1
|
Liu ZY, Ma ZP, Gao K, Ding W, Zhao YX. Coronary Computed Tomography Angiography Using an Optimal Acquisition Time Window Based on Heart Rate Determined During Breath-Holding Following Free Breathing. J Comput Assist Tomogr 2024:00004728-990000000-00358. [PMID: 39303149 DOI: 10.1097/rct.0000000000001666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
OBJECTIVES To compare the image quality and radiation dose in coronary computed tomography angiography (CCTA) based on different acquisition time windows corresponding to the heart rate of breath-holding after free breathing. METHODS Two hundred patients who underwent CCTA with a basal heart rate between 70 and 85 beats/min were divided into groups A and B, with 100 patients in each group. Patients in groups A and B were scanned with the acquisition time window corresponding to the heart rate determined during a breath hold obtained after free breathing and the basal heart rate during free breathing, respectively. Computed tomography (CT) attenuation values of the coronary artery, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. The subjective image scores of the groups were assessed blindly by 2 experienced physicians using a 4-point system, and score consistency was compared using the κ test. The volume CT dose index and dose-length product were recorded for each patient, and the effective dose (ED) was calculated. The Kruskal-Wallis H test was performed to evaluate differences in age, heart rate, and body mass index. A χ2 test was used to evaluate sex differences. An independent-sample t test was employed to compare objective and subjective data such as dose-length product, volume CT dose index, ED, SNR, CNR, and averaged subjective assessment scores. Statistical significance was set at P < 0.05. RESULTS No statistically significant differences occurred in sex, age, or body mass index between patients in group A and group B (all P > 0.05). No significant differences occurred in the mean CT values, mean SNR values, mean CNR values, or mean subjective scores of CCTA images between the patients in groups A and B (P > 0.05). The ED values of the patients in group A were 52.93% lower than those in group B (P < 0.001). CONCLUSION The radiation dose in CCTA examinations can be significantly reduced while maintaining image quality by narrowing the acquisition time window for breath-holding after free breathing.
Collapse
Affiliation(s)
- Zi-Yan Liu
- From the Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, Hebei Province, People's Republic of China
| | | | | | | | | |
Collapse
|
2
|
Miller RJH, Eisenberg E, Friedman J, Cheng V, Hayes S, Tamarappoo B, Thomson L, Berman DS. Impact of heart rate on coronary computed tomographic angiography interpretability with a third-generation dual-source scanner. Int J Cardiol 2019; 295:42-47. [PMID: 31427117 DOI: 10.1016/j.ijcard.2019.07.098] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Revised: 07/20/2019] [Accepted: 07/31/2019] [Indexed: 01/20/2023]
Abstract
BACKGROUND Guidelines suggest coronary computed tomography angiography (CCTA) should be performed with a heart rate (HR) below 60. Third-generation dual-source CT (DSCT) scanners, with improved temporal resolution, and end-systolic acquisition may facilitate imaging at higher HRs. We determined the influence of HR and end-systolic acquisition on image interpretability and quality with a third-generation DSCT. METHODS Patients who underwent CCTA between July 2017 and December 2018 were retrospectively identified. All images were acquired using a SOMATOM Force scanner (Siemens Healthcare). The primary outcome was the presence of any uninterpretable coronary segment. The association between HR and CCTA with uninterpretable segments was assessed with multivariable logistic regression, correcting for demographics and imaging variables. RESULTS In total, 2620 patients were included, mean age 61.4 ± 12.9 years and 61.2% male, with uninterpretable segments present in 229 (8.7%) scans. In multivariable analysis, HR 80-89 was associated with an increased likelihood of having a scan with uninterpretable segments (adjusted odds ratio [OR] 4.53, p < 0.001). However, no significant association was present with end-systolic acquisition (HR 80-89, adjusted OR 2.32, p = 0.125). HR ≥ 90 was associated with a decreased likelihood of good or excellent image quality (adjusted OR 0.26, 95% CI 0.11-0.63, p = 0.003). CONCLUSIONS With third-generation dual-source CT scanners, patients with HR 60-80 can be imaged without impacting image interpretability. End-systolic image acquisition facilitates imaging at HRs > 80 without increasing non-diagnostic scans. Routine use of systolic gating could omit the need for strict HR control and pre-test beta blockade currently required for CCTA.
