1
|
Liang J, Wang J, Wang M, Yao W. Pathogenic mechanism analysis of cochlear key structural lesion and phonosensitive hearing loss. Biomech Model Mechanobiol 2024; 23:87-101. [PMID: 37548872 DOI: 10.1007/s10237-023-01760-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 07/26/2023] [Indexed: 08/08/2023]
Abstract
Due to ethical issues and the very fine and complex structure of the cochlea, it is difficult to directly perform experimental measurement on the human cochlea. Therefore, the finite element method has become an effective and replaceable new research means. Accurate numerical analysis on human ear using finite element method can provide better understanding of sound transmission and can be used to assess the influence of diseases on hearing and to treat hearing loss. In this research, a three-dimensional (3D) finite element model (FEM) of the human ear of cochlea was presented to investigate the destruction of basilar membrane (BM), round window (RW) sclerosis and perilymph fistula, the key structures of the cochlea, and analyze the effects of these abnormal pathological states in the cochlea on cochlear hearing, resulting in the changes in cochlear sense structure biomechanical behavior and quantitative prediction of the degree and harm of the disorder to the decline of human hearing. Therefore, this paper can deepen reader's understanding of the cochlear biomechanical mechanism and provide a theoretical foundation for clinical otology.
Collapse
Affiliation(s)
- Junyi Liang
- Genomic Medicine Institute, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, OH, 44106, USA
| | - Jiakun Wang
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, 200072, People's Republic of China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai, 200072, People's Republic of China
| | - Mianzhi Wang
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, 200072, People's Republic of China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai, 200072, People's Republic of China
| | - Wenjuan Yao
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, 200072, People's Republic of China.
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai, 200072, People's Republic of China.
| |
Collapse
|
2
|
Wang J, Liang J, Gao L, Yao W. Study on damage of the macrostructure of the cochlea under the impact load. Proc Inst Mech Eng H 2023; 237:1390-1399. [PMID: 37955248 DOI: 10.1177/09544119231209187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2023]
Abstract
Due to the tiny and delicate structure of the cochlea, the auditory system is the most sensitive to explosion impact damage. After being damaged by the explosion impact wave, it usually causes long-term deafness, tinnitus, and other symptoms. To better understand the influence of impact load on the cochlea and basilar membrane (BM), a three-dimensional (3D) fluid-solid coupling finite element model was developed. This model accurately reflects the actual spatial spiral shape of the human cochlea, as well as the lymph environment and biological materials. Based on verifying the reliability of the model, the curve of impact load-amplitude response was obtained, and damage of impact load on the cochlea and the key macrostructure-BM was analyzed. The results indicate that impact wave at middle frequency has widest influence on the cochlea. Furthermore, impact loading causes tears in the BM and destroys the cochlear frequency selectivity.
Collapse
Affiliation(s)
- Jiakun Wang
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, China
| | - Junyi Liang
- Genomic Medicine Institute, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Lei Gao
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, China
| | - Wenjuan Yao
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, China
| |
Collapse
|
3
|
Gao L, Wang J, Liang J, Yao W, Zhou L, Huang X. Study of fatigue damage to the cochlea. Comput Methods Biomech Biomed Engin 2023; 26:2047-2056. [PMID: 36629847 DOI: 10.1080/10255842.2022.2164712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/17/2022] [Accepted: 12/28/2022] [Indexed: 01/12/2023]
Abstract
In order to explore the hearing loss resulting from exposure to continuous or intermittent loud noise. A three-dimensional liquid-solid coupling finite element model of spiral cochlea was established. The reliability of the model was verified, and the stress and amplitude of the basilar membrane of the pivotal structure in cochlea were analyzed. The results show that under the action of the same high-pressure sound, the preferential fatigue area of the cochlear high-frequency area mainly causes fatigue in the cochlear. The safer area is a sound pressure level below 70 dB, while one above 90 dB accelerates damage to the ear.
