1
|
Caridi GCA, Torta E, Mazzi V, Chiastra C, Audenino AL, Morbiducci U, Gallo D. Smartphone-based particle image velocimetry for cardiovascular flows applications: A focus on coronary arteries. Front Bioeng Biotechnol 2022; 10:1011806. [PMID: 36568311 PMCID: PMC9772456 DOI: 10.3389/fbioe.2022.1011806] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 11/24/2022] [Indexed: 12/13/2022] Open
Abstract
An experimental set-up is presented for the in vitro characterization of the fluid dynamics in personalized phantoms of healthy and stenosed coronary arteries. The proposed set-up was fine-tuned with the aim of obtaining a compact, flexible, low-cost test-bench for biomedical applications. Technically, velocity vector fields were measured adopting a so-called smart-PIV approach, consisting of a smartphone camera and a low-power continuous laser (30 mW). Experiments were conducted in realistic healthy and stenosed 3D-printed phantoms of left anterior descending coronary artery reconstructed from angiographic images. Time resolved image acquisition was made possible by the combination of the image acquisition frame rate of last generation commercial smartphones and the flow regimes characterizing coronary hemodynamics (velocities in the order of 10 cm/s). Different flow regimes (Reynolds numbers ranging from 20 to 200) were analyzed. The smart-PIV approach was able to provide both qualitative flow visualizations and quantitative results. A comparison between smart-PIV and conventional PIV (i.e., the gold-standard experimental technique for bioflows characterization) measurements showed a good agreement in the measured velocity vector fields for both the healthy and the stenosed coronary phantoms. Displacement errors and uncertainties, estimated by applying the particle disparity method, confirmed the soundness of the proposed smart-PIV approach, as their values fell within the same range for both smart and conventional PIV measured data (≈5% for the normalized estimated displacement error and below 1.2 pixels for displacement uncertainty). In conclusion, smart-PIV represents an easy-to-implement, low-cost methodology for obtaining an adequately robust experimental characterization of cardiovascular flows. The proposed approach, to be intended as a proof of concept, candidates to become an easy-to-handle test bench suitable for use also outside of research labs, e.g., for educational or industrial purposes, or as first-line investigation to direct and guide subsequent conventional PIV measurements.
Collapse
|
2
|
Impact of Malapposed and Overlapping Stents on Hemodynamics: A 2D Parametric Computational Fluid Dynamics Study. MATHEMATICS 2021. [DOI: 10.3390/math9080795] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Despite significant progress, malapposed or overlapped stents are a complication that affects daily percutaneous coronary intervention (PCI) procedures. These malapposed stents affect blood flow and create a micro re-circulatory environment. These disturbances are often associated with a change in Wall Shear Stress (WSS), Time-averaged WSS (TAWSS), relative residence time (RRT) and oscillatory character of WSS and disrupt the delicate balance of vascular biology, providing a possible source of thrombosis and restenosis. In this study, 2D axisymmetric parametric computational fluid dynamics (CFD) simulations were performed to systematically analyze the hemodynamic effects of malapposition and stent overlap for two types of stents (drug-eluting stent and a bioresorbable stent). The results of the modeling are mainly analyzed using streamlines, TAWSS, oscillatory shear index (OSI) and RRT. The risks of restenosis and thrombus are evaluated according to commonly accepted thresholds for TAWSS and OSI. The small malapposition distances (MD) cause both low TAWSS and high OSI, which are potential adverse outcomes. The region of low OSI decrease with MD. Overlap configurations produce areas with low WSS and high OSI. The affected lengths are relatively insensitive to the overlap distance. The effects of strut size are even more sensitive and adverse for overlap configurations compared to a well-applied stent.
