Meyer K, Søes Ibsen M, Vetter-Joss L, Broberg Hansen E, Abildskov J. Industrial ion-exchange chromatography development using discontinuous Galerkin methods coupled with forward sensitivity analysis.
J Chromatogr A 2023;
1689:463741. [PMID:
36586279 DOI:
10.1016/j.chroma.2022.463741]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 12/20/2022] [Accepted: 12/20/2022] [Indexed: 12/25/2022]
Abstract
In this work, a discontinuous Galerkin method coupled with forward sensitivity analysis (DG-FSA) is presented. The DG-FSA method is used to reduce computational cost required for model-based ion-exchange chromatography development using industrial load samples. As an example, the design of an anion-exchange chromatography step is considered. This step is used to purify an experimental peptide product called Protein G from Novo Nordisk A/S (Bagsværd, Denmark). The results demonstrate, that a fourth order DG-FSA method can reduce computational cost of inverse problems by a factor ×16 compared to a second (low) order DG-FSA method. Furthermore, the fourth-order DG-FSA method enable the computation of probability distributions of optimized processing conditions given uncertainty in model parameters or inputs. This analysis is not possible within a reasonable timeframe when applying the second (low) order DG-FSA method. The design procedure facilitates the optimization of the Protein G purification step. In an experimental validation run, the productivity is increased by 70% while sacrificing 4% yield at a similar purity constraint compared to an experiment with baseline performance.
Collapse