1
|
Wiest L, Baudot R, Lafay F, Bonjour E, Becouze-Lareure C, Aubin JB, Jame P, Barraud S, Kouyi GL, Sébastian C, Vulliet E. Priority substances in accumulated sediments in a stormwater detention basin from an industrial area. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2018; 243:1669-1678. [PMID: 30300872 DOI: 10.1016/j.envpol.2018.09.138] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 08/13/2018] [Accepted: 09/28/2018] [Indexed: 06/08/2023]
Abstract
One of the most adopted solutions in developed countries to manage stormwater is detention/retention basins which generate large quantities of sediments that have to be removed regularly. In order to manage them properly, accurate data are needed about their physical and chemical characteristics, particularly on micropollutant concentrations and their associated risk. This work consisted in a two-year sampling of dry sediments from a detention-settling basin. Priority substances, including pesticides, polybrominated diphenyl ethers (PBDE), alkylphenols and bisphenol A (BPA), were monitored. Different sites in the basin bottom were sampled in order to investigate spatial distribution of the contamination. Results show that the increase of the sediment thickness in the basin was heterogeneous with a maximum of 15 cm after two years. Pesticides and PBDE were, if detected, mainly found in low concentrations from 2 ng/g to 286 ng/g. Conversely, alkylphenols and bisphenol A were always quantified at concentrations varying from 6 ng/g to 3400 ng/g. These high levels suggest that these sediments should be managed with precautions. Spatial heterogeneity of alkylphenol ethoxylates and BPA concentrations was observed, with higher contamination of alkylphenol ethoxylates in anaerobic zones and BPA levels correlated with total organic carbon and in a lesser extent to fine particles.
Collapse
Affiliation(s)
- Laure Wiest
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, ENS de Lyon, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France.
| | - Robert Baudot
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, ENS de Lyon, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Florent Lafay
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, ENS de Lyon, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Erik Bonjour
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, ENS de Lyon, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | | | | | - Patrick Jame
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, ENS de Lyon, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Sylvie Barraud
- University of Lyon, INSA Lyon, DEEP, F-69621, Villeurbanne Cedex, France
| | | | - Christel Sébastian
- University of Lyon, INSA Lyon, DEEP, F-69621, Villeurbanne Cedex, France
| | - Emmanuelle Vulliet
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, ENS de Lyon, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| |
Collapse
|
2
|
Brits M, de Vos J, Weiss JM, Rohwer ER, de Boer J. Critical review of the analysis of brominated flame retardants and their environmental levels in Africa. CHEMOSPHERE 2016; 164:174-189. [PMID: 27591369 DOI: 10.1016/j.chemosphere.2016.08.097] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 08/15/2016] [Accepted: 08/21/2016] [Indexed: 06/06/2023]
Abstract
World-wide, the prevalence of brominated flame retardants (BFRs) is well documented for routine analysis of environmental and biological matrices. There is, however, limited information on these compounds in the African environment and insufficient information on the analytical approaches used to obtain data. This paper presents a review on BFR levels in the African environment and the various analytical methodologies specifically applied in Africa for polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls and alternative-BFRs. The analyses include liquid sample preparation using liquid-liquid and solid phase extraction and solid sample preparation involving Soxhlet extraction, with ultrasound-assisted extraction increasingly being applied. Instrumental detection techniques were limited to gas chromatography coupled with electron capture detector and electron impact ionisation with single quadrupole mass spectrometers. Information on congener profile prevalence in indoor dust, soil, aquatic environment (water, sediment, and aquatic organisms), eggs, wastewater treatment plant compartments, landfills (leachate and sediment) and breast milk are presented. Although PBDEs were inconsistently detected, contamination was reported for all investigated matrices in the African environment. The manifestation in remote regions indicates the ubiquitous prevalence and long-range transport of these compounds. Levels in sediment, and breast milk from some African countries were higher than reported for Asia and Europe. Due to limited data or non-detection of alternative-BFRs, it is unclear whether banned formulations were replaced in Africa. Most of the data reported for BFR levels in Africa were obtained in non-African laboratories or in South Africa and formed the basis for our discussion of reported contamination levels and related methodologies.