Collapse
|
3
|
Sharzehee M, Seddighi Y, Sprague EA, Finol EA, Han HC. A Hemodynamic Comparison of Myocardial Bridging and Coronary Atherosclerotic Stenosis: A Computational Model With Experimental Evaluation. J Biomech Eng 2021; 143:031013. [PMID: 33269788 DOI: 10.1115/1.4049221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Indexed: 11/08/2022]
Abstract
Myocardial bridging (MB) and coronary atherosclerotic stenosis can impair coronary blood flow and may cause myocardial ischemia or even heart attack. It remains unclear how MB and stenosis are similar or different regarding their impacts on coronary hemodynamics. The purpose of this study was to compare the hemodynamic effects of coronary stenosis and MB using experimental and computational fluid dynamics (CFD) approaches. For CFD modeling, three MB patients with different levels of lumen obstruction, mild, moderate, and severe were selected. Patient-specific left anterior descending (LAD) coronary artery models were reconstructed from biplane angiograms. For each MB patient, the virtually healthy and stenotic models were also simulated for comparison. In addition, an in vitro flow-loop was developed, and the pressure drop was measured for comparison. The CFD simulations results demonstrated that the difference between MB and stenosis increased with increasing MB/stenosis severity and flowrate. Experimental results showed that increasing the MB length (by 140%) only had significant impact on the pressure drop in the severe MB (39% increase at the exercise), but increasing the stenosis length dramatically increased the pressure drop in both moderate and severe stenoses at all flow rates (31% and 93% increase at the exercise, respectively). Both CFD and experimental results confirmed that the MB had a higher maximum and a lower mean pressure drop in comparison with the stenosis, regardless of the degree of lumen obstruction. A better understanding of MB and atherosclerotic stenosis may improve the therapeutic strategies in coronary disease patients and prevent acute coronary syndromes.
Collapse
Affiliation(s)
- Mohammadali Sharzehee
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249
| | - Yasamin Seddighi
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249
| | - Eugene A Sprague
- Department of Medicine, University of Texas Health San Antonio, San Antonio, TX 78229
| | - Ender A Finol
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249
| | - Hai-Chao Han
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249
| |
Collapse
|
4
|
Sharzehee M, Chang Y, Song JP, Han HC. Hemodynamic effects of myocardial bridging in patients with hypertrophic cardiomyopathy. Am J Physiol Heart Circ Physiol 2019; 317:H1282-H1291. [PMID: 31674812 DOI: 10.1152/ajpheart.00466.2019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Myocardial bridging (MB) is linked to angina and myocardial ischemia and may lead to sudden cardiac death in patients with hypertrophic cardiomyopathy (HCM). However, it remains unclear how MB affect the coronary blood flow in HCM patients. The aim of this study was to assess the effects of MB on coronary hemodynamics in HCM patients. Fifteen patients with MB (7 HCM and 8 non-HCM controls) in their left anterior descending (LAD) coronary artery were chosen. Transient computational fluid dynamics (CFD) simulations were conducted in anatomically realistic models of diseased (with MB) and virtually healthy (without MB) LAD from these patients, reconstructed from biplane angiograms. Our CFD simulation results demonstrated that dynamic compression of MB led to diastolic flow disturbances and could significantly reduce the coronary flow in HCM patients as compared with non-HCM group (P < 0.01). The pressure drop coefficient was remarkably higher (P < 0.05) in HCM patients. The flow rate change is strongly correlated with both upstream Reynolds number and MB compression ratio, while the MB length has less impact on coronary flow. The hemodynamic results and clinical outcomes revealed that HCM patients with an MB compression ratio higher than 65% required a surgical intervention. In conclusion, the transient MB compression can significantly alter the diastolic flow pattern and wall shear stress distribution in HCM patients. HCM patients with severe MB may need a surgical intervention.NEW & NOTEWORTHY In this study, the hemodynamic significance of myocardial bridging (MB) in patients with hypertrophic cardiomyopathy (HCM) was investigated to provide valuable information for surgical decision-making. Our results illustrated that the transient MB compression led to complex flow patterns, which can significantly alter the diastolic flow and wall shear stress distribution. The hemodynamic results and clinical outcomes demonstrated that patients with HCM and an MB compression ratio higher than 65% required a surgical intervention.