Collapse
Affiliation(s)
- Robert J H Miller
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Evann Eisenberg
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - John Friedman
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Victor Cheng
- Department of Cardiac Imaging, Oklahoma Heart Institute, Tulsa, OK, United States
| | - Sean Hayes
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Balaji Tamarappoo
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Louise Thomson
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Daniel S Berman
- Department of Imaging, Medicine, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
| |
Collapse
|
3
|
Diagnostic performance of free-breathing coronary computed tomography angiography without heart rate control using 16-cm z-coverage CT with motion-correction algorithm. J Cardiovasc Comput Tomogr 2019; 13:113-117. [DOI: 10.1016/j.jcct.2019.01.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 10/14/2018] [Accepted: 01/03/2019] [Indexed: 11/17/2022]
|
4
|
Scholtz JE, Hedgire S, Ghoshhajra BB. Technical Aspects, Interpretation, and Body of Evidence for Coronary Computed Tomography Angiography. Radiol Clin North Am 2019; 57:13-23. [DOI: 10.1016/j.rcl.2018.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
5
|
Wang XP, Zhu XM, Zhu YS, Liu WY, Yang XH, Huang WW, Xu Y, Tang LJ. Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals? Exp Ther Med 2018; 16:253-259. [PMID: 29896246 PMCID: PMC5995055 DOI: 10.3892/etm.2018.6158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 04/06/2018] [Indexed: 11/06/2022] Open
Abstract
The present study included a total of 111 consecutive patients who had undergone coronary computed tomography (CT) angiography, using a first-generation dual-source CT with automatic tube potential selection and tube current modulation. Body weight (BW) and body mass index (BMI) were recorded prior to CT examinations. Image noise and attenuation of the proximal ascending aorta (AA) and descending aorta (DA) at the middle level of the left ventricle were measured. Correlations between BW, BMI and objective image quality were evaluated using linear regression. In addition, two subgroups based on BMI (BMI ≤25 and >25 kg/m2) were analyzed. Subjective image quality, image noise, the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were all compared between those. The image noise of the AA increased with the BW and BMI (BW: r=0.453, P<0.001; BMI: r=0.545, P<0.001). The CNR and SNR of the AA were inversely correlated with BW and BMI, respectively. The image noise of the DA and the CNR and SNR of the DA exhibited a similar association to those with the BW or BMI. The BMI >25 kg/m2 group had a significant increase in image noise (33.1±6.9 vs. 27.8±4.0 HU, P<0.05) and a significant reduction in CNR and SNR, when compared with those in the BMI ≤25 kg/m2 group (CNR: 18.9±4.3 vs. 16.1±3.7, P<0.05; SNR: 16.0±3.8 vs. 13.6±3.2, P<0.05). Patients with a BMI of ≤25 kg/m2 had more coronary artery segments scored as excellent, compared with patients with a BMI of >25 kg/m2 (P=0.02). In conclusion, this method is not able to achieve a consistent objective image quality across the entire patient population. The impact of BW and BMI on objective image quality was not completely eliminated. BMI-based adjustment of the tube potential may achieve a more consistent image quality compared to automatic tube potential selection, particularly in patients with a larger body habitus.
