1
|
Recker F, Remmersmann L, Jost E, Jimenez-Cruz J, Haverkamp N, Gembruch U, Strizek B, Schäfer VS. Development of a 3D-printed nuchal translucency model: a pilot study for prenatal ultrasound training. Arch Gynecol Obstet 2024; 310:2055-2064. [PMID: 38796557 PMCID: PMC11393208 DOI: 10.1007/s00404-024-07561-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/14/2024] [Indexed: 05/28/2024]
Abstract
BACKGROUND We used two 3D ultrasound volumes of fetal heads at 13 weeks to create live-size 3D-printed phantoms with a view to training or assessment of diagnostic abilities for normal and abnormal nuchal translucency measurements. The phantoms are suitable for use in a water bath, imitating a real-life exam. They were then used to study measurement accuracy and reproducibility in examiners of different skill levels. METHODS Ultrasound scans of a 13 + 0-week fetus were processed using 3D Slicer software, producing a stereolithography file for 3D printing. The model, crafted in Autodesk Fusion360™, adhered to FMF guidelines for NT dimensions (NT 2.3 mm). Additionally, a model with pathologic NT was designed (NT 4.2 mm). Printing was performed via Formlabs Form 3® printer using High Temp Resin V2. The externally identical looking 3D models were embedded in water-filled condoms for ultrasound examination. Eight specialists of varying expertise levels conducted five NT measurements for each model, classifying them in physiological and abnormal models. RESULTS Classification of the models in physiological or abnormal NT resulted in a detection rate of 100%. Average measurements for the normal NT model and the increased NT model were 2.27 mm (SD ± 0.38) and 4.165 mm (SD ± 0.51), respectively. The interrater reliability was calculated via the intraclass correlation coefficient (ICC) which yielded a result of 0.883, indicating robust agreement between the raters. Cost-effectiveness analysis demonstrated the economical nature of the 3D printing process. DISCUSSION This study underscores the potential of 3D printed fetal models for enhancing ultrasound training through high inter-rater reliability, consistency across different expert levels, and cost-effectiveness. Limitations, including population variability and direct translation to clinical outcomes, warrant further exploration. The study contributes to ongoing discussions on integrating innovative technologies into medical education, offering a practical and economical method to acquire, refine and revise diagnostic skills in prenatal ultrasound. Future research should explore broader applications and long-term economic implications, paving the way for transformative advancements in medical training and practice.
Collapse
Affiliation(s)
- Florian Recker
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
| | - Laura Remmersmann
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany
| | - Elena Jost
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany
| | - Jorge Jimenez-Cruz
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany
| | - Nicolas Haverkamp
- Office of Academic Affairs, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany
| | - Ulrich Gembruch
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany
| | - Brigitte Strizek
- Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany
| | - Valentin S Schäfer
- Department of Rheumatology and Clinical Immunology, Clinic of Internal Medicine III, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
2
|
Belsheva M, Safonova L, Shkarubo A. Sensitivity of Frequency Domain Near Infrared Spectroscopy for Neurovascular Structure Detection in Biotissue Volume: Numerical Modeling Results. JOURNAL OF BIOPHOTONICS 2024:e202400291. [PMID: 39257224 DOI: 10.1002/jbio.202400291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Revised: 08/16/2024] [Accepted: 08/20/2024] [Indexed: 09/12/2024]
Abstract
Through numerical modeling, it has been determined that near infrared spectroscopy with a frequency domain approach can detect neurovascular structures with diameters from 0.5 mm at source-detector distances of 5-8 mm, depending on optical parameters and technical implementation of the method. Among the five classical machine learning methods considered, quadratic discriminant analysis is the most effective for detection. Furthermore, it has been demonstrated that the use of a photomultiplier tube and the registration of both amplitude and phase signal components exhibit the highest sensitivity. Spectroscopy can rival modern ultrasound for detecting arterial vessels. A cross-shaped probe configuration improves sensitivity, and the ratio of reduced scattering coefficient values at different wavelengths is informative for blood-filled vessel detection. These findings are consistent with and significantly extend previous experimental in vivo and in situ studies and could be valuable for intraoperative diagnostic tasks, particularly in neurosurgery.
Collapse
Affiliation(s)
- Mariia Belsheva
- Department of Biomedical Engineering, Bauman Moscow State Technical University, Moscow, Russia
| | - Larisa Safonova
- Department of Biomedical Engineering, Bauman Moscow State Technical University, Moscow, Russia
| | - Alexey Shkarubo
- Federal State Autonomous Institution "N. N. Burdenko National Medical Research Center of Neurosurgery" of the Ministry of Health of the Russian Federation, Moscow, Russia
| |
Collapse
|
3
|
Deane AS, Byers KT. A review of the ethical considerations for the use of 3D printed materials in medical and allied health education and a proposed collective path forward. ANATOMICAL SCIENCES EDUCATION 2024; 17:1164-1173. [PMID: 39001638 DOI: 10.1002/ase.2483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 06/11/2024] [Accepted: 06/13/2024] [Indexed: 08/30/2024]
Abstract
3D scanning and printing technologies are quickly evolving and offer great potential for use in gross anatomical education. The use of human body donors to create digital scans and 3D printed models raises ethical concerns about donor informed consent, potential commodification, and access to and storage of potentially identifiable anatomical reproductions. This paper reviews available literature describing ethical implications for the application of these emerging technologies, existing published best practices for managing and sharing 2D imaging, and current adherence to these best practices by academic body donation programs. We conclude that informed consent is paramount for all uses of human donor and human donor-derived materials and that currently there is considerable diversity in adherence to established best practices for the management and sharing of 3D digital content derived from human donors. We propose a new and simplified framework for categorizing donor-derived teaching materials and the corresponding level of consent required for digital sharing. This framework proposes an equivalent minimum level of specific consent for human donor and human donor-derived materials relative to generalized, nonidentical teaching materials (i.e., artificial plastic models). Likewise, we propose that the collective path forward should involve the creation of a centralized, secure repository for digital human donor 3D content as a mechanism for accumulating, regulating, and controlling the distribution of properly consented human donor-derived 3D digital content that will also increase the availability of ethically created human-derived teaching materials while discouraging commodification.
Collapse
Affiliation(s)
- Andrew S Deane
- Department of Anatomy, Cell Biology & Physiology, Indiana University School of Medicine, Indianapolis, Indiana, USA
- Department of Anthropology, Indiana University, Indianapolis, Indiana, USA
- Centre for the Exploration of the Deep Human Journey, University of Witwatersrand, Johannesburg, South Africa
| | - Kelsey T Byers
- University of California, Office of the President Anatomical Donation Program, Oakland, CA, USA
| |
Collapse
|
4
|
Iqbal J, Zafar Z, Skandalakis G, Kuruba V, Madan S, Kazim SF, A Bowers C. Recent advances of 3D-printing in spine surgery. Surg Neurol Int 2024; 15:297. [PMID: 39246777 PMCID: PMC11380890 DOI: 10.25259/sni_460_2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 07/27/2024] [Indexed: 09/10/2024] Open
Abstract
Background The emerging use of three-dimensional printing (3DP) offers improved surgical planning and personalized care. The use of 3DP technology in spinal surgery has several common applications, including models for preoperative planning, biomodels, surgical guides, implants, and teaching tools. Methods A literature review was conducted to examine the current use of 3DP technology in spinal surgery and identify the challenges and limitations associated with its adoption. Results The review reveals that while 3DP technology offers the benefits of enhanced stability, improved surgical outcomes, and the feasibility of patient-specific solutions in spinal surgeries, several challenges remain significant impediments to widespread adoption. The obvious expected limitation is the high cost associated with implementing and maintaining a 3DP facility and creating customized patient-specific implants. Technological limitations, including the variability between medical imaging and en vivo surgical anatomy, along with the reproduction of intricate high-fidelity anatomical detail, pose additional challenges. Finally, the lack of comprehensive clinical monitoring, inadequate sample sizes, and high-quality scientific evidence all limit our understanding of the full scope of 3DP's utility in spinal surgery and preclude widespread adoption and implementation. Conclusion Despite the obvious challenges and limitations, ongoing research and development efforts are expected to address these issues, improving the accessibility and efficacy of 3DP technology in spinal surgeries. With further advancements, 3DP technology has the potential to revolutionize spinal surgery by providing personalized implants and precise surgical planning, ultimately improving patient outcomes and surgical efficiency.
Collapse
Affiliation(s)
- Javed Iqbal
- Department of Neurosurgery, King Edward Medical University, Lahore, Pakistan
| | - Zaitoon Zafar
- Department of Biotechnology, University of San Francisco, San Francisco, California, United States
| | - Georgios Skandalakis
- Department of Neurosurgery, University of New Mexico, Albuquerque, New Mexico, United States
| | | | - Shreya Madan
- Department of Neurosurgery, Desert Mountain High School, Scottsdale, Arizona, United States
| | - Syed Faraz Kazim
- Department of Neurosurgery, University of New Mexico Hospital, Albuquerque, New Mexico, United States
| | - Christian A Bowers
- Department of Neurosurgery, University of New Mexico Hospital, Albuquerque, New Mexico, United States
| |
Collapse
|
5
|
Neri I, Cercenelli L, Marcuccio M, Lodi S, Koufi FD, Fazio A, Marvi MV, Marcelli E, Billi AM, Ruggeri A, Tarsitano A, Manzoli L, Badiali G, Ratti S. Dissecting human anatomy learning process through anatomical education with augmented reality: AEducAR 2.0, an updated interdisciplinary study. ANATOMICAL SCIENCES EDUCATION 2024; 17:693-711. [PMID: 38520153 DOI: 10.1002/ase.2389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/22/2024] [Accepted: 01/22/2024] [Indexed: 03/25/2024]
Abstract
Anatomical education is pivotal for medical students, and innovative technologies like augmented reality (AR) are transforming the field. This study aimed to enhance the interactive features of the AEducAR prototype, an AR tool developed by the University of Bologna, and explore its impact on human anatomy learning process in 130 second-year medical students at the International School of Medicine and Surgery of the University of Bologna. An interdisciplinary team of anatomists, maxillofacial surgeons, biomedical engineers, and educational scientists collaborated to ensure a comprehensive understanding of the study's objectives. Students used the updated version of AEducAR, named AEducAR 2.0, to study three anatomical topics, specifically the orbit zone, facial bones, and mimic muscles. AEducAR 2.0 offered two learning activities: one explorative and one interactive. Following each activity, students took a test to assess learning outcomes. Students also completed an anonymous questionnaire to provide background information and offer their perceptions of the activity. Additionally, 10 students participated in interviews for further insights. The results demonstrated that AEducAR 2.0 effectively facilitated learning and students' engagement. Students totalized high scores in both quizzes and declared to have appreciated the interactive features that were implemented. Moreover, interviews shed light on the interesting topic of blended learning. In particular, the present study suggests that incorporating AR into medical education alongside traditional methods might prove advantageous for students' academic and future professional endeavors. In this light, this study contributes to the growing research emphasizing the potential role of AR in shaping the future of medical education.
Collapse
Affiliation(s)
- Irene Neri
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Laura Cercenelli
- eDIMES Lab-Laboratory of Bioengineering, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Massimo Marcuccio
- Department of Educational Science "Giovanni Maria Bertin", University of Bologna, Bologna, Italy
| | - Simone Lodi
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Foteini-Dionysia Koufi
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Antonietta Fazio
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Maria Vittoria Marvi
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Emanuela Marcelli
- eDIMES Lab-Laboratory of Bioengineering, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Anna Maria Billi
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Alessandra Ruggeri
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Achille Tarsitano
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
- Department of Maxillo-Facial Surgery, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Lucia Manzoli
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Giovanni Badiali
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
- Department of Maxillo-Facial Surgery, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Stefano Ratti
- Cellular Signalling Laboratory, Anatomy Center, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| |
Collapse
|
6
|
Chytas D, Noussios G, Salmas M, Demesticha T, Vasiliadis AV, Troupis T. The effectiveness of three-dimensional printing in undergraduate and postgraduate anatomy education: A review of reviews. Morphologie 2024; 108:100759. [PMID: 38215686 DOI: 10.1016/j.morpho.2023.100759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/09/2023] [Accepted: 12/12/2023] [Indexed: 01/14/2024]
Abstract
PURPOSE Several reviews and meta-analyses about the value of three-dimensional (3D) printing in anatomy education have been published in the last years, with variable-and sometimes confusing- outcomes. We performed a review of those reviews, in order to shed light on the results concerning the effectiveness of 3D printing in anatomy education, compared to specific traditional methods and other technologies. METHODS The electronic databases PubMed, ERIC and Cochrane library were searched for reviews or meta-analyses with purpose to investigate the effectiveness of 3D printing in undergraduate and postgraduate anatomy education. RESULTS Seven papers were included: four systematic reviews with meta-analysis, one narrative, one scoping and one systematic review. Overall, it has been shown that 3D printing is more effective than two-dimensional (2D) images for undergraduate health science students, but not for medical residents. Also, it seems to be more effective than 2D methods for teaching anatomy of some relatively complex structures, such as the nervous system. However, there is generally lack of evidence about the effectiveness of 3D printing in comparison with other 3D visualization methods. CONCLUSIONS For students, the effectiveness of 3D printing in anatomy education is higher than 2D methods. There is need for studies to investigate the effectiveness of 3D printing in comparison with other 3D visualization methods, such as cadaveric dissection, prosection and virtual reality. There is also need for research to explore if 3D printing is effective as a supplementary tool in a blended anatomy learning approach.
