1
|
Padkan N, Bigham BS, Faraji MR. Fingerprint matching using the onion peeling approach and turning function. Gene Expr Patterns 2023; 47:119299. [PMID: 36513184 DOI: 10.1016/j.gep.2022.119299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 10/07/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022]
Abstract
Fingerprint, as one of the most popular and robust biometric traits, can be used in automatic identification and verification systems to identify individuals. Fingerprint matching is a vital and challenging issue in fingerprint recognition systems. Most fingerprint matching algorithms are minutiae-based. The minutiae points are the ways that the fingerprint ridges can be discontinuous. Ridge ending and ridge bifurcation are two frequently used minutiae in most fingerprint matching algorithms. This article presents a new minutiae-based fingerprint matching using the onion peeling approach. In the proposed method, fingerprints are aligned to find the matched minutiae points. Then, the nested convex polygons of matched minutiae points are constructed and the comparison between peer-to-peer polygons is performed by the turning function distance. Simplicity, accuracy, and low time complexity of the onion peeling approach are three important factors that make it a standard method for fingerprint matching purposes. The performance of the proposed algorithm is evaluated on the database FVC2002. Since the fingerprints that the difference between the number of their layers is more than 2 and the a minutiae matching score lower than 0.15 are ignored, better results are obtained. KEYWORDS: Fingerprint Matching, Minutiae, Convex Layers, Turning Function, Computational Geometry.
Collapse
Affiliation(s)
- Nazanin Padkan
- Department of Computer Science and Information Technology, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran.
| | - B Sadeghi Bigham
- Department of Computer Science and Information Technology, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran; Department of Computer Science, Faculty of Mathematical Sciences, Alzahra University, Tehran, Iran.
| | - Mohammad Reza Faraji
- Department of Computer Science and Information Technology, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran.
| |
Collapse
|
2
|
Wang D, Zhao H, Li Q. An image retrieval method of mammary cancer based on convolutional neural network. JOURNAL OF INTELLIGENT & FUZZY SYSTEMS 2020. [DOI: 10.3233/jifs-179386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Dan Wang
- Department of Computer Science and Technology, Jilin University, Changchun, China
- College of Information Technology and Media, Beihua University, Jilin, China
| | - Hongwei Zhao
- Department of Computer Science and Technology, Jilin University, Changchun, China
- State Key Laboratory of Applied Optics, Changchun, China
- Department of Symbolic Computing and Knowledge Engineering, Key Laboratory of the Ministry of Education, Jilin University, Changchun, China
| | - Qingliang Li
- Changchun University of Science and Technology, Changchun, China
- Department of Symbolic Computing and Knowledge Engineering, Key Laboratory of the Ministry of Education, Jilin University, Changchun, China
| |
Collapse
|
3
|
Rodríguez-Cristerna A, Gómez-Flores W, de Albuquerque Pereira WC. A computer-aided diagnosis system for breast ultrasound based on weighted BI-RADS classes. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 153:33-40. [PMID: 29157459 DOI: 10.1016/j.cmpb.2017.10.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Revised: 08/23/2017] [Accepted: 10/02/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND AND OBJECTIVE Conventional computer-aided diagnosis (CAD) systems for breast ultrasound (BUS) are trained to classify pathological classes, that is, benign and malignant. However, from a clinical perspective, this kind of classification does not agree totally with radiologists' diagnoses. Usually, the tumors are assessed by using a BI-RADS (Breast Imaging-Reporting and Data System) category and, accordingly, a recommendation is emitted: annual study for category 2 (benign), six-month follow-up study for category 3 (probably benign), and biopsy for categories 4 and 5 (suspicious of malignancy). Hence, in this paper, a CAD system based on BI-RADS categories weighted by pathological information is presented. The goal is to increase the classification performance by reducing the common class imbalance found in pathological classes as well as to provide outcomes quite similar to radiologists' recommendations. METHODS The BUS dataset considers 781 benign lesions and 347 malignant tumors proven by biopsy. Moreover, every lesion is associated to one BI-RADS category in the set {2, 3, 4, 5}. Thus, the dataset is split into three weighted classes: benign, BI-RADS 2 in benign lesions; probably benign, BI-RADS 3 and 4 in benign lesions; and malignant, BI-RADS 4 and 5 in malignant lesions. Thereafter, a random forest (RF) classifier, denoted by RFw, is trained to predict the weighted BI-RADS classes. In addition, for comparison purposes, a RF classifier is trained to predict pathological classes, denoted as RFp. RESULTS The ability of the classifiers to predict the pathological classes is measured by the area under the ROC curve (AUC), sensitivity (SEN), and specificity (SPE). The RFw classifier obtained AUC=0.872,SEN=0.826, and SPE=0.919, whereas the RFp classifier reached AUC=0.868,SEN=0.808, and SPE=0.929. According to a one-way analysis of variance test, the RFw classifier statistically outperforms (p < 0.001) the RFp classifier in terms of the AUC and SEN. Moreover, the classification performance of RFw to predict weighted BI-RADS classes is given by the Matthews correlation coefficient that obtained 0.614. CONCLUSIONS The division of the classification problem into three classes reduces the imbalance between benign and malignant classes; thus, the sensitivity is increased without degrading the specificity. Therefore, the CAD based on weighted BI-RADS classes improves the classification performance of the conventional CAD systems. Additionally, the proposed approach has the advantage of being capable of providing a multiclass outcome related to radiologists' recommendations.