Collapse
Affiliation(s)
- Xiao-Ping Wang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Xiao-Mei Zhu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Yin-Su Zhu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Wang-Yan Liu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Xiao-Han Yang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Wei-Wei Huang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Yi Xu
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Li-Jun Tang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| |
Collapse
|
6
|
Matveeva A, Schmitt RR, Edtinger K, Wagner M, Kerber S, Deneke T, Uder M, Barth S. Coronary CT angiography in patients with atrial fibrillation: Standard-dose and low-dose imaging with a high-resolution whole-heart CT scanner. Eur Radiol 2018; 28:3432-3440. [PMID: 29426987 DOI: 10.1007/s00330-017-5282-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 12/19/2017] [Accepted: 12/22/2017] [Indexed: 12/18/2022]
Abstract
OBJECTIVE To compare image quality, observer confidence, radiation exposure in the standard-dose (SD-CCTA) and low-dose (LD-CCTA) protocols of coronary CT angiography (CCTA) in patients with atrial fibrillation (AF). MATERIAL AND METHODS CCTA was performed in 303 patients using a CT scanner with 16-cm coverage (111 scans during sinus rhythm (SR); 192 during AF). LD-CCTA was used in 218 patients; SD-CCTA in 85 patients suspected of having coronary artery disease (CAD). Image quality and observer confidence were evaluated on 5-point scales. Radiation doses were recorded. RESULTS Image quality was superior in the SD-CCTA compared to the LD-CCTA (SR 1.45±0.40; AF 1.72±0.46; vs. SR 1.83±0.48; AF 1.92±0.50; p < 0.001). Observers were more confident with SD-CCTA than with LD-CCTA (SR 1.38±0.33; AF 1.61±0.43; vs. SR 1.70±0.45; AF 1.82±0.50; p < 0.001). Radiation doses in AF were significantly higher than in the SR (LD-CCTA, 1.68±0.71 mSv; SD-CCTA, 3.72±1.95 mSv; vs. LD-CCTA, 1.3 ±0.52 mSv; SD-CCTA, 2.67±1.47 mSv; p < 0.001). CONCLUSION Using a low-dose protocol in AF, radiation exposure can be decreased by 50 % at the expense of 20 % impaired image quality. A low-dose CCTA protocol can be considered in young patients, whereas the standard-dose protocol is recommended for older patients and those suspected of having CAD. KEY POINTS • Whole-heart CT allows visualization of the coronary arteries in atrial fibrillation. • Low-dose CT decreases radiation exposure by 50%, image quality by 20%. • Standard-dose CT seems advantageous when concomitant coronary artery disease is suspected.
Collapse
Affiliation(s)
- Anna Matveeva
- Department of Radiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany.
| | - Rainer R Schmitt
- Department of Radiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany
| | - Karoline Edtinger
- Department of Radiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany
| | - Matthias Wagner
- Department of Radiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany
| | - Sebastian Kerber
- Department of Cardiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany
| | - Thomas Deneke
- Department of Cardiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany
| | - Michael Uder
- Department of Radiology, University Hospital Erlangen, Friedrich Alexander Universität (FAU) Erlangen-Nürnberg, Maximiliansplatz 1, 91054, Erlangen, Germany
| | - Sebastian Barth
- Department of Cardiology, Cardiovascular Centre GmbH, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany
| |
Collapse
|
7
|
Image Quality of Prospectively ECG-Triggered Coronary CT Angiography in Heart Transplant Recipients. AJR Am J Roentgenol 2017; 210:314-319. [PMID: 29091000 DOI: 10.2214/ajr.17.18546] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
OBJECTIVE Cardiac allograft vasculopathy (CAV) is among the top causes of death 1 year after heart transplantation (HTx). Coronary CT angiography (CTA) is a potential alternative to invasive imaging in the diagnosis of CAV. However, the higher heart rate (HR) of HTx recipients prompts the use of retrospective ECG-gating, which is associated with higher radiation dose, a major concern in this patient population. Therefore, we sought to evaluate the feasibility and image quality of low-radiation-dose prospectively ECG-triggered coronary CTA in HTx recipients. MATERIALS AND METHODS In total, 1270 coronary segments were evaluated in 50 HTx recipients and 50 matched control subjects who did not undergo HTx. The control subjects were selected from our clinical database and were matched for age, sex, body mass index, HR, and coronary dominance. Scans were performed using 256-MDCT with prospective ECG-triggering. The degree of motion artifacts was evaluated on a per-segment basis on a 4-point Likert-type scale. RESULTS The median HR was 74.0 beats/min (interquartile range [IQR], 67.8-79.3 beats/min) in the HTx group and 73.0 beats/min (IQR, 68.5-80.0 beats/min) in the matched control group (p = 0.58). In the HTx group, more segments had diagnostic image quality compared with the control group (624/662 [94.3%] vs 504/608 [82.9%]; p < 0.001). The mean effective radiation dose was low in both groups (3.7 mSv [IQR, 2.4-4.3 mSv] in the HTx group vs 4.3 mSv [IQR, 2.6-4.3 mSv] in the control group; p = 0.24). CONCLUSION Prospectively ECG-triggered coronary CTA examinations of HTx recipients yielded diagnostic image quality with low radiation dose. Coronary CTA is a promising noninvasive alternative to routine catheterization during follow-up of HTx recipients to diagnose CAV.
