1
|
Gurluler E, Polatkan V, Senol K, Gokgoz MS. The feasibility and added value of indocyanine green tracing in guiding sentinel lymph node biopsy for breast cancer. Asian J Surg 2024:S1015-9584(24)01460-X. [PMID: 39034234 DOI: 10.1016/j.asjsur.2024.07.090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 07/05/2024] [Indexed: 07/23/2024] Open
Abstract
OBJECTIVE To compare the effectiveness of combined (indocyanine green [ICG]+ blue dye) tracing versus blue dye alone in guiding sentinel lymph node biopsy (SLNB) in breast cancer. METHODS A total of 112 female patients (mean ± SD age: 51.9 ± 11.9 years) with clinically node-negative (cN0) early-stage breast cancer were evaluated based on SLN tracing technique including methylene blue + ICG (n = 17), isosulfan blue + ICG (n = 19) and methylene blue alone (n = 76). Mapping patterns of each SLN, the number of total lymph nodes (TLNs) removed, including metastatic and hyperplastic lymph nodes, and the metastatic lymph node detection rate were analyzed for each tracing technique. RESULTS SLN detection rate was 100 % with complementary use of ICG. No significant difference was noted between methylene blue + ICG, isosulfan + ICG and methylene blue alone groups in terms of the mean ± SD number of TLNs removed (3.9 ± 2.5, 4.7 ± 3 and 3.7 ± 2.3, respectively) and metastatic lymph node detection rates (16.0 %, 16.25 % and 13.98 %, respectively). Complementary use of ICG revealed the N0 stage for 66.6 % of cases considered as Nx (cannot be detected) on blue dye alone. Also, 20.0 % of N0 and 11.1 % of N1 cases on blue dye were diagnosed with more advance nodal status (N1 and N2 respectively) after complementary use of ICG. CONCLUSIONS The combined tracing (ICG + blue dye) seems valuable not only in terms of the SLN detection rates and lymph node yield but also has an added value in providing more accurate nodal stating and thus a proper final tumor staging with considerable therapeutic implications.
Collapse
Affiliation(s)
- Ercument Gurluler
- Department of General Surgery, Bursa Uludag University Faculty of Medicine, Bursa, Turkey.
| | - Volkan Polatkan
- Department of General Surgery, Bursa Uludag University Faculty of Medicine, Bursa, Turkey.
| | - Kazim Senol
- Department of General Surgery, Bursa Uludag University Faculty of Medicine, Bursa, Turkey.
| | | |
Collapse
|
2
|
Zhang QJ, Cao ZC, Zhu Q, Sun Y, Li RD, Tong JL, Zheng Q. Application value of indocyanine green fluorescence imaging in guiding sentinel lymph node biopsy diagnosis of gastric cancer: Meta-analysis. World J Gastrointest Surg 2024; 16:1883-1893. [PMID: 38983339 PMCID: PMC11230008 DOI: 10.4240/wjgs.v16.i6.1883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 05/12/2024] [Accepted: 05/24/2024] [Indexed: 06/27/2024] Open
Abstract
BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide, and its early diagnosis is crucial to improve the survival rate of patients. Indocyanine green fluorescence imaging (ICG-FI), as a new imaging technology, has shown potential application prospects in oncology surgery. The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice. AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocyanine green (ICG)-guided sentinel lymph node (SLN) biopsy for gastric cancer. METHODS Electronic databases such as PubMed, Embase, Medline, Web of Science, and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy. Stata 12.0 software was used for analysis by combining the "bivariable mixed effect model" with the "midas" command. The true positive value, false positive value, false negative value, true negative value, and other information from the included literature were extracted. A literature quality assessment map was drawn to describe the overall quality of the included literature. A forest plot was used for heterogeneity analysis, and P < 0.01 was considered to indicate statistical significance. A funnel plot was used to assess publication bias, and P < 0.1 was considered to indicate statistical significance. The summary receiver operating characteristic (SROC) curve was used to calculate the area under the curve (AUC) to determine the diagnostic accuracy. If there was interstudy heterogeneity (I 2 > 50%), meta-regression analysis and subgroup analysis were performed. RESULTS Optical imaging involves two methods: Near-infrared (NIR) imaging and fluorescence imaging. A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis. The positive likelihood ratio was 30.39 (95%CI: 0.92-1.00), the sensitivity was 0.95 (95%CI: 0.82-0.99), and the specificity was 1.00 (95%CI: 0.92-1.00). The negative likelihood ratio was 0.05 (95%CI: 0.01-0.20), the diagnostic odds ratio was 225.54 (95%CI: 88.81-572.77), and the SROC AUC was 1.00 (95%CI: The crucial values were sensitivity = 0.95 (95%CI: 0.82-0.99) and specificity = 1.00 (95%CI: 0.92-1.00). The Deeks method revealed that the "diagnostic odds ratio" funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical (P = 0.01), suggesting significant publication bias. Further meta-subgroup analysis revealed that, compared with fluorescence imaging, NIR imaging had greater sensitivity (0.98 vs 0.73). Compared with optical imaging immediately after ICG injection, optical imaging after 20 minutes obtained greater sensitivity (0.98 vs 0.70). Compared with that of patients with an average SLN detection number < 4, the sensitivity of patients with a SLN detection number ≥ 4 was greater (0.96 vs 0.68). Compared with hematoxylin-eosin (HE) staining, immunohistochemical (+ HE) staining showed greater sensitivity (0.99 vs 0.84). Compared with subserous injection of ICG, submucosal injection achieved greater sensitivity (0.98 vs 0.40). Compared with 5 g/L ICG, 0.5 and 0.05 g/L ICG had greater sensitivity (0.98 vs 0.83), and cT1 stage had greater sensitivity (0.96 vs 0.72) than cT2 to cT3 clinical stage. Compared with that of patients ≤ 26, the sensitivity of patients > 26 was greater (0.96 vs 0.65). Compared with the literature published before 2010, the sensitivity of the literature published after 2010 was greater (0.97 vs 0.81), and the differences were statistically significant (all P < 0.05). CONCLUSION For the diagnosis of stomach cancer, optical imaging in conjunction with ICG-guided SLN biopsy is a therapeutically viable approach, especially for early gastric cancer. The concentration of ICG used in the SLN biopsy of gastric cancer may be too high. Moreover, NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.