Collapse
Affiliation(s)
- D Chytas
- Department of Physiotherapy, Basic Sciences Laboratory, University of Peloponnese, 20, Plateon Street, 23100 Sparta, Greece; European University of Cyprus, 6, Diogenous Street, 2404 Engomi, Nicosia, Cyprus.
| | - G Noussios
- Department of Physical Education and Sports Sciences of Serres, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - M Salmas
- Department of Anatomy, School of Medicine, National and Kapodistrian University of Athens, 75, Mikras Asias Street, 11527 Athens, Greece
| | - T Demesticha
- Department of Anatomy, School of Medicine, National and Kapodistrian University of Athens, 75, Mikras Asias Street, 11527 Athens, Greece
| | - A V Vasiliadis
- Department of Orthopaedic Surgery, Sports Trauma Unit, St. Luke's Hospital, Panorama, 55236 Thessaloniki, Greece
| | - T Troupis
- Department of Anatomy, School of Medicine, National and Kapodistrian University of Athens, 75, Mikras Asias Street, 11527 Athens, Greece
| |
Collapse
|
7
|
Rahmani R, Santangelo G, Jalal MI, Catanzaro M, Samodal J, Bender MT, Stone JJ. A Simple 3D Printed Model for Intracranial Vascular Anastomosis Practice and the Rochester Bypass Training Score. Oper Neurosurg (Hagerstown) 2024; 26:341-345. [PMID: 37815226 DOI: 10.1227/ons.0000000000000931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 08/04/2023] [Indexed: 10/11/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Surgical simulation models in cranial neurosurgery are needed to allow affordable, accessible, and validated practice in resident education. Current bypass anastomosis practice models revolve around basic tube tying or complex animal and 3-dimensional models. This study sought to design and validate a 3-dimensional printed model for intracranial anastomosis training. METHODS A computer-aided design (CAD) generic skull was uploaded into Meshmixer (v.3.5), and a 55-mm opening was created on the right side, mimicking a standard orbitozygomatic craniotomy. The model was rotated 15° upward and 35° left, before a 10-mm square frame was added 80-mm deep to the right orbit. The CAD model was uploaded to GrabCAD and printed using a J750 PolyJet 3D printer before being paired with a vascular anastomosis kit. The model was validated with standardized assessments of residents and attendings by simulating an "M2 to P2" bypass. The Rochester Bypass Training Score (RBTS) was created to assess bypass patency, back wall suturing, and suture quality. Postsimulation survey data regarding the realism and usefulness of the simulation were collected. RESULTS Five junior residents (Postgraduate Year 1-4), 3 senior residents (Postgraduate Year 5-7), and 2 attendings were participated. The mean operative time in minutes was as follows: junior residents 78, senior residents 33, and attendings 50. The RBTS means were as follows: junior residents 2.4, senior residents 4.0, and attendings 5.0. Participants agreed that the model was realistic, useful for improving operative technique, and would increase comfort in bypass procedures. There are a few different printing options, varying in model infill and printing material used. For this experiment, a mix of Vero plastics were used totaling $309.09 per model; however, using the more common printing material polylactic acid brings the cost to $17.27 for a comparable model. CONCLUSION This study presents an affordable, realistic, and educational intracranial vascular anastomosis simulator and introduces the RBTS for assessment.
Collapse
Affiliation(s)
- Redi Rahmani
- Department of Neurosurgery, University of Rochester Medical Center, Rochester , New York, USA
| | - Gabrielle Santangelo
- Department of Neurosurgery, University of Rochester Medical Center, Rochester , New York, USA
| | - Muhammad I Jalal
- University of Rochester, School of Medicine and Dentistry, Rochester , New York, USA
| | - Michael Catanzaro
- Department of Plastic Surgery, University of Rochester Medical Center, Rochester , New York, USA
| | - Joshua Samodal
- Department of Neurosurgery, University of Rochester Medical Center, Rochester , New York, USA
| | - Matthew T Bender
- Department of Neurosurgery, University of Rochester Medical Center, Rochester , New York, USA
| | - Jonathan J Stone
- Department of Neurosurgery, University of Rochester Medical Center, Rochester , New York, USA
| |
Collapse
|
8
|
Foresti R, Fornasari A, Bianchini Massoni C, Mersanne A, Martini C, Cabrini E, Freyrie A, Perini P. Surgical Medical Education via 3D Bioprinting: Modular System for Endovascular Training. Bioengineering (Basel) 2024; 11:197. [PMID: 38391683 PMCID: PMC10886183 DOI: 10.3390/bioengineering11020197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/11/2024] [Accepted: 02/17/2024] [Indexed: 02/24/2024] Open
Abstract
There is currently a shift in surgical training from traditional methods to simulation-based approaches, recognizing the necessity of more effective and controlled learning environments. This study introduces a completely new 3D-printed modular system for endovascular surgery training (M-SET), developed to allow various difficulty levels. Its design was based on computed tomography angiographies from real patient data with femoro-popliteal lesions. The study aimed to explore the integration of simulation training via a 3D model into the surgical training curriculum and its effect on their performance. Our preliminary study included 12 volunteer trainees randomized 1:1 into the standard simulation (SS) group (3 stepwise difficulty training sessions) and the random simulation (RS) group (random difficulty of the M-SET). A senior surgeon evaluated and timed the final training session. Feedback reports were assessed through the Student Satisfaction and Self-Confidence in Learning Scale. The SS group completed the training sessions in about half time (23.13 ± 9.2 min vs. 44.6 ± 12.8 min). Trainees expressed high satisfaction with the training program supported by the M-SET. Our 3D-printed modular training model meets the current need for new endovascular training approaches, offering a customizable, accessible, and effective simulation-based educational program with the aim of reducing the time required to reach a high level of practical skills.
Collapse
Affiliation(s)
- Ruben Foresti
- Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126 Parma, Italy
- Center of Excellence for Toxicological Research (CERT), University of Parma, 43126 Parma, Italy
- Italian National Research Council, Institute of Materials for Electronics and Magnetism (CNR-IMEM), 43124 Parma, Italy
| | - Anna Fornasari
- Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy
| | - Claudio Bianchini Massoni
- Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy
| | - Arianna Mersanne
- Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy
| | - Chiara Martini
- Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126 Parma, Italy
- Diagnostic Department, University-Hospital of Parma, Via Gramsci 14, 43126 Parma, Italy
| | - Elisa Cabrini
- Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy
| | - Antonio Freyrie
- Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126 Parma, Italy
- Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy
| | - Paolo Perini
- Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126 Parma, Italy
- Vascular Surgery, Cardio-Thoracic and Vascular Department, University-Hospital of Parma, 43126 Parma, Italy
| |
Collapse
|
9
|
González-López P, Kuptsov A, Gómez-Revuelta C, Fernández-Villa J, Abarca-Olivas J, Daniel RT, Meling TR, Nieto-Navarro J. The Integration of 3D Virtual Reality and 3D Printing Technology as Innovative Approaches to Preoperative Planning in Neuro-Oncology. J Pers Med 2024; 14:187. [PMID: 38392620 PMCID: PMC10890029 DOI: 10.3390/jpm14020187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 01/17/2024] [Accepted: 01/29/2024] [Indexed: 02/24/2024] Open
Abstract
Our study explores the integration of three-dimensional (3D) virtual reality (VR) and 3D printing in neurosurgical preoperative planning. Traditionally, surgeons relied on two-dimensional (2D) imaging for complex neuroanatomy analyses, requiring significant mental visualization. Fortunately, nowadays advanced technology enables the creation of detailed 3D models from patient scans, utilizing different software. Afterwards, these models can be experienced through VR systems, offering comprehensive preoperative rehearsal opportunities. Additionally, 3D models can be 3D printed for hands-on training, therefore enhancing surgical preparedness. This technological integration transforms the paradigm of neurosurgical planning, ensuring safer procedures.
Collapse
Affiliation(s)
- Pablo González-López
- Department of Neurosurgery, Hospital General Universitario, 03010 Alicante, Spain
| | - Artem Kuptsov
- Department of Neurosurgery, Hospital General Universitario, 03010 Alicante, Spain
| | | | | | - Javier Abarca-Olivas
- Department of Neurosurgery, Hospital General Universitario, 03010 Alicante, Spain
| | - Roy T Daniel
- Centre Hospitalier Universitaire Vaudois, 1005 Lausanne, Switzerland
| | - Torstein R Meling
- Department of Neurosurgery, Rigshospitalet, 92100 Copenhagen, Denmark
| | - Juan Nieto-Navarro
- Department of Neurosurgery, Hospital General Universitario, 03010 Alicante, Spain
| |
Collapse
|
10
|
Wood L, Ahmed Z. Does using 3D printed models for pre-operative planning improve surgical outcomes of foot and ankle fracture fixation? A systematic review and meta-analysis. Eur J Trauma Emerg Surg 2024; 50:21-35. [PMID: 36418394 PMCID: PMC10924018 DOI: 10.1007/s00068-022-02176-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 11/11/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE The systematic review aims to establish the value of using 3D printing-assisted pre-operative planning, compared to conventional planning, for the operative management of foot and ankle fractures. METHODS The systematic review was performed according to PRISMA guidelines. Two authors performed searches on three electronic databases. Studies were included if they conformed to pre-established eligibility criteria. Primary outcome measures included intraoperative blood loss, operation duration, and fluoroscopy time. The American orthopaedic foot and ankle score (AOFAS) was used as a secondary outcome. Quality assessment was completed using the Cochrane RoB2 form and a meta-analysis was performed to assess heterogeneity. RESULTS Five studies met the inclusion and exclusion criteria and were eventually included in the review. A meta-analysis established that using 3D printed models for pre-operative planning resulted in a significant reduction in operation duration (mean difference [MD] = - 23.52 min, 95% CI [- 39.31, - 7.74], p = 0.003), intraoperative blood loss (MD = - 30.59 mL, 95% CI [- 46.31, - 14.87], p = 0.0001), and number of times fluoroscopy was used (MD = - 3.20 times, 95% CI [- 4.69, - 1.72], p < 0.0001). Using 3D printed models also significantly increased AOFAS score results (MD = 2.24, 95% CI [0.69, 3.78], p = 0.005), demonstrating improved ankle health. CONCLUSION The systematic review provides promising evidence that 3D printing-assisted surgery significantly improves treatment for foot and ankle fractures in terms of operation duration, intraoperative blood loss, number of times fluoroscopy was used intraoperatively, and improved overall ankle health as measured by the AOFAS score.
Collapse
Affiliation(s)
- Lea Wood
- College of Medical and Dental Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - Zubair Ahmed
- College of Medical and Dental Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK.
- Neuroscience and Ophthalmology, Institute of Inflammation and Ageing, College of Medical and Dental Science, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK.
- Centre for Trauma Sciences Research, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK.
| |
Collapse
|
11
|
Shabbak A, Masoumkhani F, Fallah A, Amani-Beni R, Mohammadpour H, Shahbazi T, Bakhshi A. 3D Printing for Cardiovascular Surgery and Intervention: A Review Article. Curr Probl Cardiol 2024; 49:102086. [PMID: 37716537 DOI: 10.1016/j.cpcardiol.2023.102086] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 09/12/2023] [Indexed: 09/18/2023]
Abstract
3D printing technology can be applied to practically every aspect of modern life, fulfilling the needs of people from various backgrounds. The utilization of 3D printing in the context of adult heart disease can be succinctly categorized into 3 primary domains: preoperative strategizing or simulation, medical instruction, and clinical consultations. 3D-printed model utilization improves surgical planning and intraoperative decision-making and minimizes surgical risks, and it has demonstrated its efficacy as an innovative educational tool for aspiring surgeons with limited practical exposure. Despite all the applications of 3D printing, it has not yet been shown to improve long-term outcomes, including safety. There are no data on the outcomes of controlled trials available. To appropriately diagnose heart disease, 3D-printed models of the heart can provide a better understanding of the intracardiac anatomy and provide all the information needed for operative planning. Experientially, 3D printing provides a wide range of perceptions for understanding lower extremity arteries' spatial geometry and anatomical features of pathology. Practicing cardiac surgery processes using objects printed using 3D imaging data can become the norm rather than the exception, leading to improved accuracy and quality of treatment. This study aimed to review the various applications of 3D printing technology in cardiac surgery and intervention.
Collapse
Affiliation(s)
- Ali Shabbak
- Research Committee, School of Medicine, Guilan University of Medical Science, Rasht, Iran
| | - Fateme Masoumkhani
- Department of cardiology, Mousavi Hospital, Zanjan University of Medical Sciences, Zanjan, Iran
| | - Amir Fallah
- Research Committee, School of Medicine, Guilan University of Medical Science, Rasht, Iran
| | - Reza Amani-Beni
- School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Hanieh Mohammadpour
- Research Committee, School of Medicine, Guilan University of Medical Science, Rasht, Iran
| | - Taha Shahbazi
- Neurosurgery Research Group (NRG), Student Research Committee, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Arash Bakhshi
- Remember of Research Committee, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran.
| |
Collapse
|
12
|
Vollmer A, Saravi B, Breitenbuecher N, Mueller-Richter U, Straub A, Šimić L, Kübler A, Vollmer M, Gubik S, Volland J, Hartmann S, Brands RC. Realizing in-house algorithm-driven free fibula flap set up within 24 hours: a pilot study evaluating accuracy with open-source tools. Front Surg 2023; 10:1321217. [PMID: 38162091 PMCID: PMC10755006 DOI: 10.3389/fsurg.2023.1321217] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 12/04/2023] [Indexed: 01/03/2024] Open
Abstract
Objective This study aims to critically evaluate the effectiveness and accuracy of a time safing and cost-efficient open-source algorithm for in-house planning of mandibular reconstructions using the free osteocutaneous fibula graft. The evaluation focuses on quantifying anatomical accuracy and assessing the impact on ischemia time. Methods A pilot study was conducted, including patients who underwent in-house planned computer-aided design and manufacturing (CAD/CAM) of free fibula flaps between 2021 and 2023. Out of all patient cases, we included all with postoperative 3D imaging in the study. The study utilized open-source software tools for the planning step, and three-dimensional (3D) printing techniques. The Hausdorff distance and Dice coefficient metrics were used to evaluate the accuracy of the planning procedure. Results The study assessed eight patients (five males and three females, mean age 61.75 ± 3.69 years) with different diagnoses such as osteoradionecrosis and oral squamous cell carcinoma. The average ischemia time was 68.38 ± 27.95 min. For the evaluation of preoperative planning vs. the postoperative outcome, the mean Hausdorff Distance was 1.22 ± 0.40. The Dice Coefficients yielded a mean of 0.77 ± 0.07, suggesting a satisfactory concordance between the planned and postoperative states. Dice Coefficient and Hausdorff Distance revealed significant correlations with ischemia time (Spearman's rho = -0.810, p = 0.015 and Spearman's rho = 0.762, p = 0.028, respectively). Linear regression models adjusting for disease type further substantiated these findings. Conclusions The in-house planning algorithm not only achieved high anatomical accuracy, as reflected by the Dice Coefficients and Hausdorff Distance metrics, but this accuracy also exhibited a significant correlation with reduced ischemia time. This underlines the critical role of meticulous planning in surgical outcomes. Additionally, the algorithm's open-source nature renders it cost-efficient, easy to learn, and broadly applicable, offering promising avenues for enhancing both healthcare affordability and accessibility.