Collapse
|
8
|
Scholtz JE, Ghoshhajra B. Advances in cardiac CT contrast injection and acquisition protocols. Cardiovasc Diagn Ther 2017; 7:439-451. [PMID: 29255688 PMCID: PMC5716940 DOI: 10.21037/cdt.2017.06.07] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 05/25/2017] [Indexed: 01/27/2023]
Abstract
Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors.
Collapse
Affiliation(s)
- Jan-Erik Scholtz
- Cardiac MR PET CT Program, Department of Radiology (Cardiovascular Imaging) and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Brian Ghoshhajra
- Cardiac MR PET CT Program, Department of Radiology (Cardiovascular Imaging) and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
9
|
Hedgire S, Ghoshhajra B, Kalra M. Dose optimization in cardiac CT. Phys Med 2017; 41:97-103. [DOI: 10.1016/j.ejmp.2017.04.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Revised: 03/22/2017] [Accepted: 04/19/2017] [Indexed: 10/19/2022] Open
|
10
|
Hedgire SS, Baliyan V, Ghoshhajra BB, Kalra MK. Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments. J Med Imaging (Bellingham) 2017; 4:031211. [PMID: 28894760 DOI: 10.1117/1.jmi.4.3.031211] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 07/28/2017] [Indexed: 12/24/2022] Open
Abstract
Cardiac imagers worldwide are bracing for increased utilization of cardiac computed tomography (CT) in clinical practice. This expanding opportunity brings along a responsibility to produce diagnostic quality images with optimized radiation dose. The following review aims to address the dose reduction strategies in cardiac CT in light of recent scientific evidence and technical developments.
Collapse
Affiliation(s)
- Sandeep S Hedgire
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| | - Vinit Baliyan
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| | - Brian B Ghoshhajra
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| | - Mannudeep K Kalra
- Massachusetts General Hospital, Department of Imaging, Division of Cardiovascular Imaging, Boston, Massachusetts, United States
| |
Collapse
|
11
|
Epicardial adipose tissue is associated with high-risk plaque feature progression in non-culprit lesions. Int J Cardiovasc Imaging 2017; 33:2029-2037. [PMID: 28550587 DOI: 10.1007/s10554-017-1158-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Accepted: 12/26/2016] [Indexed: 10/19/2022]
Abstract
Several studies have suggested a link between epicardial adipose tissue (EAT) volume and high-risk plaques (HRPs); however, little is known about the association between EAT volume and HRP progression in non-culprit lesions (NCLs). Therefore, we evaluated whether EAT can independently predict HRP characteristic progression in NCLs by coronary computed tomography angiography (CCTA). In this single-centre trial, we analysed 131 consecutive patients (median age 61 years, male 72.52%) undergoing CCTA with percutaneous coronary intervention (PCI) for culprit lesions. All patients were scheduled to undergo follow-up CCTA 12 months after PCI. HRP features, including positive remodelling, low attenuation plaque, spotty calcification, and napkin-ring sign, along with EAT volume, were assessed by CCTA. The numbers of HRP features were compared between baseline and follow-up CCTA to detect HRP progression in NCLs, and patients were classified into two groups based on HRP progression. Logistic regression analysis was used to evaluate whether EAT volume was independently associated with HRP progression in NCLs. Overall, 23 of 131 patients who underwent two CCTAs exhibited HRP progression in NCLs (17.6%). Logistic regression analysis showed that a higher baseline EAT volume was associated with NCL HRP progression (odds ratio 1.019, 95% confidence interval 1.009-1.029, P < 0.001). The cut-off value for baseline EAT volume for NCL HRP progression was 107 ml based on receiver-operator characteristic curve analyses, and the area under the curve was 0.66. Baseline EAT volume was identified as an independent predictor of NCL HRP progression.
