1
|
Gierig M, Gaziano P, Wriggers P, Marino M. Post-angioplasty remodeling of coronary arteries investigated via a chemo-mechano-biological in silico model. J Biomech 2024; 166:112058. [PMID: 38537368 DOI: 10.1016/j.jbiomech.2024.112058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/20/2024] [Accepted: 03/21/2024] [Indexed: 04/13/2024]
Abstract
This work presents the application of a chemo-mechano-biological constitutive model of soft tissues for describing tissue inflammatory response to damage in collagen constituents. The material model is implemented into a nonlinear finite element formulation to follow up a coronary standard balloon angioplasty for one year. Numerical results, compared with available in vivo clinical data, show that the model reproduces the temporal dynamics of vessel remodeling associated with subintimal damage. Such dynamics are bimodular, being characterized by an early tissue resorption and lumen enlargement, followed by late tissue growth and vessel constriction. Applicability of the modeling framework in retrospective studies is demonstrated, and future extension towards prospective applications is discussed.
Collapse
Affiliation(s)
- Meike Gierig
- Institute of Continuum Mechanics, Leibniz University of Hannover, An der Universität 1, 30823 Garbsen, Germany
| | - Pierfrancesco Gaziano
- Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy
| | - Peter Wriggers
- Institute of Continuum Mechanics, Leibniz University of Hannover, An der Universität 1, 30823 Garbsen, Germany
| | - Michele Marino
- Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133 Rome, Italy.
| |
Collapse
|
2
|
Bajeu IT, Niculescu AG, Scafa-Udriște A, Andronescu E. Intrastent Restenosis: A Comprehensive Review. Int J Mol Sci 2024; 25:1715. [PMID: 38338993 PMCID: PMC10855438 DOI: 10.3390/ijms25031715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 01/24/2024] [Accepted: 01/29/2024] [Indexed: 02/12/2024] Open
Abstract
The primary objective of this paper is to delineate and elucidate the contemporary advancements, developments, and prevailing trajectories concerning intrastent restenosis (ISR). We aim to provide a thorough overview of the most recent developments in this area, covering various aspects such as pathophysiological insights, therapeutic approaches, and new strategies for tackling the complex challenges of ISR in modern clinical settings. The authors have undertaken a study to address a relatively new medical challenge, recognizing its significant impact on the morbidity and mortality of individuals with cardiovascular diseases. This effort is driven by the need to fully understand, analyze, and possibly improve the outcomes of this emerging medical issue within the cardiovascular disease field. We acknowledge its considerable clinical implications and the necessity for innovative methods to mitigate its effects on patient outcomes. Therefore, our emphasis was directed towards elucidating the principal facets of the condition's prevalence, expounding upon the foundational mechanisms underscoring conspicuous restenosis, and delineating the risk factors relevant in shaping the contemporary landscape of diagnostic and therapeutic modalities. This thorough examination aims to provide a comprehensive understanding of the various dimensions of the condition, including epidemiological data, pathophysiological complexities, and clinical considerations critical for evaluating and enhancing current diagnostic and treatment approaches.
Collapse
Affiliation(s)
- Ioan-Teodor Bajeu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica Bucharest, 1-7 Polizu St., 011061 Bucharest, Romania; (I.-T.B.); (A.-G.N.); (E.A.)
- Department of Cardiology, Clinical Emergency Hospital of Bucharest, Calea Floreasca 8, 014461 Bucharest, Romania
| | - Adelina-Gabriela Niculescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica Bucharest, 1-7 Polizu St., 011061 Bucharest, Romania; (I.-T.B.); (A.-G.N.); (E.A.)
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 90 Panduri Road, 050657 Bucharest, Romania
| | - Alexandru Scafa-Udriște
- Department of Cardiology, Clinical Emergency Hospital of Bucharest, Calea Floreasca 8, 014461 Bucharest, Romania
- Department Cardio-Thoracic Pathology, University of Medicine and Pharmacy Carol Davila, Eroii Sanitari Bvd. 8, 050474 Bucharest, Romania
| | - Ecaterina Andronescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica Bucharest, 1-7 Polizu St., 011061 Bucharest, Romania; (I.-T.B.); (A.-G.N.); (E.A.)
