1
|
de Gans CJ, Burger P, van den Ende ES, Hermanides J, Nanayakkara PWB, Gemke RJBJ, Rutters F, Stenvers DJ. Sleep assessment using EEG-based wearables - A systematic review. Sleep Med Rev 2024; 76:101951. [PMID: 38754209 DOI: 10.1016/j.smrv.2024.101951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 04/26/2024] [Accepted: 05/06/2024] [Indexed: 05/18/2024]
Abstract
Polysomnography (PSG) is the reference standard of sleep measurement, but is burdensome for the participant and labor intensive. Affordable electroencephalography (EEG)-based wearables are easy to use and are gaining popularity, yet selecting the most suitable device is a challenge for clinicians and researchers. In this systematic review, we aim to provide a comprehensive overview of available EEG-based wearables to measure human sleep. For each wearable, an overview will be provided regarding validated population and reported measurement properties. A systematic search was conducted in the databases OVID MEDLINE, Embase.com and CINAHL. A machine learning algorithm (ASReview) was utilized to screen titles and abstracts for eligibility. In total, 60 papers were selected, covering 34 unique EEG-based wearables. Feasibility studies indicated good tolerance, high compliance, and success rates. The 42 included validation studies were conducted across diverse populations and showed consistently high accuracy in sleep staging detection. Therefore, the recent advancements in EEG-based wearables show great promise as alternative for PSG and for at-home sleep monitoring. Users should consider factors like user-friendliness, comfort, and costs, as these devices vary in features and pricing, impacting their suitability for individual needs.
Collapse
Affiliation(s)
- C J de Gans
- Department of Internal Medicine, Section General Internal Medicine Unit Acute Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands; Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.
| | - P Burger
- Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands; Department of Pediatrics, Emma Children's Hospital, Amsterdam University Medical Center, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | - E S van den Ende
- Department of Internal Medicine, Section General Internal Medicine Unit Acute Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands; Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - J Hermanides
- Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands; Department of Anesthesiology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - P W B Nanayakkara
- Department of Internal Medicine, Section General Internal Medicine Unit Acute Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands; Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - R J B J Gemke
- Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands; Department of Pediatrics, Emma Children's Hospital, Amsterdam University Medical Center, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | - F Rutters
- Amsterdam Public Health Research Institute, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands; Department of Epidemiology and Data Science, Amsterdam University Medical Center, the Netherlands
| | - D J Stenvers
- Department of Endocrinology and Metabolism, Amsterdam UMC, University of Amsterdam, Department Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Gastroenterology Endocrinology and Metabolism (AGEM), Amsterdam, the Netherlands
| |
Collapse
|
2
|
Emish M, Young SD. Remote Wearable Neuroimaging Devices for Health Monitoring and Neurophenotyping: A Scoping Review. Biomimetics (Basel) 2024; 9:237. [PMID: 38667247 PMCID: PMC11048695 DOI: 10.3390/biomimetics9040237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 04/05/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024] Open
Abstract
Digital health tracking is a source of valuable insights for public health research and consumer health technology. The brain is the most complex organ, containing information about psychophysical and physiological biomarkers that correlate with health. Specifically, recent developments in electroencephalogram (EEG), functional near-infra-red spectroscopy (fNIRS), and photoplethysmography (PPG) technologies have allowed the development of devices that can remotely monitor changes in brain activity. The inclusion criteria for the papers in this review encompassed studies on self-applied, remote, non-invasive neuroimaging techniques (EEG, fNIRS, or PPG) within healthcare applications. A total of 23 papers were reviewed, comprising 17 on using EEGs for remote monitoring and 6 on neurofeedback interventions, while no papers were found related to fNIRS and PPG. This review reveals that previous studies have leveraged mobile EEG devices for remote monitoring across the mental health, neurological, and sleep domains, as well as for delivering neurofeedback interventions. With headsets and ear-EEG devices being the most common, studies found mobile devices feasible for implementation in study protocols while providing reliable signal quality. Moderate to substantial agreement overall between remote and clinical-grade EEGs was found using statistical tests. The results highlight the promise of portable brain-imaging devices with regard to continuously evaluating patients in natural settings, though further validation and usability enhancements are needed as this technology develops.
