1
|
Brisinda D, Fenici P, Fenici R. Clinical magnetocardiography: the unshielded bet-past, present, and future. Front Cardiovasc Med 2023; 10:1232882. [PMID: 37636301 PMCID: PMC10448194 DOI: 10.3389/fcvm.2023.1232882] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 06/23/2023] [Indexed: 08/29/2023] Open
Abstract
Magnetocardiography (MCG), which is nowadays 60 years old, has not yet been fully accepted as a clinical tool. Nevertheless, a large body of research and several clinical trials have demonstrated its reliability in providing additional diagnostic electrophysiological information if compared with conventional non-invasive electrocardiographic methods. Since the beginning, one major objective difficulty has been the need to clean the weak cardiac magnetic signals from the much higher environmental noise, especially that of urban and hospital environments. The obvious solution to record the magnetocardiogram in highly performant magnetically shielded rooms has provided the ideal setup for decades of research demonstrating the diagnostic potential of this technology. However, only a few clinical institutions have had the resources to install and run routinely such highly expensive and technically demanding systems. Therefore, increasing attempts have been made to develop cheaper alternatives to improve the magnetic signal-to-noise ratio allowing MCG in unshielded hospital environments. In this article, the most relevant milestones in the MCG's journey are reviewed, addressing the possible reasons beyond the currently long-lasting difficulty to reach a clinical breakthrough and leveraging the authors' personal experience since the early 1980s attempting to finally bring MCG to the patient's bedside for many years thus far. Their nearly four decades of foundational experimental and clinical research between shielded and unshielded solutions are summarized and referenced, following the original vision that MCG had to be intended as an unrivaled method for contactless assessment of the cardiac electrophysiology and as an advanced method for non-invasive electroanatomical imaging, through multimodal integration with other non-fluoroscopic imaging techniques. Whereas all the above accounts for the past, with the available innovative sensors and more affordable active shielding technologies, the present demonstrates that several novel systems have been developed and tested in multicenter clinical trials adopting both shielded and unshielded MCG built-in hospital environments. The future of MCG will mostly be dependent on the results from the ongoing progress in novel sensor technology, which is relatively soon foreseen to provide multiple alternatives for the construction of more compact, affordable, portable, and even wearable devices for unshielded MCG inside hospital environments and perhaps also for ambulatory patients.
Collapse
Affiliation(s)
- D. Brisinda
- Dipartimento Scienze dell'invecchiamento, ortopediche e reumatologiche, Fondazione Policlinico Universitario Agostino Gemelli, IRCCS, Rome, Italy
- School of Medicine and Surgery, Catholic University of the Sacred Heart, Rome, Italy
- Biomagnetism and Clinical Physiology International Center (BACPIC), Rome, Italy
| | - P. Fenici
- School of Medicine and Surgery, Catholic University of the Sacred Heart, Rome, Italy
- Biomagnetism and Clinical Physiology International Center (BACPIC), Rome, Italy
| | - R. Fenici
- Biomagnetism and Clinical Physiology International Center (BACPIC), Rome, Italy
| |
Collapse
|
2
|
Skidchenko E, Butorina A, Ostras M, Vetoshko P, Kuzmichev A, Yavich N, Malovichko M, Koshev N. Yttrium-Iron Garnet Magnetometer in MEG: Advance towards Multi-Channel Arrays. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094256. [PMID: 37177460 PMCID: PMC10181089 DOI: 10.3390/s23094256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/17/2023] [Accepted: 04/23/2023] [Indexed: 05/15/2023]
Abstract
Recently, a new kind of sensor applicable in magnetoencephalography (MEG) has been presented: a solid-state yttrium-iron garnet magnetometer (YIGM). The feasibility of yttrium-iron garnet magnetometers (YIGMs) was demonstrated in an alpha-rhythm registration experiment. In this paper, we propose the analysis of lead-field matrices for different possible multi-channel on-scalp sensor layouts using YIGMs with respect to information theory. Real noise levels of the new sensor were used to compute signal-to-noise ratio (SNR) and total information capacity (TiC), and compared with corresponding metrics that can be obtained with well-established MEG systems based on superconducting quantum interference devices (SQUIDs) and optically pumped magnetometers (OPMs). The results showed that due to YIGMs' proximity to the subject's scalp, they outperform SQUIDs and OPMs at their respective noise levels in terms of SNR and TiC. However, the current noise levels of YIGM sensors are unfortunately insufficient for constructing a multichannel YIG-MEG system. This simulation study provides insight into the direction for further development of YIGM sensors to create a multi-channel MEG system, namely, by decreasing the noise levels of sensors.