- Academy of Romanian Scientists, Ilfov No. 3, 050044 Bucharest, Romania
| |
Collapse
|
3
|
Zuo D, Chen D, Zhu M, Xue Q. Sensitivity analysis of the mechanical properties on atherosclerotic arteries rupture risk with an artificial neural network method. Comput Methods Biomech Biomed Engin 2024:1-12. [PMID: 38268436 DOI: 10.1080/10255842.2024.2305862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 12/28/2023] [Indexed: 01/26/2024]
Abstract
Considering the differences between individuals, in this paper, an uncertainty analysis model for predicting rupture risk of atherosclerotic arteries is established based on a back-propagation artificial neural network. The influence of isotropy and anisotropy on the rupture risk of atherosclerotic arteries is analyzed, and the results demonstrate the effectiveness of the artificial neural network in predicting the rupture risk. Moreover, the rupture risk of atherosclerotic arteries at different inflation sizes are simulated. This study contributes to a better understanding of the underlying mechanisms of atherosclerotic arteries rupture and promotes the advancement of artificial neural networks in atherosclerosis research.
Collapse
Affiliation(s)
- Di Zuo
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| | - Daye Chen
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| | - Mingji Zhu
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| | - Qiwen Xue
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| |
Collapse
|
4
|
Manjunatha K, Schaaps N, Behr M, Vogt F, Reese S. Computational modeling of in-stent restenosis: Pharmacokinetic and pharmacodynamic evaluation. Comput Biol Med 2023; 167:107686. [PMID: 37972534 DOI: 10.1016/j.compbiomed.2023.107686] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/11/2023] [Accepted: 11/06/2023] [Indexed: 11/19/2023]
Abstract
Persistence of the pathology of in-stent restenosis even with the advent of drug-eluting stents warrants the development of highly resolved in silico models. These computational models assist in gaining insights into the transient biochemical and cellular mechanisms involved and thereby optimize the stent implantation parameters. Within this work, an already established fully-coupled Lagrangian finite element framework for modeling the restenotic growth is enhanced with the incorporation of endothelium-mediated effects and pharmacological influences of rapamycin-based drugs embedded in the polymeric layers of the current generation drug-eluting stents. The continuum mechanical description of growth is further justified in the context of thermodynamic consistency. Qualitative inferences are drawn from the model developed herein regarding the efficacy of the level of drug embedment within the struts as well as the release profiles adopted. The framework is then intended to serve as a tool for clinicians to tune the interventional procedures patient-specifically.
Collapse
Affiliation(s)
- Kiran Manjunatha
- Institute of Applied Mechanics, RWTH Aachen University, Germany.
| | - Nicole Schaaps
- Department of Cardiology, Vascular Medicine and Intensive Care, RWTH Aachen University, Germany
| | - Marek Behr
- Chair for Computational Analysis of Technical Systems, RWTH Aachen University, Germany
| | - Felix Vogt
- Department of Cardiology, Vascular Medicine and Intensive Care, RWTH Aachen University, Germany
| | - Stefanie Reese
- Institute of Applied Mechanics, RWTH Aachen University, Germany
| |
Collapse
|
5
|
Qi W, Ooi A, Grayden DB, John SE. Computational Fluid Dynamics of Stent-Mounted Neural Interfaces in an Idealized Cerebral Venous Sinus . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082814 DOI: 10.1109/embc40787.2023.10341099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Hemodynamic changes in stented blood vessels play a critical role in stent-associated complications. The majority of work on the hemodynamics of stented blood vessels has focused on coronary arteries but not cerebral venous sinuses. With the emergence of endovascular electrophysiology, there is a growing interest in stenting cerebral blood vessels. We investigated the hemodynamic impact of a stent-mounted neural interface inside the cerebral venous sinus. The stent was virtually implanted into an idealized superior sagittal sinus (SSS) model. Local venous blood flow was simulated. Results showed that blood flow was altered by the stent, generating recirculation and low wall shear stress (WSS) around the device. However, the effect of the electrodes on blood flow was not prominent due to their small size. This is an early exploration of the hemodynamics of a stent-mounted neural interface. Future work will shed light on the key factors that influence blood flow and stenting outcomes.Clinical Relevance-The study investigates blood flow through a stent-based electrode array inside the cerebral venous sinus. The hemodynamic impact of the stent can provide insight into neointimal growth and thrombus formation.