Collapse
Affiliation(s)
- Mohammadali Sharzehee
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, Texas
| | - Yuan Chang
- Department of Cardiac Surgery, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Beijing, China
| | - Jiang-Ping Song
- Department of Cardiac Surgery, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Beijing, China
| | - Hai-Chao Han
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, Texas
| |
Collapse
|
5
|
The Time-Domain Integration Method of Digital Subtraction Angiography Images. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2018; 2018:5284969. [PMID: 30363945 PMCID: PMC6186332 DOI: 10.1155/2018/5284969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 08/28/2018] [Indexed: 11/17/2022]
Abstract
The clarity improvement and the noise suppression of digital subtraction angiography (DSA) images are very important. However, the common methods are very complicated. An image time-domain integration method is proposed in this study, which is based on the blood flow periodicity. In this method, the images of the first cardiac cycle after the injection of the contrast agent are integrated to obtain the time-domain integration image. This method can be used independently or as a postprocessing method of the denoising method on the signal image. The experimental results on DSA data from an aortic dissection patient show that the image time-domain integration method is efficient in image denoising and enhancement, which also has a good real-time performance. This method can also be used to improve the denoising and image enhancement effect of some common models.
Collapse
|
6
|
Wang J, Jin X, Huang Y, Ran X, Luo D, Yang D, Jia D, Zhang K, Tong J, Deng X, Wang G. Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis. Regen Biomater 2018; 5:177-187. [PMID: 29942650 PMCID: PMC6007795 DOI: 10.1093/rb/rby006] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Revised: 02/11/2018] [Accepted: 03/08/2018] [Indexed: 02/06/2023] Open
Abstract
Cardiovascular stent restenosis remains a major challenge in interventional treatment of cardiovascular occlusive disease. Although the changes in arterial mechanical environment due to stent implantation are the main causes of the initiation of restenosis and thrombosis, the mechanisms that cause this initiation are still not fully understood. In this article, we reviewed the studies on the issue of stent-induced alterations in arterial mechanical environment and discussed their roles in stent restenosis and late thrombosis from three aspects: (i) the interaction of the stent with host blood vessel, involve the response of vascular wall, the mechanism of mechanical signal transmission, the process of re-endothelialization and late thrombosis; (ii) the changes of hemodynamics in the lumen of the vascular segment and (iii) the changes of mechanical microenvironment within the vascular segment wall due to stent implantation. This review has summarized and analyzed current work in order to better solve the two main problems after stent implantation, namely in stent restenosis and late thrombosis, meanwhile propose the deficiencies of current work for future reference.
Collapse
Affiliation(s)
- Jinxuan Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Xuepu Jin
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Yuhua Huang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Xiaolin Ran
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Desha Luo
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Dongchuan Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Dongyu Jia
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Kang Zhang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| | - Jianhua Tong
- Institute for Biomedical Engineering & Nano Science, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
| | - Xiaoyan Deng
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Guixue Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education; State and Local Joint Engineering Laboratory for Vascular Implants; Bioengineering College of Chongqing University, Chongqing, China
| |
Collapse
|
7
|
Sun W, Huang Y, Yin T, Wang J, Du R, Qiu J, Zhang Y, Wang Y, Chen J, Wang G. Effects of elemene on inhibiting proliferation of vascular smooth muscle cells and promoting reendothelialization at the stent implantation site. Biomater Sci 2017; 5:1144-1155. [DOI: 10.1039/c7bm00190h] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Elemene coated stents prepared by electrospray could inhibit proliferation of VSMCs and promote endothelialization after implantation into rabbit iliac arteries.
Collapse
|
8
|
Brindise MC, Chiastra C, Burzotta F, Migliavacca F, Vlachos PP. Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: An In Vitro Study. Ann Biomed Eng 2016; 45:542-553. [PMID: 27460012 DOI: 10.1007/s10439-016-1699-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2016] [Accepted: 07/19/2016] [Indexed: 01/09/2023]
Abstract
Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions were investigated experimentally. Three implantation methods, provisional side branch (PSB), culotte (CUL), and crush (CRU), were investigated using time-resolved particle image velocimetry to measure the velocity fields. Subsequently, hemodynamic parameters including wall shear stress, oscillatory shear index (OSI), and relative residence time (RRT) were calculated. The pressure field through the vessel was non-invasively quantified and pressure wave speeds were computed. The effects of each stented case were evaluated and compared against an un-stented case. CRU provided the lowest compliance mismatch, but demonstrated detrimental stent interactions. PSB, the clinically preferred method, and CUL maintained many normal flow conditions. However, PSB provided about a 300% increase in both OSI and RRT. CUL yielded a 10 and 85% increase in OSI and RRT, respectively. The results of this study support the concept that different bifurcation stenting techniques result in hemodynamic environments that deviate from that of un-stented bifurcations, to varying degrees.