Collapse
Affiliation(s)
- Arturo Rodríguez-Cristerna
- Center for Research and Advanced Studies of the National Polytechnic Institute, ZIP 87130, Ciudad Victoria, Tamaulipas, Mexico
| | - Wilfrido Gómez-Flores
- Center for Research and Advanced Studies of the National Polytechnic Institute, ZIP 87130, Ciudad Victoria, Tamaulipas, Mexico.
| | | |
Collapse
|
4
|
Li H, Meng X, Wang T, Tang Y, Yin Y. Breast masses in mammography classification with local contour features. Biomed Eng Online 2017; 16:44. [PMID: 28410616 PMCID: PMC5391548 DOI: 10.1186/s12938-017-0332-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2016] [Accepted: 03/20/2017] [Indexed: 12/03/2022] Open
Abstract
Background Mammography is one of the most popular tools for early detection of breast cancer. Contour of breast mass in mammography is very important information to distinguish benign and malignant mass. Contour of benign mass is smooth and round or oval, while malignant mass has irregular shape and spiculated contour. Several studies have shown that 1D signature translated from 2D contour can describe the contour features well. Methods In this paper, we propose a new method to translate 2D contour of breast mass in mammography into 1D signature. The method can describe not only the contour features but also the regularity of breast mass. Then we segment the whole 1D signature into different subsections. We extract four local features including a new contour descriptor from the subsections. The new contour descriptor is root mean square (RMS) slope. It can describe the roughness of the contour. KNN, SVM and ANN classifier are used to classify benign breast mass and malignant mass. Results The proposed method is tested on a set with 323 contours including 143 benign masses and 180 malignant ones from digital database of screening mammography (DDSM). The best accuracy of classification is 99.66% using the feature of root mean square slope with SVM classifier. Conclusion The performance of the proposed method is better than traditional method. In addition, RMS slope is an effective feature comparable to most of the existing features. Electronic supplementary material The online version of this article (doi:10.1186/s12938-017-0332-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Haixia Li
- School of Computer Science and Technology, Shandong University, Jinan, 250101, China.,School of Information, Shandong University of Political Science and Law, Jinan, 250014, China
| | - Xianjing Meng
- School of Computer Science and Technology, Shandong University of Finance and Economics, Jinan, 250014, China
| | - Tingwen Wang
- School of Computer Science and Technology, Shandong University of Finance and Economics, Jinan, 250014, China
| | - Yuchun Tang
- Research Center for Sectional and Imaging Anatomy, Shandong University School of Medicine, Jinan, 250012, China
| | - Yilong Yin
- School of Computer Science and Technology, Shandong University, Jinan, 250101, China. .,School of Computer Science and Technology, Shandong University of Finance and Economics, Jinan, 250014, China.
| |
Collapse
|
5
|
Niehaus R, Raicu DS, Furst J, Armato S. Toward Understanding the Size Dependence of Shape Features for Predicting Spiculation in Lung Nodules for Computer-Aided Diagnosis. J Digit Imaging 2016; 28:704-17. [PMID: 25708891 DOI: 10.1007/s10278-015-9774-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
We analyze the importance of shape features for predicting spiculation ratings assigned by radiologists to lung nodules in computed tomography (CT) scans. Using the Lung Image Database Consortium (LIDC) data and classification models based on decision trees, we demonstrate that the importance of several shape features increases disproportionately relative to other image features with increasing size of the nodule. Our shaped-based classification results show an area under the receiver operating characteristic (ROC) curve of 0.65 when classifying spiculation for small nodules and an area of 0.91 for large nodules, resulting in a 26% difference in classification performance using shape features. An analysis of the results illustrates that this change in performance is driven by features that measure boundary complexity, which perform well for large nodules but perform relatively poorly and do no better than other features for small nodules. For large nodules, the roughness of the segmented boundary maps well to the semantic concept of spiculation. For small nodules, measuring directly the complexity of hard segmentations does not yield good results for predicting spiculation due to limits imposed by spatial resolution and the uncertainty in boundary location. Therefore, a wider range of features, including shape, texture, and intensity features, are needed to predict spiculation ratings for small nodules. A further implication is that the efficacy of shape features for a particular classifier used to create computer-aided diagnosis systems depends on the distribution of nodule sizes in the training and testing sets, which may not be consistent across different research studies.