Collapse
Affiliation(s)
- Martin Brits
- National Metrology Institute of South Africa (NMISA), CSIR Campus, Meiring Naude Road, Pretoria, 0040, South Africa; VU University, Institute for Environmental Studies (IVM), De Boelelaan 1087, 1081 HV Amsterdam, The Netherlands; Laboratory for Separation Science, Department of Chemistry, Faculty of Natural and Agricultural Sciences, University of Pretoria, Lynnwood Road, Pretoria, 0002, South Africa.
| | - Jayne de Vos
- National Metrology Institute of South Africa (NMISA), CSIR Campus, Meiring Naude Road, Pretoria, 0040, South Africa
| | - Jana M Weiss
- Department of Environmental Science and Analytical Chemistry, Arrhenius Laboratory, Stockholm University, SE-10691, Stockholm, Sweden
| | - Egmont R Rohwer
- Laboratory for Separation Science, Department of Chemistry, Faculty of Natural and Agricultural Sciences, University of Pretoria, Lynnwood Road, Pretoria, 0002, South Africa
| | - Jacob de Boer
- VU University, Institute for Environmental Studies (IVM), De Boelelaan 1087, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
3
|
Use of fluorinated polybrominated diphenyl ethers and simplified cleanup for the analysis of polybrominated diphenyl ethers in house dust. J Chromatogr A 2014; 1356:266-71. [PMID: 25037776 DOI: 10.1016/j.chroma.2014.06.054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2014] [Revised: 05/16/2014] [Accepted: 06/16/2014] [Indexed: 11/21/2022]
Abstract
A simple, cost-effective method is described for the analysis of polybrominated diphenyl ethers (PBDEs) in house dust using pressurized fluid extraction, cleanup with modified silica solid phase extraction tubes, and fluorinated internal standards. There are 14 PBDE congeners included in the method, some typically contained in the commercial mixtures used as flame retardants, and some which are not routinely reported in the peer-reviewed literature. A gas chromatographic-mass spectrometry instrumental method provides baseline separation in <20 min, detection limits <20 ng/g, and quantitation limits <60 ng/g for most congeners. Method blanks contained an average concentration <9 ng/g for all congeners except BDE209 which had an average around 40 ng/g. Spiked samples showed good accuracy with relative percent difference (RPD) <7%, and good precision with relative standard deviation <22% for all congeners except BDE209. The method was applied to the analysis of a standard dust (NIST Standard Reference Material 2585) and showed good accuracy with RPD <25% except for BDE154. Overall, this method exhibited good performance characteristics in all categories including simplicity, cost, sensitivity, selectivity, accuracy, and precision.
Collapse
|
4
|
Kefeni KK, Okonkwo JO. Distribution of polybrominated diphenyl ethers and dust particle size fractions adherent to skin in indoor dust, Pretoria, South Africa. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2014; 21:4376-4386. [PMID: 24323323 DOI: 10.1007/s11356-013-2312-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Accepted: 10/29/2013] [Indexed: 06/03/2023]
Abstract
In order to determine human exposure to the indoor toxicant, selection of dust fraction and understanding dust particle size distribution in settled indoor dust are very important. This study examined the influence of dust particle size on the concentration of polybrominated diphenyl ethers (PBDEs) congeners, assessed the distribution of dust particle size and characterized the main indoor emission sources of PBDEs. Accordingly, the concentrations of PBDE congeners determined in different indoor dust fractions were found to be relatively higher in the order of dust particle size: 45-106 μm>(<45 μm)>106-150 μm. The finding shows arbitrary selection of dust fractions for exposure determination may result in wrong conclusions. Statistically significant moderate correlation between the concentration of Σ9PBDEs and organic matter content calculated with respect to the total dust mass was also observed (r=0.55, p=0.001). On average, of total dust particle size <250 μm, 93.4 % (m/m%) of dust fractions was associated with less than 150 μm. Furthermore, of skin adherent dust fractions considered (<150 μm), 86 % (v/v%) is in the range of particle size 9.25-104.7 μm. Electronic materials treated with PBDEs were found the main emission sources of PBDE congeners in indoor environment. Based on concentrations of PBDEs determined and mass of indoor dust observed, 150 μm metallic sieve is adequate for human exposure risk assessment. However, research in this area is very limited and more research is required to generalize the fact.