Collapse
|
6
|
Karakoç A, Aksoy O, Taciroğlu E. Effects of leaflet curvature and thickness on the crimping stresses in transcatheter heart valve. J Biomech 2023; 156:111663. [PMID: 37295168 DOI: 10.1016/j.jbiomech.2023.111663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 05/04/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023]
Abstract
With the current advances and expertise in biomedical device technologies, transcatheter heart valves (THVs) have been drawing significant attention. Various studies have been carried out on their durability and damage by dynamic loading in operational conditions. However, very few numerical investigations have been conducted to understand the effects of leaflet curvature and thickness on the crimping stresses which arise during the surgical preparation processes. In order to contribute to the current state of the art, a full heart valve model was presented, the leaflet curvature and thickness of which were then parameterized so as to understand the stress generation as a result of the crimping procedure during the surgical preparations. The results show that the existence of stresses is inevitable during the crimping procedure, which is a reduction factor for valve durability. Especially, stresses on the leaflets at the suture sites connected with the skirt were deduced to be critical and may result in leaflet ruptures after THV implantation.
Collapse
Affiliation(s)
- Alp Karakoç
- Aalto University, Department of Communications and Networking, 02150, Finland; Department of Civil and Environmental Engineering, University of California, Los Angeles, 90095, USA.
| | - Olcay Aksoy
- Division of Cardiology, Department of Medicine, University of California, Los Angeles, 90095, USA
| | - Ertuğrul Taciroğlu
- Department of Civil and Environmental Engineering, University of California, Los Angeles, 90095, USA
| |
Collapse
|
7
|
He R, Zhao L, Silberschmidt VV. Effect of balloon pre-dilation on performance of self-expandable nitinol stent in femoropopliteal artery. Biomech Model Mechanobiol 2023; 22:189-205. [PMID: 36282361 PMCID: PMC9957922 DOI: 10.1007/s10237-022-01641-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 09/19/2022] [Indexed: 11/24/2022]
Abstract
Balloon pre-dilation is usually performed before implantation of a nitinol stent in a femoropopliteal artery in a case of severe blockage or calcified plaque. However, its effect on performance of the nitinol stent in a diseased femoropopliteal artery has not been studied yet. This study compares the outcomes of stenting with pre-dilation and without it by modelling the entire processes of stent deployment. Fatigue deformation of the implanted stent is also modelled under diastolic-systolic blood pressure, repetitive bending, torsion, axial compression and their combination. Reduced level of stress in the stent occurs after stenting with pre-dilation, but causing the increased damage in the media layer, i.e. the middle layer of the arterial wall. Generally, pre-dilation increases the risk of nitinol stent's fatigue failure. Additionally, the development of in-stent restenosis is predicted based on the stenting-induced tissue damage in the media layer, and no severe mechanical irritation is induced to the media layer by pre-dilation, stent deployment or fatigue loading.
Collapse
Affiliation(s)
- Ran He
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK.
| | - Liguo Zhao
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU UK ,College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016 People’s Republic of China
| | - Vadim V. Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough, LE11 3TU UK
| |
Collapse
|
8
|
In silico evaluation of additively manufactured 316L stainless steel stent in a patient-specific coronary artery. Med Eng Phys 2022; 109:103909. [DOI: 10.1016/j.medengphy.2022.103909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 10/04/2022] [Accepted: 10/13/2022] [Indexed: 11/11/2022]
|
9
|
Manjunatha K, Behr M, Vogt F, Reese S. A multiphysics modeling approach for in-stent restenosis: Theoretical aspects and finite element implementation. Comput Biol Med 2022; 150:106166. [PMID: 36252366 DOI: 10.1016/j.compbiomed.2022.106166] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 09/19/2022] [Accepted: 10/01/2022] [Indexed: 11/21/2022]
Abstract
Development of in silico models that capture progression of diseases in soft biological tissues are intrinsic in the validation of the hypothesized cellular and molecular mechanisms involved in the respective pathologies. In addition, they also aid in patient-specific adaptation of interventional procedures. In this regard, a fully-coupled high-fidelity Lagrangian finite element framework is proposed within this work which replicates the pathology of in-stent restenosis observed post stent implantation in a coronary artery. Advection-reaction-diffusion equations are set up to track the concentrations of the platelet-derived growth factor, the transforming growth factor-β, the extracellular matrix, and the density of the smooth muscle cells. A continuum mechanical description of volumetric growth involved in the restenotic process, coupled to the evolution of the previously defined vessel wall constituents, is presented. Further, the finite element implementation of the model is discussed, and the behavior of the computational model is investigated via suitable numerical examples. Qualitative validation of the computational model is presented by emulating a stented artery. Patient-specific data are intended to be integrated into the model to predict the risk of in-stent restenosis, and thereby assist in the tuning of stent implantation parameters to mitigate the risk.