Collapse
Affiliation(s)
| | - Anna Butorina
- CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
| | - Maxim Ostras
- M-Granat, Russian Quantum Center, 121205 Moscow, Russia
| | - Petr Vetoshko
- M-Granat, Russian Quantum Center, 121205 Moscow, Russia
- Laboratory of Magnetic Phenomena in Microelectronics, Kotelnikov Institute of Radioengineering and Electronics of RAS, 125009 Moscow, Russia
| | | | - Nikolay Yavich
- CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
- Computational Geophysics Lab, Moscow Institute of Physics and Technology, 141701 Dolgoprudny, Russia
| | - Mikhail Malovichko
- Computational Geophysics Lab, Moscow Institute of Physics and Technology, 141701 Dolgoprudny, Russia
| | - Nikolay Koshev
- CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
| |
Collapse
|
3
|
Koshev N, Butorina A, Skidchenko E, Kuzmichev A, Ossadtchi A, Ostras M, Fedorov M, Vetoshko P. Evolution of MEG: A first MEG-feasible fluxgate magnetometer. Hum Brain Mapp 2021; 42:4844-4856. [PMID: 34327772 PMCID: PMC8449095 DOI: 10.1002/hbm.25582] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 05/24/2021] [Accepted: 06/10/2021] [Indexed: 11/15/2022] Open
Abstract
In the current article, we present the first solid‐state sensor feasible for magnetoencephalography (MEG) that works at room temperature. The sensor is a fluxgate magnetometer based on yttrium‐iron garnet films (YIGM). In this feasibility study, we prove the concept of usage of the YIGM in terms of MEG by registering a simple brain induced field—the human alpha rhythm. All the experiments and results are validated with usage of another kind of high‐sensitive magnetometers—optically pumped magnetometer, which currently appears to be well‐established in terms of MEG.
Collapse
Affiliation(s)
- Nikolay Koshev
- Skolkovo Institute of Science and Technology, Moscow, Russia
| | - Anna Butorina
- Skolkovo Institute of Science and Technology, Moscow, Russia
| | | | | | | | - Maxim Ostras
- M-Granat, Russian Quantum Center, Moscow, Russia
| | - Maxim Fedorov
- Skolkovo Institute of Science and Technology, Moscow, Russia
| | - Petr Vetoshko
- M-Granat, Russian Quantum Center, Moscow, Russia.,Kotelnikov Institute of Radioengineering and Electronics of RAS, Moscow, Russia
| |
Collapse
|
4
|
Bi Y, Huang L, Li X, Wang Y. Magnetically controllable metasurface and its application. FRONTIERS OF OPTOELECTRONICS 2021; 14:154-169. [PMID: 36637664 PMCID: PMC9743948 DOI: 10.1007/s12200-021-1125-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Accepted: 01/19/2021] [Indexed: 05/05/2023]
Abstract
The dynamic control of the metasurface opens up a vital technological approach for the development of multifunctional integrated optical devices. The magnetic field manipulation has the advantages of sub-nanosecond ultra-fast response, non-contact, and continuous adjustment. Thus, the magnetically controllable metasurface has attracted significant attention in recent years. This study introduces the basic principles of the Faraday and Kerr effect of magneto-optical (MO) materials. It classifies the typical MO materials according to their properties. It also summarizes the physical mechanism of different MO metasurfaces that combine the MO effect with plasmonic or dielectric resonance. Besides, their applications in the nonreciprocal device and MO sensing are demonstrated. The future perspectives and challenges of the research on MO metasurfaces are discussed.
Collapse
Affiliation(s)
- Yu Bi
- Key Laboratory of Photoelectronic Imaging Technology and System, Ministry of Education; School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Lingling Huang
- Key Laboratory of Photoelectronic Imaging Technology and System, Ministry of Education; School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.
| | - Xiaowei Li
- Laser Micro/Nano-Fabrication Laboratory, School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Yongtian Wang
- Key Laboratory of Photoelectronic Imaging Technology and System, Ministry of Education; School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| |
Collapse
|
5
|
Murzin D, Mapps DJ, Levada K, Belyaev V, Omelyanchik A, Panina L, Rodionova V. Ultrasensitive Magnetic Field Sensors for Biomedical Applications. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1569. [PMID: 32168981 PMCID: PMC7146409 DOI: 10.3390/s20061569] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 03/02/2020] [Accepted: 03/06/2020] [Indexed: 12/27/2022]
Abstract
The development of magnetic field sensors for biomedical applications primarily focuses on equivalent magnetic noise reduction or overall design improvement in order to make them smaller and cheaper while keeping the required values of a limit of detection. One of the cutting-edge topics today is the use of magnetic field sensors for applications such as magnetocardiography, magnetotomography, magnetomyography, magnetoneurography, or their application in point-of-care devices. This introductory review focuses on modern magnetic field sensors suitable for biomedicine applications from a physical point of view and provides an overview of recent studies in this field. Types of magnetic field sensors include direct current superconducting quantum interference devices, search coil, fluxgate, magnetoelectric, giant magneto-impedance, anisotropic/giant/tunneling magnetoresistance, optically pumped, cavity optomechanical, Hall effect, magnetoelastic, spin wave interferometry, and those based on the behavior of nitrogen-vacancy centers in the atomic lattice of diamond.
Collapse
Affiliation(s)
- Dmitry Murzin
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Desmond J. Mapps
- Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK;
| | - Kateryna Levada
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Victor Belyaev
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Alexander Omelyanchik
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Larissa Panina
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
- National University of Science and Technology, MISiS, 119049 Moscow, Russia
| | - Valeria Rodionova
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| |
Collapse
|