Collapse
Affiliation(s)
- Qi-Jia Zhang
- Department of Oncology, The Second Hospital of Nanjing, Affiliated to Nanjing University of Chinese Medicine, Nanjing 210003, Jiangsu Province, China
| | - Zhi-Cheng Cao
- Department of Oncology, The Second Hospital of Nanjing, Affiliated to Nanjing University of Chinese Medicine, Nanjing 210003, Jiangsu Province, China
| | - Qin Zhu
- Department of Oncology, The Second Hospital of Nanjing, Affiliated to Nanjing University of Chinese Medicine, Nanjing 210003, Jiangsu Province, China
| | - Yu Sun
- Department of Oncology, The Second Hospital of Nanjing, Affiliated to Nanjing University of Chinese Medicine, Nanjing 210003, Jiangsu Province, China
| | - Rong-Da Li
- Department of Gastrointestinal Surgery, Qilu Hospital of Shandong University, Jinan 250063, Shandong Province, China
| | - Jin-Long Tong
- Department of Oncology, The Second Hospital of Nanjing, Affiliated to Nanjing University of Chinese Medicine, Nanjing 210003, Jiangsu Province, China
| | - Qin Zheng
- Department of Oncology, The Second Hospital of Nanjing, Affiliated to Nanjing University of Chinese Medicine, Nanjing 210003, Jiangsu Province, China
| |
Collapse
|
3
|
White KP, Sinagra D, Dip F, Rosenthal RJ, Mueller EA, Lo Menzo E, Rancati A. Indocyanine green fluorescence versus blue dye, technetium-99M, and the dual-marker combination of technetium-99M + blue dye for sentinel lymph node detection in early breast cancer-meta-analysis including consistency analysis. Surgery 2024; 175:963-973. [PMID: 38097484 DOI: 10.1016/j.surg.2023.10.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 10/13/2023] [Accepted: 10/25/2023] [Indexed: 03/17/2024]
Abstract
BACKGROUND Axillary sentinel lymph node biopsies are standard of care in patients with breast cancer and no clinically apparent metastases. Traditionally, technetium-99m, blue dye, or both have been used to identify sentinel lymph nodes. However, blue dyes miss up to 40% of sentinel lymph nodes, while technetium-99m use is complex, costly, and exposes patients to radiation. Over the past decade, studies have consistently found the biologically inert fluorescent indocyanine green to be 95% to 100% sensitive in detecting breast cancer sentinel lymph nodes, yet indocyanine green remains infrequently used. METHODS We conducted an extensive meta-analysis comparing indocyanine green against blue dye, technetium-99m, and the dual-marker combination of technetium-99m + BD. Unlike prior meta-analyses that only assessed either per-case or per-node sentinel lymph node detection, we analyzed the following 5 metrics: per-case and per-node sentinel lymph node detection and metastasis-positive sentinel lymph node sensitivity, and mean number of sentinel lymph nodes/case. We further examined the consistency and magnitude of between-study superiority and statistically significant within-study superiority of each marker against others. RESULTS For every metric and analysis approach, indocyanine green was clearly superior to blue dye and at least non-inferior, if not superior, to technetium-99m and technetium-99m + blue dye. Assessing the consistency of superiority by at least 2.0%, indocyanine green was superior to blue dye 73 times versus 1, to technetium-99m 42 times versus 9, and to technetium-99m + blue dye 6 times versus 0. Within-study statistically significant differences favored indocyanine green over blue dye 29 times versus 0 and over technetium-99m 11 times versus 2. DISCUSSION For sentinel lymph node detection in patients with breast cancer with no clinically apparent metastases, indocyanine green is clearly and consistently superior to blue dye and either non-inferior or superior to technetium-99m and technetium-99m + blue dye.
Collapse
Affiliation(s)
- Kevin P White
- ScienceRight International Health Research, London, Canada
| | - Diego Sinagra
- Hospital de Clínicas Jose de San Martín, Buenos Aires, Argentina
| | - Fernando Dip
- Hospital de Clínicas Jose de San Martín, Buenos Aires, Argentina
| | | | - Edgar A Mueller
- Institute for Clinical Pharmacology, Medical Faculty, Technical University, Dresden, Germany
| | | | - Alberto Rancati
- Hospital de Clínicas Jose de San Martín, Buenos Aires, Argentina.