Collapse
Affiliation(s)
- Kiran Manjunatha
- Institute of Applied Mechanics, RWTH Aachen University, Germany.
| | - Marek Behr
- Chair for Computational Analysis of Technical Systems, RWTH Aachen University, Germany
| | - Felix Vogt
- Department of Cardiology, Pulmonology, Intensive Care and Vascular Medicine, RWTH Aachen University, Germany
| | - Stefanie Reese
- Institute of Applied Mechanics, RWTH Aachen University, Germany
| |
Collapse
|
10
|
McQueen A, Escuer J, Schmidt AF, Aggarwal A, Kennedy S, McCormick C, Oldroyd K, McGinty S. An intricate interplay between stent drug dose and release rate dictates arterial restenosis. J Control Release 2022; 349:992-1008. [PMID: 35921913 DOI: 10.1016/j.jconrel.2022.07.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/14/2022] [Accepted: 07/26/2022] [Indexed: 10/15/2022]
Abstract
Since the introduction of percutaneous coronary intervention (PCI) for the treatment of obstructive coronary artery disease (CAD), patient outcomes have progressively improved. Drug eluting stents (DES) that employ anti-proliferative drugs to limit excess tissue growth following stent deployment have proved revolutionary. However, restenosis and a need for repeat revascularisation still occurs after DES use. Over the last few years, computational models have emerged that detail restenosis following the deployment of a bare metal stent (BMS), focusing primarily on contributions from mechanics and fluid dynamics. However, none of the existing models adequately account for spatiotemporal delivery of drug and the influence of this on the cellular processes that drive restenosis. In an attempt to fill this void, a novel continuum restenosis model coupled with spatiotemporal drug delivery is presented. Our results indicate that the severity and time-course of restenosis is critically dependent on the drug delivery strategy. Specifically, we uncover an intricate interplay between initial drug loading, drug release rate and restenosis, indicating that it is not sufficient to simply ramp-up the drug dose or prolong the time course of drug release to improve stent efficacy. Our model also shows that the level of stent over-expansion and stent design features, such as inter-strut spacing and strut thickness, influence restenosis development, in agreement with trends observed in experimental and clinical studies. Moreover, other critical aspects of the model which dictate restenosis, including the drug binding site density are investigated, where comparisons are made between approaches which assume this to be either constant or proportional to the number of smooth muscle cells (SMCs). Taken together, our results highlight the necessity of incorporating these aspects of drug delivery in the pursuit of optimal DES design.
Collapse
Affiliation(s)
- Alistair McQueen
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK
| | - Javier Escuer
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | | | - Ankush Aggarwal
- Glasgow Computational Engineering Centre, Division of Infrastructure and Environment, University of Glasgow, Glasgow, UK
| | - Simon Kennedy
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | | | - Keith Oldroyd
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK; Glasgow Computational Engineering Centre, Division of Infrastructure and Environment, University of Glasgow, Glasgow, UK.
