Babaie Z, Kibar G, Yeşilkaya H, Amrani Y, Doğan S, Tuna BG, Özalp VC, Çetin B. Microfluidic rapid isolation and electrochemical detection of S. pneumonia via aptamer-decorated surfaces. Anal Chim Acta 2025; 1345:343726. [PMID: 40015771 DOI: 10.1016/j.aca.2025.343726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2024] [Revised: 01/01/2025] [Accepted: 01/23/2025] [Indexed: 03/01/2025]
Abstract
BACKGROUND S. pneumoniae is widely recognized as a leading cause of respiratory infections worldwide, often resulting in high mortality rates. However, the advent of microfluidic technologies has brought significant advancements, including the simplified, sensitive, cost-effective, and rapid approach to pneumococcal bacteremia detection. In this study, a microfluidic magnetic platform is presented for rapid isolation, and an electrode array is utilized for the electrochemical detection of S. pneumoniae. Aptamer-decorated surfaces were employed for both isolation and detection. For isolation, silica magnetic microparticles were synthesized and decorated with aptamer. RESULTS Isolation performance was assessed for phosphate-buffered saline (PBS) and blood samples for different concentrations of S. pneumoniae. Electrical impedance spectroscopy (EIS) with fabricated gold interdigitated electrodes (IDEs) decorated with aptamer was implemented for the detection of S. pneumoniae at different bacteria concentrations. The microfluidic platform performed bacteria isolation at comparable isolation efficiency with batch systems but at a much faster rate (isolation took about a minute, and the aptamer-decorated electrode array exhibited a limit of detection (LOD) at 962 CFU/mL and linear range between 104 and 107 CFU/mL. SIGNIFICANCE Our method represents a significant advancement compared to previous reports. Our microfluidic platform can efficiently isolate 60 μL of the bacteria sample within about one minute. The entire process takes about two minutes including the detection step. Furthermore, our method achieves a notable improvement in the detection limit for S. pneumoniae compared to conventional ELISA and magnetic microfluidics ELISA.
Collapse
Affiliation(s)
- Zahra Babaie
- Microfluidics & Lab-on-a-chip Research Group, Department of Mech. Eng., İ.D. Bilkent University, Ankara 06800, Turkiye; UNAM-National Nanotech. Research Center & Inst. Materials Science & Nanotech. İ.D. Bilkent University, Ankara 06800, Turkiye
| | - Güneş Kibar
- Microfluidics & Lab-on-a-chip Research Group, Department of Mech. Eng., İ.D. Bilkent University, Ankara 06800, Turkiye; UNAM-National Nanotech. Research Center & Inst. Materials Science & Nanotech. İ.D. Bilkent University, Ankara 06800, Turkiye; Micro Nano Particles (MNP) Research Group, Materials Sci. & Eng. Department of Adana Alparslan Turkes Science & Technology University, Adana 01250, Turkiye
| | - Hasan Yeşilkaya
- Department of Respiratory Sciences, Uni. Leicester, University Road, Leicester LE1 7RH, United Kingdom
| | - Yassine Amrani
- Department of Respiratory Sciences, Uni. Leicester, University Road, Leicester LE1 7RH, United Kingdom
| | - Soner Doğan
- Department of Medical Biology, School of Medicine, Yeditepe University, İstanbul 34755, Turkiye
| | - Bilge G Tuna
- Department of Medical Biophysics, School of Medicine, Yeditepe University, İstanbul 34755, Turkiye
| | - Veli C Özalp
- Department of Medical Biology, School of Medicine, Atılım University, Ankara 06830, Turkiye
| | - Barbaros Çetin
- Microfluidics & Lab-on-a-chip Research Group, Department of Mech. Eng., İ.D. Bilkent University, Ankara 06800, Turkiye; UNAM-National Nanotech. Research Center & Inst. Materials Science & Nanotech. İ.D. Bilkent University, Ankara 06800, Turkiye.
| |
Collapse
|
2
|
Sheu SC, Song YS, Chen JJ. A Portable Continuous-Flow Polymerase Chain Reaction Chip Device Integrated with Arduino Boards for Detecting Colla corii asini. MICROMACHINES 2022; 13:1289. [PMID: 36014212 PMCID: PMC9412515 DOI: 10.3390/mi13081289] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/09/2022] [Accepted: 08/10/2022] [Indexed: 06/15/2023]
Abstract
Food security is a significant issue in modern society. Because morphological characters are not reliable enough to distinguish authentic traditional Chinese medicines, it is essential to establish an effective and applicable method to identify them to protect people's health. Due to the expensive cost of the manufacturing process and the large volume of the analytical system, the need to build a portable and cheap device is urgent. This work describes the development of a portable nucleic acid amplification device integrated with thermal control and liquid pumping connecting to Arduino boards. We present a novel microfluidic polymerase chain reaction (PCR) chip with symmetric isothermal zones. The total chip volume is small, and only one Arduino board is needed for thermal control. We assemble a miniaturized liquid pump and program an Arduino file to push the sample mixture into the chip to implement the PCR process. In the proposed operation, the Nusselt number of the sample flow is less than one, and the heat transfer is conduction only. Then we can ensure temperature uniformity in specific reaction regions. A Colla corii asini DNA segment of 200 bp is amplified to evaluate the PCR performance under the various operational parameters. The initial concentration for accomplishing the PCR process is at least 20 ng/μL at the flow rate of 0.4 μL/min in the portable continuous flow PCR (CFPCR) device. To our knowledge, our group is the first to introduce Arduino boards into the heat control and sample pumping modules for a CFPCR device.
