1
|
Seghier ML. 7 T and beyond: toward a synergy between fMRI-based presurgical mapping at ultrahigh magnetic fields, AI, and robotic neurosurgery. Eur Radiol Exp 2024; 8:73. [PMID: 38945979 PMCID: PMC11214939 DOI: 10.1186/s41747-024-00472-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Accepted: 04/22/2024] [Indexed: 07/02/2024] Open
Abstract
Presurgical evaluation with functional magnetic resonance imaging (fMRI) can reduce postsurgical morbidity. Here, we discuss presurgical fMRI mapping at ultra-high magnetic fields (UHF), i.e., ≥ 7 T, in the light of the current growing interest in artificial intelligence (AI) and robot-assisted neurosurgery. The potential of submillimetre fMRI mapping can help better appreciate uncertainty on resection margins, though geometric distortions at UHF might lessen the accuracy of fMRI maps. A useful trade-off for UHF fMRI is to collect data with 1-mm isotropic resolution to ensure high sensitivity and subsequently a low risk of false negatives. Scanning at UHF might yield a revival interest in slow event-related fMRI, thereby offering a richer depiction of the dynamics of fMRI responses. The potential applications of AI concern denoising and artefact removal, generation of super-resolution fMRI maps, and accurate fusion or coregistration between anatomical and fMRI maps. The latter can benefit from the use of T1-weighted echo-planar imaging for better visualization of brain activations. Such AI-augmented fMRI maps would provide high-quality input data to robotic surgery systems, thereby improving the accuracy and reliability of robot-assisted neurosurgery. Ultimately, the advancement in fMRI at UHF would promote clinically useful synergies between fMRI, AI, and robotic neurosurgery.Relevance statement This review highlights the potential synergies between fMRI at UHF, AI, and robotic neurosurgery in improving the accuracy and reliability of fMRI-based presurgical mapping.Key points• Presurgical fMRI mapping at UHF improves spatial resolution and sensitivity.• Slow event-related designs offer a richer depiction of fMRI responses dynamics.• AI can support denoising, artefact removal, and generation of super-resolution fMRI maps.• AI-augmented fMRI maps can provide high-quality input data to robotic surgery systems.
Collapse
Affiliation(s)
- Mohamed L Seghier
- Department of Biomedical Engineering and Biotechnology, Khalifa University of Science and Technology, Abu Dhabi, UAE.
- Healtcare Engineering Innovation Center (HEIC), Khalifa University of Science and Technology, Abu Dhabi, UAE.
| |
Collapse
|
2
|
Qi Z, Jin H, Xu X, Wang Q, Gan Z, Xiong R, Zhang S, Liu M, Wang J, Ding X, Chen X, Zhang J, Nimsky C, Bopp MHA. Head model dataset for mixed reality navigation in neurosurgical interventions for intracranial lesions. Sci Data 2024; 11:538. [PMID: 38796526 PMCID: PMC11127921 DOI: 10.1038/s41597-024-03385-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 05/15/2024] [Indexed: 05/28/2024] Open
Abstract
Mixed reality navigation (MRN) technology is emerging as an increasingly significant and interesting topic in neurosurgery. MRN enables neurosurgeons to "see through" the head with an interactive, hybrid visualization environment that merges virtual- and physical-world elements. Offering immersive, intuitive, and reliable guidance for preoperative and intraoperative intervention of intracranial lesions, MRN showcases its potential as an economically efficient and user-friendly alternative to standard neuronavigation systems. However, the clinical research and development of MRN systems present challenges: recruiting a sufficient number of patients within a limited timeframe is difficult, and acquiring low-cost, commercially available, medically significant head phantoms is equally challenging. To accelerate the development of novel MRN systems and surmount these obstacles, the study presents a dataset designed for MRN system development and testing in neurosurgery. It includes CT and MRI data from 19 patients with intracranial lesions and derived 3D models of anatomical structures and validation references. The models are available in Wavefront object (OBJ) and Stereolithography (STL) formats, supporting the creation and assessment of neurosurgical MRN applications.
Collapse
Affiliation(s)
- Ziyu Qi
- Department of Neurosurgery, University of Marburg, Baldingerstrasse, 35043, Marburg, Germany.
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China.
| | - Haitao Jin
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Medical School of Chinese PLA General Hospital, 100853, Beijing, China
- NCO School, Army Medical University, 050081, Shijiazhuang, China
| | - Xinghua Xu
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
| | - Qun Wang
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
| | - Zhichao Gan
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Medical School of Chinese PLA General Hospital, 100853, Beijing, China
| | - Ruochu Xiong
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Department of Neurosurgery, Division of Medicine, Graduate School of Medical Sciences, Kanazawa University, Takara-machi 13-1, 920-8641, Kanazawa, Ishikawa, Japan
| | - Shiyu Zhang
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Medical School of Chinese PLA General Hospital, 100853, Beijing, China
| | - Minghang Liu
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Medical School of Chinese PLA General Hospital, 100853, Beijing, China
| | - Jingyue Wang
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Medical School of Chinese PLA General Hospital, 100853, Beijing, China
| | - Xinyu Ding
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
- Medical School of Chinese PLA General Hospital, 100853, Beijing, China
| | - Xiaolei Chen
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China
| | - Jiashu Zhang
- Department of Neurosurgery, First Medical Center of Chinese PLA General Hospital, 100853, Beijing, China.
| | - Christopher Nimsky
- Department of Neurosurgery, University of Marburg, Baldingerstrasse, 35043, Marburg, Germany
- Center for Mind, Brain and Behavior (CMBB), 35043, Marburg, Germany
| | - Miriam H A Bopp
- Department of Neurosurgery, University of Marburg, Baldingerstrasse, 35043, Marburg, Germany.