Collapse
|
12
|
Tan Y, Zhou J, Zhou Y, Yang X, Yang J, Chen Y. Characteristics Detected on Computed Tomography Angiography Predict Coronary Artery Plaque Progression in Non-Culprit Lesions. Korean J Radiol 2017; 18:487-497. [PMID: 28458601 PMCID: PMC5390618 DOI: 10.3348/kjr.2017.18.3.487] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2016] [Accepted: 10/03/2016] [Indexed: 11/15/2022] Open
Abstract
Objective This study sought to determine whether variables detected on coronary computed tomography angiography (CCTA) would predict plaque progression in non-culprit lesions (NCL). Materials and Methods In this single-center trial, we analyzed 103 consecutive patients who were undergoing CCTA and percutaneous coronary intervention (PCI) for culprit lesions. Follow-up CCTA was scheduled 12 months after the PCI, and all patients were followed for 3 years after their second CCTA examination. High-risk plaque features and epicardial adipose tissue (EAT) volume were assessed by CCTA. Each NCL stenosis grade was compared visually between two CCTA scans to detect plaque progression, and patients were stratified into two groups based on this. Logistic regression analysis was used to evaluate the factors that were independently associated with plaque progression in NCLs. Time-to-event curves were compared using the log-rank statistic. Results Overall, 34 of 103 patients exhibited NCL plaque progression (33%). Logistic regression analyses showed that the NCL progression was associated with a history of ST-elevated myocardial infarction (odds ratio [OR] = 5.855, 95% confidence interval [CI] = 1.391–24.635, p = 0.016), follow-up low-density lipoprotein cholesterol level (OR = 6.832, 95% CI = 2.103–22.200, p = 0.001), baseline low-attenuation plaque (OR = 7.311, 95% CI = 1.242–43.028, p = 0.028) and EAT (OR = 1.015, 95% CI = 1.000–1.029, p = 0.044). Following the second CCTA examination, major adverse cardiac events (MACEs) were observed in 12 patients, and NCL plaque progression was significantly associated with future MACEs (log rank p = 0.006). Conclusion Noninvasive assessment of NCLs by CCTA has potential prognostic value.