Collapse
Affiliation(s)
- Lei Gao
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, China
| | - Jiakun Wang
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, China
| | - Junyi Liang
- Genomic Medicine Institute, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Wenjuan Yao
- School of Mechanics and Engineering Science, Shanghai University, Shanghai, China
- Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai, China
| | - Lei Zhou
- Otorhinolaryngology-Head and Neck Surgery, Zhongshan Hospital affiliated to Fudan University, Shanghai, China
| | - Xinsheng Huang
- Otorhinolaryngology-Head and Neck Surgery, Zhongshan Hospital affiliated to Fudan University, Shanghai, China
| |
Collapse
|
4
|
Bradshaw JJ, Brown MA, Jiang S, Gan RZ. 3D Finite Element Model of Human Ear with 3-Chamber Spiral Cochlea for Blast Wave Transmission from the Ear Canal to Cochlea. Ann Biomed Eng 2023; 51:1106-1118. [PMID: 37036617 DOI: 10.1007/s10439-023-03200-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 03/29/2023] [Indexed: 04/11/2023]
Abstract
Blast-induced auditory trauma is a common injury in military service members and veterans that leads to hearing loss. While the inner ear response to blast exposure is difficult to characterize experimentally, computational models have advanced to predict blast wave transmission from the ear canal to the cochlea; however, published models have either straight or spiral cochlea with fluid-filled two chambers. In this paper, we report the recently developed 3D finite element (FE) model of the human ear mimicking the anatomical structure of the 3-chambered cochlea. The model consists of the ear canal, middle ear, and two and a half turns of the cochlea with three chambers separated by the Reissner's membrane (RM) and the basilar membrane (BM). The blast overpressure measured from human temporal bone experiments was applied at the ear canal entrance and the Fluent/Mechanical coupled fluid-structure interaction analysis was conducted in ANSYS software. The FE model-derived results include the pressure in the canal near the tympanic membrane (TM) and the intracochlear pressure at scala vestibuli, the TM displacement, and the stapes footplate (SFP) displacement, which were compared with experimentally measured data in human temporal bones. The validated model was used to predict the biomechanical response of the ear to blast overpressure: distributions of the maximum strain and stress within the TM, the BM displacement variation from the base to apex, and the energy flux or total energy entering the cochlea. The comparison of intracochlear pressure and BM displacement with those from the FE model of 2-chambered cochlea indicated that the 3-chamber cochlea model with the RM and scala media chamber improved our understanding of cochlea mechanics. This most comprehensive FE model of the human ear has shown its capability to predict the middle ear and cochlea responses to blast overpressure which will advance our understanding of auditory blast injury.
Collapse
Affiliation(s)
- John J Bradshaw
- School of Biomedical Engineering, University of Oklahoma, 173 Felgar Street, Room 101, Norman, OK, 73019, USA
| | - Marcus A Brown
- School of Biomedical Engineering, University of Oklahoma, 173 Felgar Street, Room 101, Norman, OK, 73019, USA
| | - Shangyuan Jiang
- School of Aerospace and Mechanical Engineering, University of Oklahoma, 865 Asp Avenue, Room 200, Norman, OK, 73019, USA
| | - Rong Z Gan
- School of Biomedical Engineering, University of Oklahoma, 173 Felgar Street, Room 101, Norman, OK, 73019, USA.
- School of Aerospace and Mechanical Engineering, University of Oklahoma, 865 Asp Avenue, Room 200, Norman, OK, 73019, USA.
| |
Collapse
|
5
|
Yu YC, Wang TC, Shih TC. A comprehensive finite-element human ear model to estimate noise-induced hearing loss associated with occupational noise exposure. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107179. [PMID: 36306646 DOI: 10.1016/j.cmpb.2022.107179] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 09/17/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND AND OBJECTIVE Noise is a common occupational and environmental hazard; however, little is known about the use of computational tools to quantitively analyze data on basilar membrane (BM) damage in noise-induced hearing loss (NIHL). Here, we established a comprehensive three-dimensional finite-element human ear model to quantify the impact of noise exposure on BM and perilymph fluid. METHODS We used auditory risk units (ARUs) to evaluate the BM damage for subjects (3 men and 5 women; mean age, 32.75 ± 8.86 years; age range, 24-44 years). A 90-dB sound pressure level (SPL) was normally applied at the external auditory canal (EAC) entrance to simulate sound transmission from the EAC to the cochlea at frequencies of 0.2-10.0 kHz. RESULTS The pressure distribution of perilymph fluid is totally different on frequency responses under low and high sound-evoked (0.013-10.0 kHz). The highest ARUs were 18.479% at the distance of 1 mm from the base, and the second-highest to fourth-highest ARUs occurred at distances of 5-7 mm from the base, where their ARUs were 9.749%, 9.176%, and 11.231%. The total of the ARUs reached 81.956% at external frequencies' sounds of 3.2-5.0 kHz. Among these, the 3.8-kHz and 3.6-kHz frequencies yielded the highest and second-highest ARUs of 20.325% and 19.873%, respectively. CONCLUSIONS This study would inform our understanding of NIHL associated with occupational noise exposure. We present a FE modelling and describe how it might provide a unique way to unravel mechanisms that drive NIHL due to loud noises.
Collapse
Affiliation(s)
- You-Cheng Yu
- Department of Biomedical Imaging and Radiological Science, College of Medicine, China Medical University, Taichung 406040, Taiwan
| | - Tang-Chuan Wang
- School of Medicine, College of Medicine, China Medical University, Taichung 406040, Taiwan; Department of Public Health, College of Public Health, China Medical University, Taichung 406040, Taiwan; Department of Otolaryngology-Head and Neck Surgery, China Medical University Hsinchu Hospital, Zhubei City, Hsinchu County 302056, Taiwan
| | - Tzu-Ching Shih
- Department of Biomedical Imaging and Radiological Science, College of Medicine, China Medical University, Taichung 406040, Taiwan; The PhD Program for Medical Engineering and Rehabilitation Science, College of Biomedical Engineering, China Medical University, Taichung 406040, Taiwan.
