1
|
Alam W, Reineke S, Raja Viswanath M, Rusho RZ, Van Daele D, Meyer D, Liu J, Lingala SG. A flexible 16-channel custom coil array for accelerated imaging of upper and infraglottic airway at 3 T. Magn Reson Med 2023; 89:2117-2130. [PMID: 36484236 DOI: 10.1002/mrm.29559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 11/25/2022] [Accepted: 11/25/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE To develop a custom coil and evaluate its utility for accelerated upper and infraglottic airway MRI at 3 T. METHODS A 16-channel flexible and anatomy-conforming coil was developed to provide localized sensitivity over upper and infraglottic airway regions of interest. Parallel-imaging capabilities were compared against existing head and head-neck coils. SENSE geometry factor losses were quantified for retrospectively accelerating 3D MRI. Blinded image-quality ratings from two experts were performed. Spiral GRAPPA reconstructions were evaluated for a speaking task at a time resolution of 40 ms. Contrast-to-noise ratios between air and tissue at key landmarks along the vocal tract were compared. SENSE imaging with the custom coil in the lateral recumbent posture was evaluated. Multislice imaging was performed to image swallowing at 17 ms/frame via constrained reconstruction. RESULTS The custom coil showed improved SENSE imaging up to 3-fold acceleration when accelerated along either the anterior-posterior or the superior-inferior direction and a net 4-fold acceleration when accelerated along both directions. Spiral GRAPPA reconstructions with the custom coil showed higher contrast-to-noise ratio when compared with existing coils. In the lateral posture, robust SENSE imaging was achieved at up to 2-fold and 3-fold acceleration levels in the superior-inferior and anterior-posterior directions, respectively. Key events of swallowing in the multislice dynamic images were identified by an otolaryngologist. CONCLUSION The coil provided improved parallel imaging of upper and infraglottic airway in both supine and lateral recumbent postures. It enabled efficient accelerated dynamic imaging of speaking and swallowing.
Collapse
Affiliation(s)
- Wahidul Alam
- Roy J. Carver Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa, USA
| | | | | | - Rushdi Zahid Rusho
- Roy J. Carver Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa, USA
| | - Douglas Van Daele
- Department of Otolaryngology, The University of Iowa, Iowa City, Iowa, USA
| | - David Meyer
- Janette Ogg Voice Research Center, Shenandoah University, Winchester, Virginia, USA
| | - Junjie Liu
- Department of Neurology, The University of Iowa, Iowa City, Iowa, USA
| | - Sajan Goud Lingala
- Roy J. Carver Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa, USA.,Department of Radiology, The University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
2
|
Forner R, Nam K, de Koning KJ, van der Velden T, van der Kemp W, Raaijmakers A, Klomp DWJ. RF Coil Setup for 31P MRSI in Tongue Cancer in vivo at 7 T. Front Neurol 2021; 12:695202. [PMID: 34795625 PMCID: PMC8593189 DOI: 10.3389/fneur.2021.695202] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 09/10/2021] [Indexed: 11/20/2022] Open
Abstract
Surgery for tongue cancer often results in a major loss in quality of life. While MRI may be used to minimise the volume of excised tissue, often the full tumour extent is missed. This tumour extent may be detected with metabolic imaging. One of the main reasons for the lack of metabolic information on tongue cancer would be the absence of an x-nuclear coil with the tongue as a focus target. Metabolic MRI through 31P MRSI is known as a powerful tool to non-invasively study elevated cell proliferation and disturbed energy metabolism in tumours. Severe magnetic field non-uniformities are inherently caused by the substantial difference in magnetic susceptibilities of tissue and air in the mouth and its environs. Despite this, the wide chemical shift dispersion of 31P could still facilitate precise detection of the cell proliferation biomarkers, phospomonoesters and diesters, as well as energy metabolites ATP, inorganic phosphate, and phosphocreatine potentially mapped over the tongue or tumour in vivo. In this study, we present the first 31P MRSI data of the human tongue in vivo from healthy volunteers and a patient with a tongue tumour at 7 T MRI using a 1H 8-channel transceiver setup placed inside a body 31P transmitter, which is able to get a uniform excitation from the tongue while providing comfortable access to the patient. In addition, a user-friendly external 31P receiver array is used to provide high sensitivity (80%) comparable to an uncomfortable inner mouth loop coil positioned on the tongue. The primary aim is the demonstration of 31P metabolite profiles in the tongue and the differences between healthy and malignant tissue. Indeed, clear elevated cell proliferation expressed as enhanced phosphomonoesters is observed in the tumour vs. the healthy part of the tongue. This can be performed within a total scan duration of 30 min, comparable to clinical scans, with a spatial resolution of 1.5 cm for the 10-min 31P MRSI scan.