Collapse
Affiliation(s)
- Ron Niehaus
- School of Computing, DePaul University, 243 S. Wabash Avenue, Chicago, IL, 60604, USA.
| | - Daniela Stan Raicu
- School of Computing, DePaul University, 243 S. Wabash Avenue, Chicago, IL, 60604, USA
| | - Jacob Furst
- School of Computing, DePaul University, 243 S. Wabash Avenue, Chicago, IL, 60604, USA
| | - Samuel Armato
- Department of Radiology, University of Chicago, Chicago, IL, USA
| |
Collapse
|
6
|
|
7
|
Kendall EJ, Barnett MG, Chytyk-Praznik K. Automatic detection of anomalies in screening mammograms. BMC Med Imaging 2013; 13:43. [PMID: 24330643 PMCID: PMC4029799 DOI: 10.1186/1471-2342-13-43] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Accepted: 12/09/2013] [Indexed: 11/16/2022] Open
Abstract
Background Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. Methods In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. Results The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Conclusions Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%.
Collapse
Affiliation(s)
- Edward J Kendall
- Discipline of Radiology, Janeway Child Health Centre, Memorial University of Newfoundland, Newfoundland A1B 3V6, Canada.
| | | | | |
Collapse
|
8
|
Alvarenga AV, Infantosi AFC, Pereira WCA, Azevedo CM. Assessing the combined performance of texture and morphological parameters in distinguishing breast tumors in ultrasound images. Med Phys 2013; 39:7350-8. [PMID: 23231284 DOI: 10.1118/1.4766268] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE This work aims to investigate the combination of morphological and texture parameters in distinguishing between malignant and benign breast tumors in ultrasound images. METHODS Linear discriminant analysis was applied to sets of up to five parameters, and then the performances were assessed using the area A(z) (± standard error) under the receiver operator characteristic curve, accuracy (Ac), sensitivity (Se), specificity (Sp), positive predictive value, and negative predictive value. RESULTS The most relevant individual parameter was the normalized residual value (nrv), calculated from the convex polygon technique. The best performance among all studied combinations was achieved by two morphological and three texture parameters (nrv, con, std, R, and asm(i)), which correctly distinguished nearly 85% of the breast tumors. CONCLUSIONS This result indicates that the combination of morphological and texture parameters may be useful to assist physicians in the diagnostic process, especially if it is associated with an automatic classification tool.
Collapse
|
9
|
|
10
|
Liu J, Chen J, Liu X, Chun L, Tang J, Deng Y. Mass segmentation using a combined method for cancer detection. BMC SYSTEMS BIOLOGY 2011; 5 Suppl 3:S6. [PMID: 22784625 PMCID: PMC3287574 DOI: 10.1186/1752-0509-5-s3-s6] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background Breast cancer is one of the leading causes of cancer death for women all over the world and mammography is thought of as one of the main tools for early detection of breast cancer. In order to detect the breast cancer, computer aided technology has been introduced. In computer aided cancer detection, the detection and segmentation of mass are very important. The shape of mass can be used as one of the factors to determine whether the mass is malignant or benign. However, many of the current methods are semi-automatic. In this paper, we investigate fully automatic segmentation method. Results In this paper, a new mass segmentation algorithm is proposed. In the proposed algorithm, a fully automatic marker-controlled watershed transform is proposed to segment the mass region roughly, and then a level set is used to refine the segmentation. For over-segmentation caused by watershed, we also investigated different noise reduction technologies. Images from DDSM were used in the experiments and the results show that the new algorithm can improve the accuracy of mass segmentation. Conclusions The new algorithm combines the advantages of both methods. The combination of the watershed based segmentation and level set method can improve the efficiency of the segmentation. Besides, the introduction of noise reduction technologies can reduce over-segmentation.
Collapse
Affiliation(s)
- Jun Liu
- College of Computer Science and Technology, Wuhan University of Science and Technology, Wuhan, Hubei, China
| | | | | | | | | | | |
Collapse
|
11
|
Alvarenga AV, Infantosi AFC, Pereira WCA, Azevedo CM. Assessing the performance of morphological parameters in distinguishing breast tumors on ultrasound images. Med Eng Phys 2009; 32:49-56. [PMID: 19926514 DOI: 10.1016/j.medengphy.2009.10.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2009] [Revised: 10/06/2009] [Accepted: 10/12/2009] [Indexed: 11/16/2022]
Abstract
This work aims at investigating seven morphological parameters in distinguishing malignant and benign breast tumors on ultrasound images. Linear discriminant analysis was applied to sets of up to five parameters and then the performances were assessed using the area Az (+/- standard error) under the ROC curve, accuracy (Ac), sensitivity (Se), specificity (Sp), positive predictive value and negative predictive value. The most relevant individual parameters were the normalized residual value (nrv) and overlap ratio (RS), both calculated from the convex polygon technique, and the circularity (C). When nrv and C were taken together with roughness (R), calculated from normalized radial length (NRL), a performance slightly over 83% in distinguishing malignant and benign breast tumors was achieved.
Collapse
Affiliation(s)
- André Victor Alvarenga
- Laboratory of Ultrasound, National Institute of Metrology, Standardization, and Industrial Quality (Inmetro), Av. N. Sra. das Gracas, 50 - Xerem, 25250-020 Duque de Caxias, Rio de Janeiro, Brazil.
| | | | | | | |
Collapse
|