| |
Collapse
|
6
|
Brown MA, Bradshaw JJ, Gan RZ. Three-Dimensional Finite Element Modeling of Blast Wave Transmission From the External Ear to a Spiral Cochlea. J Biomech Eng 2022; 144:014503. [PMID: 34318317 PMCID: PMC10782861 DOI: 10.1115/1.4051925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 07/22/2021] [Indexed: 11/08/2022]
Abstract
Blast-induced injuries affect the health of veterans, in which the auditory system is often damaged, and blast-induced auditory damage to the cochlea is difficult to quantify. A recent study modeled blast overpressure (BOP) transmission throughout the ear utilizing a straight, two-chambered cochlea, but the spiral cochlea's response to blast exposure has yet to be investigated. In this study, we utilized a human ear finite element (FE) model with a spiraled, two-chambered cochlea to simulate the response of the anatomical structural cochlea to BOP exposure. The FE model included an ear canal, middle ear, and two and half turns of two-chambered cochlea and simulated a BOP from the ear canal entrance to the spiral cochlea in a transient analysis utilizing fluid-structure interfaces. The model's middle ear was validated with experimental pressure measurements from the outer and middle ear of human temporal bones. The results showed high stapes footplate (SFP) displacements up to 28.5 μm resulting in high intracochlear pressures and basilar membrane (BM) displacements up to 43.2 μm from a BOP input of 30.7 kPa. The cochlea's spiral shape caused asymmetric pressure distributions as high as 4 kPa across the cochlea's width and higher BM transverse motion than that observed in a similar straight cochlea model. The developed spiral cochlea model provides an advancement from the straight cochlea model to increase the understanding of cochlear mechanics during blast and progresses toward a model able to predict potential hearing loss after blast.
Collapse
Affiliation(s)
- Marcus A. Brown
- Biomedical Engineering Laboratory, Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019
| | - John J. Bradshaw
- Biomedical Engineering Laboratory, Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019
| | - Rong Z. Gan
- Professor of Biomedical Engineering, Biomedical Engineering Laboratory, School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019
| |
Collapse
|
7
|
Sekine Y, Saitoh D, Yoshimura Y, Fujita M, Araki Y, Kobayashi Y, Kusumi H, Yamagishi S, Suto Y, Tamaki H, Ono Y, Mizukaki T, Nemoto M. Efficacy of Body Armor in Protection Against Blast Injuries Using a Swine Model in a Confined Space with a Blast Tube. Ann Biomed Eng 2021; 49:2944-2956. [PMID: 33686618 PMCID: PMC8510944 DOI: 10.1007/s10439-021-02750-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 02/05/2021] [Indexed: 01/04/2023]
Abstract
The purpose of this study was to clarify whether or not body armor would protect the body of a swine model using a blast tube built at National Defense Medical College, which is the first such blast tube in Japan. Seventeen pigs were divided into two groups: the body armor group and the non-body armor group. Under intravenous anesthesia, the pigs were tightly fixed in the left lateral position on a table and exposed from the back neck to the upper lumbar back to the blast wave and wind with or without body armor, with the driving pressure of the blast tube set to 3.0 MPa. When the surviving and dead pigs were compared, blood gas analyses revealed significant differences in PaO2, PaCO2, and pH in the super-early phase. All pigs injured by the blast wave and wind had lung hemorrhage. All 6 animals in the body armor group and 6 of the 11 animals in the control group survived for 3 hours after injury. Respiratory arrest immediately after exposure to the blast wave was considered to influence the mortality in our pig model. Body armor may have a beneficial effect in protecting against respiratory arrest immediately after an explosion.
Collapse
Affiliation(s)
- Yasumasa Sekine
- Division of Traumatology, Research Institute, National Defense Medical College (NDMC), 3-2 Namiki, Tokorozawa, 359-8513 Japan ,Dept. of Traumatology and Critical Care Medicine, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan ,Dept. of Emergency and Trauma Care, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama 350-1298 Japan
| | - Daizoh Saitoh
- Division of Traumatology, Research Institute, National Defense Medical College (NDMC), 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Yuya Yoshimura
- Dept. of Traumatology and Critical Care Medicine, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Masanori Fujita
- Division of Environmental Medicine, Research Institute, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Yoshiyuki Araki
- Dept. of Defense Medicine, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | | | - Hitomi Kusumi
- Dept. of Military Nursing, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Satomi Yamagishi
- Dept. of Military Nursing, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Yuki Suto
- Division of Traumatology, Research Institute, National Defense Medical College (NDMC), 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Hiroshi Tamaki
- Division of Graduate School, Dept. of Academic Affairs, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan
| | - Yosuke Ono
- Department of General Medicine, NDMC, 3-2 Namiki, Tokorozawa, 359-8513 Japan ,Military Medicine Research Unit, Test and Evaluation Command, Japan Ground Self Defense Force, 1-2-24 Ikejiri, setagaya-ku, Tokyo, 154-0004 Japan
| | - Toshiharu Mizukaki
- Dept. of Aeronautics and Astronautics, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292 Japan
| | - Manabu Nemoto
- Dept. of Emergency and Trauma Care, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama 350-1298 Japan
| |
Collapse
|