Collapse
Affiliation(s)
- Yahang Tan
- Department of Cardiology, Chinese PLA General Hospital, Beijing 100853, China.,The School of Medicine, Nankai University, Tianjin 300071, China
| | - Jia Zhou
- Department of Cardiology, Chinese PLA General Hospital, Beijing 100853, China.,Department of Cardiology, Tianjin Chest Hospital, Tianjin 300000, China
| | - Ying Zhou
- Department of Cardiology, Chinese PLA General Hospital, Beijing 100853, China.,Department of Cardiology, Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China
| | - Xiaobo Yang
- Department of Cardiology, Chinese PLA General Hospital, Beijing 100853, China.,The School of Medicine, Nankai University, Tianjin 300071, China
| | - Junjie Yang
- Department of Cardiology, Chinese PLA General Hospital, Beijing 100853, China
| | - Yundai Chen
- Department of Cardiology, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
13
|
|
14
|
Volumetric Single-Beat Coronary Computed Tomography Angiography: Relationship of Image Quality, Heart Rate, and Body Mass Index. Initial Patient Experience With a New Computed Tomography Scanner. J Comput Assist Tomogr 2017; 40:763-72. [PMID: 27331931 DOI: 10.1097/rct.0000000000000428] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). METHODS We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and greater than 70 bpm and also analyzed them in 2 BMI groupings: BMI less than or equal to 30 kg/m and BMI greater than 30 kg/m. RESULTS Mean SNR was 8.7 (SD, 3.1) (n = 349) for group with HR 70 bpm or less and 7.7 (SD, 2.4) (n = 78) for group with HR greater than 70 bpm (P = 0.008). Mean CNR was 6.9 (SD, 2.7) (n = 349) for group with HR 70 bpm or less and 5.9 (SD, 2.2) (n = 78) for group with HR 70 bpm or greater (P = 0.002). Mean SNR was 8.8 (SD, 3.2) (n = 249) for group with BMI 30 kg/m or less and 8.1 (SD, 2.6) (n = 176) for group with BMI greater than 30 kg/m (P = 0.008). Mean CNR was 7.0 (SD, 2.8) (n = 249) for group with BMI 30 kg/m or less and 6.4 (SD, 2.4) (n = 176) for group with BMI greater than 30 kg/m (P = 0.002). The results for mean Likert scale values were statistically different, reflecting difference in IQ between people with HR 70 bpm or less and greater than 70 bpm, BMI 30 kg/m or less, and BMI greater than 30 kg/m.
Collapse
|
15
|
Vadvala HV, Sayegh K, Moy M, Staziaki PV, Ghoshhajra BB. Salvage of diagnostic quality of image acquired by low-radiation-dose prospectively ECG-triggered coronary CTA during ventricular trigeminy: A case report of a novel image processing method. HeartRhythm Case Rep 2016; 2:20-23. [PMID: 28491624 PMCID: PMC5412625 DOI: 10.1016/j.hrcr.2015.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
| | | | | | | | - Brian B. Ghoshhajra
- Address reprint requests and correspondence: Brian B. Ghoshhajra, Assistant Professor of Radiology, Harvard Medical School, Service Chief, Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| |
Collapse
|
16
|
Mantuano A, Barroso RC, Nogueira LP, Colaço MV, Mota CL, Pickler A, Braz D, Salata C, Ferreira-Machado S, de Almeida CE, Gianoncelli A. Alterations in Low-Z Elements Distribution in Heart Tissue after Treatments to Breast Cancer Using LEXRF Technique. ACTA ACUST UNITED AC 2016. [DOI: 10.4236/ajac.2016.711068] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
17
|
ACR Appropriateness Criteria Acute Nonspecific Chest Pain—Low Probability of Coronary Artery Disease. J Am Coll Radiol 2015; 12:1266-71. [DOI: 10.1016/j.jacr.2015.09.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Accepted: 09/03/2015] [Indexed: 11/24/2022]
|
18
|
Celeng C, Vadvala H, Puchner S, Pursnani A, Sharma U, Kovacs A, Maurovich-Horvat P, Hoffmann U, Ghoshhajra B. Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography. Int J Cardiovasc Imaging 2015; 32:91-100. [PMID: 26335369 DOI: 10.1007/s10554-015-0755-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2015] [Accepted: 08/26/2015] [Indexed: 10/23/2022]
Abstract