| |
Collapse
|
4
|
Swerdlow M, Vangsness KL, Kress GT, Georgescu A, Wong AK, Carré AL. Determining Accurate Dye Combinations for Sentinel Lymph Node Detection: A Systematic Review. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2024; 12:e5598. [PMID: 38333031 PMCID: PMC10852373 DOI: 10.1097/gox.0000000000005598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 12/19/2023] [Indexed: 02/10/2024]
Abstract
Background Lymphatic dyes are commonly used to map the drainage path from tumor to lymphatics, which are biopsied to determine if spread has occurred. A blue dye in combination with technetium-99 is considered the gold standard for mapping, although many other dyes and dye combinations are used. Not all of these substances have the same detection efficacy. Methods A systematic review of PubMed, SCOPUS, Web of Science, and Medline was performed. The predefined search terms were (indocyanine green OR isosulfan blue OR lymphazurin OR patent blue OR methylene blue OR fluorescein OR technetium-99) AND combination AND dye AND (sentinel lymph node biopsy OR lymphedema OR lymphatics OR lymph OR microsurgery OR cancer OR tumor OR melanoma OR carcinoma OR sarcoma). Results The initial search returned 4267 articles. From these studies, 37 were selected as candidates that met inclusion criteria. After a full-text review, 34 studies were selected for inclusion. Eighty-nine methods of sentinel lymph node (SLN) detection were trialed using 22 unique dyes, dye combinations, or other tracers. In total, 12,157 SLNs of 12,801 SLNs were identified. Dye accuracy ranged from 100% to 69.8% detection. Five dye combinations had 100% accuracy. Dye combinations were more accurate than single dyes. Conclusions Combining lymphatic dyes improves SLN detection results. Replacing technetium-99 with ICG may allow for increased access to SLN procedures with comparable results. The ideal SLN tracer is a low-cost molecule with a high affinity for lymphatic vessels due to size and chemical composition, visualization without specialized equipment, and no adverse effects.
Collapse
Affiliation(s)
- Mark Swerdlow
- From the Division of Plastic Surgery, City of Hope National Medical Center, Duarte, Calif
- Department of Surgery, Keck School of Medicine of USC, Los Angeles, Calif
| | - Kella L. Vangsness
- From the Division of Plastic Surgery, City of Hope National Medical Center, Duarte, Calif
| | - Gavin T. Kress
- From the Division of Plastic Surgery, City of Hope National Medical Center, Duarte, Calif
- Department of Surgery, Keck School of Medicine of USC, Los Angeles, Calif
| | - Anda Georgescu
- From the Division of Plastic Surgery, City of Hope National Medical Center, Duarte, Calif
| | - Alex K. Wong
- From the Division of Plastic Surgery, City of Hope National Medical Center, Duarte, Calif
| | - Antoine Lyonel Carré
- From the Division of Plastic Surgery, City of Hope National Medical Center, Duarte, Calif
| |
Collapse
|
5
|
Akrida I, Michalopoulos NV, Lagadinou M, Papadoliopoulou M, Maroulis I, Mulita F. An Updated Review on the Emerging Role of Indocyanine Green (ICG) as a Sentinel Lymph Node Tracer in Breast Cancer. Cancers (Basel) 2023; 15:5755. [PMID: 38136301 PMCID: PMC10742210 DOI: 10.3390/cancers15245755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/04/2023] [Accepted: 12/06/2023] [Indexed: 12/24/2023] Open
Abstract
Sentinel lymph node biopsy (SLNB) has become the standard of care for clinically node-negative breast cancer and has recently been shown by clinical trials to be also feasible for clinically node-positive patients treated with primary systemic therapy. The dual technique using both radioisotope (RI) and blue dye (BD) as tracers for the identification of sentinel lymph nodes is considered the gold standard. However, allergic reactions to blue dye as well as logistics issues related to the use of radioactive agents, have led to research on new sentinel lymph node (SLN) tracers and to the development and introduction of novel techniques in the clinical practice. Indocyanine green (ICG) is a water-soluble dye with fluorescent properties in the near-infrared (NIR) spectrum. ICG has been shown to be safe and effective as a tracer during SLNB for breast cancer and accumulating evidence suggests that ICG is superior to BD and at least comparable to RI alone and to RI combined with BD. Thus, ICG was recently proposed as a reliable SLN tracer in some breast cancer clinical practice guidelines. Nevertheless, there is lack of consensus regarding the optimal role of ICG for SLN mapping. Specifically, it is yet to be determined whether ICG should be used in addition to BD and/or RI, or if ICG could potentially replace these long-established traditional SLN tracers. This article is an updated overview of somerecent studies that compared ICG with BD and/or RI regarding their accuracy and effectiveness during SLNB for breast cancer.
Collapse
Affiliation(s)
- Ioanna Akrida
- Department of Surgery, General University Hospital of Patras, 26504 Rio, Greece; (I.A.); (I.M.)
| | - Nikolaos V. Michalopoulos
- 4th Department of Surgery, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 1 Rimini Street, Chaidari, 12462 Athens, Greece; (N.V.M.); (M.P.)
| | - Maria Lagadinou
- Department of Internal Medicine, General University Hospital of Patras, 26504 Rio, Greece;
| | - Maria Papadoliopoulou
- 4th Department of Surgery, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 1 Rimini Street, Chaidari, 12462 Athens, Greece; (N.V.M.); (M.P.)
| | - Ioannis Maroulis
- Department of Surgery, General University Hospital of Patras, 26504 Rio, Greece; (I.A.); (I.M.)
| | - Francesk Mulita
- Department of Surgery, General University Hospital of Patras, 26504 Rio, Greece; (I.A.); (I.M.)