| |
Collapse
|
11
|
Mechanical and hydrodynamic effects of stent expansion in tapered coronary vessels. Biomech Model Mechanobiol 2022; 21:1549-1560. [PMID: 35867283 PMCID: PMC9626435 DOI: 10.1007/s10237-022-01605-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 06/24/2022] [Indexed: 11/25/2022]
Abstract
Percutaneous coronary intervention (PCI) has become the primary treatment for patients with coronary heart disease because of its minimally invasive nature and high efficiency. Anatomical studies have shown that most coronary vessels gradually shrink, and the vessels gradually become thinner from the proximal to the distal end. In this paper, the effects of different stent expansion methods on the mechanical and hemodynamic behaviors of coronary vessels and stents were studied. To perform a structural-mechanical analysis of stent implantation, the coronary vessels with branching vessels and the coronary vessels with large bending curvature are selected. The two characteristic structures are implanted in equal diameter expansion mode and conical expansion mode, and the stress and mechanical behaviors of the coronary vessels and stents are analyzed. The results of the structural-mechanical analysis showed that the mechanical behaviors and fatigue performance of the cobalt-chromium alloy stent were good, and the different expansion modes of the stent had little effect on the fatigue performance of the stent. However, the equal diameter expansion mode increased distal coronary artery stress and the risk of vascular injury. The computational fluid dynamics analysis results showed that different stent expansion methods had varied effects on coronary vessel hemodynamics and that the wall shear stress distribution of conical stent expansion is more uniform compared with equal diameter expansion. Additionally, the vortex phenomenon is not apparent, the blood flow velocity is slightly increased, the hydrodynamic environment is more reasonable, and the risk of coronary artery injury is reduced.
Collapse
|
12
|
He R, Zhao L, Silberschmidt VV, Feng J, Serracino-Inglott F. Personalised nitinol stent for focal plaques: Design and evaluation. J Biomech 2021; 130:110873. [PMID: 34883344 DOI: 10.1016/j.jbiomech.2021.110873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 11/01/2021] [Accepted: 11/16/2021] [Indexed: 10/19/2022]
Abstract
The purpose of this study is to develop personalised nitinol stents for arteries with one and two opposite focal plaques. Novel designs are evaluated through comparison with a commercial stent design, in terms of lumen gain and shape as well as stress levels in the media layer after stenting. METHODS Personalised stents are developed for arteries with one and two opposite focal plaques, based on medical imaging of patients and computer simulations. In silico analysis is then carried out for assessment of stent performance in the diseased arteries. RESULTS Personalised designs significantly increase the lumen gain, reduce the stresses in the media layer, and improve the lumen shape compared to the commercial nitinol stent. CONCLUSION The personalised designs show outstanding performance compared to the commercial stent. SIGNIFICANCE This pilot study proves that personalised nitinol stents are able to deliver desirable treatment outcomes.
Collapse
Affiliation(s)
- Ran He
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough LE11 3TU, UK.
| | - Liguo Zhao
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough LE11 3TU, UK
| | - Vadim V Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Epinal Way, Loughborough LE11 3TU, UK
| | - Jiling Feng
- Department of Engineering, Manchester Metropolitan University, Manchester M15 6BH, UK
| | | |
Collapse
|
13
|
Pioneering personalised design of femoropopliteal nitinol stents. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 130:112462. [PMID: 34702537 DOI: 10.1016/j.msec.2021.112462] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/20/2021] [Accepted: 09/24/2021] [Indexed: 11/23/2022]
Abstract
BACKGROUND/MOTIVATION Percutaneous femoropopliteal artery intervention moves towards personalised therapy, which requires design of unique lesion-specific stents. However, to date, not much progress has been made in the development of personalised stents. OBJECTIVE This paper aims to design personalised nitinol stents for femoropopliteal arteries based on medical imaging of patients and advanced computational mechanics, which is the first attempt to the authors' best knowledge. METHODS The design process is based on three objectives: (i) achieving the healthy lumen area; (ii) reducing the stress in the media layer; (iii) improving the lumen shape after stenting. The design parameters include the strut width and thickness, the crown length, the nominal radius and the number of strut units per crown. Using representative unit-cell models, the effects of the five geometric parameters on the stent performance are investigated thoroughly with numerical simulations. Then, design protocols, especially for the circumferentially varying strut size and the oval stent shape, are developed and fully evaluated for an asymmetric stenosis. RESULTS Using the design protocols, full personalised stents are designed for arteries with diffuse and focal plaques, based on medical imaging of patients. The personalised stent designs provide a double lumen gain, a reduced stress in the media layer and an improved lumen shape compared to a commercial stent. CONCLUSIONS The suggested protocols prove their high effectiveness in design of personalised stents, and the suggested approach can be applied to development of personalised therapies involving the use of stent technology including percutaneous coronary artery intervention, transcatheter aortic valve implantation, endovascular aneurysm repair and ureteric stenting.