To define the optimal systolic phase for dual-source computed tomography angiography using an absolute reconstruction delay time after the R-R interval based on the coronary artery motion, we analyzed images reconstructed between 200 and 420 miliseconds (ms) after the R wave at 20 ms increments in 21 patients. Based on the American Heart Association coronary segmentation guidelines, the origin of six coronary artery landmarks (RCA, AM1, PDA, LM, OM1, and D2) were selected to calculate the coronary artery motion velocity. The velocity of the given landmark was defined as the quotient of the route and the length of the time interval. The x, y and z-coordinates of the selected landmark were recorded, and were used for the calculation of the 3D route of coronary artery motion by using a specific equation. Differences in velocities were assessed by analysis of variance for repeated measures; Bonferroni post hoc tests were used for multiple pair wise comparisons. 1488 landmarks were measured (6 locations at 12 systolic time points) in 21 patients and were analyzed. The mean values of the minimum velocities were calculated separately for each heart rate group (i.e. <65; 65-80; and >80 bpm). The mean lowest coronary artery velocities in each segment occurred in the middle period of each time interval of the acquired systolic phase i.e. 280-340 ms. No differences were found in the minimal coronary artery velocities between the three HR groups, with the exception of the AM1 branch (p = 0.00495) between <65 and >80 bpm (p = 0.03), and at HRs of 65-80 versus >80 bpm (p = 0.006). During an absolute delay of 200-420 ms after the R-wave, the ideal reconstruction interval varies significantly among coronary artery segments. Decreased velocities occur between 280 to 340 ms. Therefore a narrow range of systolic intervals, rather than a single phase, should be acquired.
Collapse
Affiliation(s)
- Csilla Celeng
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA. .,MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68 Varosmajor Street, 1122, Budapest, Hungary.
| | - Harshna Vadvala
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.
| | - Stefan Puchner
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.
| | - Amit Pursnani
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.
| | - Umesh Sharma
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.
| | - Attila Kovacs
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68 Varosmajor Street, 1122, Budapest, Hungary.
| | - Pâl Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68 Varosmajor Street, 1122, Budapest, Hungary.
| | - Udo Hoffmann
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.
| | - Brian Ghoshhajra
- Cardiovascular Imaging, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.
| |
Collapse
|
19
|
Huang W, Xu Y, Lu D, Shi Y, Lu G. Single- versus multi-phase acquisition protocol for prospective-triggered sequential dual-source CT coronary angiography: comparison of image quality and radiation dose. Clin Imaging 2015; 39:597-602. [PMID: 25825344 DOI: 10.1016/j.clinimag.2015.02.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2014] [Revised: 02/17/2015] [Accepted: 02/24/2015] [Indexed: 01/07/2023]
Abstract
OBJECTIVE To investigate image quality and radiation dose of single- versus multi-phase acquisition protocol for prospective-triggered sequential dual-source computed tomography (CT) coronary angiography. MATERIALS AND METHODS A total of 140 patients were randomly assigned to single- or multi-phase group. Image quality and radiation dose were compared. RESULTS No significant difference was found in image quality between the two groups. Effective dose of single-phase group was 21.6% lower than that of multi-phase group (P<.001). CONCLUSIONS Prospective-triggered sequential dual-source CT coronary angiography using single-phase protocol can reduce radiation dose without sacrifice of image quality in diastole compared with multi-phase protocol.
Collapse
Affiliation(s)
- Wei Huang
- Department of Medical Imaging, Nanjing Jinling Hospital, Southern Medical University (Guangzhou), 305# Eastern Zhongshan Road, Nanjing 210002, China; Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China.
| | - Yiming Xu
- Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China
| | - Daoyan Lu
- Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China
| | - Yuzhen Shi
- Department of Medical Imaging, Huai'an First People's Hospital, Nanjing Medical University, 6# Western Beijing Road, Huai'an 223300, China
| | - Guangming Lu
- Department of Medical Imaging, Nanjing Jinling Hospital, Southern Medical University (Guangzhou), 305# Eastern Zhongshan Road, Nanjing 210002, China.