| |
Collapse
|
6
|
da Silva Sá R, Von Ah Rodrigues RF, Bugalho LA, da Silva SU, Pinto Nazário AC. Evaluation of the efficacy of using indocyanine green associated with fluorescence in sentinel lymph node biopsy. PLoS One 2023; 18:e0273886. [PMID: 37878619 PMCID: PMC10599532 DOI: 10.1371/journal.pone.0273886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 07/17/2023] [Indexed: 10/27/2023] Open
Abstract
INTRODUCTION Sentinel lymph node biopsy is the technique recommended for the axillary staging of patients with breast cancer in the initial stages without clinical axillary involvement. Three techniques are widely used globally to detect sentinel lymph nodes: patent blue, the radiopharmaceutical technetium 99 with gamma probe, and the combination of these two. OBJECTIVES To evaluate the sentinel lymph node detection rate with an innovative technique: indocyanine green (ICG) associated with fluorescence in breast cancer patients, and compare it with patent blue and a combination of patent blue and indocyanine green. METHODS 99 patients were sequentially (not randomly) allocated into 3 arms with 33 patients submitted to sentinel lymph node techniques. One arm underwent patent blue dying, the other indocyanine green, and the third received a combination of both. The detection rates between arms were compared. RESULTS The detection rate in identifying the sentinel lymph node was 78.8% with patent blue, 93.9% with indocyanine green, and 100% with the combination. Indocyanine green identified two sentinel nodes in 48.5% of patients; the other groups more commonly had only one node identified. The mean time to sentinel lymph node identification was 20.6 ± 10.7 SD (standard deviation) minutes among patients submitted to the patent blue dye, 8.6 ± 6.6 minutes in the indocyanine green arm, and 10 ± 8.9 minutes in the combined group (P<0.001; Student's test). The mean surgery time was 69.4 ± 16.9; 55.1 ± 13.9; and 69.4 ± 19.3 minutes respectively (P<0.001; Student's test). CONCLUSIONS The sentinel lymph node detection rate by fluorescence using indocyanine green was 93.9%, considered adequate. The rates using patent blue, indocyanine green, and patent blue plus indocyanine green (combined) were significantly different, and the indocyanine green alone is also acceptable, since it has a good performance in sentinel lymph node identification and it can avoid tattooing, with a 100% sentinel lymph node detection rate when combined with patent blue.
Collapse
Affiliation(s)
- Rafael da Silva Sá
- Discipline of Mastology, Department of Gynecology, Universidade Federal de São Paulo (UNIFESP), São Paulo, São Paulo, Brazil
- Department of Gynecology and Mastology, Hospital de Esperança, Presidente Prudente, São Paulo, Brazil
- Universidade do Oeste Paulista (UNOESTE), Presidente Prudente, São Paulo, Brazil
| | | | - Luiz Antônio Bugalho
- Department of Gynecology and Mastology, Hospital de Esperança, Presidente Prudente, São Paulo, Brazil
| | | | - Afonso Celso Pinto Nazário
- Discipline of Mastology, Department of Gynecology, Universidade Federal de São Paulo (UNIFESP), São Paulo, São Paulo, Brazil
| |
Collapse
|
7
|
Wang P, Shuai J, Leng Z, Ji Y. Meta-analysis of the application value of indocyanine green fluorescence imaging in guiding sentinel lymph node biopsy for breast cancer. Photodiagnosis Photodyn Ther 2023; 43:103742. [PMID: 37567333 DOI: 10.1016/j.pdpdt.2023.103742] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/19/2023] [Accepted: 08/08/2023] [Indexed: 08/13/2023]
Abstract
OBJECTIVE The main objective of this study was to compare the application value of indocyanine green fluorescence imaging (ICGFI) and its combined tracing method with the blue dye method in guiding sentinel lymph node biopsy for breast cancer. MATERIALS AND METHODS A computerized search of the Pubmed, Embase, Web of Science, and Cochrane Library databases was conducted to identify all relevant literature on ICGFI compared to the sole methylene blue (MB) tracing method in guiding sentinel lymph node biopsy for breast cancer. The search was performed up until May 2023. After assessing the quality of the included studies, a meta-analysis was conducted using STATA 12.0 software. RESULTS A total of 11 relevant studies were included in this research. The analysis results showed that, in terms of the detection rate, the ICGFI group had a higher detection rate to the MB group [odds ratio (OR) = 8.64, 95% CI: 5.46-13.66, P = 0.000], and had a higher quantity compared to the MB group [weighted mean difference (WMD) = 0.72, 95% CI 0.31-1.13, P = 0.001], and it also had a lower false-negative rate [OR = 0.10, 95% CI 0.02-0.43, P = 0.002]. However, there was no statistically significant difference in the positive detection rate, and sensitivity comparison. CONCLUSION The indocyanine green fluorescence imaging and tracing method for sentinel lymph node biopsy for breast cancer are simple and effective, and they are well suited for clinical use. A multicenter randomized controlled trial with a large sample size should be conducted in the future for further validation of the method.
