1
|
Skoric J, D’Mello Y, Plant DV. A Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2024; 12:348-358. [PMID: 38606390 PMCID: PMC11008810 DOI: 10.1109/jtehm.2024.3368291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 02/09/2024] [Accepted: 02/19/2024] [Indexed: 04/13/2024]
Abstract
Wearable sensing has become a vital approach to cardiac health monitoring, and seismocardiography (SCG) is emerging as a promising technology in this field. However, the applicability of SCG is hindered by motion artifacts, including those encountered in practice of which the strongest source is walking. This holds back the translation of SCG to clinical settings. We therefore investigated techniques to enhance the quality of SCG signals in the presence of motion artifacts. To simulate ambulant recordings, we corrupted a clean SCG dataset with real-walking-vibrational noise. We decomposed the signal using several empirical-mode-decomposition methods and the maximum overlap discrete wavelet transform (MODWT). By combining MODWT, time-frequency masking, and nonnegative matrix factorization, we developed a novel algorithm which leveraged the vertical axis accelerometer to reduce walking vibrations in dorsoventral SCG. The accuracy and applicability of our method was verified using heart rate estimation. We used an interactive selection approach to improve estimation accuracy. The best decomposition method for reduction of motion artifact noise was the MODWT. Our algorithm improved heart rate estimation from 0.1 to 0.8 r-squared at -15 dB signal-to-noise ratio (SNR). Our method reduces motion artifacts in SCG signals up to a SNR of -19 dB without requiring any external assistance from electrocardiography (ECG). Such a standalone solution is directly applicable to the usage of SCG in daily life, as a content-rich replacement for other wearables in clinical settings, and other continuous monitoring scenarios. In applications with higher noise levels, ECG may be incorporated to further enhance SCG and extend its usable range. This work addresses the challenges posed by motion artifacts, enabling SCG to offer reliable cardiovascular insights in more difficult scenarios, and thereby facilitating wearable monitoring in daily life and the clinic.
Collapse
Affiliation(s)
- James Skoric
- Department of Electrical and Computer EngineeringMcGill UniversityMontrealQCH3A 0E9Canada
| | - Yannick D’Mello
- Department of Electrical and Computer EngineeringMcGill UniversityMontrealQCH3A 0E9Canada
| | - David V. Plant
- Department of Electrical and Computer EngineeringMcGill UniversityMontrealQCH3A 0E9Canada
| |
Collapse
|
2
|
Ebrahimkhani M, Johnson EMI, Sodhi A, Robinson JD, Rigsby CK, Allen BD, Markl M. A Deep Learning Approach to Using Wearable Seismocardiography (SCG) for Diagnosing Aortic Valve Stenosis and Predicting Aortic Hemodynamics Obtained by 4D Flow MRI. Ann Biomed Eng 2023; 51:2802-2811. [PMID: 37573264 DOI: 10.1007/s10439-023-03342-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 07/27/2023] [Indexed: 08/14/2023]
Abstract
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.
Collapse
Affiliation(s)
- Mahmoud Ebrahimkhani
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Ethan M I Johnson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Aparna Sodhi
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
| | - Joshua D Robinson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Cynthia K Rigsby
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Bradly D Allen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA.
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
3
|
Santucci F, Nobili M, Presti DL, Massaroni C, Setola R, Schena E, Oliva G. Waveform Similarity Analysis Using Graph Mining for the Optimization of Sensor Positioning in Wearable Seismocardiography. IEEE Trans Biomed Eng 2023; 70:2788-2798. [PMID: 37027279 DOI: 10.1109/tbme.2023.3264940] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
OBJECTIVE A major concern with wearable devices aiming to measure the seismocardiogram (SCG) signal is the variability of SCG waveform with the sensor position and a lack of a standard measurement procedure. We propose a method to optimize sensor positioning based on the similarity among waveforms collected through repeated measurements. METHOD we design a graph-theoretical model to evaluate the similarity of SCG signals and apply the proposed methodology to signals collected by sensors placed in different positions on the chest. A similarity score returns the optimal measurement position based on the repeatability of SCG waveforms. We tested the methodology on signals collected by using two wearable patches based on optical technology placed in two positions: mitral and aortic valve auscultation site (inter-position analysis). 11 healthy subjects were enrolled in this study. Moreover, we evaluated the influence of the subject's posture on waveform similarity with a view on ambulatory use (inter-posture analysis). RESULTS the highest similarity among SCG waveforms is obtained with the sensor on the mitral valve and the subject lying down. CONCLUSIONS our approach aims to be a step forward in the optimization of sensor positioning in the field of wearable seismocardiography. We demonstrate that the proposed algorithm is an effective method to estimate similarity among waveforms and outperforms the state-of-the-art in comparing SCG measurement sites. SIGNIFICANCE results obtained from this study can be exploited to design more efficient protocols for SCG recording in both research studies and future clinical examinations.
Collapse
|
4
|
Santucci F, Lo Presti D, Massaroni C, Schena E, Setola R. Precordial Vibrations: A Review of Wearable Systems, Signal Processing Techniques, and Main Applications. SENSORS 2022; 22:s22155805. [PMID: 35957358 PMCID: PMC9370957 DOI: 10.3390/s22155805] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/21/2022] [Accepted: 07/28/2022] [Indexed: 02/06/2023]
Abstract
Recently, the ever-growing interest in the continuous monitoring of heart function in out-of-laboratory settings for an early diagnosis of cardiovascular diseases has led to the investigation of innovative methods for cardiac monitoring. Among others, wearables recording seismic waves induced on the chest surface by the mechanical activity of the heart are becoming popular. For what concerns wearable-based methods, cardiac vibrations can be recorded from the thorax in the form of acceleration, angular velocity, and/or displacement by means of accelerometers, gyroscopes, and fiber optic sensors, respectively. The present paper reviews the currently available wearables for measuring precordial vibrations. The focus is on sensor technology and signal processing techniques for the extraction of the parameters of interest. Lastly, the explored application scenarios and experimental protocols with the relative influencing factors are discussed for each technique. The goal is to delve into these three fundamental aspects (i.e., wearable system, signal processing, and application scenario), which are mutually interrelated, to give a holistic view of the whole process, beyond the sensor aspect alone. The reader can gain a more complete picture of this context without disregarding any of these 3 aspects.
Collapse
Affiliation(s)
- Francesca Santucci
- Unit of Automatic Control, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy;
- Correspondence: ; Tel.: +39-062-2541-9603
| | - Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy; (D.L.P.); (C.M.); (E.S.)
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy; (D.L.P.); (C.M.); (E.S.)
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy; (D.L.P.); (C.M.); (E.S.)
| | - Roberto Setola
- Unit of Automatic Control, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy;
| |
Collapse
|
5
|
Montero-Cruces L, Carnero-Alcázar M, Reguillo-Lacruz FJ, Cobiella-Carnicer FJ, Pérez-Camargo D, Campelos-Fernández P, Maroto-Castellanos LC. One-Year Hemodynamic Performance of Three Cardiac Aortic Bioprostheses: A Randomized Comparative Clinical Trial. J Clin Med 2021; 10:jcm10225340. [PMID: 34830622 PMCID: PMC8625181 DOI: 10.3390/jcm10225340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/08/2021] [Accepted: 11/15/2021] [Indexed: 11/16/2022] Open
Abstract
Background: We aimed to compare 1 year the hemodynamic in-vivo performance of three biological aortic prostheses (Carpentier Perimount Magna EaseTM, Crown PRTTM, and TrifectaTM). Methods: The sample used in this study comes from the “BEST-VALVE” clinical trial, which is a phase IV single-blinded randomized clinical trial with the three above-mentioned prostheses. Results: 154 patients were included. Carpentier Perimount Magna EaseTM (n = 48, 31.2%), Crown PRTTM (n = 51, 32.1%) and TrifectaTM (n = 55, 35.7%). One year after the surgery, the mean aortic gradient and the peak aortic velocity was 17.5 (IQR 11.3–26) and 227.1 (IQR 202.0–268.8) for Carpentier Perimount Magna EaseTM, 21.4 (IQR 14.5–26.7) and 237.8 (IQR 195.9–261.9) for Crown PRTTM, and 13 (IQR 9.6–17.8) and 209.7 (IQR 176.5–241.4) for TrifectaTM, respectively. Pairwise comparisons demonstrated improved mean gradients and maximum velocity of TrifectaTM as compared to Crown PRTTM. Among patients with nominal prosthesis sizes ≤ 21, the mean and peak aortic gradient was higher for Crown PRTTM compared with TrifectaTM, and in patients with an aortic annulus measured with metric Hegar dilators less than or equal to 22 mm. Conclusions: One year after surgery, the three prostheses presented a different hemodynamic performance, being TrifectaTM superior to Crown PRTTM.