Collapse
Affiliation(s)
- Melissa C Brindise
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Claudio Chiastra
- Laboratory of Biological Structure Mechanics (LaBS), Chemistry, Materials and Chemical Engineering Department "Giulio Natta", Politecnico di Milano, Milan, Italy
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands
| | - Francesco Burzotta
- Department of Cardiovascular Medicine, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Chemistry, Materials and Chemical Engineering Department "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Pavlos P Vlachos
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA.
| |
Collapse
|
9
|
Raben JS, Hariharan P, Robinson R, Malinauskas R, Vlachos PP. Time-Resolved Particle Image Velocimetry Measurements with Wall Shear Stress and Uncertainty Quantification for the FDA Nozzle Model. Cardiovasc Eng Technol 2015; 7:7-22. [DOI: 10.1007/s13239-015-0251-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Accepted: 11/23/2015] [Indexed: 10/22/2022]
|
10
|
Local blood flow patterns in stented coronary bifurcations: an experimental and numerical study. J Appl Biomater Funct Mater 2015; 13:e116-26. [PMID: 25589159 DOI: 10.5301/jabfm.5000217] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/17/2014] [Indexed: 11/20/2022] Open
Abstract
PURPOSE Despite the atheroprone environment of blood flow in coronary bifurcations, limited quantitative information is available on the hemodynamics occurring in these geometries, both before and after their treatment with endovascular stents. Previous studies have focused on computational fluid dynamics (CFD) analyses and have bypassed the challenges associated with experimentally representing the flow environment, providing no means for validation. This study analyzed steady flow conditions in 3 bifurcation angles and 4 different single- and double-stenting procedures, which are used clinically in coronary bifurcations. METHODS The numerical aspect of this study utilized geometries derived from CAD models (nonstented cases) and finite element simulations (stented cases). Digital particle image velocimetry (DPIV) testing was conducted within compliant bifurcating models for which an uncertainty analysis was performed at each measurement location for CFD validation purposes. Results were analyzed in terms of velocity magnitude contour maps and axial velocity profiles at several locations in the bifurcated vessels. RESULTS AND CONCLUSIONS Qualitatively, the 2 approaches showed agreement in the bulk flow patterns. However, the velocity computed with CFD was outside the DPIV uncertainty estimates, which can be attributed to the intrinsic difference and modeling assumptions of the 2 approaches. The findings reveal that wider bifurcation angles and double-stenting procedures are both characterized by increased areas of low flow and recirculation. Additionally, inferior performance in terms of viscous and wall shear stresses was observed in double-stented cases.
Collapse
|
11
|
Selvarasu NKC, Tafti DK. Effects of elastic modulus change in helical tubes under the influence of dynamic changes in curvature and torsion. J Biomech Eng 2015; 136:1873134. [PMID: 24886746 DOI: 10.1115/1.4027661] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2013] [Accepted: 05/14/2014] [Indexed: 11/08/2022]
Abstract
The incidence of stent late restenosis is high (Zwart et al., 2010, "Coronary Stent Thrombosis in the Current Era: Challenges and Opportunities for Treatment," Curr. Treat. Options Cardiovasc. Med., 12(1), pp. 46-57) despite the extensive use of stents, and is most prevalent at the proximal and distal ends of the stent. Elastic modulus change in stented coronary arteries subject to the motion of the myocardium is not studied extensively. It is our objective to understand and reveal the mechanism by which changes in elastic modulus and geometry contribute to the generation of nonphysiological wall shear stress (WSS). Such adverse hemodynamic conditions could have an effect on the onset of restenosis. Three-dimensional (3D), spatiotemporally resolved computational fluid dynamics (CFD) simulations of pulsatile flow with moving wall boundaries and fluid structure interaction (FSI) were carried out for a helical artery with physiologically relevant flow parameters. To study the effect of coronary artery (CA) geometry change on stent elastic modulus mismatch, models where the curvature, torsion and both curvature and torsion change were examined. The elastic modulus is increased by a factor of two, five, and ten in the stented section for all three modes of motion. The changes in elastic modulus and arterial geometry cause critical variations in the local pressure and velocity gradients and secondary flow patterns. The pressure gradient change is 47%, with respect to the unstented baseline when the elastic modulus is increased to 10. The corresponding WSS change is 15.4%. We demonstrate that these changes are attributed to the production of vorticity (vorticity flux) caused by the wall movement and elastic modulus discontinuity. The changes in curvature dominate torsion changes in terms of the effects to local hemodynamics. The elastic modulus discontinuities along with the dynamic change in geometry affected the secondary flow patterns and vorticity flux, which in turn affects the WSS.