Collapse
Affiliation(s)
- Andreas Vollmer
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Babak Saravi
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
- Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA,United States
| | - Niko Breitenbuecher
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Urs Mueller-Richter
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Anton Straub
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Luka Šimić
- Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, Osijek, Croatia
| | - Alexander Kübler
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Michael Vollmer
- Department of Oral and Maxillofacial Surgery, Tuebingen University Hospital, Tuebingen, Germany
| | - Sebastian Gubik
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Julian Volland
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Stefan Hartmann
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Roman C. Brands
- Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Würzburg, Würzburg, Germany
| |
Collapse
|
13
|
Ma L, Yu S, Xu X, Moses Amadi S, Zhang J, Wang Z. Application of artificial intelligence in 3D printing physical organ models. Mater Today Bio 2023; 23:100792. [PMID: 37746667 PMCID: PMC10511479 DOI: 10.1016/j.mtbio.2023.100792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/01/2023] [Accepted: 09/08/2023] [Indexed: 09/26/2023] Open
Abstract
Artificial intelligence (AI) and 3D printing will become technologies that profoundly impact humanity. 3D printing of patient-specific organ models is expected to replace animal carcasses, providing scenarios that simulate the surgical environment for preoperative training and educating patients to propose effective solutions. Due to the complexity of 3D printing manufacturing, it is still used on a small scale in clinical practice, and there are problems such as the low resolution of obtaining MRI/CT images, long consumption time, and insufficient realism. AI has been effectively used in 3D printing as a powerful problem-solving tool. This paper introduces 3D printed organ models, focusing on the idea of AI application in 3D printed manufacturing of organ models. Finally, the potential application of AI to 3D-printed organ models is discussed. Based on the synergy between AI and 3D printing that will benefit organ model manufacturing and facilitate clinical preoperative training in the medical field, the use of AI in 3D-printed organ model making is expected to become a reality.
Collapse
Affiliation(s)
- Liang Ma
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310000, China
- Zhejiang Provincial People’s Hospital, Hangzhou, Zhejiang, 310000, China
| | - Shijie Yu
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310000, China
- Zhejiang Provincial People’s Hospital, Hangzhou, Zhejiang, 310000, China
| | - Xiaodong Xu
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310000, China
- Zhejiang Provincial People’s Hospital, Hangzhou, Zhejiang, 310000, China
| | - Sidney Moses Amadi
- International Education College, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, 310000, China
| | - Jing Zhang
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Zhifei Wang
- Zhejiang Provincial People’s Hospital, Hangzhou, Zhejiang, 310000, China
| |
Collapse
|
14
|
Zeller AN, Goetze E, Thiem DGE, Bartella AK, Seifert L, Beiglboeck FM, Kröplin J, Hoffmann J, Pabst A. A survey regarding the organizational aspects and quality systems of in-house 3D printing in oral and maxillofacial surgery in Germany. Oral Maxillofac Surg 2023; 27:661-673. [PMID: 35989406 DOI: 10.1007/s10006-022-01109-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 08/02/2022] [Indexed: 01/15/2023]
Abstract
PURPOSE The aim of the study was to get a cross-sectional overview of the current status of specific organizational procedures, quality control systems, and standard operating procedures for the use of three-dimensional (3D) printing to assist in-house workflow using additive manufacturing in oral and maxillofacial surgery (OMFS) in Germany. METHODS An online questionnaire including dynamic components containing 16-29 questions regarding specific organizational aspects, process workflows, quality controls, documentation, and the respective backgrounds in 3D printing was sent to OMF surgeons in university and non-university hospitals as well as private practices with and without inpatient treatment facilities. Participants were recruited from a former study population regarding 3D printing; all participants owned a 3D printer and were registered with the German Association of Oral and Maxillofacial Surgery. RESULTS Sixty-seven participants answered the questionnaires. Of those, 20 participants ran a 3D printer in-unit. Quality assurance measures were performed by 13 participants and underlying processes by 8 participants, respectively. Standard operating procedures regarding computer-aided design and manufacturing, post-processing, use, or storage of printed goods were non-existent in most printing units. Data segmentation as well as computer-aided design and manufacturing were conducted by a medical doctor in most cases (n = 19, n = 18, n = 8, respectively). Most participants (n = 8) stated that "medical device regulations did not have any influence yet, but an adaptation of the processes is planned for the future." CONCLUSION The findings demonstrated significant differences in 3D printing management in OMFS, especially concerning process workflows, quality control, and documentation. Considering the ever-increasing regulations for medical devices, there might be a necessity for standardized 3D printing recommendations and regulations in OMFS.
Collapse
Affiliation(s)
- Alexander-N Zeller
- Department of Oral and Maxillofacial Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | - Elisabeth Goetze
- Department of Oral and Maxillofacial Surgery, University Hospital Erlangen, Glückstr. 11, 91054, Erlangen, Germany
| | - Daniel G E Thiem
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Alexander K Bartella
- Department of Oral and Maxillofacial Surgery, University Hospital Leipzig, Liebigstr. 12, 04103, Leipzig, Germany
| | - Lukas Seifert
- Department of Oral, Cranio Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60528, Frankfurt am Main, Germany
| | - Fabian M Beiglboeck
- Department of Oral and Maxillofacial Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149, Munster, Germany
- MAM Research Group, Department of Biomedical Engineering, University of Basel, Gewerbestr. 16, 4123, Allschwil, Switzerland
| | - Juliane Kröplin
- Department of Oral and Maxillofacial Surgery, Helios Hospital Schwerin, Wismarsche Str. 393-397, 19049, Schwerin, Germany
| | - Jürgen Hoffmann
- Department of Oral and Maxillofacial Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Andreas Pabst
- Department of Oral and Maxillofacial Surgery, Federal Armed Forces Hospital, Rübenacherstr. 170, 56072, Koblenz, Germany.
| |
Collapse
|
15
|
Soliński DG, Celer M, Dyś K, Witkiewicz W, Wiewióra M. 3D printing in the endovascular treatment of visceral artery aneurysms. Medicine (Baltimore) 2023; 102:e35844. [PMID: 37960732 PMCID: PMC10637494 DOI: 10.1097/md.0000000000035844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Accepted: 10/06/2023] [Indexed: 11/15/2023] Open
Abstract
Visceral artery aneurysms (VAAs) are vascular pathologies that are difficult to treat. The variable geometry of the vessels and the location of aneurysms render difficult their evaluation in radiological imaging studies. Less invasive endovascular procedures are increasingly used in common practice. Our aim was to test the feasibility of using 3D printing technology in the preparation of preoperative spatial models of visceral artery aneurysms and their impact on interventional treatment. In our observational study, we examined a group of patients with true aneurysms of the visceral arteries who were followed and who underwent endovascular procedures with the use of 3D prints for better imaging of vascular lesions. We analyzed the fused filament fabrication method of 3D printing and printable materials in the preparation of spatial vascular models. We confirmed that more accurate visualization and analysis of vascular anatomy could assist operators in attempting minimally invasive treatment with good results. Extending imaging studies using 3D printing models that allow for the assessment of the position, morphology and geometry of the aneurysm sac, particularly of vessel branches, could encourage surgeons to perform endovascular procedures.
Collapse
Affiliation(s)
| | - Marcin Celer
- Regional Specialist Hospital in Wroclaw, Research and Development Center, Wroclaw, Poland
| | - Krzysztof Dyś
- Regional Specialist Hospital in Wroclaw, Research and Development Center, Wroclaw, Poland
| | - Wojciech Witkiewicz
- Regional Specialist Hospital in Wroclaw, Research and Development Center, Wroclaw, Poland
| | - Maciej Wiewióra
- Department of Cardiac, Vascular and Endovascular Surgery and Transplantology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland
| |
Collapse
|
16
|
Thorn C, Ballard J, Lockhart C, Crone A, Aarvold A. The perioperative utility of 3D printed models in complex surgical care: feedback from 106 cases. Ann R Coll Surg Engl 2023; 105:747-753. [PMID: 36622212 PMCID: PMC10618040 DOI: 10.1308/rcsann.2022.0127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
INTRODUCTION 3D models are an emerging tool for surgical planning, providing an augmented method for the visualisation of a patient's anatomy. As their use increases, more data about the utility of these models is critical to inform budget allocation. This study provides the most comprehensive analysis to date for the use of 3D models in perioperative management. METHODS 3D models for complex surgical cases in NHS hospitals were delivered alongside a surgeon feedback survey. The survey on the model's utility had been designed alongside the university data analytical team and focused on five areas: surgical planning and diagnosis, economic impact, impact on intraoperative and preoperative time, effect on communication and direct impact on the patient. RESULTS There were 106 models used by 63 surgeons for complex surgical cases between May 2020 and March 2021, across multiple surgical specialties. The models were reported to have benefits in all perioperative areas, with 92.5% of responses agreeing that the 3D model was a better method for diagnosis and planning than traditional 2D techniques. Benefits were reported on preoperative planning (92.4%), economic savings due to equipment selection (54.4%), reduction in surgical time (41.5%) and surgeon-to-surgeon communication (92.6%). CONCLUSION 3D models were shown to have a wide range of benefits in a surgical setting. The reduction in surgical time could have the potential to help alleviate surgical backlogs. With more widespread use and optimisation of costs the use of 3D models could become the standard for unusual and complex surgical cases.
Collapse
Affiliation(s)
- C Thorn
- University of Southampton, UK
| | - J Ballard
- Belfast Health and Social Care Trust, Belfast, UK
| | - C Lockhart
- Belfast Health and Social Care Trust, Belfast, UK
| | - A Crone
- Belfast Health and Social Care Trust, Belfast, UK
| | - A Aarvold
- University Hospital Southampton NHS Foundation Trust, UK
| |
Collapse
|
17
|
Prabhu AV, Peterman M, Kesaria A, Samanta S, Crownover R, Lewis GD. Virtual reality technology: A potential tool to enhance brachytherapy training and delivery. Brachytherapy 2023; 22:709-715. [PMID: 37679242 DOI: 10.1016/j.brachy.2023.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/08/2023] [Accepted: 07/27/2023] [Indexed: 09/09/2023]
Affiliation(s)
- Arpan V Prabhu
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Melissa Peterman
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Anam Kesaria
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Santanu Samanta
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Richard Crownover
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Gary D Lewis
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR.
| |
Collapse
|
18
|
Song C, Min JH, Jeong WK, Kim SH, Heo JS, Han IW, Shin SH, Yoon SJ, Choi SY, Moon S. Use of individualized 3D-printed models of pancreatic cancer to improve surgeons' anatomic understanding and surgical planning. Eur Radiol 2023; 33:7646-7655. [PMID: 37231071 DOI: 10.1007/s00330-023-09756-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 03/21/2023] [Accepted: 03/27/2023] [Indexed: 05/27/2023]
Abstract
OBJECTIVES Three-dimensional (3D) printing has been increasingly used to create accurate patient-specific 3D-printed models from medical imaging data. We aimed to evaluate the utility of 3D-printed models in the localization and understanding of pancreatic cancer for surgeons before pancreatic surgery. METHODS Between March and September 2021, we prospectively enrolled 10 patients with suspected pancreatic cancer who were scheduled for surgery. We created an individualized 3D-printed model from preoperative CT images. Six surgeons (three staff and three residents) evaluated the CT images before and after the presentation of the 3D-printed model using a 7-item questionnaire (understanding of anatomy and pancreatic cancer [Q1-4], preoperative planning [Q5], and education for trainees or patients [Q6-7]) on a 5-point scale. Survey scores on Q1-5 before and after the presentation of the 3D-printed model were compared. Q6-7 assessed the 3D-printed model's effects on education compared to CT. Subgroup analysis was performed between staff and residents. RESULTS After the 3D-printed model presentation, survey scores improved in all five questions (before 3.90 vs. after 4.56, p < 0.001), with a mean improvement of 0.57‒0.93. Staff and resident scores improved after a 3D-printed model presentation (p < 0.05), except for Q4 in the resident group. The mean difference was higher among the staff than among the residents (staff: 0.50‒0.97 vs. residents: 0.27‒0.90). The scores of the 3D-printed model for education were high (trainees: 4.47 vs. patients: 4.60) compared to CT. CONCLUSION The 3D-printed model of pancreatic cancer improved surgeons' understanding of individual patients' pancreatic cancer and surgical planning. CLINICAL RELEVANCE STATEMENT The 3D-printed model of pancreatic cancer can be created using a preoperative CT image, which not only assists surgeons in surgical planning but also serves as a valuable educational resource for patients and students. KEY POINTS • A personalized 3D-printed pancreatic cancer model provides more intuitive information than CT, allowing surgeons to better visualize the tumor's location and relationship to neighboring organs. • In particular, the survey score was higher among staff who performed the surgery than among residents. • Individual patient pancreatic cancer models have the potential to be used for personalized patient education as well as resident education.
Collapse
Affiliation(s)
- Chorog Song
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Ji Hye Min
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro Gangnam-gu, Seoul, 06351, Republic of Korea.
| | - Woo Kyoung Jeong
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Seong Hyun Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jin Seok Heo
- Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - In Woong Han
- Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Sang Hyun Shin
- Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - So Jeong Yoon
- Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Seo-Youn Choi
- Department of Radiology, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Republic of Korea
| | | |
Collapse
|
19
|
Shen Z, Zhang Y, Wu F, Chen H, Ge H. 3D printing combined with anteroposterior cannulated screws for the treatment of posterolateral tibial plateau fracture. BMC Musculoskelet Disord 2023; 24:796. [PMID: 37803292 PMCID: PMC10557243 DOI: 10.1186/s12891-023-06887-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 09/15/2023] [Indexed: 10/08/2023] Open
Abstract
PURPOSE This study aimed to compare the effects of conventional surgery and three-dimension (3D) printing technology-assisted surgery in the treatment of posterolateral tibial plateau fractures (PTPF). METHODS A cohort of 61 patients afflicted with PTPF, spanning from June 2015 to October 2021, was enrolled. They were divided randomly into two groups: 31 cases of 3D printing group, 30 cases of conventional group. The personalized 3D-printed models were used to simulate the surgical procedures in 3D printing group. The demographic characteristics and clinical data were recorded, encompassing operation duration, intraoperative blood loss, intraoperative fluoroscopy shoots and fracture union time. The radiographic outcomes were gauged, encompassing tibiofemoral angle (FTA), tibial plateau angle (TPA), posterolateral slope angle (PSA) and Rasmussen's anatomical score. The functional outcomes were assessed at the 12-month postoperative juncture, encompassing range of motion, Hospital for Special Surgery (HSS) score and Rasmussen's functional score. Furthermore, fracture complications were evaluated,, encompassing infections, traumatic osteoarthritis, and delayed union. RESULTS The 3D printing group exhibited the operation time of 95.8 ± 30.2 min, intraoperative blood loss of 101.1 ± 55.3 ml, and intraoperative fluoroscopy shoots of 6.3 ± 2.3 times, while the conventional group recorded respective values of 115.5 ± 34.0 min, 137.0 ± 49.2 ml and 9.13 ± 2.5 times. Noteworthy disparities were evident between the conventional and 3D printing groups (p < 0.05). Furthermore, in comparison to the conventional group, the 3D printing group exhibited commendable radiological and functional outcomes both immediately and 12 months post-surgery, although statistical significance was not attained. Moreover, the 3D printing group experienced a paucity of complications compared to the conventional group, although without achieving statistical significance. CONCLUSION This study demonstrated the clinical feasibility of 3D printing combined with anteroposterior cannulated screws for the treatment of posterolateral tibial plateau fracture.
