 34127, Trieste, Italy
| | - Patrizia Pelizzo
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, I-34149, Trieste, Italy
| | - Cristina Formentin
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, I-34149, Trieste, Italy
| | - Chiara Ratti
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, I-34149, Trieste, Italy
| | - Gianluca Turco
- Department of Medicine, Surgery and Health Sciences, Maggiore Ospital, Trieste University, Piazza dell'Ospitale 1, I-34125, Trieste, Italy
| | - Mario Grassi
- Department of Engineering and Architecture, University of Trieste, Via Valerio 6/A, I 34127, Trieste, Italy.
| | - Gianluca Canton
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, I-34149, Trieste, Italy
| | - Gabriele Grassi
- Department of Life Sciences, Cattinara University Hospital, Trieste University, Strada di Fiume 447, I-34149, Trieste, Italy
| | - Luigi Murena
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Strada di Fiume 447, I-34149, Trieste, Italy
| |
Collapse
|
4
|
Marcián P, Borák L, Zikmund T, Horáčková L, Kaiser J, Joukal M, Wolff J. On the limits of finite element models created from (micro)CT datasets and used in studies of bone-implant-related biomechanical problems. J Mech Behav Biomed Mater 2021; 117:104393. [PMID: 33647729 DOI: 10.1016/j.jmbbm.2021.104393] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 01/12/2021] [Accepted: 02/10/2021] [Indexed: 02/06/2023]
Abstract
Patient-specific approach is gaining a wide popularity in computational simulations of biomechanical systems. Simulations (most often based on the finite element method) are to date routinely created using data from imaging devices such as computed tomography which makes the models seemingly very complex and sophisticated. However, using a computed tomography in finite element calculations does not necessarily enhance the quality or even credibility of the models as these depend on the quality of the input images. Low-resolution (medical-)CT datasets do not always offer detailed representation of trabecular bone in FE models and thus might lead to incorrect calculation of mechanical response to external loading. The effect of image resolution on mechanical simulations of bone-implant interaction has not been thoroughly studied yet. In this study, the effect of image resolution on the modeling procedure and resulting mechanical strains in bone was analyzed on the example of cranial implant. For this purpose, several finite element models of bone interacting with fixation-screws were generated using seven computed tomography datasets of a bone specimen but with different image resolutions (ranging from micro-CT resolution of 25 μm to medical-CT resolution of 1250 μm). The comparative analysis revealed that FE models created from images of low resolution (obtained from medical computed tomography) can produce biased results. There are two main reasons: 1. Medical computed tomography images do not allow generating models with complex trabecular architecture which leads to substituting of the intertrabecular pores with a fictitious mass; 2. Image gray value distribution can be distorted resulting in incorrect mechanical properties of the bone and thus in unrealistic or even completely fictitious mechanical strains. The biased results of calculated mechanical strains can lead to incorrect conclusion, especially when bone-implant interaction is investigated. The image resolution was observed not to significantly affect stresses in the fixation screw itself; however, selection of bone material representation might result in significantly different stresses in the screw.
Collapse
Affiliation(s)
- Petr Marcián
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic
| | - Libor Borák
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology, Brno, Czech Republic.
| | - Tomáš Zikmund
- CEITEC - Central European Institute of Technology, Brno University of Technology, Czech Republic
| | - Ladislava Horáčková
- Department of Anatomy, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Jozef Kaiser
- CEITEC - Central European Institute of Technology, Brno University of Technology, Czech Republic
| | - Marek Joukal
- Department of Anatomy, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Jan Wolff
- Department of Oral and Maxillofacial Surgery, Division for Regenerative Orofacial Medicine, University Hospital Hamburg-Eppendorf, Hamburg, Germany; Fraunhofer Research Institution for Additive Manufacturing Technologies IAPT, Hamburg, Germany
| |
Collapse
|
5
|
Ohs N, Collins CJ, Atkins PR. Validation of HR-pQCT against micro-CT for morphometric and biomechanical analyses: A review. Bone Rep 2020; 13:100711. [PMID: 33392364 PMCID: PMC7772687 DOI: 10.1016/j.bonr.2020.100711] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/29/2020] [Accepted: 08/19/2020] [Indexed: 12/26/2022] Open
Abstract
High-resolution peripheral quantitative computed-tomography (HR-pQCT) has the potential to become a powerful clinical assessment and diagnostic tool. Given the recent improvements in image resolution, from 82 to 61 μm, this technology may be used to accurately quantify in vivo bone microarchitecture, a key biomarker of degenerative bone diseases. However, computational methods to assess bone microarchitecture were developed for micro computed tomography (micro-CT), a higher-resolution technology only available for ex vivo studies, and validation of these computational analysis techniques against the gold-standard micro-CT has been inconsistent and incomplete. Herein, we review methods for segmentation of bone compartments and microstructure, quantification of bone morphology, and estimation of mechanical strength using finite-element analysis, highlighting the need throughout for improved standardization across the field. Studies have relied on homogenous datasets for validation, which does not allow for robust comparisons between methods. Consequently, the adaptation and validation of novel segmentation approaches has been slow to non-existent, with most studies still using the manufacturer's segmentation for morphometric analysis despite the existence of better performing alternative approaches. The promising accuracy of HR-pQCT for capturing morphometric indices is overshadowed by considerable variability in outcomes between studies. For finite element analysis (FEA) methods, the use of disparate material models and FEA tools has led to a fragmented ability to assess mechanical bone strength with HR-pQCT. Further, the scarcity of studies comparing 62 μm HR-pQCT to the gold standard micro-CT leaves the validation of this imaging modality incomplete. This review revealed that without standardization, the capabilities of HR-pQCT cannot be adequately assessed. The need for a public, extendable, heterogeneous dataset of HR-pQCT and corresponding gold-standard micro-CT images, which would allow HR-pQCT users to benchmark existing and novel methods and select optimal methods depending on the scientific question and data at hand, is now evident. With more recent advancements in HR-pQCT, the community must learn from its past and provide properly validated technologies to ensure that HR-pQCT can truly provide value in patient diagnosis and care.