Collapse
Affiliation(s)
- Kebede Keterew Kefeni
- Environmental Chemistry Research Group, Department of Environmental, Water & Earth Sciences, Faculty of Science, Tshwane University of Technology, Private Bag X680, Pretoria, South Africa,
| | | |
Collapse
|
5
|
Zhang S, Zhao TB, Luo G, Huang H, Wang J, Cai ZZ. A Total Solution to Baseline Separation of 20 Brominated Flame Retardant Additives in Electronic Products with Automated Soxhlet Hot Extraction and Gas Chromatography-Mass Spectrometry. J CHIN CHEM SOC-TAIP 2012. [DOI: 10.1002/jccs.201100598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
6
|
Król S, Zabiegała B, Namieśnik J. Determination of polybrominated diphenyl ethers in house dust using standard addition method and gas chromatography with electron capture and mass spectrometric detection. J Chromatogr A 2012; 1249:201-14. [DOI: 10.1016/j.chroma.2012.06.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2012] [Revised: 05/29/2012] [Accepted: 06/01/2012] [Indexed: 11/25/2022]
|
7
|
Kefeni KK, Okonkwo JO. Analysis of major congeners of polybromobiphenyls and polybromodiphenyl ethers in office dust using high resolution gas chromatography-mass spectrometry. CHEMOSPHERE 2012; 87:1070-1075. [PMID: 22386464 DOI: 10.1016/j.chemosphere.2012.02.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2011] [Revised: 11/21/2011] [Accepted: 02/04/2012] [Indexed: 05/31/2023]
Abstract
The study focused on analysis of polybromobiphenyls (PBBs) and polybromodiphenyl ethers (PBDEs) congeners in office dust obtained in Pretoria, South Africa. Of the 32 congeners considered for identification, (BB-1, 2, 4, 10, 15, 26, 29, 30, 31, 38, 49, 80, 103, 153, 155, 209 and BDE-3, 15, 17, 28, 47, 66, 77, 85, 99, 100, 126, 138, 153, 154, 183, 209) only BB-2, 4, 30, 153, 209 and BDE-47, 66, 85, 99, 153 and 209 congeners were detected. The sum of PBBs concentration detected in office dust ranged from <dl-196 ng g(-1) dry weight (dw) with a median and mean of 11.4 and 38.2 ng g(-1), respectively. On the other hand, the sum of PBDEs concentration detected ranged from 21.6 to 578.6 ng g(-1)dw with a median and mean of 162 and 169 ng g(-1)dw, respectively. A Spearman rank correlation between ∑(5)PBBs and ∑(6)PBDEs (r(s)=0.55, p=0.003), indicated a statistical significant positive correlation for the similarity of pollution sources for both compound classes. However, no correlation was observed between the number of electronic materials and summation of concentrations of PBBs and PBDEs congeners detected. Concentrations of PBDEs detected in this study are substantially lower than reported in office dust in developed countries.
Collapse
Affiliation(s)
- Kebede K Kefeni
- Environmental Chemistry Research Group, Department of Environmental, Water and Earth Sciences, Faculty of Science, Tshwane University of Technology, Pretoria, South Africa.
| | | |
Collapse
|
8
|
PBDEs in environmental samples: Sampling and analysis. Talanta 2012; 93:1-17. [DOI: 10.1016/j.talanta.2012.01.048] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2011] [Revised: 01/17/2012] [Accepted: 01/29/2012] [Indexed: 11/19/2022]
|