1
|
Evolution of Frozen Section in Carcinoma Breast: Systematic Review. Int J Breast Cancer 2022; 2022:4958580. [PMID: 35655582 PMCID: PMC9152418 DOI: 10.1155/2022/4958580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Accepted: 03/28/2022] [Indexed: 11/17/2022] Open
Abstract
Background. The frozen section (FS) has been a good technique in surgical management of breast lesions since many years. But complete agreement and cooperation have not been achieved everywhere among surgeons and pathologists especially in the developing countries. FS undergoes continuous criticism due to various shortcomings but continued to be evaluated especially in developing countries. Objectives. This review was conducted to synthesize information on the use of frozen section in carcinoma breast. Data Sources. The MEDLINE database for frozen section since its origin and its implication in recent breast surgery techniques was studied. Study Eligibility Criteria. Sixty-five articles were reviewed with complete analysis on FS in both benign and malignant breast lesions. Study Appraisal and Synthesis Methods. The analysis of frozen section was done as a diagnostic tool in breast lesions, margin status in breast conservative surgery in carcinoma breast, and sentinel lymph node and use of immunohistochemistry for sentinel lymph node FS. Results. It was analysed that the FS gives accurate results in margin status analysis, decreasing rerecurrence. Conclusion. The accuracy of FSA, low recurrence rate, avoidance of reoperation, and good cosmesis are the key points of its use in breast conservative surgery. Its use in sentinel lymph node biopsy (SLNB) is equivocal. However, application of immunohistochemistry on frozen section of SLNB is an evolving trend in today’s era.
Collapse
|
2
|
Lu W, Tu L, Xie D, Yao F, Lin L, Li Y, Li D, Mou C. A systematic review and meta-analysis: value of ultrasound-guided vacuum-assisted biopsy in the diagnosis and treatment of breast lesions. Gland Surg 2021; 10:3020-3029. [PMID: 34804888 DOI: 10.21037/gs-21-611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 10/11/2021] [Indexed: 12/24/2022]
Abstract
Background In recent years, according to global statistics, breast cancer is the main disease affecting women. Ultrasound-guided vacuum-assisted biopsy (VAB) has become a frequently used method for breast cancer detection because of its accuracy, simplicity, and fewer complications. Methods In PubMed, Medline, EMbase and Cochrane central register of controlled trials, the retrieval time was from the establishment of the database to March 2021, and the keywords included breast tumor, breast cancer-related diseases, breast lesions, vacuum-assisted breast biopsy, sensitivity and specificity. Meta-analysis was performed using RevMan5.3 software provided by the Cochrane Collaboration. Results A total of 10 articles were included using a random-effects model that pooled the sensitivity, specificity, and other accuracy measures of VAB. The summary receiver operating characteristic (SROC) characteristic curve was used to summarize the overall accuracy. The sensitivity range was 0.94 to 1.00 (mean, 0.981; 95% CI, 0.972-0.987) with a specificity range of 0.87-1.00 (mean, 0.999; 95% CI, 0.997-0.999). The preoperative platelet-lymphocyte ratio (PLR) was 93.84 (95% CI, 41.55-211.95), the neutrophil to lymphocyte ratio (NLR) was 0.05 (95% CI, 0.03-0.09), the sensitivity and specificity of χ2 were 37.10 (P=0.011) and 32.00 (P=0.043), respectively, while those of PLR, NLR, and duration of response (DOR) were 46.98 (P=0.001), 54.92 (P=0.001), and 43.49 (P=0.002), respectively. Differences were considerable. Discussion In this meta-analysis, a total of 10 articles were included. VAB is an accurate type of biopsy to detect female breast cancer. The results of the meta-analysis were stable, and VAB had high sensitivity (98%) and specificity (nearly 100%).
Collapse
Affiliation(s)
- Weifeng Lu
- Department of Anesthesia Surgery Center, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China.,Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China
| | - Lili Tu
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Geriatric Endocrinology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Danxuan Xie
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Thyroid and Breast Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China
| | - Fu Yao
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Thyroid and Breast Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China
| | - Li Lin
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Thyroid and Breast Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China
| | - Ying Li
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Thyroid and Breast Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China
| | - Dexin Li
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Hepatobiliary Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China
| | - Chengjin Mou
- Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, Chengdu, China.,Department of Thyroid and Breast Surgery, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Eastern Hospital, Chengdu, China
| |
Collapse
|
3
|
Zhang YJ, Wei L, Li J, Zheng YQ, Li XR. Status quo and development trend of breast biopsy technology. Gland Surg 2014; 2:15-24. [PMID: 25083451 DOI: 10.3978/j.issn.2227-684x.2013.02.01] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Accepted: 02/18/2013] [Indexed: 11/14/2022]
Abstract
Triple assessment is a standard method for assessment of breast diseases, which includes clinical evaluation, radiographic assessment and pathological assessment. Biopsy for breast disease is the gold standard for pathological assessment, including incisional biopsy, excisional biopsy, core needle biopsy, vacuum-assisted biopsy and bite biopsy. With the continuous advancement of diagnostic and treatment technology for breast cancer, collection of diseased tissue has also undergone a gradual transition from traditional open surgery to biopsy. This review summarizes the current situation and development of breast biopsy technology to provide an insight into the latest details such as the safety and reliability as the basis for selection of the most appropriate techniques for specific settings.