Collapse
Affiliation(s)
- Ria Forner
- Division of Imaging and Oncology, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands.,Ceresensa Inc., London, ON, Canada
| | - Kyungmin Nam
- Division of Imaging and Oncology, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands
| | - Klijs J de Koning
- Surgery, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands
| | - Tijl van der Velden
- Division of Imaging and Oncology, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands
| | - Wybe van der Kemp
- Division of Imaging and Oncology, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands
| | - Alexander Raaijmakers
- Division of Imaging and Oncology, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands.,Division of Biomedical Image Analyses, Technical University Eindhoven (TU/e), Eindhoven, Netherlands
| | - Dennis W J Klomp
- Division of Imaging and Oncology, University Medical Centre (UMC) Utrecht, Utrecht, Netherlands
| |
Collapse
|
3
|
Voskuilen L, Schoormans J, Gurney-Champion OJ, Balm AJM, Strijkers GJ, Smeele LE, Nederveen AJ. Dynamic MRI of swallowing: real-time volumetric imaging at 12 frames per second at 3 T. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2021; 35:411-419. [PMID: 34779971 PMCID: PMC9188511 DOI: 10.1007/s10334-021-00973-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 10/10/2021] [Accepted: 10/18/2021] [Indexed: 11/25/2022]
Abstract
Objective Dysphagia or difficulty in swallowing is a potentially hazardous clinical problem that needs regular monitoring. Real-time 2D MRI of swallowing is a promising radiation-free alternative to the current clinical standard: videofluoroscopy. However, aspiration may be missed if it occurs outside this single imaged slice. We therefore aimed to image swallowing in 3D real time at 12 frames per second (fps). Materials and methods At 3 T, three 3D real-time MRI acquisition approaches were compared to the 2D acquisition: an aligned stack-of-stars (SOS), and a rotated SOS with a golden-angle increment and with a tiny golden-angle increment. The optimal 3D acquisition was determined by computer simulations and phantom scans. Subsequently, five healthy volunteers were scanned and swallowing parameters were measured. Results Although the rotated SOS approaches resulted in better image quality in simulations, in practice, the aligned SOS performed best due to the limited number of slices. The four swallowing phases could be distinguished in 3D real-time MRI, even though the spatial blurring was stronger than in 2D. The swallowing parameters were similar between 2 and 3D. Conclusion At a spatial resolution of 2-by-2-by-6 mm with seven slices, swallowing can be imaged in 3D real time at a frame rate of 12 fps. Supplementary Information The online version contains supplementary material available at 10.1007/s10334-021-00973-6.
Collapse
Affiliation(s)
- Luuk Voskuilen
- Department of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni van Leeuwenhoek, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands. .,Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands. .,Academic Centre for Dentistry Amsterdam and Academic Medical Center, University of Amsterdam and VU University Amsterdam, Amsterdam, The Netherlands.
| | - Jasper Schoormans
- Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Oliver J Gurney-Champion
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| | - Alfons J M Balm
- Department of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni van Leeuwenhoek, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.,Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.,Robotics and Mechatronics, faculty of EEMCS, TechMed Center, University of Twente, Enschede, The Netherlands
| | - Gustav J Strijkers
- Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Ludi E Smeele
- Department of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Antoni van Leeuwenhoek, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.,Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Van der Cruyssen F, Croonenborghs TM, Renton T, Hermans R, Politis C, Jacobs R, Casselman J. Magnetic resonance neurography of the head and neck: state of the art, anatomy, pathology and future perspectives. Br J Radiol 2021; 94:20200798. [PMID: 33513024 PMCID: PMC8011265 DOI: 10.1259/bjr.20200798] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Magnetic resonance neurography allows for the selective visualization of peripheral nerves and is increasingly being investigated. Whereas in the past, the imaging of the extracranial cranial and occipital nerve branches was inadequate, more and more techniques are now available that do allow nerve imaging. This basic review provides an overview of the literature with current state of the art, anatomical landmarks and future perspectives. Furthermore, we illustrate the possibilities of the three-dimensional CRAnial Nerve Imaging (3D CRANI) MR-sequence by means of a few case studies.
Collapse
Affiliation(s)
- Fréderic Van der Cruyssen
- Department of Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Imaging and Pathology, OMFS-IMPATH Research Group, Faculty of Medicine, University Leuven, Leuven, Belgium
| | - Tomas-Marijn Croonenborghs
- Department of Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Imaging and Pathology, OMFS-IMPATH Research Group, Faculty of Medicine, University Leuven, Leuven, Belgium
| | - Tara Renton
- Department of Oral Surgery, King's College London Dental Institute, London, UK
| | - Robert Hermans
- Department of Radiology, University Hospitals Leuven, Leuven, Belgium
| | - Constantinus Politis
- Department of Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Imaging and Pathology, OMFS-IMPATH Research Group, Faculty of Medicine, University Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- Department of Imaging and Pathology, OMFS-IMPATH Research Group, Faculty of Medicine, University Leuven, Leuven, Belgium.,Department of Oral Health Sciences, KU Leuven and Department of Dentistry, University Hospitals Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Jan Casselman
- Department of Radiology, AZ St-Jan Brugge-Oostende, Bruges, Belgium.,Department of Radiology, AZ St-Augustinus, Antwerp, Belgium.,Department of Radiology, UZ Gent, Gent, Belgium
| |
Collapse
|