Collapse
Affiliation(s)
- Zhihao Shen
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, NO.109, XueYuan West Road, Luheng District, Wenzhou, 325000, Zhejiang Province, P.R. China
| | - Yingying Zhang
- Department of Radiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, NO.109, XueYuan West Road, Luheng District, Wenzhou, 325000, Zhejiang Province, P.R. China
| | - Feng Wu
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, NO.109, XueYuan West Road, Luheng District, Wenzhou, 325000, Zhejiang Province, P.R. China
| | - Hua Chen
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, NO.109, XueYuan West Road, Luheng District, Wenzhou, 325000, Zhejiang Province, P.R. China
| | - Huaizhi Ge
- Department of Radiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, NO.109, XueYuan West Road, Luheng District, Wenzhou, 325000, Zhejiang Province, P.R. China.
| |
Collapse
|
20
|
Xia J, Wu J, Chen H, Mao J, Xu X, Zhang J, Yang J, Wang Z. Assessment of laparoscopic intracorporeal intestinal anastomosis training using simulation-based 3D printed models: exploring surgical performance and learning curves. Int J Surg 2023; 109:2953-2961. [PMID: 37498142 PMCID: PMC10583936 DOI: 10.1097/js9.0000000000000582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 06/25/2023] [Indexed: 07/28/2023]
Abstract
BACKGROUND AND AIMS Intestinal anastomosis is a clinical procedure widely used to reconstruct the digestive tract, but authentic laparoscopic intracorporeal intestinal anastomosis (LIIA) models are lacking. However, three-dimensional (3D) printing can enable authentic and reusable models. In this paper, a novel cost-effective 3D-printing training model of LIIA is designed and the authenticity and validity of the model are tested. METHODS A fused deposition modeling 3D printing and an assembled lab model were built to test LIIA. Fifteen surgeons were required to perform LIIA, and their operation score and time were recorded and analyzed. Five experts were invited to assess the face and content validity of the models. A study was also performed to further evaluate and validate the learning curve of surgeons. RESULTS The difference in modified anastomosis objective structured assessment of technical skills (MAOSATS) scores between the expert, intermediate, and novice groups were significant (64.1±1.8: 48.5±1.7: 29.5±3.1, P <0.001). In addition, the operation time of the procedure was statistically different for all three groups (21.5±1.9: 30.6±2.8:70.7±4.0, P<0.001 ). The five experts rated the face and content validity of the model very highly, with the median being four out of five. Surgeons who underwent repeated training programs showed improved surgical performance. After eight training sessions, the novices' performance was similar to that of the average level of untrained intermediates, while the operation scores of the intermediates were close to that of the average level of experts. CONCLUSIONS In this study, it is found that the LIIA model exhibits excellent face, content, and construct validity. Repeated simulation training of the LIIA training program improved the surgeon's operative performance, so the model is considered one of the most effective methods for LIIA training and assessment of surgical quality in the future and for reducing healthcare costs.
Collapse
Affiliation(s)
- Jianfu Xia
- Department of General Surgery, The Dingli Clinical College of Wenzhou Medical University, Wenzhou Central Hospital, Wenzhou
- Department of Clinical Medicine, Suzhou Medical College of Soochow University, Suzhou
- Department of Hernia Surgery, Zhejiang Provincial People’s Hospital, Affiliated People’s Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Junjie Wu
- School of Public Health, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Hao Chen
- The Second Clinical Medical College, Zhejiang Chinese Medical University
| | - Jinlei Mao
- The Second Clinical Medical College, Zhejiang Chinese Medical University
| | - Xiaodong Xu
- College of Materials Science and Engineering, Zhejiang University of Technology
| | - Jing Zhang
- College of Materials Science and Engineering, Zhejiang University of Technology
| | - Jin Yang
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, People’s Republic of China
| | - Zhifei Wang
- Department of Hernia Surgery, Zhejiang Provincial People’s Hospital, Affiliated People’s Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| |
Collapse
|
21
|
Arsenkov S, Plavevski O, Nikolovski A, Arsenkov L, Shurlani A, Saliu V. Enhancing surgical planning of distal splenopancreatectomy through 3D printed models: a case report. J Surg Case Rep 2023; 2023:rjad528. [PMID: 37727227 PMCID: PMC10506889 DOI: 10.1093/jscr/rjad528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 08/26/2023] [Indexed: 09/21/2023] Open
Abstract
The complex anatomy of the peripancreatic region was a challenge to many surgeons in the past. Up until recently, the only way to prepare and plan a surgery was through the use of traditional 2D images, obtained via computed tomography or magnetic resonance imaging. Recently, the advantages in the field of 3D printing (also called additive manufacturing, or rapid prototyping) allowed the creation of replicas of the patient's anatomy which is to be used for preoperative planning and visual reference. We present the case of a 46-y.o. patient with a distal pancreatic lesion requiring a distal splenopancreatectomy, who benefited from the use of 3D printing technology. No intraoperative or postoperative complications were encountered, while the created model was used to plan and perform the needed resection.
Collapse
Affiliation(s)
- Stefan Arsenkov
- Department of Abdominal Surgery, University Surgery Hospital “St. Naum Ohridski”, 1000 Skopje, North Macedonia
| | | | - Andrej Nikolovski
- Department of Abdominal Surgery, University Surgery Hospital “St. Naum Ohridski”, 1000 Skopje, North Macedonia
| | - Ljuben Arsenkov
- Department of Abdominal Surgery, University Surgery Hospital “St. Naum Ohridski”, 1000 Skopje, North Macedonia
| | - Arben Shurlani
- Department of Abdominal Surgery, University Surgery Hospital “St. Naum Ohridski”, 1000 Skopje, North Macedonia
| | - Valon Saliu
- Department of Abdominal Surgery, University Surgery Hospital “St. Naum Ohridski”, 1000 Skopje, North Macedonia
| |
Collapse
|
22
|
Masada KM, Cristino DM, Dear KA, Hast MW, Mehta S. 3-D Printed Fracture Models Improve Resident Performance and Clinical Outcomes in Operative Fracture Management. JOURNAL OF SURGICAL EDUCATION 2023; 80:1020-1027. [PMID: 37198080 DOI: 10.1016/j.jsurg.2023.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 12/30/2022] [Accepted: 04/09/2023] [Indexed: 05/19/2023]
Abstract
OBJECTIVE To determine if preoperative examination of patient additive manufactured (AM) fracture models can be used to improve resident operative competency and patient outcomes. DESIGN Prospective cohort study. Seventeen matched pairs of fracture fixation surgeries (for a total of 34 surgeries) were performed. Residents first performed a set of baseline surgeries (n = 17) without AM fracture models. The residents then performed a second set of surgeries randomly assigned to include an AM model (n = 11) or to omit it (n = 6). Following each surgery, the attending surgeon evaluated the resident using an Ottawa Surgical Competency Operating Room Evaluation (O-Score). The authors also recorded clinical outcomes including operative time, blood loss, fluoroscopy duration, and patient reported outcome measurement information system (PROMIS) scores of pain and function at 6 months. SETTING Single-center academic level one trauma center. PARTICIPANTS Twelve orthopaedic residents, between postgraduate year (PGY) 2 and 5, participated in this study. RESULTS Residents significantly improved their O-Scores between the first and second surgery when they trained with AM models for the second surgery (p = 0.004, 2.43 ± 0.79 versus 3.73 ± 0.64). Similar improvements were not observed in the control group (p = 0.916, 2.69 ± 0.69 versus 2.77 ± 0.36). AM model training also significantly improved clinical outcomes, including surgery time (p = 0.006), fluoroscopy exposure time (p = 0.002), and patient reported functional outcomes (p = 0.0006). CONCLUSIONS Conclusions: Training with AM fracture models improves the performance of orthopaedic surgery residents during fracture surgery.
Collapse
Affiliation(s)
- Kendall M Masada
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania.
| | - Danielle M Cristino
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Kayley A Dear
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Michael W Hast
- Hospital of the University of Pennsylvania, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Samir Mehta
- McKay Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
23
|
Immohr MB, Teichert HL, Dos Santos Adrego F, Schmidt V, Sugimura Y, Bauer SJ, Barth M, Lichtenberg A, Akhyari P. Three-Dimensional Bioprinting of Ovine Aortic Valve Endothelial and Interstitial Cells for the Development of Multicellular Tissue Engineered Tissue Constructs. Bioengineering (Basel) 2023; 10:787. [PMID: 37508814 PMCID: PMC10376021 DOI: 10.3390/bioengineering10070787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/25/2023] [Accepted: 06/29/2023] [Indexed: 07/30/2023] Open
Abstract
To investigate the pathogenic mechanisms of calcified aortic valve disease (CAVD), it is necessary to develop a new three-dimensional model that contains valvular interstitial cells (VIC) and valvular endothelial cells (VEC). For this purpose, ovine aortic valves were processed to isolate VIC and VEC that were dissolved in an alginate/gelatin hydrogel. A 3D-bioprinter (3D-Bioplotter® Developer Series, EnvisionTec, Gladbeck, Germany) was used to print cell-laden tissue constructs containing VIC and VEC which were cultured for up to 21 days. The 3D-architecture, the composition of the culture medium, and the hydrogels were modified, and cell viability was assessed. The composition of the culture medium directly affected the cell viability of the multicellular tissue constructs. Co-culture of VIC and VEC with a mixture of 70% valvular interstitial cell and 30% valvular endothelial cell medium components reached the cell viability best tested with about 60% more living cells compared to pure valvular interstitial cell medium (p = 0.02). The tissue constructs retained comparable cell viability after 21 days (p = 0.90) with different 3D-architectures, including a "sandwich" and a "tube" design. Good long-term cell viability was confirmed even for thick multilayer multicellular tissue constructs. The 3D-bioprinting of multicellular tissue constructs with VEC and VIC is a successful new technique to design tissue constructs that mimic the structure of the native aortic valve for research applications of aortic valve pathologies.
Collapse
Affiliation(s)
- Moritz Benjamin Immohr
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
- Department of Cardiac Surgery, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Helena Lauren Teichert
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
| | - Fabió Dos Santos Adrego
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
| | - Vera Schmidt
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
| | - Yukiharu Sugimura
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
- Department of Cardiac Surgery, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Sebastian Johannes Bauer
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
- Department of Cardiac Surgery, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Mareike Barth
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
- Department of Cardiac Surgery, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Artur Lichtenberg
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
| | - Payam Akhyari
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, 40225 Duesseldorf, Germany
- Department of Cardiac Surgery, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| |
Collapse
|
24
|
Vaupel S, Mau R, Kara S, Seitz H, Kragl U, Meyer J. 3D printed and stimulus responsive drug delivery systems based on synthetic polyelectrolyte hydrogels manufactured via digital light processing. J Mater Chem B 2023. [PMID: 37325953 DOI: 10.1039/d3tb00285c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Hydrogels are three-dimensional hydrophilic polymeric networks absorbing up to and even more than 90 wt% of water. These superabsorbent polymers retain their shape during the swelling process while enlarging their volume and mass. In addition to their swelling behavior, hydrogels can possess other interesting properties, such as biocompatibility, good rheological behavior, or even antimicrobial activity. This versatility qualifies hydrogels for many medical applications, especially drug delivery systems. As recently shown, polyelectrolyte-based hydrogels offer beneficial properties for long-term and stimulus-responsive applications. However, the fabrication of complex structures and shapes can be difficult to achieve with common polymerization methods. This obstacle can be overcome by the use of additive manufacturing. 3D printing technology is gaining more and more attention as a method of producing materials for biomedical applications and medical devices. Photopolymerizing 3D printing methods offer superior resolution and high control of the photopolymerization process, allowing the fabrication of complex and customizable designs while being less wasteful. In this work, novel synthetic hydrogels, consisting of [2-(acryloyloxy) ethyl]trimethylammonium chloride (AETMA) as an electrolyte monomer and poly(ethylene glycol)-diacrylate (PEGDA) as a crosslinker, 3D printed via Digital Light Processing (DLP) using a layer height of 100 μm, are reported. The hydrogels obtained showed a high swelling degree q∞m,t ∼ 12 (24 h in PBS; pH 7; 37 °C) and adjustable mechanical properties with high stretchability (εmax ∼ 300%). Additionally, we embedded the model drug acetylsalicylic acid (ASA) and investigated its stimulus-responsive drug release behaviour in different release media. The stimulus responsiveness of the hydrogels is mirrored in their release behavior and could be exploited in triggered as well as sequential release studies, demonstrating a clear ion exchange behavior. The received 3D-printed drug depots could also be printed in complex hollow geometry, exemplarily demonstrated via an individualized frontal neo-ostium implant prototype. Consequently, a drug-releasing, flexible, and swellable material was obtained, combining the best of both worlds: the properties of hydrogels and the ability to print complex shapes.
Collapse
Affiliation(s)
- Sonja Vaupel
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany.
- Institute of Chemistry, University of Rostock, Albert-Einstein-Str. 3a, 18059, Rostock, Germany
| | - Robert Mau
- Department Life, Light & Matter, Faculty for Interdisciplinary Research, University of Rostock, Albert-Einstein-Straße 25, 18059 Rostock, Germany
- Microfluidics, University of Rostock, Justus-von-Liebig-Weg 6, 18059 Rostock, Germany
| | - Selin Kara
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany.
| | - Hermann Seitz
- Department Life, Light & Matter, Faculty for Interdisciplinary Research, University of Rostock, Albert-Einstein-Straße 25, 18059 Rostock, Germany
- Microfluidics, University of Rostock, Justus-von-Liebig-Weg 6, 18059 Rostock, Germany
| | - Udo Kragl
- Institute of Chemistry, University of Rostock, Albert-Einstein-Str. 3a, 18059, Rostock, Germany
- Department Life, Light & Matter, Faculty for Interdisciplinary Research, University of Rostock, Albert-Einstein-Straße 25, 18059 Rostock, Germany
| | - Johanna Meyer
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany.