Collapse
Affiliation(s)
- Yan-Jun Zhang
- 1 Division of Breast Surgery, Department of General Surgery, General Hospital of Chinese People's Liberation Army (301 Hospital), Beijing, China ; 2 Department of radiation oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Lichun Wei
- 1 Division of Breast Surgery, Department of General Surgery, General Hospital of Chinese People's Liberation Army (301 Hospital), Beijing, China ; 2 Department of radiation oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Jie Li
- 1 Division of Breast Surgery, Department of General Surgery, General Hospital of Chinese People's Liberation Army (301 Hospital), Beijing, China ; 2 Department of radiation oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Yi-Qiong Zheng
- 1 Division of Breast Surgery, Department of General Surgery, General Hospital of Chinese People's Liberation Army (301 Hospital), Beijing, China ; 2 Department of radiation oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Xi-Ru Li
- 1 Division of Breast Surgery, Department of General Surgery, General Hospital of Chinese People's Liberation Army (301 Hospital), Beijing, China ; 2 Department of radiation oncology, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| |
Collapse
|
4
|
dos Santos RLC, Lasmar RB, Fontes TMP, Fonseca RDCSDP, Saldanha PDAB, dos Santos RFC. Percutaneous core biopsy of palpable breast lesions: accuracy of frozen section histopathological exam in the diagnosis of breast cancer. Rev Col Bras Cir 2014; 41:7-10. [PMID: 24770767 DOI: 10.1590/s0100-69912014000100003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2012] [Accepted: 01/05/2013] [Indexed: 01/07/2023] Open
Abstract
OBJECTIVE to evaluate the accuracy of frozen section histopathology from fragments of tissue obtained by percutaneous core needle biopsy of palpable tumors in the diagnosis of breast cancer. METHODS a cohort study was performed on 57 patients with palpable tumors and suspected breast cancer undergoing percutaneous thick needle core biopsy. The fragments were analyzed by the same pathologist. RESULTS frozen section diagnosed 16 benign cases (28.6%) and 40 malignant (71.4%), whereas paraffin showed that 15 were benign (26.8%) and 41 malignant (73.2%). Histopathological examinations were concordant in 55 cases and there was one false-negative (6.2%). Statistics rates were: negative predictive value of 93.8%, positive predictive value of 100%, no false-positive (0%), one false negative (6.2%), specificity of 100%, sensitivity of 97 6%; observed agreement = 98.2%; expected agreement = 59.9%, Kappa = 0.955 [ 95% CI = 0.925-0.974, p < 0.01 ]. CONCLUSIONS frozen section histopathological findings showed excellent correlation with the findings by the technique in paraffin in the fragments of palpable breast tumors obtained by thick needle percutaneous core biopsy (98.2% accuracy). Therefore, in these patients, it was possible to anticipate the diagnosis, staging and the breast cancer treatment planning.
Collapse
|
5
|
Rapid on-site cytologic examination of 1500 breast lesions using the modified Shorr’s stain. Breast Cancer 2013; 22:280-6. [DOI: 10.1007/s12282-013-0479-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Accepted: 05/20/2013] [Indexed: 10/26/2022]
|
6
|
Bulte JP, Polman L, Schlooz-Vries M, Werner A, Besselink R, Sessink K, Mus R, Lardenoije S, Imhof-Tas M, Bulten J, van Engen-van Grunsven ACH, Schaafsma E, Strobbe LJA, Bult P, De Wilt JHW. One-day core needle biopsy in a breast clinic: 4 years experience. Breast Cancer Res Treat 2012; 137:609-16. [DOI: 10.1007/s10549-012-2372-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2012] [Accepted: 12/03/2012] [Indexed: 10/27/2022]
|
7
|
Diagnostic value of vacuum-assisted breast biopsy for breast carcinoma: a meta-analysis and systematic review. Breast Cancer Res Treat 2010; 120:469-79. [DOI: 10.1007/s10549-010-0750-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2009] [Accepted: 01/18/2010] [Indexed: 10/19/2022]
|
8
|
Brunner AH, Sagmeister T, Kremer J, Riss P, Brustmann H. The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions. BMC Cancer 2009; 9:341. [PMID: 19778424 PMCID: PMC2759967 DOI: 10.1186/1471-2407-9-341] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2009] [Accepted: 09/24/2009] [Indexed: 11/10/2022] Open
Abstract
Background Limited data are available to evaluate the accuracy of frozen section analysis and ultrasound- guided core needle biopsy of the breast. Methods In a retrospective analysis data of 120 consecutive handheldultrasound- guided 14- gauge automated core needle biopsies (CNB) in 109 consecutive patients with breast lesions between 2006 and 2007 were evaluated. Results In our outpatient clinic120 CNB were performed. In 59/120 (49.2%) cases we compared histological diagnosis on frozen sections with those on paraffin sections of CNB and finally with the result of open biopsy. Of the cases 42/59 (71.2%) were proved to be malignant and 17/59 (28.8%) to be benign in the definitive histology. 2/59 (3.3%) biopsies had a false negative frozen section result. No false positive results of the intraoperative frozen section analysis were obtained, resulting in a sensitivity, specificity and positive predicting value (PPV) and negative predicting value (NPV) of 95%, 100%, 100% and 90%, respectively. Histological and morphobiological parameters did not show up relevance for correct frozen section analysis. In cases of malignancy time between diagnosis and definitive treatment could not be reduced due to frozen section analysis. Conclusion The frozen section analysis of suspect breast lesions performed by CNB displays good sensitivity/specificity characteristics. Immediate investigations of CNB is an accurate diagnostic tool and an important step in reducing psychological strain by minimizing the period of uncertainty in patients with breast tumor.