Collapse
Affiliation(s)
- Peng Wang
- Department of Thyroid and Breast Surgery, People's Hospital of Meishan, Meishan, Sichuan 620000, China.
| | - Jinhao Shuai
- Department of Thyroid and Breast Surgery, People's Hospital of Meishan, Meishan, Sichuan 620000, China
| | - Zhaofang Leng
- Department of Thyroid and Breast Surgery, People's Hospital of Meishan, Meishan, Sichuan 620000, China
| | - Yichi Ji
- Department of Thyroid and Breast Surgery, People's Hospital of Meishan, Meishan, Sichuan 620000, China
| |
Collapse
|
8
|
Šepetys G, Gudavičienė D, Jakutis N. Detection of Sentinel Lymph Nodes During Breast Cancer Surgery: A Literature Overview. LIETUVOS CHIRURGIJA 2023. [DOI: 10.15388/lietchirur.2023.22.73] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
Abstract
Introduction. Detecting metastases is an important part of successful breast cancer treatment. Usually, the tumor tissue first spreads to the sentinel lymph nodes. Removal of the latter during surgery and histological examination allows to assess the patient’s disease stage, prognosis and treatment. The literature provides more than one approach or a combination of them, allowing us to accurately identify the breast’s sentinel lymph nodes and avoid removing all axillary lymph nodes. Purpose. To review the methods of intraoperative detection of breast sentinel lymph nodes presented in the literature. Research material and methods. Publications were searched using the specialized information search system Google Scholar. Keywords used in the search: breast sentinel lymph nodes, intraoperative detection. After evaluating the exclusion criteria, the review was based on 25 scientific publications. Results. 4 individual measures and 2 combinations of them can be used to detect sentinel breast lymph nodes during surgery. The materials used can be injected in 6 different ways. Conclusions. The combination of technetium-99m radiocolloid and methylene blue can be evaluated as the best method for intraoperative detection of sentinel lymph nodes in breast cancer patients. On the other hand, due to radiation and operating costs, more attention is being paid to the use of indocyanine green, superparamagnetic iron oxide, methylene blue dye, and the detection of metastases without surgery. Superficial methods of injecting the substance should be combined with deep ones due to the possibility of detecting extra-axillary sentinel lymph nodes of the breast. Ultimately, all decisions must be made on a case-by-case basis.
Collapse
|
9
|
Yang R, Dong C, Jiang T, Zhang X, Zhang F, Fan Z. Indocyanine Green and Methylene Blue Dye Guided Sentinel Lymph Node Biopsy in Early Breast Cancer: A Single-Center Retrospective Survival Study in 1574 Patients. Clin Breast Cancer 2023; 23:408-414. [PMID: 36907808 DOI: 10.1016/j.clbc.2023.02.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 01/18/2023] [Accepted: 02/06/2023] [Indexed: 02/12/2023]
Abstract
BACKGROUND Currently, the standard tracing method is to use blue dyes and radioisotope as the tracer for sentinel lymph node biopsy (SLNB). However, there are variations in the choice of tracer in different countries and regions. Some new tracers are also gradually applied in clinical practice, but there is still a lack of long-term follow-up data to confirm their clinical application value. PATIENTS AND METHODS Clinicopathological and postoperative treatment follow-up data were collected from patients with early-stage cTis-2N0M0 breast cancer who underwent SLNB using a dual-tracer method of ICG combined with MB. Statistical indicators including the identification rate, the number of sentinel lymph nodes (SLNs), regional lymph node recurrence, disease-free survival (DFS) and overall survival (OS) were analyzed. RESULTS Among the 1574 patients, SLNs were successfully detected during surgery in 1569 patients, with a detection rate of 99.7%; the median number of SLNs removed was 3. A total of 1531 patients were included in the survival analysis, with a median follow-up of 4.7 (0.5-7.9) years. In total, patients with positive SLNs had a 5-year DFS and OS of 90.6% and 94.7%, respectively. The 5-year DFS and OS of patients with negative SLNs were 95.6% and 97.3%, respectively. The postoperative regional lymph node recurrence rate was 0.7% in patients with negative SLNs. CONCLUSION Indocyanine green combined with methylene blue dual-tracer method is safe and effective in sentinel lymph node biopsy in patients with early breast cancer.
Collapse
Affiliation(s)
- Ruming Yang
- Department of Breast Surgery, General Surgery Center, The First Hospital of Jilin University, Changchun, Jilin Province, 130021 China.
| | - Chengji Dong
- Department of Hapatopancreatobiliary Surgery, General Surgery Center, The First Hospital of Jilin University, Changchun, Jilin Province, 130021, China.
| | - Tinghan Jiang
- Department of Breast Surgery, General Surgery Center, The First Hospital of Jilin University, Changchun, Jilin Province, 130021 China.
| | - Xiaoxiao Zhang
- Department of Breast Surgery, General Surgery Center, The First Hospital of Jilin University, Changchun, Jilin Province, 130021 China.
| | - Fan Zhang
- Department of Breast Surgery, General Surgery Center, The First Hospital of Jilin University, Changchun, Jilin Province, 130021 China.
| | - Zhimin Fan
- Department of Breast Surgery, General Surgery Center, The First Hospital of Jilin University, Changchun, Jilin Province, 130021 China.