- Institute of Chemistry, University of Rostock, Albert-Einstein-Str. 3a, 18059, Rostock, Germany
- Department Life, Light & Matter, Faculty for Interdisciplinary Research, University of Rostock, Albert-Einstein-Straße 25, 18059 Rostock, Germany
| |
Collapse
|
25
|
Uhl JF, Sufianov A, Ruiz C, Iakimov Y, Mogorron HJ, Encarnacion Ramirez M, Prat G, Lorea B, Baldoncini M, Goncharov E, Ramirez I, Céspedes JRC, Nurmukhametov R, Montemurro N. The Use of 3D Printed Models for Surgical Simulation of Cranioplasty in Craniosynostosis as Training and Education. Brain Sci 2023; 13:894. [PMID: 37371373 DOI: 10.3390/brainsci13060894] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/22/2023] [Accepted: 05/30/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND The advance in imaging techniques is useful for 3D models and printing leading to a real revolution in many surgical specialties, in particular, neurosurgery. METHODS We report on a clinical study on the use of 3D printed models to perform cranioplasty in patients with craniosynostosis. The participants were recruited from various medical institutions and were divided into two groups: Group A (n = 5) received traditional surgical education (including cadaveric specimens) but without using 3D printed models, while Group B (n = 5) received training using 3D printed models. RESULTS Group B surgeons had the opportunity to plan different techniques and to simulate the cranioplasty. Group B surgeons reported that models provided a realistic and controlled environment for practicing surgical techniques, allowed for repetitive practice, and helped in visualizing the anatomy and pathology of craniosynostosis. CONCLUSION 3D printed models can provide a realistic and controlled environment for neurosurgeons to develop their surgical skills in a safe and efficient manner. The ability to practice on 3D printed models before performing the actual surgery on patients may potentially improve the surgeons' confidence and competence in performing complex craniosynostosis surgeries.
Collapse
Affiliation(s)
- Jean Francois Uhl
- Anatomy Department, Paris University and UNESCO Chair of Digital Anatomy, 75100 Paris, France
| | - Albert Sufianov
- Federal Center of Neurosurgery, Sechenov University, 119435 Moscow, Russia
| | - Camillo Ruiz
- Laboratorio de Investigaciones Morfológicas Aplicadas, Universidad Nacional de La Plata, La Plata B1900, Argentina
| | - Yuri Iakimov
- Federal Center of Neurosurgery, Sechenov University, 119435 Moscow, Russia
| | - Huerta Jose Mogorron
- Anatomy Department, Paris University and UNESCO Chair of Digital Anatomy, 75100 Paris, France
| | | | - Guillermo Prat
- Laboratorio de Investigaciones Morfológicas Aplicadas, Universidad Nacional de La Plata, La Plata B1900, Argentina
| | - Barbara Lorea
- Laboratorio de Investigaciones Morfológicas Aplicadas, Universidad Nacional de La Plata, La Plata B1900, Argentina
| | - Matias Baldoncini
- Laboratory of Microsurgical Neuroanatomy, Second Chair of Gross Anatomy, School of Medicine, University of Buenos Aires, Buenos Aires B1406, Argentina
| | - Evgeniy Goncharov
- Traumatology and Orthopedics Center, Central Clinical Hospital of the Russian Academy of Sciences, 103272 Moscow, Russia
| | - Issael Ramirez
- Neurosurgery Department, The Royal Melbourne Hospital, Melbourne 3000, Australia
| | | | - Renat Nurmukhametov
- Neurological Surgery, Peoples Friendship University of Russia, 103274 Moscow, Russia
| | - Nicola Montemurro
- Department of Neurosurgery, Azienda Ospedaliero Universitaria Pisana (AOUP), University of Pisa, 56100 Pisa, Italy
| |
Collapse
|
26
|
Domsta V, Hänsch C, Lenz S, Gao Z, Matin-Mann F, Scheper V, Lenarz T, Seidlitz A. The Influence of Shape Parameters on Unidirectional Drug Release from 3D Printed Implants and Prediction of Release from Implants with Individualized Shapes. Pharmaceutics 2023; 15:1276. [PMID: 37111760 PMCID: PMC10143641 DOI: 10.3390/pharmaceutics15041276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/31/2023] [Accepted: 04/13/2023] [Indexed: 04/29/2023] Open
Abstract
The local treatment of diseases by drug-eluting implants is a promising tool to enable successful therapy under potentially reduced systemic side effects. Especially, the highly flexible manufacturing technique of 3D printing provides the opportunity for the individualization of implant shapes adapted to the patient-specific anatomy. It can be assumed that variations in shape can strongly affect the released amounts of drug per time. This influence was investigated by performing drug release studies with model implants of different dimensions. For this purpose, bilayered model implants in a simplified geometrical shape in form of bilayered hollow cylinders were developed. The drug-loaded abluminal part consisted of a suitable polymer ratio of Eudragit® RS and RL, while the drug-free luminal part composed of polylactic acid served as a diffusion barrier. Implants with different heights and wall thicknesses were produced using an optimized 3D printing process, and drug release was determined in vitro. The area-to-volume ratio was identified as an important parameter influencing the fractional drug release from the implants. Based on the obtained results drug release from 3D printed implants with individual shapes exemplarily adapted to the frontal neo-ostial anatomy of three different patients was predicted and also tested in an independent set of experiments. The similarity of predicted and tested release profiles indicates the predictability of drug release from individualized implants for this particular drug-eluting system and could possibly facilitate the estimation of the performance of customized implants independent of individual in vitro testing of each implant geometry.
Collapse
Affiliation(s)
- Vanessa Domsta
- Institute of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, University of Greifswald, Felix-Hausdorff-Str. 3, 17489 Greifswald, Germany
| | - Christin Hänsch
- Institute of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, University of Greifswald, Felix-Hausdorff-Str. 3, 17489 Greifswald, Germany
| | - Stine Lenz
- Institute of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, University of Greifswald, Felix-Hausdorff-Str. 3, 17489 Greifswald, Germany
| | - Ziwen Gao
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany
- ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China
- NHC Key Laboratory of Hearing Medicine, Fudan University, Shanghai 200031, China
- State Key Laboratory of Medical Neurobiology and MOE Frontiers Center for Brain Science, Institutes of Biomedical Sciences, Fudan University, Shanghai 200032, China
| | - Farnaz Matin-Mann
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany
| | - Verena Scheper
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all” EXC 1077/1, 30625 Hanover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all” EXC 1077/1, 30625 Hanover, Germany
| | - Anne Seidlitz
- Institute of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, University of Greifswald, Felix-Hausdorff-Str. 3, 17489 Greifswald, Germany
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University Düsseldorf, Universitätsstr. 1, 40225 Düsseldorf, Germany
| |
Collapse
|
27
|
Lawrence LM, Salary R(R, Miller V, Valluri A, Denning KL, Case-Perry S, Abdelgaber K, Smith S, Claudio PP, Day JB. Osteoregenerative Potential of 3D-Printed Poly ε-Caprolactone Tissue Scaffolds In Vitro Using Minimally Manipulative Expansion of Primary Human Bone Marrow Stem Cells. Int J Mol Sci 2023; 24:4940. [PMID: 36902373 PMCID: PMC10003608 DOI: 10.3390/ijms24054940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 02/26/2023] [Accepted: 03/01/2023] [Indexed: 03/08/2023] Open
Abstract
The repair of orthopedic and maxillofacial defects in modern medicine currently relies heavily on the use of autograft, allograft, void fillers, or other structural material composites. This study examines the in vitro osteo regenerative potential of polycaprolactone (PCL) tissue scaffolding, fabricated via a three-dimensional (3D) additive manufacturing technology, i.e., a pneumatic micro extrusion (PME) process. The objectives of this study were: (i) To examine the innate osteoinductive and osteoconductive potential of 3D-printed PCL tissue scaffolding and (ii) To perform a direct in vitro comparison of 3D-printed PCL scaffolding with allograft Allowash® cancellous bone cubes with regards to cell-scaffold interactions and biocompatibility with three primary human bone marrow (hBM) stem cell lines. This study specifically examined cell survival, cell integration, intra-scaffold cell proliferation, and differentiation of progenitor cells to investigate the potential of 3D-printed PCL scaffolds as an alternative to allograft bone material for the repair of orthopedic injuries. We found that mechanically robust PCL bone scaffolds can be fabricated via the PME process and the resulting material did not elicit detectable cytotoxicity. When the widely used osteogenic model SAOS-2 was cultured in PCL extract medium, no detectable effect was observed on cell viability or proliferation with multiple test groups showing viability ranges of 92.2% to 100% relative to a control group with a standard deviation of ±10%. In addition, we found that the honeycomb infill pattern of the 3D-printed PCL scaffold allowed for superior mesenchymal stem-cell integration, proliferation, and biomass increase. When healthy and active primary hBM cell lines, having documented in vitro growth rates with doubling times of 23.9, 24.67, and 30.94 h, were cultured directly into 3D-printed PCL scaffolds, impressive biomass increase values were observed. It was found that the PCL scaffolding material allowed for biomass increase values of 17.17%, 17.14%, and 18.18%, compared to values of 4.29% for allograph material cultured under identical parameters. It was also found that the honeycomb scaffold infill pattern was superior to the cubic and rectangular matrix structures, and provided a superior microenvironment for osteogenic and hematopoietic progenitor cell activity and auto-differentiation of primary hBM stem cells. Histological and immunohistochemical studies performed in this work confirmed the regenerative potential of PCL matrices in the orthopedic setting by displaying the integration, self-organization, and auto-differentiation of hBM progenitor cells within the matrix. Differentiation products including mineralization, self-organizing "proto-osteon" structures, and in vitro erythropoiesis were observed in conjunction with the documented expression of expected bone marrow differentiative markers including CD-99 (>70%), CD-71 (>60%), and CD-61 (>5%). All of the studies were conducted without the addition of any exogenous chemical or hormonal stimulation and exclusively utilized the abiotic and inert material polycaprolactone; setting this work apart from the vast majority of contemporary investigations into synthetic bone scaffold fabrication In summary, this study demonstrates the unique clinical potential of 3D-printed PCL scaffolds for stem cell expansion and incorporation into advanced microstructures created via PME manufacturing to generate a physiologically inert temporary bony defect graft with significant autograft features for enhanced end-stage healing.
Collapse
Affiliation(s)
- Logan M. Lawrence
- Department of Pathology, Joan C. Edwards School of Medicine, Cabell Huntington Hospital Laboratory, Marshall University, Huntington, WV 25701, USA
| | - Roozbeh (Ross) Salary
- Department of Mechanical Engineering, Marshall University, Huntington, WV 25703, USA
- Department of Biomedical Engineering, Marshall University, Huntington, WV 25755, USA
| | - Virginia Miller
- Department of Pathology, Joan C. Edwards School of Medicine, Cabell Huntington Hospital Laboratory, Marshall University, Huntington, WV 25701, USA
| | - Anisha Valluri
- Joan C. Edwards School of Medicine, Marshall University, Huntington, WV 25701, USA
| | - Krista L. Denning
- Department of Pathology, Joan C. Edwards School of Medicine, Cabell Huntington Hospital Laboratory, Marshall University, Huntington, WV 25701, USA
| | - Shannon Case-Perry
- Cabell Huntington Hospital Laboratory, Department of Histology, Mountain Health Network, Huntington, WV 25701, USA
| | - Karim Abdelgaber
- Joan C. Edwards School of Medicine, Marshall University, Huntington, WV 25701, USA
| | - Shannon Smith
- Joan C. Edwards School of Medicine, Marshall University, Huntington, WV 25701, USA
| | - Pier Paolo Claudio
- Department of Pharmacology and Toxicology, University of Mississippi Medical Center, Jackson, MS 39216, USA
- Department of Maxillo-Facial Surgery, University of Mississippi Medical Center, Jackson, MS 39216, USA
| | - James B. Day
- Department of Orthopaedic Surgery, Joan C. Edwards School of Medicine, Marshall University, Huntington, WV 25701, USA
| |
Collapse
|
28
|
Lumbosacral plexus 3D printing with dissection validation - a baseline study with regards to lateral spine surgery. INTERDISCIPLINARY NEUROSURGERY 2023. [DOI: 10.1016/j.inat.2022.101666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
29
|
Nguyen P, Stanislaus I, McGahon C, Pattabathula K, Bryant S, Pinto N, Jenkins J, Meinert C. Quality assurance in 3D-printing: A dimensional accuracy study of patient-specific 3D-printed vascular anatomical models. FRONTIERS IN MEDICAL TECHNOLOGY 2023; 5:1097850. [PMID: 36824261 PMCID: PMC9941637 DOI: 10.3389/fmedt.2023.1097850] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 01/03/2023] [Indexed: 02/10/2023] Open
Abstract
3D printing enables the rapid manufacture of patient-specific anatomical models that substantially improve patient consultation and offer unprecedented opportunities for surgical planning and training. However, the multistep preparation process may inadvertently lead to inaccurate anatomical representations which may impact clinical decision making detrimentally. Here, we investigated the dimensional accuracy of patient-specific vascular anatomical models manufactured via digital anatomical segmentation and Fused-Deposition Modelling (FDM), Stereolithography (SLA), Selective Laser Sintering (SLS), and PolyJet 3D printing, respectively. All printing modalities reliably produced hand-held patient-specific models of high quality. Quantitative assessment revealed an overall dimensional error of 0.20 ± 3.23%, 0.53 ± 3.16%, -0.11 ± 2.81% and -0.72 ± 2.72% for FDM, SLA, PolyJet and SLS printed models, respectively, compared to unmodified Computed Tomography Angiograms (CTAs) data. Comparison of digital 3D models to CTA data revealed an average relative dimensional error of -0.83 ± 2.13% resulting from digital anatomical segmentation and processing. Therefore, dimensional error resulting from the print modality alone were 0.76 ± 2.88%, + 0.90 ± 2.26%, + 1.62 ± 2.20% and +0.88 ± 1.97%, for FDM, SLA, PolyJet and SLS printed models, respectively. Impact on absolute measurements of feature size were minimal and assessment of relative error showed a propensity for models to be marginally underestimated. This study revealed a high level of dimensional accuracy of 3D-printed patient-specific vascular anatomical models, suggesting they meet the requirements to be used as medical devices for clinical applications.