Collapse
Affiliation(s)
- Shyang-Chwen Sheu
- Department of Food Science, National Pingtung University of Science and Technology, 1, Shuefu Road, Neipu, Pingtung 91201, Taiwan
| | - Yi-Syuan Song
- Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, 1, Shuefu Road, Neipu, Pingtung 91201, Taiwan
| | - Jyh-Jian Chen
- Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, 1, Shuefu Road, Neipu, Pingtung 91201, Taiwan
| |
Collapse
|
3
|
Han X, Liu Y, Yin J, Yue M, Mu Y. Microfluidic devices for multiplexed detection of foodborne pathogens. Food Res Int 2021; 143:110246. [PMID: 33992358 DOI: 10.1016/j.foodres.2021.110246] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 02/02/2021] [Accepted: 02/16/2021] [Indexed: 01/10/2023]
Abstract
The global burden of foodborne diseases is substantial and foodborne pathogens are the major cause for human illnesses. In order to prevent the spread of foodborne pathogens, detection methods are constantly being updated towards rapid, portable, inexpensive, and multiplexed on-site detection. Due to the nature of the small size and low volume, microfluidics has been applied to rapid, time-saving, sensitive, and portable devices to meet the requirements of on-site detection. Simultaneous detection of multiple pathogens is another key parameter to ensure food safety. Multiplexed detection technology, including microfluidic chip design, offers a new opportunity to achieve this goal. In this review, we introduced several sample preparation and corresponding detection methods on microfluidic devices for multiplexed detection of foodborne pathogens. In the sample preparation section, methods of cell capture and enrichment, as well as nucleic acid sample preparation, were described in detail, and in the section of detection methods, amplification, immunoassay, surface plasmon resonance and impedance spectroscopy were exhaustively illustrated. The limitations and advantages of all available experimental options were also summarized and discussed in order to form a comprehensive understanding of cutting-edge technologies and provide a comparative assessment for future investigation and in-field application.
Collapse
Affiliation(s)
- Xiaoying Han
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China; College of Life Sciences, Zhejiang University, Hangzhou 310058, PR China
| | - Yuanhui Liu
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China; College of Life Sciences, Zhejiang University, Hangzhou 310058, PR China
| | - Juxin Yin
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China
| | - Min Yue
- Department of Veterinary Medicine & Institute of Preventive Veterinary Sciences, Zhejiang University College of Animal Sciences, Hangzhou 310058, PR China; State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, National Clinical Research Center for Infectious Diseases, National Medical Center for Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003, PR China; Hainan Institute of Zhejiang University, Sanya 572025, PR China.
| | - Ying Mu
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China.
| |
Collapse
|
4
|
Parallel-processing continuous-flow device for optimization-free polymerase chain reaction. Anal Bioanal Chem 2016; 408:6751-8. [DOI: 10.1007/s00216-016-9798-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Revised: 07/10/2016] [Accepted: 07/14/2016] [Indexed: 01/29/2023]
|
5
|
Zhang C, Wang H, Xing D. Multichannel oscillatory-flow multiplex PCR microfluidics for high-throughput and fast detection of foodborne bacterial pathogens. Biomed Microdevices 2012; 13:885-97. [PMID: 21691814 DOI: 10.1007/s10544-011-9558-y] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
In the field of continuous-flow PCR, the amplification throughput in a single reaction solution is low and the single-plex PCR is often used. In this work, we reported a flow-based multiplex PCR microfluidic system capable of performing high-throughput and fast DNA amplification for detection of foodborne bacterial pathogens. As a demonstration, the mixture of DNA targets associated with three different foodborne pathogens was included in a single PCR solution. Then, the solution flowed through microchannels incorporated onto three temperature zones in an oscillatory manner. The effect factors of this oscillatory-flow multiplex PCR thermocycling have been demonstrated, including effects of polymerase concentration, cycling times, number of cycles, and DNA template concentration. The experimental results have shown that the oscillatory-flow multiplex PCR, with a volume of only 5 μl, could be completed in about 13 min after 35 cycles (25 cycles) at 100 μl/min (70 μl/min), which is about one-sixth of the time required on the conventional machine (70 min). By using the presently designed DNA sample model, the minimum target concentration that could be detected at 30 μl/min was 9.8 × 10(-2) ng/μl (278-bp, S. enterica), 11.2 × 10(-2) ng/μl (168-bp, E. coli O157: H7), and 2.88 × 10(-2) ng/μl (106-bp, L. monocytogenes), which corresponds to approximately 3.72 × 10(4) copies/μl, 3.58 × 10(4) copies/μl, and 1.79 × 10(4) copies/μl, respectively. This level of speed and sensitivity is comparable to that achievable in most other continuous-flow PCR systems. In addition, the four individual channels were used to achieve multi-target PCR analysis of three different DNA samples from different food sources in parallel, thereby achieving another level of multiplexing.
Collapse
Affiliation(s)
- Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| | | | | |
Collapse
|
6
|
Li Y, Zhang C, Xing D. Integrated microfluidic reverse transcription-polymerase chain reaction for rapid detection of food- or waterborne pathogenic rotavirus. Anal Biochem 2011; 415:87-96. [PMID: 21570946 DOI: 10.1016/j.ab.2011.04.026] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2010] [Revised: 04/13/2011] [Accepted: 04/15/2011] [Indexed: 10/18/2022]
|
7
|
Peham JR, Vellekoop MJ, Nöhammer C, Wiesinger-Mayr H. PCR Product Detector with LED-Photodiode Fluorescence Sensing in a Nanoliter Flow-Cell for the High-Throughput Detection of Double-Stranded DNA. ACTA ACUST UNITED AC 2011. [DOI: 10.1016/j.proeng.2011.12.230] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|