| |
Collapse
|
10
|
Clinical evaluation of the first domestically produced generic isosulfan blue injection in sentinel lymph node biopsy for early breast cancer in China: a multicenter, single-arm, open validation trial (CSBrS-024). Chin Med J (Engl) 2022; 135:1753-1755. [PMID: 35970595 PMCID: PMC9509065 DOI: 10.1097/cm9.0000000000002309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
|
11
|
Xu Y, Wu H, Zhang W, Shen Y, Jiang Y, Meng L. Comparing single or dual tracing modality on sentinel lymph node biopsy from patients who plan to omitting axillary lymph node dissection referring to the criteria of Z0011 trial: a retrospective study. Updates Surg 2022; 74:1073-1078. [PMID: 35389176 DOI: 10.1007/s13304-022-01285-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 03/25/2022] [Indexed: 11/29/2022]
Abstract
Axillary lymph node dissection (ALND) can be omitted in the part of the breast-conserving patients with positive sentinel lymph nodes (SLNs) since Z0011 trial has presented. Nevertheless, to date, no studies revealed the influence of different tracing modalities (single tracer versus dual tracers) for sentinel lymph node biopsy (SLNB) on axillary management referring to Z0011 trial criteria. This study aimed to assess whether different tracing modalities of SLNB have impact on axillary management referring to Z0011 trial criteria. The clinical data of breast-conserving patients who underwent SLNB guided by combination of methylene blue (MB) and indocyanine green(ICG) were retrospectively analyzed in our center. The numbers of metastatic (positive) SLNs guided by the single tracer and the dual tracer were compared by self-control study. 127 patients with 1-2 metastatic SLNs dyed by MB [(recorded as MB(+))]were retrieved from our database between 2016 and 2020. In these cases, 53 patients contained 86 SLNs, which were ICG staining but MB negative staining (recorded as ICG(+)/MB(-)). In addition, 16 patients contained 20 metastatic SLNs with ICG(+)/MB(-). There were six patients finally excluded patients (6/127, 4.7%) who initially met the criteria of Z0011 trial, because the further detection of ICG(+)/MB(-) SLNs led the total numbers of positive SLNs over two. The difference was statistically significant. Single tracing modality may underestimate the positive SLN numbers compared to dual tracing modality. Different tracing modalities of SLNB will significantly affect Axillary management referring to Z0011 trial criteria.
Collapse
Affiliation(s)
- Yingchun Xu
- Department of Breast and Thyroid Surgery, Shaoxing People's Hospital (The First Affiliated Hospital of Shaoxing University), No.568 Zhongxing North Road, Yuecheng District, Shaoxing, 312000, Zhejiang, People's Republic of China
| | - Hanjin Wu
- Department of Breast and Thyroid Surgery, Shaoxing People's Hospital (The First Affiliated Hospital of Shaoxing University), No.568 Zhongxing North Road, Yuecheng District, Shaoxing, 312000, Zhejiang, People's Republic of China
| | - Wei Zhang
- Department of Breast and Thyroid Surgery, Shaoxing People's Hospital (The First Affiliated Hospital of Shaoxing University), No.568 Zhongxing North Road, Yuecheng District, Shaoxing, 312000, Zhejiang, People's Republic of China
| | - Yupeng Shen
- Department of Breast and Thyroid Surgery, Shaoxing People's Hospital (The First Affiliated Hospital of Shaoxing University), No.568 Zhongxing North Road, Yuecheng District, Shaoxing, 312000, Zhejiang, People's Republic of China
| | - Yujie Jiang
- Department of Breast and Thyroid Surgery, Shaoxing People's Hospital (The First Affiliated Hospital of Shaoxing University), No.568 Zhongxing North Road, Yuecheng District, Shaoxing, 312000, Zhejiang, People's Republic of China
| | - Liwei Meng
- Department of Breast and Thyroid Surgery, Shaoxing People's Hospital (The First Affiliated Hospital of Shaoxing University), No.568 Zhongxing North Road, Yuecheng District, Shaoxing, 312000, Zhejiang, People's Republic of China.
| |
Collapse
|
12
|
Yiming A, Wubulikasimu M, Yusuying N. Analysis on factors behind sentinel lymph node metastasis in breast cancer by color ultrasonography, molybdenum target, and pathological detection. World J Surg Oncol 2022; 20:72. [PMID: 35255911 PMCID: PMC8902784 DOI: 10.1186/s12957-022-02531-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 02/18/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND This study aimed to identify the factors underlying the metastasis of breast cancer and sentinel lymph nodes and to screen and analyze the risk factors of sentinel lymph node metastasis to provide a reference and basis for clinical work. METHODS A total of 99 patients with breast cancer were enrolled in this study. These patients received treatment in our hospital between May 2017 and May 2020. The general information, characteristics of the color Doppler echocardiography, molybdenum, conventional pathology, and molecular pathology of the patients were collected. Factors influencing sentinel lymph node metastasis in breast cancer patients were retrospectively analyzed. RESULTS In this study, age, tumor diameter, BI-RADS category, pathology type, expression profiles of CK5/6, EGFR, and CK19, and TP53 and BRAC1/2 mutations were independent risk factors for sentinel lymph node metastasis in breast cancer (P < 0.05). The number and locations of tumors, quadrant of tumors, regularity of tumor margins, presence of blood flow signals, presence of posterior echo attenuation, presence of calcification, histological grade, molecular typing, and mutations of BRAF, ATM, and PALB2 were irrelevant factors (P > 0.05). CONCLUSIONS In conclusion, age, tumor diameter, BI-RADS category, invasive type, expression of CK5/6, EGFR, and CK19, and mutations in TP53 and BRAC1/2 were positively correlated with sentinel lymph node metastasis. These independent risk factors should be given more attention in clinical studies to strengthen the management and control of sentinel lymph node metastasis in high-risk breast cancer and support early chemotherapy or targeted therapy.