Collapse
Affiliation(s)
- Mohamed Emish
- Department of Informatics, University of California, Irvine, CA 92697-3100, USA;
| | - Sean D. Young
- Department of Informatics, University of California, Irvine, CA 92697-3100, USA;
- Department of Emergency Medicine, University of California, Irvine, CA 92697-3100, USA
| |
Collapse
|
3
|
Warsito IF, Komosar M, Bernhard MA, Fiedler P, Haueisen J. Flower electrodes for comfortable dry electroencephalography. Sci Rep 2023; 13:16589. [PMID: 37789022 PMCID: PMC10547758 DOI: 10.1038/s41598-023-42732-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 09/14/2023] [Indexed: 10/05/2023] Open
Abstract
Dry electroencephalography (EEG) electrodes provide rapid, gel-free, and easy EEG preparation, but with limited wearing comfort. We propose a novel dry electrode comprising multiple tilted pins in a flower-like arrangement. The novel Flower electrode increases wearing comfort and contact area while maintaining ease of use. In a study with 20 volunteers, we compare the performance of a novel 64-channel dry Flower electrode cap to a commercial dry Multipin electrode cap in sitting and supine positions. The wearing comfort of the Flower cap was rated as significantly improved both in sitting and supine positions. The channel reliability and average impedances of both electrode systems were comparable. Averaged VEP components showed no considerable differences in global field power amplitude and latency, as well as in signal-to-noise ratio and topography. No considerable differences were found in the power spectral density of the resting state EEGs between 1 and 40 Hz. Overall, our findings provide evidence for equivalent channel reliability and signal characteristics of the compared cap systems in the sitting and supine positions. The reliability, signal quality, and significantly improved wearing comfort of the Flower electrode allow new fields of applications for dry EEG in long-term monitoring, sensitive populations, and recording in supine position.
Collapse
Affiliation(s)
- Indhika Fauzhan Warsito
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Milana Komosar
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Maria Anne Bernhard
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany.
- Department of Neurology, Biomagnetic Center, University Hospital Jena, Jena, Germany.
| |
Collapse
|
4
|
Effects of SMR Neurofeedback on Cognitive Functions in an Adult Population with Sleep Problems: A Tele-neurofeedback Study. Appl Psychophysiol Biofeedback 2023; 48:27-33. [PMID: 36114953 DOI: 10.1007/s10484-022-09560-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/07/2022] [Indexed: 11/02/2022]
Abstract
A good night's sleep is vital for normal human cognitive performance. We earlier reported that a home-based tele-neurofeedback program effectively reduced sleep problems (Krepel et al. in Appl Psychophysiol Biofeedback, https://doi.org/10.1007/s10484-021-09525-z , 2021). The present article presents a follow-up on this earlier study and investigates improvements in cognitive functions after sensory-motor rhythm (SMR) neurofeedback. Thirty-seven participants reporting sleep problems received SMR neurofeedback. Cognitive measures were assessed pre- and post-treatment. Measurements included a continuous performance/working memory (CPT/WM) task, Stroop task, and Trailmaking A and B test (from the IntegNeuro cognitive test battery). For neurofeedback-Learners relative to non-Learners significantly improved CPT/WM response time (d = 0.50), omission errors (d = 0.67), and Stroop incongruent performance (d = 0.72) were found. A significant time effect for both groups were found for the Stroop, the Trailmaking test part B (d = 0.52), and the Stroop interference score (d = 0.55). No significant correlations between changes in sleep and changes in cognition (p > 0.05) were found for the sample. SMR neurofeedback specifically improved measures of attention (response time and omission errors in a CPT/WM test) and working memory (Stroop incongruent) for SMR Learners compared to non-Learners with medium effect sizes. Furthermore, overall improvements for the whole sample were found on measures of executive function and visual attention, possibly reflecting non-specific or practice effects. Future better powered randomized control trials are needed to investigate if cognitive improvements are a direct effect of SMR neurofeedback or mediated by sleep improvements.
Collapse
|
5
|
Autenrieth M, Kober SE, Wood G. Assessment of the capacity to modulate brain signals in a home-based SMR neurofeedback training setting. Front Hum Neurosci 2023; 16:1032222. [PMID: 36684842 PMCID: PMC9849904 DOI: 10.3389/fnhum.2022.1032222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 12/12/2022] [Indexed: 01/07/2023] Open
Abstract
Electroencephalogram (EEG)-based neurofeedback (NF) is mainly used in clinical settings as a therapeutic intervention or to optimize performance in healthy individuals. Home-based NF systems are available and might facilitate general access to NF training, especially when repeated training sessions are necessary. However, it remains an open question whether NF training at home is possible without remote monitoring. In the present study, we assessed the capacity of healthy individuals to modulate their own EEG activity when using a home-based NF training system in a comparable manner as if participants had purchased a commercially available NF system. Participants' face-to-face contact with experimenters was reduced to a minimum, and instructions were provided only in the form of written information or videos. Initially, 38 participants performed 9 sessions of sensorimotor rhythm (SMR) (12-15 Hz) based NF training (three generalization sessions, six training sessions). An active control group (n = 19) received feedback on random EEG frequencies. Because of technical problems, bad EEG data quality, or non-compliance, 21 participants had to be excluded from the final data analysis, providing first evidence for the difficulties of non-supervised home-based NF training. In this study, participants were not able to modulate their own brain activity in a desired direction during NF training. Our results indicate that personal interaction with a NF expert might be of relevance and that remote supervision of the training data and more direct communication with the NF users are necessary to enable successful NF training performance. We provide suggestions for the development and implementation of home-based NF systems.
Collapse
Affiliation(s)
| | - Silvia Erika Kober
- Institute of Psychology, University of Graz, Graz, Austria,BioTechMed-Graz, Graz, Austria
| | - Guilherme Wood
- Institute of Psychology, University of Graz, Graz, Austria,BioTechMed-Graz, Graz, Austria,*Correspondence: Guilherme Wood,
| |
Collapse
|
6
|
A Single Session of SMR-Neurofeedback Training Improves Selective Attention Emerging from a Dynamic Structuring of Brain-Heart Interplay. Brain Sci 2022; 12:brainsci12060794. [PMID: 35741679 PMCID: PMC9221475 DOI: 10.3390/brainsci12060794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/13/2022] [Accepted: 06/14/2022] [Indexed: 11/17/2022] Open
Abstract
Research on sensorimotor rhythms (SMR) based on neurofeedback (NFb) emphasizes improvements in selective attention associated with SMR amplification. However, the long-term training proposed in most studies posed the question of acceptability, which led to the evaluation of the potential of a single NFb session. Based on cognitive and autonomic controls interfering with attention processes, we hypothesized changes in selective attention after a single SMR-NFb session, along with changes in brain-heart interplay, which are reflected in the multifractality of heartbeat dynamics. Here, young healthy participants (n = 35, 20 females, 21 ± 3 years) were randomly assigned either to a control group (Ctrl) watching a movie or to a neurofeedback (NFb) group performing a single session of SMR-NFb. A headset with EEG electrodes (positioned on C3 and C4) connected to a smartphone app served to guide and to evaluate NFb training efficacy. A Stroop task was performed for 8 min by each group before and after the intervention (movie vs. SMR-NFb) while collecting heart rate variability and C4-EEG for 20 min. When compared to Ctrl, the NFb group exhibited better Stroop performance, especially when facing incongruent trials. The multifractality and NFb training efficacy were identified as strong predictors of the gain in global Stroop performance, while multifractality was the only predictor regarding incongruent trials. We conclude that a single session of SMR-NFb improves selective attention in healthy individuals through the specific reorganization of brain-heart interplay, which is reflected in multifractal heartbeat dynamics.
Collapse
|