Collapse
Affiliation(s)
- Philip Nguyen
- School of Medicine, The University of Queensland, Brisbane, QLD, Australia
| | - Ivan Stanislaus
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Clover McGahon
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia
| | - Krishna Pattabathula
- Vascular Surgery Department, Royal Brisbane and Women's Hospital, Metro North Hospital and Health Services, Brisbane, QLD, Australia,Vascular Biofabrication Program, Herston Biofabrication Institute, Metro North Hospital and Health Services, Brisbane, QLD, Australia
| | - Samuel Bryant
- Vascular Surgery Department, Royal Brisbane and Women's Hospital, Metro North Hospital and Health Services, Brisbane, QLD, Australia,Vascular Biofabrication Program, Herston Biofabrication Institute, Metro North Hospital and Health Services, Brisbane, QLD, Australia
| | - Nigel Pinto
- Vascular Surgery Department, Royal Brisbane and Women's Hospital, Metro North Hospital and Health Services, Brisbane, QLD, Australia,Vascular Biofabrication Program, Herston Biofabrication Institute, Metro North Hospital and Health Services, Brisbane, QLD, Australia
| | - Jason Jenkins
- Vascular Surgery Department, Royal Brisbane and Women's Hospital, Metro North Hospital and Health Services, Brisbane, QLD, Australia,Vascular Biofabrication Program, Herston Biofabrication Institute, Metro North Hospital and Health Services, Brisbane, QLD, Australia
| | - Christoph Meinert
- Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia,Vascular Biofabrication Program, Herston Biofabrication Institute, Metro North Hospital and Health Services, Brisbane, QLD, Australia,Faculty of Engineering, Architecture and Information Technology, University of Queensland, Brisbane, QLD, Australia,Correspondence: Christoph Meinert
| |
Collapse
|
30
|
Miller JL, Chang RH, Ong CS, Miller GT, Garcia JR, Groves ML, Rosner MK, Baschat AA. Patient-matched fetal simulator for fetoscopic myelomeningocele closure. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2023; 61:270-272. [PMID: 36178849 DOI: 10.1002/uog.26081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/31/2022] [Accepted: 09/22/2022] [Indexed: 05/27/2023]
Affiliation(s)
- J L Miller
- The Johns Hopkins Center for Fetal Therapy, Department of Gynecology and Obstetrics, Johns Hopkins University, Baltimore, MD, USA
| | - R H Chang
- The Johns Hopkins Center for Fetal Therapy, Department of Gynecology and Obstetrics, Johns Hopkins University, Baltimore, MD, USA
| | - C S Ong
- The Johns Hopkins Center for Fetal Therapy, Department of Gynecology and Obstetrics, Johns Hopkins University, Baltimore, MD, USA
| | - G T Miller
- The Johns Hopkins Medicine Simulation Center, Department of Emergency Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - J R Garcia
- Department of Art as Applied to Medicine, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - M L Groves
- Division of Pediatric Neurosurgery, Department of Neurosurgery, Johns Hopkins University, Baltimore, MD, USA
| | - M K Rosner
- The Johns Hopkins Center for Fetal Therapy, Department of Gynecology and Obstetrics, Johns Hopkins University, Baltimore, MD, USA
| | - A A Baschat
- The Johns Hopkins Center for Fetal Therapy, Department of Gynecology and Obstetrics, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
31
|
Lan L, Mao RQ, Qiu RY, Kay J, de Sa D. Immersive Virtual Reality for Patient-Specific Preoperative Planning: A Systematic Review. Surg Innov 2023; 30:109-122. [PMID: 36448920 PMCID: PMC9925905 DOI: 10.1177/15533506221143235] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Background. Immersive virtual reality (iVR) facilitates surgical decision-making by enabling surgeons to interact with complex anatomic structures in realistic 3-dimensional environments. With emerging interest in its applications, its effects on patients and providers should be clarified. This systematic review examines the current literature on iVR for patient-specific preoperative planning. Materials and Methods. A literature search was performed on five databases for publications from January 1, 2000 through March 21, 2021. Primary studies on the use of iVR simulators by surgeons at any level of training for patient-specific preoperative planning were eligible. Two reviewers independently screened titles, abstracts, and full texts, extracted data, and assessed quality using the Quality Assessment Tool for Studies with Diverse Designs (QATSDD). Results were qualitatively synthesized, and descriptive statistics were calculated. Results. The systematic search yielded 2,555 studies in total, with 24 full-texts subsequently included for qualitative synthesis, representing 264 medical personnel and 460 patients. Neurosurgery was the most frequently represented discipline (10/24; 42%). Preoperative iVR did not significantly improve patient-specific outcomes of operative time, blood loss, complications, and length of stay, but may decrease fluoroscopy time. In contrast, iVR improved surgeon-specific outcomes of surgical strategy, anatomy visualization, and confidence. Validity, reliability, and feasibility of patient-specific iVR models were assessed. The mean QATSDD score of included studies was 32.9%. Conclusions. Immersive VR improves surgeon experiences of preoperative planning, with minimal evidence for impact on short-term patient outcomes. Future work should focus on high-quality studies investigating long-term patient outcomes, and utility of preoperative iVR for trainees.
Collapse
Affiliation(s)
- Lucy Lan
- Michael G. DeGroote School of
Medicine, McMaster University, Hamilton, ON, Canada,Lucy Lan, Michael G. DeGroote School of
Medicine, McMaster University, 1280 Main Street West, Hamilton, ON L8N 3Z5,
Canada.
| | - Randi Q. Mao
- Michael G. DeGroote School of
Medicine, McMaster University, Hamilton, ON, Canada
| | - Reva Y. Qiu
- Michael G. DeGroote School of
Medicine, McMaster University, Hamilton, ON, Canada
| | - Jeffrey Kay
- Division of Orthopaedic Surgery,
Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Darren de Sa
- Division of Orthopaedic Surgery,
Department of Surgery, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
32
|
Myung N, Jin S, Cho HJ, Kang HW. User-designed device with programmable release profile for localized treatment. J Control Release 2022; 352:685-699. [PMID: 36328077 DOI: 10.1016/j.jconrel.2022.10.054] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 10/21/2022] [Accepted: 10/26/2022] [Indexed: 11/11/2022]
Abstract
Three-dimensional printing enables precise and on-demand manufacture of customizable drug delivery systems to advance healthcare toward the goal of personalized medicine. However, major challenges remain in realizing personalized drug delivery that fits a patient-specific drug dosing schedule using local drug delivery systems. In this study, a user-designed device is developed as implantable therapeutics that can realize personalized drug release kinetics by programming the inner structural design on the microscale. The drug release kinetics required for various treatments, including dose-dense therapy and combination therapy, can be implemented by controlling the dosage and combination of drugs along with the rate, duration, initiation time, and time interval of drug release according to the device layer design. After implantation of the capsular device in mice, the in vitro-in vivo and pharmacokinetic evaluation of the device is performed, and the therapeutic effect of the developed device is achieved through the local release of doxorubicin. The developed user-designed device provides a novel platform for developing next-generation drug delivery systems for personalized and localized therapy.
Collapse
Affiliation(s)
- Noehyun Myung
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50, UNIST-gil, Eonyang-eup, Ulju-gun, 44919 Ulsan, Republic of Korea
| | - Seokha Jin
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50, UNIST-gil, Eonyang-eup, Ulju-gun, 44919 Ulsan, Republic of Korea
| | - Hyung Joon Cho
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50, UNIST-gil, Eonyang-eup, Ulju-gun, 44919 Ulsan, Republic of Korea.
| | - Hyun-Wook Kang
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50, UNIST-gil, Eonyang-eup, Ulju-gun, 44919 Ulsan, Republic of Korea.
| |
Collapse
|
33
|
Muacevic A, Adler JR, Laleva L, Nakov V, Spiriev T. Three-Dimensional Printing in Neurosurgery: A Review of Current Indications and Applications and a Basic Methodology for Creating a Three-Dimensional Printed Model for the Neurosurgical Practice. Cureus 2022; 14:e33153. [PMID: 36733788 PMCID: PMC9887931 DOI: 10.7759/cureus.33153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/30/2022] [Indexed: 01/01/2023] Open
Abstract
Introduction Three-dimensional (3D) printing is an affordable aid that is useful in neurosurgery. It allows for better visualization and tactile appreciation of the individual anatomy and regions of interest and therefore potentially lowers the risk of complications. There are various applications of this technology in the field of neurosurgery. Materials and methods In this paper, we present a basic methodology for the creation of a 3D printed model using only open-source software for medical image editing, model generation, pre-printing preparation, and analysis of the literature concerning the practical use of this methodology. Results The literature review on the current applications of 3D printed models in neurosurgery shows that they are mostly used for preoperative planning, surgical training, and simulation, closely followed by their use in patient-specific implants and instrumentation and medical education. MaterialiseTM Mimics is the most frequently used commercial software for a 3D modeling for preoperative planning and surgical simulation, while the most popular open-source software for the same applications is 3D Slicer. In this paper, we present the algorithm that we employ for 3D printing using HorosTM, Blender, and Cura software packages which are all free and open-source. Conclusion Three-dimensional printing is becoming widely available and of significance to neurosurgical practice. Currently, there are various applications of this technology that are less demanding in terms of technical knowledge and required fluency in medical imaging software. These predispositions open the field for further research on the possible use of 3D printing in neurosurgery.
Collapse
|
34
|
Zhang M, Guo J, Li H, Ye J, Chen J, Liu J, Xiao M. Comparing the effectiveness of 3D printing technology in the treatment of clavicular fracture between surgeons with different experiences. BMC Musculoskelet Disord 2022; 23:1003. [PMID: 36419043 PMCID: PMC9682691 DOI: 10.1186/s12891-022-05972-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 11/09/2022] [Indexed: 11/24/2022] Open
Abstract
PURPOSE This study aims to examine the use of 3D printing technology to treat clavicular fractures by skilled and inexperienced surgeons. METHODS A total of 80 patients with clavicle fractures (from February 2017 to May 2021) were enrolled in this study. Patients were divided randomly into four groups: group A: Patients underwent low-dose CT scans, and 3D models were printed before inexperienced surgeons performed surgeries; group B: Standard-dose CT were taken, and 3D models were printed before experienced surgeons performed surgeries; group C and D: Standard-dose CT scans were taken in both groups, and the operations were performed differently by inexperienced (group C) and experienced (group D) surgeons. This study documented the operation time, blood loss, incision length, and the number of intraoperative fluoroscopies. RESULTS No statistically significant differences were found in age, gender, fracture site, and fracture type (P value: 0.23-0.88). Group A showed shorter incision length and fewer intraoperative fluoroscopy times than groups C and D (P < 0.05). There were no significant differences in blood loss volume, incision length, and intraoperative fluoroscopy times between group A and group B (P value range: 0.11-0.28). The operation time of group A was no longer than those of groups C and D (P value range: 0.11 and 0.24). CONCLUSION The surgical effectiveness of inexperienced surgeons who applied 3D printing technology before clavicular fracture operation was better than those of inexperienced and experienced surgeons who did not use preoperative 3D printing technology.
Collapse
Affiliation(s)
- Meng Zhang
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
| | - Jianglong Guo
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
| | - Hongyi Li
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
| | - Jingzhi Ye
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
| | - Jun Chen
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
| | - Jingfeng Liu
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
| | - Mengqiang Xiao
- Zhuhai Hospital, GuangdongProvincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China.
| |
Collapse
|
35
|
Molinari G, Emiliani N, Cercenelli L, Bortolani B, Gironi C, Fernandez IJ, Presutti L, Marcelli E. Assessment of a novel patient-specific 3D printed multi-material simulator for endoscopic sinus surgery. Front Bioeng Biotechnol 2022; 10:974021. [PMID: 36466346 PMCID: PMC9712453 DOI: 10.3389/fbioe.2022.974021] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 11/01/2022] [Indexed: 12/01/2023] Open
Abstract
Background: Three-dimensional (3D) printing is an emerging tool in the creation of anatomical models for surgical training. Its use in endoscopic sinus surgery (ESS) has been limited because of the difficulty in replicating the anatomical details. Aim: To describe the development of a patient-specific 3D printed multi-material simulator for use in ESS, and to validate it as a training tool among a group of residents and experts in ear-nose-throat (ENT) surgery. Methods: Advanced material jetting 3D printing technology was used to produce both soft tissues and bony structures of the simulator to increase anatomical realism and tactile feedback of the model. A total of 3 ENT residents and 9 ENT specialists were recruited to perform both non-destructive tasks and ESS steps on the model. The anatomical fidelity and the usefulness of the simulator in ESS training were evaluated through specific questionnaires. Results: The tasks were accomplished by 100% of participants and the survey showed overall high scores both for anatomy fidelity and usefulness in training. Dacryocystorhinostomy, medial antrostomy, and turbinectomy were rated as accurately replicable on the simulator by 75% of participants. Positive scores were obtained also for ethmoidectomy and DRAF procedures, while the replication of sphenoidotomy received neutral ratings by half of the participants. Conclusion: This study demonstrates that a 3D printed multi-material model of the sino-nasal anatomy can be generated with a high level of anatomical accuracy and haptic response. This technology has the potential to be useful in surgical training as an alternative or complementary tool to cadaveric dissection.