| |
Collapse
|
20
|
|
21
|
Vadvala H, Kim P, Mayrhofer T, Pianykh O, Kalra M, Hoffmann U, Ghoshhajra B. Coronary CTA using scout-based automated tube potential and current selection algorithm, with breast displacement results in lower radiation exposure in females compared to males. Cardiovasc Diagn Ther 2015; 4:470-9. [PMID: 25610804 DOI: 10.3978/j.issn.2223-3652.2014.12.07] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2014] [Accepted: 12/12/2014] [Indexed: 11/14/2022]
Abstract
PURPOSE To evaluate the effect of automatic tube potential selection and automatic exposure control combined with female breast displacement during coronary computed tomography angiography (CCTA) on radiation exposure in women versus men of the same body size. MATERIALS AND METHODS Consecutive clinical exams between January 2012 and July 2013 at an academic medical center were retrospectively analyzed. All examinations were performed using ECG-gating, automated tube potential, and tube current selection algorithm (APS-AEC) with breast displacement in females. Cohorts were stratified by sex and standard World Health Organization body mass index (BMI) ranges. CT dose index volume (CTDIvol), dose length product (DLP) median effective dose (ED), and size specific dose estimate (SSDE) were recorded. Univariable and multivariable regression analyses were performed to evaluate the effect of gender on radiation exposure per BMI. RESULTS A total of 726 exams were included, 343 (47%) were females; mean BMI was similar by gender (28.6±6.9 kg/m(2) females vs. 29.2±6.3 kg/m(2) males; P=0.168). Median ED was 2.3 mSv (1.4-5.2) for females and 3.6 (2.5-5.9) for males (P<0.001). Females were exposed to less radiation by a difference in median ED of -1.3 mSv, CTDIvol -4.1 mGy, and SSDE -6.8 mGy (all P<0.001). After adjusting for BMI, patient characteristics, and gating mode, females exposure was lower by a median ED of -0.7 mSv, CTDIvol -2.3 mGy, and SSDE -3.15 mGy, respectively (all P<0.01). CONCLUSIONS We observed a difference in radiation exposure to patients undergoing CCTA with the combined use of AEC-APS and breast displacement in female patients as compared to their BMI-matched male counterparts, with female patients receiving one third less exposure.
Collapse
Affiliation(s)
- Harshna Vadvala
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Phillip Kim
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Thomas Mayrhofer
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Oleg Pianykh
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Mannudeep Kalra
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Udo Hoffmann
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Brian Ghoshhajra
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
22
|
Low Radiation Coronary CT. CURRENT CARDIOVASCULAR IMAGING REPORTS 2014. [DOI: 10.1007/s12410-014-9284-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
23
|
Lee AM, Beaudoin J, Thai WE, Wai B, Hui GC, Sidhu MS, Engel LC, Abbara S, Hoffmann U, Ghoshhajra BB. Feasibility of aortic valve assessment with low dose prospectively triggered adaptive systolic (PTAS) cardiac computed tomography angiography. BMC Res Notes 2013; 6:158. [PMID: 23602055 PMCID: PMC3640955 DOI: 10.1186/1756-0500-6-158] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Accepted: 04/12/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cardiac computed tomography angiography (CTA) is feasible for aortic valve evaluation, but retrospective gated protocols required high radiation doses for aortic valve assessment. A prospectively triggered adaptive systolic (PTAS) cardiac CT protocol was recently described in arrhythmia using second-generation dual-source CT. In this study, we sought to evaluate the feasibility of PTAS CTA to assess the aortic valve at a low radiation dose. FINDINGS A retrospective cohort of 29 consecutive patients whom underwent PTAS protocols for clinical indications other than aortic valve assessment and whom also received echocardiography within 2 months of CT, was identified. Images were reviewed for aortic valve morphology (tricuspid/bicuspid/prosthetic) and stenosis (AS) by experienced blinded readers. Accuracy versus echocardiography and radiation doses were assessed. CONCLUSIONS PTAS CTA protocols using second-generation dual-source CT for aortic valve evaluation are feasible at low doses. This protocol should be investigated further in larger cohorts.
Collapse
|