Collapse
Affiliation(s)
- Nicholas Ohs
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | | | - Penny R. Atkins
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
- Department of Osteoporosis, Inselspital, Bern, Switzerland
| |
Collapse
|
6
|
Falcinelli C, Whyne C. Image-based finite-element modeling of the human femur. Comput Methods Biomech Biomed Engin 2020; 23:1138-1161. [PMID: 32657148 DOI: 10.1080/10255842.2020.1789863] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Fracture is considered a critical clinical endpoint in skeletal pathologies including osteoporosis and bone metastases. However, current clinical guidelines are limited with respect to identifying cases at high risk of fracture, as they do not account for many mechanical determinants that contribute to bone fracture. Improving fracture risk assessment is an important area of research with clear clinical relevance. Patient-specific numerical musculoskeletal models generated from diagnostic images are widely used in biomechanics research and may provide the foundation for clinical tools used to quantify fracture risk. However, prior to clinical translation, in vitro validation of predictions generated from such numerical models is necessary. Despite adopting radically different models, in vitro validation of image-based finite element (FE) models of the proximal femur (predicting strains and failure loads) have shown very similar, encouraging levels of accuracy. The accuracy of such in vitro models has motivated their application to clinical studies of osteoporotic and metastatic fractures. Such models have demonstrated promising but heterogeneous results, which may be explained by the lack of a uniform strategy with respect to FE modeling of the human femur. This review aims to critically discuss the state of the art of image-based femoral FE modeling strategies, highlighting principal features and differences among current approaches. Quantitative results are also reported with respect to the level of accuracy achieved from in vitro evaluations and clinical applications and are used to motivate the adoption of a standardized approach/workflow for image-based FE modeling of the femur.
Collapse
Affiliation(s)
- Cristina Falcinelli
- Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, Canada
| | - Cari Whyne
- Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, Canada
| |
Collapse
|
7
|
Alcântara ACS, Assis I, Prada D, Mehle K, Schwan S, Costa-Paiva L, Skaf MS, Wrobel LC, Sollero P. Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis-A Survey. MATERIALS (BASEL, SWITZERLAND) 2019; 13:E106. [PMID: 31878356 PMCID: PMC6981613 DOI: 10.3390/ma13010106] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 12/26/2022]
Abstract
This paper provides a starting point for researchers and practitioners from biology, medicine, physics and engineering who can benefit from an up-to-date literature survey on patient-specific bone fracture modelling, simulation and risk analysis. This survey hints at a framework for devising realistic patient-specific bone fracture simulations. This paper has 18 sections: Section 1 presents the main interested parties; Section 2 explains the organzation of the text; Section 3 motivates further work on patient-specific bone fracture simulation; Section 4 motivates this survey; Section 5 concerns the collection of bibliographical references; Section 6 motivates the physico-mathematical approach to bone fracture; Section 7 presents the modelling of bone as a continuum; Section 8 categorizes the surveyed literature into a continuum mechanics framework; Section 9 concerns the computational modelling of bone geometry; Section 10 concerns the estimation of bone mechanical properties; Section 11 concerns the selection of boundary conditions representative of bone trauma; Section 12 concerns bone fracture simulation; Section 13 presents the multiscale structure of bone; Section 14 concerns the multiscale mathematical modelling of bone; Section 15 concerns the experimental validation of bone fracture simulations; Section 16 concerns bone fracture risk assessment. Lastly, glossaries for symbols, acronyms, and physico-mathematical terms are provided.
Collapse
Affiliation(s)
- Amadeus C. S. Alcântara
- Department of Computational Mechanics, School of Mechanical Engineering, University of Campinas—UNICAMP, Campinas, Sao Paulo 13083-860, Brazil; (A.C.S.A.); (D.P.)
| | - Israel Assis
- Department of Integrated Systems, School of Mechanical Engineering, University of Campinas—UNICAMP, Campinas, Sao Paulo 13083-860, Brazil;
| | - Daniel Prada
- Department of Computational Mechanics, School of Mechanical Engineering, University of Campinas—UNICAMP, Campinas, Sao Paulo 13083-860, Brazil; (A.C.S.A.); (D.P.)
| | - Konrad Mehle
- Department of Engineering and Natural Sciences, University of Applied Sciences Merseburg, 06217 Merseburg, Germany;
| | - Stefan Schwan
- Fraunhofer Institute for Microstructure of Materials and Systems IMWS, 06120 Halle/Saale, Germany;
| | - Lúcia Costa-Paiva
- Department of Obstetrics and Gynecology, School of Medical Sciences, University of Campinas—UNICAMP, Campinas, Sao Paulo 13083-887, Brazil;
| | - Munir S. Skaf
- Institute of Chemistry and Center for Computing in Engineering and Sciences, University of Campinas—UNICAMP, Campinas, Sao Paulo 13083-860, Brazil;
| | - Luiz C. Wrobel
- Institute of Materials and Manufacturing, Brunel University London, Uxbridge UB8 3PH, UK;
- Department of Civil and Environmental Engineering, Pontifical Catholic University of Rio de Janeiro, Rio de Janeiro 22451-900, Brazil
| | - Paulo Sollero
- Department of Computational Mechanics, School of Mechanical Engineering, University of Campinas—UNICAMP, Campinas, Sao Paulo 13083-860, Brazil; (A.C.S.A.); (D.P.)
| |
Collapse
|