Collapse
|
6
|
Lo Presti D, Santucci F, Massaroni C, Formica D, Setola R, Schena E. A multi-point heart rate monitoring using a soft wearable system based on fiber optic technology. Sci Rep 2021; 11:21162. [PMID: 34707131 PMCID: PMC8551187 DOI: 10.1038/s41598-021-00574-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 10/06/2021] [Indexed: 12/14/2022] Open
Abstract
Early diagnosis can be crucial to limit both the mortality and economic burden of cardiovascular diseases. Recent developments have focused on the continuous monitoring of cardiac activity for a prompt diagnosis. Nowadays, wearable devices are gaining broad interest for a continuous monitoring of the heart rate (HR). One of the most promising methods to estimate HR is the seismocardiography (SCG) which allows to record the thoracic vibrations with high non-invasiveness in out-of-laboratory settings. Despite significant progress on SCG, the current state-of-the-art lacks both information on standardized sensor positioning and optimization of wearables design. Here, we introduce a soft wearable system (SWS), whose novel design, based on a soft polymer matrix embedding an array of fiber Bragg gratings, provides a good adhesion to the body and enables the simultaneous recording of SCG signals from multiple measuring sites. The feasibility assessment on healthy volunteers revealed that the SWS is a suitable wearable solution for HR monitoring and its performance in HR estimation is strongly influenced by sensor positioning and improved by a multi-sensor configuration. These promising characteristics open the possibility of using the SWS in monitoring patients with cardiac pathologies in clinical (e.g., during cardiac magnetic resonance procedures) and everyday life settings.
Collapse
Affiliation(s)
- Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Francesca Santucci
- Departmental Faculty of Engineering, Unit of Automatic Control, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Domenico Formica
- Unit of NEXT, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Roberto Setola
- Departmental Faculty of Engineering, Unit of Automatic Control, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy.
| |
Collapse
|
7
|
Miniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants. Proc Natl Acad Sci U S A 2021; 118:2104925118. [PMID: 34663725 PMCID: PMC8639372 DOI: 10.1073/pnas.2104925118] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2021] [Indexed: 01/18/2023] Open
Abstract
Early detection of infant neuromotor pathologies is critical for timely therapeutic interventions that rely on early-life neuroplasticity. Traditional assessments rely on subjective expert evaluations or specialized medical facilities, making them challenging to scale in remote and/or resource-constrained settings. The results presented here aim to democratize these evaluations using wireless networks of miniaturized, skin-integrated sensors that digitize movement behaviors and vital signs of infants in a cost-effective manner. The resulting data yield full-body motion reconstructions in the form of deidentified infant avatars, along with a range of important cardiopulmonary information. This technology approach enables rapid, routine evaluations of infants at any age via an engineering platform that has potential for use in nearly any setting across developed and developing countries alike. Early identification of atypical infant movement behaviors consistent with underlying neuromotor pathologies can expedite timely enrollment in therapeutic interventions that exploit inherent neuroplasticity to promote recovery. Traditional neuromotor assessments rely on qualitative evaluations performed by specially trained personnel, mostly available in tertiary medical centers or specialized facilities. Such approaches are high in cost, require geographic proximity to advanced healthcare resources, and yield mostly qualitative insight. This paper introduces a simple, low-cost alternative in the form of a technology customized for quantitatively capturing continuous, full-body kinematics of infants during free living conditions at home or in clinical settings while simultaneously recording essential vital signs data. The system consists of a wireless network of small, flexible inertial sensors placed at strategic locations across the body and operated in a wide-bandwidth and time-synchronized fashion. The data serve as the basis for reconstructing three-dimensional motions in avatar form without the need for video recordings and associated privacy concerns, for remote visual assessments by experts. These quantitative measurements can also be presented in graphical format and analyzed with machine-learning techniques, with potential to automate and systematize traditional motor assessments. Clinical implementations with infants at low and at elevated risks for atypical neuromotor development illustrates application of this system in quantitative and semiquantitative assessments of patterns of gross motor skills, along with body temperature, heart rate, and respiratory rate, from long-term and follow-up measurements over a 3-mo period following birth. The engineering aspects are compatible for scaled deployment, with the potential to improve health outcomes for children worldwide via early, pragmatic detection methods.