Collapse
Affiliation(s)
- Giulia Molinari
- Department of Otolaryngology-Head and Neck Surgery, IRCCS Azienda Ospedaliero-Universitaria of Bologna, Bologna, Italy
- Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Nicolas Emiliani
- eDIMES Lab-Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Laura Cercenelli
- eDIMES Lab-Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Barbara Bortolani
- eDIMES Lab-Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Camilla Gironi
- eDIMES Lab-Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Ignacio Javier Fernandez
- Department of Otolaryngology-Head and Neck Surgery, IRCCS Azienda Ospedaliero-Universitaria of Bologna, Bologna, Italy
- Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Livio Presutti
- Department of Otolaryngology-Head and Neck Surgery, IRCCS Azienda Ospedaliero-Universitaria of Bologna, Bologna, Italy
- Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Emanuela Marcelli
- eDIMES Lab-Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| |
Collapse
|
36
|
Immohr MB, Dos Santos Adrego F, Teichert HL, Schmidt V, Sugimura Y, Bauer S, Barth M, Lichtenberg A, Akhyari P. 3D-bioprinting of aortic valve interstitial cells: impact of hydrogel and printing parameters on cell viability. Biomed Mater 2022; 18. [PMID: 36322974 DOI: 10.1088/1748-605x/ac9f91] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 11/02/2022] [Indexed: 11/05/2022]
Abstract
Calcific aortic valve disease (CAVD) is a frequent cardiac pathology in the aging society. Although valvular interstitial cells (VICs) seem to play a crucial role, mechanisms of CAVD are not fully understood. Development of tissue-engineered cellular models by 3D-bioprinting may help to further investigate underlying mechanisms of CAVD. VIC were isolated from ovine aortic valves and cultured in Dulbecco's modified Eagle's Medium (DMEM). VIC of passages six to ten were dissolved in a hydrogel consisting of 2% alginate and 8% gelatin with a concentration of 2 × 106VIC ml-1. Cell-free and VIC-laden hydrogels were printed with an extrusion-based 3D-bioprinter (3D-Bioplotter®Developer Series, EnvisionTec, Gladbeck, Germany), cross-linked and incubated for up to 28 d. Accuracy and durability of scaffolds was examined by microscopy and cell viability was tested by cell counting kit-8 assay and live/dead staining. 3D-bioprinting of scaffolds was most accurate with a printing pressure ofP< 400 hPa, nozzle speed ofv< 20 mm s-1, hydrogel temperature ofTH= 37 °C and platform temperature ofTP= 5 °C in a 90° parallel line as well as in a honeycomb pattern. Dissolving the hydrogel components in DMEM increased VIC viability on day 21 by 2.5-fold compared to regular 0.5% saline-based hydrogels (p< 0.01). Examination at day 7 revealed dividing and proliferating cells. After 21 d the entire printed scaffolds were filled with proliferating cells. Live/dead cell viability/cytotoxicity staining confirmed beneficial effects of DMEM-based cell-laden VIC hydrogel scaffolds even 28 d after printing. By using low pressure printing methods, we were able to successfully culture cell-laden 3D-bioprinted VIC scaffolds for up to 28 d. Using DMEM-based hydrogels can significantly improve the long-term cell viability and overcome printing-related cell damage. Therefore, future applications 3D-bioprinting of VIC might enable the development of novel tissue engineered cellular 3D-models to examine mechanisms involved in initiation and progression of CAVD.
Collapse
Affiliation(s)
- Moritz Benjamin Immohr
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Fabió Dos Santos Adrego
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Helena Lauren Teichert
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Vera Schmidt
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Yukiharu Sugimura
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Sebastian Bauer
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Mareike Barth
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Artur Lichtenberg
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.,CARID-Cardiovascular Research Institute Düsseldorf, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Payam Akhyari
- Department of Cardiac Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
37
|
Shine KM, Schlegel L, Ho M, Boyd K, Pugliese R. From the ground up: understanding the developing infrastructure and resources of 3D printing facilities in hospital-based settings. 3D Print Med 2022; 8:21. [PMID: 35821456 PMCID: PMC9275538 DOI: 10.1186/s41205-022-00147-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 06/09/2022] [Indexed: 12/02/2022] Open
Abstract
Background 3D printing is a popular technology in many industries secondary to its ability to rapidly produce inexpensive, high fidelity models/products, mainly through layer-by-layer fusion of various substrate materials. In healthcare, 3D printing has garnered interest for its applications in surgery, simulation, education, and medical device development, and 3D printing facilities are now being integrated into hospital-based settings. Yet, little is known regarding the leadership, resources, outputs, and role of these new onsite entities. Methods The purpose of this research was to survey features of North American hospital-based 3D printing facilities to understand their design and utility in anticipation of future expansion. Hospital-based 3D printing labs were recruited through online special interest groups to participate via survey response. Anonymous, voluntary data were collected from 21 facilities over 9 weeks and reported/analyzed in aggregate. Results Of the respondents, > 50% were founded in the past 5 years and 80% in the past decade, indicating recent and rapid growth of such facilities. Labs were most commonly found within large, university-affiliated hospitals/health systems with administration frequently, but not exclusively, through radiology departments, which was shown to enhance collaboration. All groups reported collaborating with other medical specialties/departments and image segmentation as part of the workflow, showing widespread interest in high fidelity, personalized medicine applications. Lab leadership was most often multidisciplinary, with physicians present on nearly all leadership teams. Budgets, personnel, and outputs varied among groups, however, all groups reported engagement in multiple 3D printing applications. Conclusion This preliminary study provides a foundation for understanding the unique nature of hospital-based 3D printing labs. While there is much to learn about such in-house facilities, the data obtained reveal important baseline characteristics. Further research is indicated to validate these early findings and create a detailed picture of the developing infrastructure of 3D printing in healthcare settings. Supplementary Information The online version contains supplementary material available at 10.1186/s41205-022-00147-7.
Collapse
Affiliation(s)
- Kristy M Shine
- Health Design Lab, Thomas Jefferson University, Philadelphia, USA. .,Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, USA. .,Department of Emergency Medicine, Thomas Jefferson University, Philadelphia, USA.
| | - Lauren Schlegel
- Health Design Lab, Thomas Jefferson University, Philadelphia, USA.,Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, USA
| | - Michelle Ho
- Health Design Lab, Thomas Jefferson University, Philadelphia, USA.,Department of Medicine, Pennsylvania Hospital, University of Pennsylvania, Philadelphia, USA
| | - Kaitlyn Boyd
- Health Design Lab, Thomas Jefferson University, Philadelphia, USA.,College of Engineering, Drexel University, Philadelphia, USA
| | - Robert Pugliese
- Health Design Lab, Thomas Jefferson University, Philadelphia, USA.,Innovation Pillar, Thomas Jefferson University, Philadelphia, USA
| |
Collapse
|
38
|
Singh SP, Qureshi FM, Baig F. Commentary: Accessing 3D Printed Vascular Phantoms for Procedural Simulation. Front Surg 2022; 9:910447. [PMID: 35784934 PMCID: PMC9247311 DOI: 10.3389/fsurg.2022.910447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 05/16/2022] [Indexed: 11/13/2022] Open
|
39
|
Organizational and Supply Chain Impacts of 3D Printers Implementation in the Medical Sector. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19127057. [PMID: 35742306 PMCID: PMC9222601 DOI: 10.3390/ijerph19127057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 06/03/2022] [Accepted: 06/07/2022] [Indexed: 02/05/2023]
Abstract
3D printing application extends to various sectors, such as aerospace, construction, art, domestic, up to healthcare. It is in this domain that its adoption could offer technological solutions aimed at improving the individual life and guaranteeing organizational effectiveness. The aim of this study is to understand the way in which the adoption of medical 3D printers has introduced economic-business changes at the supply chain, organizational and environmental level within business processes considering the point of view of 3D printer manufacturers. A multiple case study has been developed, through the administration of a semi-structured interview to 7 Italian companies that design, manufacture and sell 3D printers offering additive technological solutions to the medical sector. The results show how companies believe that the organizational impact related to the adoption of this technology is quite significant, highlighting how it leads to the definition of a new organizational culture. Secondly, it emerges that the adoption of 3D printers within the medical sector also leads to a change in procedures and production activities. Finally, it also emerges that the impact at the supply chain level particularly affects the reduction in the number of players in the supply chain and product time to market.
Collapse
|
40
|
Hu P, Sun J, Wei F, Liu X. Patient-Tailored 3D-Printing Models in the Subspecialty Training of Spinal Tumors: A Comparative Study and Questionnaire Survey. World Neurosurg 2022; 161:e488-e494. [PMID: 35189420 DOI: 10.1016/j.wneu.2022.02.042] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 02/11/2022] [Indexed: 10/19/2022]
Abstract
BACKGROUND Training in the subspecialty of spinal tumors is challenging and less researched. The anatomic variations and complex relationship with paraspinal structures tend to be the main obstacle for the trainees in this field. Three-dimensional (3D)-printing technique has the advantage of individual customization and high fidelity, and can produce case-tailored models as auxiliary tools in medical training. METHODS The main parts of the study included case-based lectures with tailored 3D-printing models, evaluating their performances in a controlled examination and anonymous questionnaire survey regarding the trainees' opinion towards the tailored models. The examination was designed as case-based clinical analysis. All trainees were randomly allocated to the study group and control group, and the former group was additively provided a case-tailored model. RESULTS Thirty-six participants were recruited in this study, including 16 residents and 20 fellows. In the section of examination, there was significant difference in the aspects of describing the involvement of paraspinal structures and discriminating the relationship between the tumor and large vessels (P < 0.05), but similar in the aspects of surgical planning and relevant complications (P > 0.05). In the survey, most participants gave favorable responses to 3D-printing models in the aspects of understanding anatomic structures and relationship, inter-trainee communication, surgical planning, and enhancement of interest and confidence (50.0% to 94.4%, respectively). CONCLUSIONS The 3D-printing model is a valuable tool in the training of new residents and fellows in the subspecialty of spinal tumors. It can facilitate the trainees' understanding of tumor anatomy, surgical readiness, and confidence as well.
Collapse
Affiliation(s)
- Panpan Hu
- Department of Orthopaedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| | - Jie Sun
- Pain Medicine Center, Peking University Third Hospital, Beijing, China
| | - Feng Wei
- Department of Orthopaedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China.
| | - Xiaoguang Liu
- Department of Orthopaedics and Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing, China
| |
Collapse
|
41
|
Development of a Multicolor 3D Printer Using a Novel Filament Shifting Mechanism. INVENTIONS 2022. [DOI: 10.3390/inventions7020034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Three-dimensional printing has become an unchallenged method for the manufacturing of complex shape objects. Although multicolor devices in Fuse Filament Feeder category recently have shown promising developments, their number still remains limited. The present study introduces the design of a new prototype of three-dimensional printer using Fused Filament Feeder and capable of printing multicolor objects. A single-color three-dimensional printer is used as a platform and is augmented for multicolor printing by the implementation of a mechatronic device that provides two functions. First, a transmission mechanism based on planetary gears allows feeding the selected filament color toward the printing head. The second function is provided by a combination of a central cam disk and several pushing rods. It allows selecting the filament color to be fed by the transmission system. The mechatronic device has been dimensioned to manage five different filament colors and the printing head has been modified to accommodate a five-to-one diamond nozzle. The filament shifting device is integrated into the single-color three-dimensional printer and a series of validation experiments has been carried out. These tests have demonstrated the new prototype ability to print out multicolor objects and to rival with commercial three-dimensional printers in terms of dimensional accuracy. This shows the ability of the proposed design and method to be used to upgrade a standard single-color 3D printer into a multicolor one. The presented multicolor 3D printer will be available to the 3D printing community for free.
Collapse
|
42
|
Cao Y, Sang S, An Y, Xiang C, Li Y, Zhen Y. Progress of 3D Printing Techniques for Nasal Cartilage Regeneration. Aesthetic Plast Surg 2022; 46:947-964. [PMID: 34312695 DOI: 10.1007/s00266-021-02472-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 07/05/2021] [Indexed: 12/14/2022]
Abstract
Once cartilage is damaged, its self-repair capacity is very limited. The strategy of tissue engineering has brought a new idea for repairing cartilage defect and cartilage regeneration. In particular, nasal cartilage regeneration is a challenge because of the steady increase in nasal reconstruction after oncologic resection, trauma, or rhinoplasty. From this perspective, three-dimensional (3D) printing has emerged as a promising technology to address the complexity of nasal cartilage regeneration, using patient's image data and computer-aided deposition of cells and biomaterials to precisely fabricate complex, personalized tissue-engineered constructs. In this review, we summarized the major progress of three prevalent 3D printing approaches, including inkjet-based printing, extrusion-based printing and laser-assisted printing. Examples are highlighted to illustrate 3D printing for nasal cartilage regeneration, with special focus on the selection of seeded cell, scaffolds and growth factors. The purpose of this paper is to systematically review recent research about the challenges and progress and look forward to the future of 3D printing techniques for nasal cartilage regeneration.Level of Evidence III This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://www.springer.com/00266 .
Collapse
Affiliation(s)
- Yanyan Cao
- MicroNano System Research Center, College of Information and Computer, Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
- College of Information Science and Engineering, Hebei North University, Zhangjiakou, 075000, China
| | - Shengbo Sang
- MicroNano System Research Center, College of Information and Computer, Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China.
| | - Yang An
- Department of Plastic Surgery, Peking University Third Hospital, Beijing, 100191, China.
| | - Chuan Xiang
- Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, 030001, China
| | - Yanping Li
- Department of Otolaryngology, Head and Neck Surgery, The First Affiliated Hospital of Hebei North University, Zhangjiakou, 075061, China
| | - Yonghuan Zhen
- Department of Plastic Surgery, Peking University Third Hospital, Beijing, 100191, China
| |
Collapse
|
43
|
Cornejo J, Cornejo-Aguilar JA, Vargas M, Helguero CG, Milanezi de Andrade R, Torres-Montoya S, Asensio-Salazar J, Rivero Calle A, Martínez Santos J, Damon A, Quiñones-Hinojosa A, Quintero-Consuegra MD, Umaña JP, Gallo-Bernal S, Briceño M, Tripodi P, Sebastian R, Perales-Villarroel P, De la Cruz-Ku G, Mckenzie T, Arruarana VS, Ji J, Zuluaga L, Haehn DA, Paoli A, Villa JC, Martinez R, Gonzalez C, Grossmann RJ, Escalona G, Cinelli I, Russomano T. Anatomical Engineering and 3D Printing for Surgery and Medical Devices: International Review and Future Exponential Innovations. BIOMED RESEARCH INTERNATIONAL 2022; 2022:6797745. [PMID: 35372574 PMCID: PMC8970887 DOI: 10.1155/2022/6797745] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 02/16/2022] [Accepted: 02/24/2022] [Indexed: 12/26/2022]
Abstract
Three-dimensional printing (3DP) has recently gained importance in the medical industry, especially in surgical specialties. It uses different techniques and materials based on patients' needs, which allows bioprofessionals to design and develop unique pieces using medical imaging provided by computed tomography (CT) and magnetic resonance imaging (MRI). Therefore, the Department of Biology and Medicine and the Department of Physics and Engineering, at the Bioastronautics and Space Mechatronics Research Group, have managed and supervised an international cooperation study, in order to present a general review of the innovative surgical applications, focused on anatomical systems, such as the nervous and craniofacial system, cardiovascular system, digestive system, genitourinary system, and musculoskeletal system. Finally, the integration with augmented, mixed, virtual reality is analyzed to show the advantages of personalized treatments, taking into account the improvements for preoperative, intraoperative planning, and medical training. Also, this article explores the creation of devices and tools for space surgery to get better outcomes under changing gravity conditions.