Collapse
Affiliation(s)
- Aibibai Yiming
- Department of General Surgery, The Second People's Hospital of Kashgar, Room 3 Building 3, No. 1 Sagelamu Road, Kashgar, Xinjiang, 844000, China
| | - Muhetaer Wubulikasimu
- Department of General Surgery, The Second People's Hospital of Kashgar, Room 3 Building 3, No. 1 Sagelamu Road, Kashgar, Xinjiang, 844000, China
| | - Nuermaimaiti Yusuying
- Department of General Surgery, The Second People's Hospital of Kashgar, Room 3 Building 3, No. 1 Sagelamu Road, Kashgar, Xinjiang, 844000, China.
| |
Collapse
|
13
|
Intraoperative near-infrared fluorescence imaging can identify pelvic nerves in patients with cervical cancer in real time during radical hysterectomy. Eur J Nucl Med Mol Imaging 2022; 49:2929-2937. [PMID: 35230489 PMCID: PMC9206623 DOI: 10.1007/s00259-022-05686-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 01/09/2022] [Indexed: 11/18/2022]
Abstract
Purpose Radical hysterectomy combined with pelvic lymphadenectomy is the standard treatment for early-stage cervical cancer, but unrecognized pelvic nerves are vulnerable to irreversible damage during surgery. This early clinical trial investigated the feasibility and safety of intraoperative near-infrared (NIR) fluorescence imaging (NIR-FI) with indocyanine green (ICG) for identifying pelvic nerves during radical hysterectomy for cervical cancer. Methods Sixty-six adults with cervical cancer were enrolled in this prospective, open-label, single-arm, single-center clinical trial. NIR-FI was performed in vivo to identify genitofemoral (GN), obturator (ON), and hypogastric (HN) nerves intraoperatively. The primary endpoint was the presence of fluorescence in pelvic nerves. Secondary endpoints were the ICG distribution in a nerve specimen and potential underlying causes of fluorescence emission in pelvic nerves. Results In total, 63 patients were analyzed. The ON was visualized bilaterally in 100% (63/63) of patients, with a mean fluorescence signal-to-background ratio (SBR) of 5.3±2.1. The GN was identified bilaterally in 93.7% (59/63) of patients and unilaterally in the remaining 4 patients, with a mean SBR of 4.1±1.9. The HN was identified bilaterally in 81.0% (51/63) of patients and unilaterally in 7.9% (5/63) of patients, with a mean SBR of 3.5±1.3. ICG fluorescence was detected in frozen sections of a nerve specimen, and was mainly distributed in axons. No ICG-related complications were observed. Conclusion This early clinical trial demonstrated the feasibility and safety of NIR-FI to visualize pelvic nerves intraoperatively. Thus, NIR-FI may help surgeons adjust surgical decision-making, avoid nerve damage, and improve surgical outcomes. Trial registration ClinicalTrials.gov NCT04224467
Collapse
|
14
|
Jin Y, Yuan L, Zhang Y, Tang P, Yang Y, Fan L, Chen L, Qi X, Jiang J. A Prospective Self-Controlled Study of Indocyanine Green, Radioisotope, and Methylene Blue for Combined Imaging of Axillary Sentinel Lymph Nodes in Breast Cancer. Front Oncol 2022; 12:803804. [PMID: 35223482 PMCID: PMC8863935 DOI: 10.3389/fonc.2022.803804] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 01/10/2022] [Indexed: 12/25/2022] Open
Abstract
Purpose This self-controlled study aimed to clarify whether indocyanine green (ICG) could be an alternative tracer in the absence of radioisotope (RI) for combined imaging of axillary sentinel lymph node (SLN) in breast cancer. Methods Primary breast cancer, clinically axillary node-negative patients (n = 182) were prospectively enrolled from March 2015 to November 2020. ICG, methylene blue (MB), and RI were used to perform axillary sentinel lymph node biopsy (SLNB). The main observation index was the positivity of ICG + MB vs. RI + MB in axillary SLNB; the secondary observation indicators were the axillary SLN detection rate, mean number of axillary SLNs detected, mean number of metastatic axillary SLNs detected, and safety. Results All 182 patients had axillary SLNs; a total of 925 axillary SLNs were detected. Pathological examination confirmed metastatic axillary SLN in 42 patients (total of 79 metastatic SLNs). Positivity, detection rate of SLNs, detection rate of metastatic SLNs, and the number of metastatic SLNs detected were comparable with RI+MB and ICG+MB (p > 0.05). The mean number of axillary SLNs detected was significantly higher with ICG+MB than with RI+MB (4.99 ± 2.42 vs. 4.02 ± 2.33, p < 0.001). No tracer-related adverse events occurred. Conclusions ICG appears to be a safe and effective axillary SLN tracer, and a feasible alternative to RI in combined imaging for axillary SLN of breast cancer.