Collapse
Affiliation(s)
- Andreas H Brunner
- Department of Obstetrics and Gynecology, Division of Gynecology and Gynecologic Oncology, Landesklinikum Moedling/Vienna, Austria.
| | | | | | | | | |
Collapse
|
9
|
Schueller G, Schueller-Weidekamm C, Helbich TH. Accuracy of ultrasound-guided, large-core needle breast biopsy. Eur Radiol 2008; 18:1761-73. [PMID: 18414872 DOI: 10.1007/s00330-008-0955-4] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2007] [Revised: 01/31/2008] [Accepted: 02/23/2008] [Indexed: 11/30/2022]
Abstract
Ultrasound-guided, large-core needle biopsy (US-LCNB) of suspicious breast lesions is acknowledged as less invasive and less expensive and less time consuming than surgical biopsy, and provides a histologic diagnosis with a comparable high degree. US-LCNB has been proven to help reduce the number of unnecessary surgeries for benign disease. Its limitations, however, are false-negative results and underestimation of disease. Thus, the demand for breast teams is to carefully adhere to the principles of triple assessment and imaging-histologic correlation, and follow-up of lesions with a specific benign histology after biopsy. Also, the acceptance of guidelines and rigorous quality controls help to reliably minimize the delay in the diagnosis of breast cancer in patients with false-negative biopsies. This paper aims to summarize the equipment and methods as well as the benefits and limitations of US-LCNB. Also, guidelines of quality assessment are suggested. Finally, recent developments which may help to overcome the limitations of US-LCNB will be discussed, i.e., directional vacuum-assisted biopsy (VAB), three-dimensional (3D) US-guided biopsy, as well as the use of tissue harmonic imaging (THI) and compound imaging (CI) during biopsy.
Collapse
Affiliation(s)
- G Schueller
- Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
| | | | | |
Collapse
|
10
|
Uematsu T, Kasami M. Core wash cytology of breast lesions by ultrasonographically guided core needle biopsy. Breast Cancer Res Treat 2007; 109:251-3. [PMID: 17616804 DOI: 10.1007/s10549-007-9642-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2007] [Accepted: 06/01/2007] [Indexed: 10/23/2022]
Abstract
Previous studies demonstrated that core wash cytology by stereotactic needle biopsy was useful for the immediate diagnosis of breast lesions. The purpose of this study was to assess the accuracy of core wash cytology of breast lesions by ultrasonographically (US) guided core needle biopsy (CNB). US-guided 18-gauge CNB was performed in a series of 458 cases. Each CNB sample was washed in saline solution. Core wash cytology of the washed core material was performed on material obtained by saline solution lavage of the fragments using a cytocentrifuge. The cytological diagnoses were divided into five categories: benign, atypical/indeterminate, suspicious/probably malignant, malignant, and unsatisfactory, which then were compared with the CNB results. The cytological diagnoses of the 458 cases were as follows: 106 lesions (23.1%) were benign, 28 lesions (6.1%) were atypical/indeterminate, 42 lesions (9.2%) were suspicious/probably malignant, 88 lesions (19.2%) were malignant, and 194 lesions (42.4%) were unsatisfactory. The core wash cytology had a sensitivity of 89% (141 of 158), and a specificity of 72% (76 of 106). The CNB showed 143 of 194 unsatisfactory samples (74%) to be benign, three to be high-risk, and 48 (25%) to be malignant. Unsatisfactory samples were obtained from significantly more benign than malignant lesions. In conclusion, the high rate of insufficient samples for core wash cytology of breast lesions by US-guided CNB makes its use impractical in this setting. This technique is not useful for immediate diagnosis of breast lesions by US-guided CNB.
Collapse
Affiliation(s)
- Takayoshi Uematsu
- Division of Breast Imaging, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka 411-8777, Japan.
| | | |
Collapse
|