Collapse
|
8
|
The Latest Progress and Development Trend in the Research of Ballistocardiography (BCG) and Seismocardiogram (SCG) in the Field of Health Care. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11198896] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The current status of the research of Ballistocardiography (BCG) and Seismocardiogram (SCG) in the field of medical treatment, health care and nursing was analyzed systematically, and the important direction in the research was explored, to provide reference for the relevant researches. This study, based on two large databases, CNKI and PubMed, used the bibliometric analysis method to review the existing documents in the past 20 years, and made analyses on the literature of BCG and SCG for their annual changes, main countries/regions, types of research, frequently-used subject words, and important research subjects. The results show that the developed countries have taken a leading position in the researches in this field, and have made breakthroughs in some subjects, but their research results have been mainly gained in the area of research and development of the technologies, and very few have been actually industrialized into commodities. This means that in the future the researchers should focus on the transformation of BCG and SCG technologies into commercialized products, and set up quantitative health assessment models, so as to become the daily tools for people to monitor their health status and manage their own health, and as the main approaches of improving the quality of life and preventing diseases for individuals.
Collapse
|
9
|
A Comprehensive Review on Seismocardiogram: Current Advancements on Acquisition, Annotation, and Applications. MATHEMATICS 2021. [DOI: 10.3390/math9182243] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In recent years, cardiovascular diseases are on the rise, and they entail enormous health burdens on global economies. Cardiac vibrations yield a wide and rich spectrum of essential information regarding the functioning of the heart, and thus it is necessary to take advantage of this data to better monitor cardiac health by way of prevention in early stages. Specifically, seismocardiography (SCG) is a noninvasive technique that can record cardiac vibrations by using new cutting-edge devices as accelerometers. Therefore, providing new and reliable data regarding advancements in the field of SCG, i.e., new devices and tools, is necessary to outperform the current understanding of the State-of-the-Art (SoTA). This paper reviews the SoTA on SCG and concentrates on three critical aspects of the SCG approach, i.e., on the acquisition, annotation, and its current applications. Moreover, this comprehensive overview also presents a detailed summary of recent advancements in SCG, such as the adoption of new techniques based on the artificial intelligence field, e.g., machine learning, deep learning, artificial neural networks, and fuzzy logic. Finally, a discussion on the open issues and future investigations regarding the topic is included.
Collapse
|
10
|
Combining 4D Flow MRI and Complex Networks Theory to Characterize the Hemodynamic Heterogeneity in Dilated and Non-dilated Human Ascending Aortas. Ann Biomed Eng 2021; 49:2441-2453. [PMID: 34080100 PMCID: PMC8455395 DOI: 10.1007/s10439-021-02798-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 05/17/2021] [Indexed: 12/29/2022]
Abstract
Motivated by the evidence that the onset and progression of the aneurysm of the ascending aorta (AAo) is intertwined with an adverse hemodynamic environment, the present study characterized in vivo the hemodynamic spatiotemporal complexity and organization in human aortas, with and without dilated AAo, exploring the relations with clinically relevant hemodynamic and geometric parameters. The Complex Networks (CNs) theory was applied for the first time to 4D flow magnetic resonance imaging (MRI) velocity data of ten patients, five of them presenting with AAo dilation. The time-histories along the cardiac cycle of velocity-based quantities were used to build correlation-based CNs. The CNs approach succeeded in capturing large-scale coherent flow features, delimiting flow separation and recirculation regions. CNs metrics highlighted that an increasing AAo dilation (expressed in terms of the ratio between the maximum AAo and aortic root diameter) disrupts the correlation in forward flow reducing the correlation persistence length, while preserving the spatiotemporal homogeneity of secondary flows. The application of CNs to in vivo 4D MRI data holds promise for a mechanistic understanding of the spatiotemporal complexity and organization of aortic flows, opening possibilities for the integration of in vivo quantitative hemodynamic information into risk stratification and classification criteria.
Collapse
|