- Center for Mind, Brain and Behavior (CMBB), 35043, Marburg, Germany.
| |
Collapse
|
3
|
Kos TM, Colombo E, Bartels LW, Robe PA, van Doormaal TPC. Evaluation Metrics for Augmented Reality in Neurosurgical Preoperative Planning, Surgical Navigation, and Surgical Treatment Guidance: A Systematic Review. Oper Neurosurg (Hagerstown) 2023; 26:01787389-990000000-01007. [PMID: 38146941 PMCID: PMC11008635 DOI: 10.1227/ons.0000000000001009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/10/2023] [Indexed: 12/27/2023] Open
Abstract
BACKGROUND AND OBJECTIVE Recent years have shown an advancement in the development of augmented reality (AR) technologies for preoperative visualization, surgical navigation, and intraoperative guidance for neurosurgery. However, proving added value for AR in clinical practice is challenging, partly because of a lack of standardized evaluation metrics. We performed a systematic review to provide an overview of the reported evaluation metrics for AR technologies in neurosurgical practice and to establish a foundation for assessment and comparison of such technologies. METHODS PubMed, Embase, and Cochrane were searched systematically for publications on assessment of AR for cranial neurosurgery on September 22, 2022. The findings were reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. RESULTS The systematic search yielded 830 publications; 114 were screened full text, and 80 were included for analysis. Among the included studies, 5% dealt with preoperative visualization using AR, with user perception as the most frequently reported metric. The majority (75%) researched AR technology for surgical navigation, with registration accuracy, clinical outcome, and time measurements as the most frequently reported metrics. In addition, 20% studied the use of AR for intraoperative guidance, with registration accuracy, task outcome, and user perception as the most frequently reported metrics. CONCLUSION For quality benchmarking of AR technologies in neurosurgery, evaluation metrics should be specific to the risk profile and clinical objectives of the technology. A key focus should be on using validated questionnaires to assess user perception; ensuring clear and unambiguous reporting of registration accuracy, precision, robustness, and system stability; and accurately measuring task performance in clinical studies. We provided an overview suggesting which evaluation metrics to use per AR application and innovation phase, aiming to improve the assessment of added value of AR for neurosurgical practice and to facilitate the integration in the clinical workflow.
Collapse
Affiliation(s)
- Tessa M. Kos
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
- Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Elisa Colombo
- Department of Neurosurgery, Clinical Neuroscience Center, Universitätsspital Zürich, Zurich, The Netherlands
| | - L. Wilbert Bartels
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Pierre A. Robe
- Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Tristan P. C. van Doormaal
- Department of Neurosurgery, Clinical Neuroscience Center, Universitätsspital Zürich, Zurich, The Netherlands
- Department of Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
4
|
Colombo E, Bektas D, Regli L, van Doormaal T. Case report: Impact of mixed reality on anatomical understanding and surgical planning in a complex fourth ventricular tumor extending to the lamina quadrigemina. Front Surg 2023; 10:1227473. [PMID: 37675252 PMCID: PMC10477590 DOI: 10.3389/fsurg.2023.1227473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 07/21/2023] [Indexed: 09/08/2023] Open
Abstract
Background and importance Tumors of the fourth ventricle account for 1%-5% of all intracranial neoplastic lesions and present with different configurations and anatomical challenges. Microsurgery represents the primary therapeutic strategy for the majority of fourth ventricular tumors, and adequate anatomical understanding and visualization are paramount to surgical planning and success. The authors present the case of a young patient with a complex fourth ventricular tumor, whose surgery was successfully planned using a novel mixed reality (MxR) system. Case description We present a case of a 31-year-old woman with a lesion extending from the fourth ventricle to the lamina quadrigemina and causing symptomatic hydrocephalus occlusus. Through the combined use of routine 2D images and an interactive 3D anatomical model, an interhemispheric transtentorial approach was used to remove 98% of the lesion with successful functional outcomes. Conclusions The application of advanced 3D visualization with a novel MxR system to the surgical planning of a complex fourth ventricular lesion proved relevant in designing the best surgical approach and trajectory to better identify potential intraoperative challenges and rehearse the patient-specific anatomy. The present case report endorses the implementation of advanced 3D visualization in routine perioperative practice.
Collapse
Affiliation(s)
- Elisa Colombo
- Department of Neurosurgery and Clinical Neurocenter, University Hospital Zurich, Zurich, Switzerland
| | | | | | | |
Collapse
|