Collapse
|
14
|
Antonini L, Berti F, Isella B, Hossain D, Mandelli L, Pennati G, Petrini L. From the real device to the digital twin: A coupled experimental-numerical strategy to investigate a novel bioresorbable vascular scaffold. PLoS One 2021; 16:e0252788. [PMID: 34086820 PMCID: PMC8177663 DOI: 10.1371/journal.pone.0252788] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 05/21/2021] [Indexed: 11/26/2022] Open
Abstract
The purpose of this work is to propose a workflow that couples experimental and computational activities aimed at developing a credible digital twin of a commercial coronary bioresorbable vascular scaffold when direct access to data about material mechanical properties is not possible. Such a situation is be faced when the manufacturer is not involved in the study, thus directly investigating the actual device is the only source of information available. The object of the work is the Fantom® Encore polymeric stent (REVA Medical) made of Tyrocore™. Four devices were purchased and used in mechanical tests that are easily reproducible in any mechanical laboratory, i.e. free expansion and uniaxial tension testing, the latter performed with protocols that emphasized the rate-dependent properties of the polymer. Given the complexity of the mechanical behaviour observed experimentally, it was chosen to use the Parallel Rehological Framework material model, already used in the literature to describe the behaviour of other polymers, such as PLLA. Calibration of the material model was based on simulations that replicate the tensile test performed on the device. Given the high number of material parameters, a plan of simulations was done to find the most suitable set, varying each parameter value in a feasible range and considering a single repetitive unit of the stent, neglecting residual stresses generated by crimping and expansion. This strategy resulted in a significant reduction of computational cost. The performance of the set of parameters thus identified was finally evaluated considering the whole delivery system, by comparing the experimental results with the data collected simulating free expansion and uniaxial tension testing. Moreover, radial force testing was numerically performed and compared with literature data. The obtained results demonstrated the effectiveness of the digital twin development pipeline, a path applicable to any commercial device whose geometric structure is based on repetitive units.
Collapse
Affiliation(s)
- Luca Antonini
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Francesca Berti
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Benedetta Isella
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Dipok Hossain
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Lorenzo Mandelli
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Giancarlo Pennati
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy
| | - Lorenza Petrini
- Department of Civil and Environmental Engineering, Politecnico di Milano, Milano, Italy
- * E-mail:
| |
Collapse
|
15
|
Maes L, Cloet AS, Fourneau I, Famaey N. A homogenized constrained mixture model of restenosis and vascular remodelling after balloon angioplasty. J R Soc Interface 2021; 18:20210068. [PMID: 33947223 DOI: 10.1098/rsif.2021.0068] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Restenosis is one of the main adverse effects of the treatment of atherosclerosis through balloon angioplasty or stenting. During the intervention, the arterial wall is overstretched, causing a cascade of cellular events and subsequent neointima formation. This mechanical stimulus and its mechanobiological effects can be reproduced in biomechanical simulations. The aim of these models is to predict the long-term outcome of these procedures, to help increase the understanding of restenosis formation and to allow for in silico optimization of the treatment. We propose a predictive finite-element model of restenosis, using the homogenized constrained mixture modelling framework designed to model growth and remodelling in soft tissues. We compare the results with clinical observations in human coronary arteries and experimental findings in non-human primate models. We also explore the model's clinical relevance by testing its response to different balloon loads and to the use of drug-eluting balloons. The comparison of the results with experimental data shows the relevance of the model. We show its ability to predict both inward and outward remodelling as observed in vivo and we show the importance of an improved understanding of restenosis formation from a biomechanical point of view.
Collapse
Affiliation(s)
- Lauranne Maes
- Biomechanics Section, Mechanical Engineering Department, KU Leuven, Celestijnenlaan 300, 3001 Leuven, Belgium
| | - An-Sofie Cloet
- Biomechanics Section, Mechanical Engineering Department, KU Leuven, Celestijnenlaan 300, 3001 Leuven, Belgium
| | - Inge Fourneau
- Department of Vascular Surgery, University Hospitals Leuven, Herestraat 49, 3000 Leuven, Belgium
| | - Nele Famaey
- Biomechanics Section, Mechanical Engineering Department, KU Leuven, Celestijnenlaan 300, 3001 Leuven, Belgium
| |
Collapse
|
16
|
张 晗, 张 愉, 陈 诗, 崔 新, 彭 坤, 乔 爱. [Review of studies on the biomechanical modelling of the coupling effect between stent degradation and blood vessel remodeling]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2020; 37:956-966. [PMID: 33369334 PMCID: PMC9929987 DOI: 10.7507/1001-5515.202008007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Indexed: 11/03/2022]
Abstract
The dynamic coupling of stent degradation and vessel remodeling can influence not only the structural morphology and material property of stent and vessel, but also the development of in-stent restenosis. The research achievements of biomechanical modelling and analysis of stent degradation and vessel remodeling were reviewed; several noteworthy research perspectives were addressed, a stent-vessel coupling model was developed based on stent damage function and vessel growth function, and then concepts of matching ratio and risk factor were established so as to evaluate the treatment effect of stent intervention, which may lay the scientific foundation for the structure design, mechanical analysis and clinical application of biodegradable stent.