Collapse
|
12
|
Kolandaivelu K, Leiden BB, Edelman ER. Predicting response to endovascular therapies: Dissecting the roles of local lesion complexity, systemic comorbidity, and clinical uncertainty. J Biomech 2014; 47:908-21. [DOI: 10.1016/j.jbiomech.2014.01.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 11/25/2022]
|
13
|
Rikhtegar F, Wyss C, Stok KS, Poulikakos D, Müller R, Kurtcuoglu V. Hemodynamics in coronary arteries with overlapping stents. J Biomech 2014; 47:505-11. [DOI: 10.1016/j.jbiomech.2013.10.048] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Revised: 09/17/2013] [Accepted: 10/26/2013] [Indexed: 01/20/2023]
|
14
|
Results of FDA’s First Interlaboratory Computational Study of a Nozzle with a Sudden Contraction and Conical Diffuser. Cardiovasc Eng Technol 2013. [DOI: 10.1007/s13239-013-0166-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
15
|
Koskinas KC, Chatzizisis YS, Antoniadis AP, Giannoglou GD. Role of endothelial shear stress in stent restenosis and thrombosis: pathophysiologic mechanisms and implications for clinical translation. J Am Coll Cardiol 2012; 59:1337-49. [PMID: 22480478 DOI: 10.1016/j.jacc.2011.10.903] [Citation(s) in RCA: 220] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2011] [Revised: 09/13/2011] [Accepted: 10/27/2011] [Indexed: 10/28/2022]
Abstract
Restenosis and thrombosis are potentially fatal complications of coronary stenting with a recognized multifactorial etiology. The effect of documented risk factors, however, cannot explain the preponderance of certain lesion types, stent designs, and implantation configurations for the development of these complications. Local hemodynamic factors, low endothelial shear stress (ESS) in particular, are long known to critically affect the natural history of atherosclerosis. Increasing evidence now suggests that ESS may also contribute to the development of restenosis and thrombosis upon stenting of atherosclerotic plaques, in conjunction with well-appreciated risk factors. In this review, we present in vivo and mechanistic evidence associating ESS with the localization and progression of neointimal hyperplasia and in-stent clotting. Clinical studies have associated stent design features with the risk of restenosis. Importantly, computational simulations extend these observations by directly linking specific stent geometry and positioning characteristics with the post-stenting hemodynamic milieu and with the stent's thrombogenicity and pro-restenotic potential, thereby indicating ways to clinical translation. An enhanced understanding of the pathophysiologic role of ESS in restenosis and thrombosis might dictate hemodynamically favorable stent designs and deployment configurations to reduce the potential for late lumen loss and thrombotic obstruction. Recent methodologies for in vivo ESS profiling at a clinical level might allow for early identification of patients at high risk for the development of restenosis or thrombosis and might thereby guide individualized, risk-tailored treatment strategies to prevent devastating complications of endovascular interventions.