Collapse
Affiliation(s)
- José Cornejo
- Facultad de Ingeniería, Universidad San Ignacio de Loyola, La Molina, Lima 15024, Peru
- Department of Medicine and Biology & Department of Physics and Engineering, Bioastronautics and Space Mechatronics Research Group, Lima 15024, Peru
| | | | | | | | - Rafhael Milanezi de Andrade
- Robotics and Biomechanics Laboratory, Department of Mechanical Engineering, Universidade Federal do Espírito Santo, Brazil
| | | | | | - Alvaro Rivero Calle
- Department of Oral and Maxillofacial Surgery, Hospital 12 de Octubre, Madrid, Spain
| | - Jaime Martínez Santos
- Department of Neurosurgery, Medical University of South Carolina, Charleston, SC, USA
| | - Aaron Damon
- Department of Neurosurgery, Mayo Clinic, FL, USA
| | | | | | - Juan Pablo Umaña
- Cardiovascular Surgery, Instituto de Cardiología-Fundación Cardioinfantil, Universidad del Rosario, Bogotá DC, Colombia
| | | | - Manolo Briceño
- Villamedic Group, Lima, Peru
- Clínica Internacional, Lima, Peru
| | | | - Raul Sebastian
- Department of Surgery, Northwest Hospital, Randallstown, MD, USA
| | | | - Gabriel De la Cruz-Ku
- Universidad Científica del Sur, Lima, Peru
- Department of Surgery, Mayo Clinic, Rochester, MN, USA
| | | | | | - Jiakai Ji
- Obstetrics and Gynecology, Lincoln Medical and Mental Health Center, Bronx, NY, USA
| | - Laura Zuluaga
- Department of Urology, Fundación Santa Fe de Bogotá, Colombia
| | | | - Albit Paoli
- Howard University Hospital, Washington, DC, USA
| | | | | | - Cristians Gonzalez
- Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, Strasbourg, France
- Institut of Image-Guided Surgery (IHU-Strasbourg), Strasbourg, France
| | | | - Gabriel Escalona
- Experimental Surgery and Simulation Center, Department of Digestive Surgery, Catholic University of Chile, Santiago, Chile
| | - Ilaria Cinelli
- Aerospace Human Factors Association, Aerospace Medical Association, VA, USA
| | | |
Collapse
|
44
|
Kim Y, Lee EJ, Kotula AP, Takagi S, Chow L, Alimperti S. Engineering 3D Printed Scaffolds with Tunable Hydroxyapatite. J Funct Biomater 2022; 13:34. [PMID: 35466216 PMCID: PMC9036238 DOI: 10.3390/jfb13020034] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 03/18/2022] [Accepted: 03/21/2022] [Indexed: 02/04/2023] Open
Abstract
Orthopedic and craniofacial surgical procedures require the reconstruction of bone defects caused by trauma, diseases, and tumor resection. Successful bone restoration entails the development and use of bone grafts with structural, functional, and biological features similar to native tissues. Herein, we developed three-dimensional (3D) printed fine-tuned hydroxyapatite (HA) biomimetic bone structures, which can be applied as grafts, by using calcium phosphate cement (CPC) bioink, which is composed of tetracalcium phosphate (TTCP), dicalcium phosphate anhydrous (DCPA), and a liquid [Polyvinyl butyral (PVB) dissolved in ethanol (EtOH)]. The ink was ejected through a high-resolution syringe nozzle (210 µm) at room temperature into three different concentrations (0.01, 0.1, and 0.5) mol/L of the aqueous sodium phosphate dibasic (Na2HPO4) bath that serves as a hardening accelerator for HA formation. Raman spectrometer, X-ray diffraction (XRD), and scanning electron microscopy (SEM) demonstrated the real-time HA formation in (0.01, 0.1, and 0.5) mol/L Na2HPO4 baths. Under those conditions, HA was formed at different amounts, which tuned the scaffolds' mechanical properties, porosity, and osteoclast activity. Overall, this method may pave the way to engineer 3D bone scaffolds with controlled HA composition and pre-defined properties, which will enhance graft-host integration in various anatomic locations.
Collapse
Affiliation(s)
- Yoontae Kim
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (E.-J.L.); (S.T.); (L.C.)
| | - Eun-Jin Lee
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (E.-J.L.); (S.T.); (L.C.)
| | - Anthony P. Kotula
- Materials Science and Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA;
| | - Shozo Takagi
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (E.-J.L.); (S.T.); (L.C.)
| | - Laurence Chow
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (E.-J.L.); (S.T.); (L.C.)
| | - Stella Alimperti
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (E.-J.L.); (S.T.); (L.C.)
| |
Collapse
|
45
|
Agarwal R, Malhotra S, Gupta V, Jain V. The application of Three-dimensional printing on foot fractures and deformities: A mini-review. ANNALS OF 3D PRINTED MEDICINE 2022. [DOI: 10.1016/j.stlm.2022.100046] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
46
|
Bastawrous S, Wu L, Liacouras PC, Levin DB, Ahmed MT, Strzelecki B, Amendola MF, Lee JT, Coburn J, Ripley B. Establishing 3D Printing at the Point of Care: Basic Principles and Tools for Success. Radiographics 2022; 42:451-468. [PMID: 35119967 DOI: 10.1148/rg.210113] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
As the medical applications of three-dimensional (3D) printing increase, so does the number of health care organizations in which adoption or expansion of 3D printing facilities is under consideration. With recent advancements in 3D printing technology, medical practitioners have embraced this powerful tool to help them to deliver high-quality patient care, with a focus on sustainability. The use of 3D printing in the hospital or clinic at the point of care (POC) has profound potential, but its adoption is not without unanticipated challenges and considerations. The authors provide the basic principles and considerations for building the infrastructure to support 3D printing inside the hospital. This process includes building a business case; determining the requirements for facilities, space, and staff; designing a digital workflow; and considering how electronic health records may have a role in the future. The authors also discuss the supported applications and benefits of medical 3D printing and briefly highlight quality and regulatory considerations. The information presented is meant to be a practical guide to assist radiology departments in exploring the possibilities of POC 3D printing and expanding it from a niche application to a fixture of clinical care. An invited commentary by Ballard is available online. ©RSNA, 2022.
Collapse
Affiliation(s)
- Sarah Bastawrous
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Lei Wu
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Peter C Liacouras
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Dmitry B Levin
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Mohamed Tarek Ahmed
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Brian Strzelecki
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Michael F Amendola
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - James T Lee
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - James Coburn
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| | - Beth Ripley
- Department of Radiology (S.B., L.W., B.R.) and Department of Medicine, Division of Cardiology (D.B.L.), University of Washington School of Medicine, Seattle, Wash; Departments of Radiology (S.B., L.W., B.R.) and Research and Development (B.S.), VA Puget Sound Health Care System, Mailbox S-114, Radiology, 1660 S Columbian Way, Seattle, WA 98108-1597; 3D Medical Applications Center, Walter Reed National Military Medical Center, Bethesda, Md (P.C.L.); Department of Radiology, University of Kentucky College of Medicine, Lexington, Ky (M.T.A., J.T.L.); Department of Surgery, Division of Vascular Surgery, Surgical Services (112), Virginia Commonwealth University School of Medicine, Richmond, Va (M.F.A.); and Department of Bioengineering, University of Maryland, College Park, Md (J.C.)
| |
Collapse
|
47
|
Main Applications and Recent Research Progresses of Additive Manufacturing in Dentistry. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5530188. [PMID: 35252451 PMCID: PMC8894006 DOI: 10.1155/2022/5530188] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 12/16/2021] [Accepted: 01/28/2022] [Indexed: 12/13/2022]
Abstract
In recent ten years, with the fast development of digital and engineering manufacturing technology, additive manufacturing has already been more and more widely used in the field of dentistry, from the first personalized surgical guides to the latest personalized restoration crowns and root implants. In particular, the bioprinting of teeth and tissue is of great potential to realize organ regeneration and finally improve the life quality. In this review paper, we firstly presented the workflow of additive manufacturing technology. Then, we summarized the main applications and recent research progresses of additive manufacturing in dentistry. Lastly, we sketched out some challenges and future directions of additive manufacturing technology in dentistry.
Collapse
|
48
|
He Y, Liu Y, Yin B, Wang D, Wang H, Yao P, Zhou J. Application of Finite Element Analysis Combined With Virtual Computer in Preoperative Planning of Distal Femoral Fracture. Front Surg 2022; 9:803541. [PMID: 35273994 PMCID: PMC8902074 DOI: 10.3389/fsurg.2022.803541] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 01/28/2022] [Indexed: 11/26/2022] Open
Abstract
Background Distal femoral fractures are increasing with an aging population. The computer-assisted preoperative planning has great potential, but there are no preoperative plans to determine appropriate fixation methods for distal femoral fractures on an individual basis. The aims of this study are: (1) to describe the technique of finite element analysis combined with computer-assisted preoperative planning to determine a fixation method for distal femoral fractures and (2) to evaluate the intra-operative realization of this technology and the clinical outcomes based on it for distal femoral fractures. Materials and Methods Between January 2017 and January 2020, 31 patients with distal femoral fractures treated by open reduction and internal fixation were included and randomly divided into two groups based on preoperative planning methods: conventional group (n = 15) and computer-assisted group (n = 16). Firstly, how to determine the most appropriate plate and screw length and placement in the preoperative planning of distal femoral fractures was described. The time taken for preoperative planning for different fracture types in the computer-assisted group was then analyzed. Finally, intraoperative and postoperative parameters were compared between the conventional and computer-assisted groups, assessing operative time, intraoperative blood loss, number of intraoperative fluoroscopies, days of hospital stay, Visual Analog Scale for Pain Score (VAS), and Knee Society Score (KSS). Results Mean total planning time for 33-A, 33-B, and 33-C fractures in computer-assisted group were 194.8 ± 6.49, 163.71 ± 9.22, and 237 ± 5.33 min, respectively. Compared with the conventional group, the patients in the computer-assisted group had less blood loss, fewer fluoroscopic images, and shorter operation time (p < 0.05). However, there was no significant difference in the hospitalization days, KSS score and VAS score between the two groups (p > 0.05). Conclusions The results of this study show that finite element combined with computer-assisted preoperative planning can effectively help surgeons to make accurate and clinically relevant preoperative planning for distal femoral fractures, especially in the selection of appropriate plate length and screw positioning.
Collapse
|
49
|
Sculco PK, Wright T, Malahias MA, Gu A, Bostrom M, Haddad F, Jerabek S, Bolognesi M, Fehring T, Gonzalez DellaValle A, Jiranek W, Walter W, Paprosky W, Garbuz D, Sculco T, Abdel M, Boettner F, Benazzo F, Buttaro M, Choi D, Engh CA, Garcia-Cimbrelo E, Garcia-Rey E, Gehrke T, Griffin WL, Hansen E, Hozack WJ, Jones S, Lee GC, Lipman J, Manktelow A, McLaren AC, Nelissen R, O’Hara L, Perka C, Sporer S. The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium. HSS J 2022; 18:8-41. [PMID: 35082557 PMCID: PMC8753540 DOI: 10.1177/15563316211034850] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 07/07/2021] [Accepted: 07/07/2021] [Indexed: 11/21/2022]
Abstract
Despite growing evidence supporting the evaluation, classification, and treatment of acetabular bone loss in revision hip replacement, advancements have not been systematically incorporated into a single document, and therefore, a comprehensive review of the treatment of severe acetabular bone loss is needed. The Stavros Niarchos Foundation Complex Joint Reconstruction Center at Hospital for Special Surgery held an Acetabular Bone Loss Symposium on June 21, 2019, to answer the following questions: What are the trends, emerging technologies, and areas of future research related to the evaluation and management of acetabular bone loss in revision hip replacement? What constitutes the optimal workup and management strategies for acetabular bone loss? The 36 international experts convened were divided into groups, each assigned to discuss 1 of 4 topics: (1) preoperative planning and postoperative assessment; (2) implant selection, management of osteolysis, and management of massive bone loss; (3) the treatment challenges of pelvic discontinuity, periprosthetic joint infection, instability, and poor bone biology; and (4) the principles of reconstruction and classification of acetabular bone loss. Each group came to consensus, when possible, based on an extensive literature review. This document provides an overview of these 4 areas, the consensus each group arrived at, and directions for future research.
Collapse
Affiliation(s)
- Peter K. Sculco
- Hospital for Special Surgery, New York, NY, USA,Peter K. Sculco, MD, Hospital for Special Surgery, 535 E. 70th St., New York, NY 10021, USA.
| | | | | | - Alexander Gu
- George Washington University School of Medicine & Health Sciences, Washington, DC, USA
| | | | - Fares Haddad
- University College London Hospitals NHS Foundation Trust and Institute of Sport, Exercise & Health, London, UK
| | | | | | | | | | | | - William Walter
- Royal North Shore Hospital, St. Leonards, NSW, Australia
| | - Wayne Paprosky
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Donald Garbuz
- Department of Orthopaedics, The University of British Columbia, Vancouver, BC, Canada
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Betancourt LG, Wong SH, Singh HR, Nento D, Agarwal A. Utility of Three-Dimensional Printed Model in Biventricular Repair of Complex Congenital Cardiac Defects: Case Report and Review of Literature. CHILDREN (BASEL, SWITZERLAND) 2022; 9:184. [PMID: 35204905 PMCID: PMC8870194 DOI: 10.3390/children9020184] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/04/2022] [Accepted: 01/21/2022] [Indexed: 01/14/2023]
Abstract
Heterotaxy is a rare syndrome associated with cardiac complexity, anatomic variability and high morbidity and mortality. It is often challenging to visualize and provide an accurate diagnosis of the cardiac anatomy prior to surgery with the use of conventional imaging techniques. We report a unique case demonstrating how the use of three-dimensional (3D) cardiac printed model allowed us to better understand the anatomical complexity and plan a tailored surgical approach for successful biventricular repair in a patient with heterotaxy syndrome.
Collapse
Affiliation(s)
| | | | | | | | - Arpit Agarwal
- Children’s Hospital of San Antonio, San Antonio, TX 78207, USA; (L.G.B.); (S.H.W.); (H.R.S.); (D.N.)
| |
Collapse
|