Collapse
Affiliation(s)
- 晗冰 张
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 愉 张
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 诗亮 陈
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 新阳 崔
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 坤 彭
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| | - 爱科 乔
- 北京工业大学 环境与生命学部(北京 100124)Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China
| |
Collapse
|
17
|
He S, Liu W, Qu K, Yin T, Qiu J, Li Y, Yuan K, Zhang H, Wang G. Effects of different positions of intravascular stent implantation in stenosed vessels on in-stent restenosis: An experimental and numerical simulation study. J Biomech 2020; 113:110089. [PMID: 33181394 DOI: 10.1016/j.jbiomech.2020.110089] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Revised: 09/08/2020] [Accepted: 10/16/2020] [Indexed: 11/29/2022]
Abstract
Percutaneous coronary intervention (PCI) has been widely used in the treatment of atherosclerosis, while in-stent restenosis (ISR) has not been completely resolved. Studies have shown that changes in intravascular mechanical environment are related to ISR. Hence, an in-depth understanding of the effects of stent intervention on vascular mechanics is important for clinically optimizing stent implantation and relieving ISR. Nine rabbits with stenotic carotid artery were collected by balloon injury. Intravascular stents were implanted into different longitudinal positions (proximal, middle and distal relative to the stenotic area) of the stenotic vessels for numerical simulations. Optical coherence tomography (OCT) scanning was performed to reconstruct the three-dimensional configuration of the stented carotid artery and blood flow velocity waveforms were collected by Doppler ultrasound. The numerical simulations were performed through direct solution of Naiver-Stokes equation in ANSYS. Results showed that the distributions of time-averaged wall shear stress (TAWSS), oscillating shear index (OSI) and relative residual time (RRT) in near-end segment were distinctively different from other regions of the stent which considered to promote restenosis for all three models. Spearman rank-correlation analysis showed a significant correlation between hemodynamic descriptors and the stent longitudinal positions (rTAWSS = -0.718, rOSI = 0.898, rRRT = 0.818, p < 0.01). Histology results of the near-end segment showed neointima thickening deepened with the longitudinal positions of stent which was consistent with the numerical simulations. The results suggest that stent implantation can promote restenosis at the near-end segment. As the stenting position moves to distal end, the impact on ISR is more significant.
Collapse
Affiliation(s)
- Shicheng He
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, PR China
| | - Wanling Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Kai Qu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Tieying Yin
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Juhui Qiu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China.
| | - Yan Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China
| | - Kunshan Yuan
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, Shandong 251100, PR China
| | - Haijun Zhang
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, Shandong 251100, PR China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, PR China.
| |
Collapse
|
18
|
Geith MA, Nothdurfter L, Heiml M, Agrafiotis E, Gruber M, Sommer G, Schratzenstaller TG, Holzapfel GA. Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations. Acta Biomater 2020; 116:285-301. [PMID: 32858190 DOI: 10.1016/j.actbio.2020.08.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/28/2020] [Accepted: 08/12/2020] [Indexed: 11/18/2022]
Abstract
Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device 'LAESIO' that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations.
Collapse
Affiliation(s)
- Markus A Geith
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Biomedical Engineering Department, King's College London, London, United Kingdom
| | | | - Manuel Heiml
- Institute of Biomechanics, Graz University of Technology, Graz, Austria
| | | | | | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Graz, Austria
| | - Thomas G Schratzenstaller
- Medical Device Laboratory, Regensburg Center of Biomedical Engineering, Technical University of Applied Sciences Regensburg, Regensburg, Germany
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway.
| |
Collapse
|