Collapse
Affiliation(s)
- Konstantinos C Koskinas
- 1st Cardiology Department, AHEPA University Hospital, Aristole University Medical School, Thessaloniki, Greece
| | | | | | | |
Collapse
|
16
|
Papafaklis MI, Chatzizisis YS, Naka KK, Giannoglou GD, Michalis LK. Drug-eluting stent restenosis: effect of drug type, release kinetics, hemodynamics and coating strategy. Pharmacol Ther 2011; 134:43-53. [PMID: 22212618 DOI: 10.1016/j.pharmthera.2011.12.006] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2011] [Accepted: 12/07/2011] [Indexed: 11/26/2022]
Abstract
Restenosis following stent implantation diminishes the procedure's efficacy influencing long-term clinical outcomes. Stent-based drug delivery emerged a decade ago as an effective means of reducing neointimal hyperplasia by providing localized pharmacotherapy during the acute phase of the stent-induced injury and the ensuing pathobiological mechanisms. However, drug-eluting stent (DES) restenosis may still occur especially when stents are used in complex anatomical and clinical scenarios. A DES consists of an intravascular metallic frame and carriers which allow controlled release of active pharmaceutical agents; all these components are critical in determining drug distribution locally and thus anti-restenotic efficacy. Furthermore, dynamic flow phenomena characterizing the vascular environment, and shear stress distribution, are greatly influenced by stent implantation and play a significant role in drug deposition and bioavailability within local vascular tissue. In this review, we discuss the performance of DES and the interaction of the different DES components with the hemodynamic milieu emphasizing on the inhibition of clinical restenosis.
Collapse
Affiliation(s)
- Michail I Papafaklis
- Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02120, USA.
| | | | | | | | | |
Collapse
|
17
|
Selvarasu NKC, Tafti DK, Vlachos PP. Hydrodynamic effects of compliance mismatch in stented arteries. J Biomech Eng 2011; 133:021008. [PMID: 21280880 DOI: 10.1115/1.4003319] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cardiovascular diseases are the number one cause of death in the world, making the understanding of hemodynamics and development of treatment options imperative. The most common modality for treatment of occlusive coronary artery diseases is the use of stents. Stent design profoundly influences the postprocedural hemodynamic and solid mechanical environment of the stented artery. However, despite their wide acceptance, the incidence of stent late restenosis is still high (Zwart et al., 2010, "Coronary Stent Thrombosis in the Current Era: Challenges and Opportunities for Treatment," Current Treatment Options in Cardiovascular Medicine, 12(1), pp. 46-57), and it is most prevailing at the proximal and distal ends of the stent. In this work, we focus our investigation on the localized hemodynamic effects of compliance mismatch due to the presence of a stent in an artery. The compliance mismatch in a stented artery is maximized at the proximal and distal ends of the stent. Hence, it is our objective to understand and reveal the mechanism by which changes in compliance contribute to the generation of nonphysiological wall shear stress (WSS). Such adverse hemodynamic conditions could have an effect on the onset of restenosis. Three-dimensional, spatiotemporally resolved computational fluid dynamics simulations of pulsatile flow with fluid-structure interaction were carried out for a simplified coronary artery with physiologically relevant flow parameters. A model with uniform elastic modulus is used as the baseline control case. In order to study the effect of compliance variation on local hemodynamics, this baseline model is compared with models where the elastic modulus was increased by two-, five-, and tenfold in the middle of the vessel. The simulations provided detailed information regarding the recirculation zone dynamics formed during flow reversals. The results suggest that discontinuities in compliance cause critical changes in local hemodynamics, namely, altering the local pressure and velocity gradients. The change in pressure gradient at the discontinuity was as high as 90%. The corresponding changes in WSS and oscillatory shear index calculated were 9% and 15%, respectively. We demonstrate that these changes are attributed to the physical mechanism associating the pressure gradient discontinuities to the production of vorticity (vorticity flux) due to the presence of the stent. The pressure gradient discontinuities and augmented vorticity flux are affecting the wall shear stresses. As a result, this work reveals how compliance variations act to modify the near wall hemodynamics of stented arteries.
Collapse
Affiliation(s)
- N K C Selvarasu
- Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, 114-I Randolph Hall, Mail Code 0238, Blacksburg, VA 24061, USA
| | | | | |
Collapse
|