Collapse
Affiliation(s)
- Yuting Jin
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Long Yuan
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Yi Zhang
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Peng Tang
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Ying Yang
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Linjun Fan
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Li Chen
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Xiaowei Qi
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Jun Jiang
- Department of Breast Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| |
Collapse
|
15
|
Efficacy of Near-Infrared Fluorescence-Guided Hepatectomy for the Detection of Colorectal Liver Metastases: A Randomized Controlled Trial. J Am Coll Surg 2022; 234:130-137. [PMID: 35213433 DOI: 10.1097/xcs.0000000000000029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND The application of indocyanine green fluorescence-guided hepatectomy for liver metastases from colorectal cancer is in the preliminary stage of clinical practice; thus, its efficacy needs to be determined. This study compared the number of intrahepatic colorectal liver metastases detected intraoperatively and postoperative recovery data between patients who underwent traditional hepatectomy (nonindocyanine green group) and traditional hepatectomy plus intraoperative indocyanine green fluorescence imaging (indocyanine green group). STUDY DESIGN Between January 2018 and March 2020, patients with potentially resectable colorectal liver metastases were randomly assigned to the nonindocyanine green or indocyanine green group. The number of intrahepatic colorectal liver metastases identified intraoperatively and based on postoperative recovery data were compared between both groups. RESULTS Overall, we recruited 80 patients, among whom 72 eligible patients were randomly assigned. After allocation, 64 patients, comprising 32 in each group, underwent the allocated intervention and follow-up. Compared with the nonindocyanine green group, the mean number of intrahepatic colorectal liver metastases identified intraoperatively in the indocyanine green group was significantly greater (mean [standard deviation], 3.03 [1.58] vs 2.28 [1.35]; p = 0.045), the postoperative hospital stay was shorter (p = 0.012) and the 1-year recurrence rate was also lower (p = 0.017). Postoperative complications and 90-day mortality were comparable, with no statistical differences. CONCLUSIONS Indocyanine green fluorescence imaging significantly increases the number of intrahepatic colorectal liver metastases identified and reduces postoperative hospital stay and 1-year recurrence rate without increasing hepatectomy-related complications and mortality rates.
Collapse
|
16
|
Jiang K, Luo B, Hou Z, Li C, Cai H, Tang J, Yao G. Application of an indocyanine green surgical fluorescence imaging system in sentinel lymph node biopsy of acral malignant melanoma. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1456. [PMID: 34734008 PMCID: PMC8506787 DOI: 10.21037/atm-21-4366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 09/18/2021] [Indexed: 11/06/2022]
Abstract
Background Regional lymph node status is an independent influencing factor for the prognosis of acral malignant melanoma, and the accuracy of sentinel lymph node biopsy (SLNB) is directly related to the judgment of regional lymph node status. This study aimed to explore the application value of indocyanine green (ICG) surgical fluorescence imaging system in the SLNB of acral malignant melanoma. Methods A total of 34 patients with acral malignant melanoma were admitted to the Department of Burn and Plastic Surgery in Jiangsu Provincial People’s Hospital from January 2020 to March 2020. Among these patients, 22 required SLNB. ICG and methylene blue (MB) were combined to intraoperatively trace the sentinel lymph nodes (SLNs). The total number of SLNs detected during the operation was counted. We compared the number, detection rate, as well as the detection rate and false negative rate of positive SLNs of SLNs detected by ICG, MB, and ICG combined with MB. Results A total of 56 SLNs were detected in the 22 patients, among which 55 were detected by ICG (98%), 41 were detected by MB (71%), and 56 (100%) were detected by ICG combined with MB, and the average number of SLNs were 2.5, 1.64, and 2.55, respectively. A total of nine SLNs were detected, of which nine were detected by ICG (100%), seven by MB (78%), and nine by ICG combined with MB (100%). Patients with negative SLNs had no recurrence at the 6-month follow-up. Conclusions Compared with MB, the ICG fluorescent imaging system can improve the detection rate of SLNs in patients with acral malignant melanoma. Also, ICG combined with MB was superior to ICG alone.
Collapse
Affiliation(s)
- Keyu Jiang
- Department of Plastic and Burn Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Binlin Luo
- Department of Plastic and Burn Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Zuoqiong Hou
- Department of Plastic and Burn Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Chujun Li
- Department of Plastic and Burn Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Huiming Cai
- Nanjing Nuoyuan Medical Devices Co., Ltd., Nanjing, China
| | - Jian Tang
- Department of Plastic and Burn Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Gang Yao
- Department of Plastic and Burn Surgery, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| |
Collapse
|
17
|
Hidar S, Alimi A, Khlifi A, Chachia S, Kaabia O, Bouguizane S, Bibi M, Khairi H. Indocyanine Green Fluorescence-Guided Sentinel Node Biopsy in Breast Cancer Within a North African Population: A Retrospective Study. Eur J Breast Health 2021; 17:352-355. [PMID: 34651114 DOI: 10.4274/ejbh.galenos.2021.2021-4-11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 06/20/2021] [Indexed: 12/01/2022]
Abstract
Objective Radio isotopes and blue dyes alone or in combination are the most commonly used tracer agents in sentinel node (SN) biopsy for early breast cancer. Recent studies have found fluorescence method using indocyanine green (ICG) as a promising technology with fewer disadvantages. Materials and Methods Retrospective analysis of our database that included patients with clinically node-negative breast cancer scheduled for breast surgery and SN biopsy between 2016 and January 2021. Patients who underwent detection using fluorescence-ICG were included in this study. Results A total of 47 patients were included. Median age was 50 (range: 24-78) years. Mean tumor size was 3.4 ± 1.5 cm. All patients received ICG injection and 11 received a combination of ICG and blue dye. Forty-five successful SN identifications with ICG were performed and 99 nodes retrieved. Eleven procedures were undertaken after initial systemic therapy. Twenty-four patients had at least one positive SN for malignancy. Mean follow up was 29.2 months and no axillary recurrence was noted during the study period. Conclusion ICG appears to be a feasible and accurate method for SN biopsy with high identification rate. This is the first study of ICG in sentinel node biopsy in a North African population.
Collapse
Affiliation(s)
- Samir Hidar
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Amal Alimi
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Abdejlil Khlifi
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Selma Chachia
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Ons Kaabia
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Sassi Bouguizane
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Mohamed Bibi
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| | - Hédi Khairi
- Department of Obstetrics and Gynaecology, F. Hached University Teaching Hospital, Sousse, Tunisia
| |
Collapse
|