• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4618911)   Today's Articles (2427)   Subscriber (49402)
For: Telyshev DV, Denisov MV, Selishchev SV. The Effect of Rotor Geometry on the H−Q Curves of the Sputnik Implantable Pediatric Rotary Blood Pump. Biomed Eng 2017. [DOI: 10.1007/s10527-017-9669-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Number Cited by Other Article(s)
1
Hemodynamic Evaluation of a Centrifugal Left Atrial Decompression Pump for Heart Failure with Preserved Ejection Fraction. Bioengineering (Basel) 2023;10:bioengineering10030366. [PMID: 36978757 PMCID: PMC10044772 DOI: 10.3390/bioengineering10030366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/08/2023] [Accepted: 03/12/2023] [Indexed: 03/19/2023]  Open
2
Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study. J Funct Biomater 2022;13:jfb13010007. [PMID: 35076513 PMCID: PMC8788462 DOI: 10.3390/jfb13010007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/22/2021] [Accepted: 01/07/2022] [Indexed: 02/05/2023]  Open
3
Gautier SV, Shevchenko AO, Itkin GP, Zakharevich VM, Poptsov VN, Drobyshev AA, Telyshev DV. Artificial heart in Russia: Past, present, and future. Artif Organs 2020;45:111-114. [PMID: 33270245 DOI: 10.1111/aor.13860] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Accepted: 09/29/2020] [Indexed: 11/30/2022]
4
Telyshev DV. A Mathematical Model for Estimating Physiological Parameters of Blood Flow through Rotary Blood Pumps. BIOMEDICAL ENGINEERING 2020. [DOI: 10.1007/s10527-020-09996-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
5
Advances in Hemodynamic Analysis in Cardiovascular Diseases Investigation of Energetic Characteristics of Adult and Pediatric Sputnik Left Ventricular Assist Devices during Mock Circulation Support. Cardiol Res Pract 2019;2019:4593174. [PMID: 31885902 PMCID: PMC6925692 DOI: 10.1155/2019/4593174] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 09/11/2019] [Accepted: 10/17/2019] [Indexed: 11/17/2022]  Open
6
Telyshev D, Denisov M, Markov A, Fresiello L, Verbelen T, Selishchev S. Energetics of blood flow in Fontan circulation under VAD support. Artif Organs 2019;44:50-57. [DOI: 10.1111/aor.13564] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/21/2019] [Accepted: 08/26/2019] [Indexed: 12/27/2022]
7
Denisov MV, Telyshev DV, Selishchev SV, Romanova AN. Investigation of Hemocompatibility of Rotary Blood Pumps: The Case of the Sputnik Ventricular Assist Device. BIOMEDICAL ENGINEERING 2019. [DOI: 10.1007/s10527-019-09904-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
8
Telyshev D, Petukhov D, Selishchev S. Numerical modeling of continuous-flow left ventricular assist device performance. Int J Artif Organs 2019;42:611-620. [PMID: 31169054 DOI: 10.1177/0391398819852365] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
9
Numerical Modeling of Blood Flows in Rotary Pumps for Use in Pediatric Heart Surgery in Patients Undergoing the Fontan Procedure. BIOMEDICAL ENGINEERING 2019. [DOI: 10.1007/s10527-019-09857-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
10
Telyshev D, Denisov M, Pugovkin A, Selishchev S, Nesterenko I. The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development. Artif Organs 2018;42:432-443. [DOI: 10.1111/aor.13109] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 11/23/2017] [Accepted: 12/12/2017] [Indexed: 01/29/2023]
11
Telyshev DV, Pugovkin AA, Selishchev SV. A Mock Circulatory System for Testing Pediatric Rotary Blood Pumps. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA 2017. [DOI: 10.1007/s10527-017-9689-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA