1
|
Saad JM, Ahmed AI, Han Y, El Nihum LI, Alahdab F, Nabi F, Al-Mallah MH. Splenic switch-off in regadenoson 82Rb-PET myocardial perfusion imaging: assessment of clinical utility. J Nucl Cardiol 2023; 30:1484-1496. [PMID: 36607537 DOI: 10.1007/s12350-022-03158-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 11/05/2022] [Indexed: 01/07/2023]
Abstract
BACKGROUND Splenic switch-off (SSO) is a phenomenon describing a decrease in splenic radiotracer uptake after vasodilatory stress. We aimed to assess the diagnostic utility of regadenoson-induced SSO. METHODS We included consecutive patients who had clinically indicated Regadenoson Rb-82 PET-MPI for suspected CAD. This derivation cohort (no perfusion defects and myocardial flow reserves (MFR) ≥ 2) was used to calculate the splenic response ratio (SRR). The validation cohort was defined as patients who underwent both PET-MPI studies and invasive coronary angiography (ICA). RESULTS The derivation cohort (n = 100, 57.4 ± 11.6 years, 77% female) showed a decrease in splenic uptake from rest to stress (79.9 ± 16.8 kBq⋅mL vs 69.1 ± 16.2 kBq⋅mL, P < .001). From the validation cohort (n = 315, 66.3 ± 10.4 years, 67% male), 28% (via SRR = 0.88) and 15% (visually) were classified as splenic non-responders. MFR was lower in non-responders (SRR; 1.55 ± 0.65 vs 1.76 ± 0.78, P = .02 and visually; 1.18 ± 0.33 vs 1.79 ± 0.77, P < .001). Based on ICA, non-responders were more likely to note obstructive epicardial disease with normal PET scans especially in patients with MFR < 1.5 (SRR; 61% vs 34% P = .05 and visually; 68% vs 33%, P = .01). CONCLUSION Lack of splenic response based on visual or quantitative assessment of SSO may be used to identify an inadequate vasodilatory response.
Collapse
Affiliation(s)
- Jean Michel Saad
- Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, USA
| | | | - Yushui Han
- Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, USA
| | | | - Fares Alahdab
- Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, USA
| | - Faisal Nabi
- Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, USA
| | - Mouaz H Al-Mallah
- Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, USA.
| |
Collapse
|
2
|
Bakula A, Patriki D, von Felten E, Benetos G, Sustar A, Benz DC, Wiedemann-Buser M, Treyer V, Pazhenkottil AP, Gräni C, Gebhard C, Kaufmann PA, Buechel RR, Fuchs TA. Splenic switch-off as a novel marker for adenosine response in nitrogen-13 ammonia PET myocardial perfusion imaging: Cross-validation against CMR using a hybrid PET/MR device. J Nucl Cardiol 2022; 29:1205-1214. [PMID: 33354759 PMCID: PMC9163112 DOI: 10.1007/s12350-020-02448-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 11/09/2020] [Indexed: 11/29/2022]
Abstract
BACKGROUND No methodology is available to distinguish truly reduced myocardial flow reserve (MFR) in positron emission tomography myocardial perfusion imaging (PET MPI) from seemingly impaired MFR due to inadequate adenosine response. The adenosine-induced splenic switch-off (SSO) sign has been proposed as a potential marker for adequate adenosine response in cardiac magnetic resonance (CMR). We assessed the feasibility of detecting SSO in nitrogen-13 ammonia PET MPI using SSO in CMR as the standard of reference. METHODS AND RESULTS Fifty patients underwent simultaneous CMR and PET MPI on a hybrid PET/MR device with co-injection of a gadolinium-based contrast agent and nitrogen-13 ammonia during rest and adenosine-induced stress. In CMR, SSO was assessed visually (positive vs negative SSO) and quantitatively by calculating the ratio of the peak signal intensity of the spleen during stress over rest (SIR). In PET MPI, the splenic signal activity ratio (SAR) was calculated as the maximal standard uptake value of the spleen during stress over rest. The median SIR was significantly lower in patients with positive versus negative SSO in CMR (0.57 [IQR 0.49 to 0.62] vs 0.89 [IQR 0.76 to 0.98]; P < .001). Similarly, median SAR in PET MPI was significantly lower in patients with positive versus negative SSO (0.40 [IQR 0.32 to 0.45] vs 0.80 [IQR 0.47 to 0.98]; P < .001). CONCLUSION Similarly to CMR, SSO can be detected in nitrogen-13 ammonia PET MPI. This might help distinguish adenosine non-responders from patients with truly impaired MFR due to microvascular dysfunction or multivessel coronary artery disease.
Collapse
Affiliation(s)
- Adam Bakula
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Dimitri Patriki
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Elia von Felten
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Georgios Benetos
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Aleksandra Sustar
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Dominik C Benz
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Muriel Wiedemann-Buser
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Valerie Treyer
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Aju P Pazhenkottil
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Christoph Gräni
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Catherine Gebhard
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Philipp A Kaufmann
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Ronny R Buechel
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Tobias A Fuchs
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
| |
Collapse
|
3
|
Farzaneh-Far A, Wong J. Stressed enough? Hyperaemic thresholds during quantitative cardiovascular magnetic resonance perfusion mapping. Eur Heart J Cardiovasc Imaging 2021; 22:282-284. [PMID: 33338199 DOI: 10.1093/ehjci/jeaa268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Indexed: 11/13/2022] Open
Affiliation(s)
- Afshin Farzaneh-Far
- Division of Cardiology, Department of Medicine, University of Illinois at Chicago, 840 South Wood St. M/C 715, Suite 920 S, Chicago, IL 60612, USA.,Division of Cardiology, Department of Medicine, Duke University, Durham, NC, USA
| | - Joyce Wong
- Department of Cardiology, Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, Harefield, UK
| |
Collapse
|
4
|
Patriki D, von Felten E, Bakula A, Giannopoulos AA, Kamani CH, Schwyzer M, Messerli M, Benz DC, Gebhard C, Gräni C, Pazhenkottil AP, Kaufmann PA, Fuchs TA, Buechel RR. Splenic switch-off as a predictor for coronary adenosine response: validation against 13N-ammonia during co-injection myocardial perfusion imaging on a hybrid PET/CMR scanner. J Cardiovasc Magn Reson 2021; 23:3. [PMID: 33407586 PMCID: PMC7789581 DOI: 10.1186/s12968-020-00696-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 12/09/2020] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Inadequate coronary adenosine response is a potential cause for false negative ischemia testing. Recently, the splenic switch-off (SSO) sign has been identified as a promising tool to ascertain the efficacy of adenosine during vasodilator stress cardiovascular magnetic resonance imaging (CMR). We assessed the value of SSO to predict adenosine response, defined as an increase in myocardial blood flow (MBF) during quantitative stress myocardial perfusion 13 N-ammonia positron emission tomography (PET). METHODS We prospectively enrolled 64 patients who underwent simultaneous CMR and PET myocardial perfusion imaging on a hybrid PET/CMR scanner with co-injection of gadolinium based contrast agent (GBCA) and 13N-ammonia during rest and adenosine-induced stress. A myocardial flow reserve (MFR) of > 1.5 or ischemia as assessed by PET were defined as markers for adequate coronary adenosine response. The presence or absence of SSO was visually assessed. The stress-to-rest intensity ratio (SIR) was calculated as the ratio of stress over rest peak signal intensity for splenic tissue. Additionally, the spleen-to-myocardium ratio, defined as the relative change of spleen to myocardial signal, was calculated for stress (SMRstress) and rest. RESULTS Sixty-one (95%) patients were coronary adenosine responders, but SSO was absent in 18 (28%) patients. SIR and SMRstress were significantly lower in patients with SSO (SIR: 0.56 ± 0.13 vs. 0.93 ± 0.23; p < 0.001 and SMRstress: 1.09 ± 0.47 vs. 1.68 ± 0.62; p < 0.001). Mean hyperemic and rest MBF were 2.12 ± 0.68 ml/min/g and 0.78 ± 0.26 ml/min/g, respectively. MFR was significantly higher in patients with vs. patients without presence of SSO (3.07 ± 1.03 vs. 2.48 ± 0.96; p = 0.038), but there was only a weak inverse correlation between SMRstress and MFR (R = -0.378; p = 0.02) as well as between SIR and MFR (R = -0.356; p = 0.004). CONCLUSIONS The presence of SSO implies adequate coronary adenosine-induced MBF response. Its absence, however, is not a reliable indicator for failed adenosine-induced coronary vasodilatation.
Collapse
Affiliation(s)
- Dimitri Patriki
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Elia von Felten
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Adam Bakula
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Andreas A Giannopoulos
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Christel H Kamani
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Moritz Schwyzer
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Michael Messerli
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Dominik C Benz
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Catherine Gebhard
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Christoph Gräni
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Aju P Pazhenkottil
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Philipp A Kaufmann
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Tobias A Fuchs
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Ronny R Buechel
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich and University Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
| |
Collapse
|
5
|
Saeed M. Editorial for: “Splenic Switch‐Off for Determining the Optimal Dosage for Adenosine Stress Cardiovascular MR in Terms of Stress Effectiveness and Patient Safety”. J Magn Reson Imaging 2020; 52:1743-1744. [DOI: 10.1002/jmri.27252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Accepted: 05/26/2020] [Indexed: 11/09/2022] Open
Affiliation(s)
- Maythem Saeed
- Department of Radiology and Biomedical Imaging, School of Medicine University of California San Francisco San Francisco California USA
| |
Collapse
|
6
|
van Assen M, Kuijpers DJ, Schwitter J. MRI perfusion in patients with stable chest-pain. Br J Radiol 2020; 93:20190881. [PMID: 31834813 PMCID: PMC7465855 DOI: 10.1259/bjr.20190881] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 12/10/2019] [Accepted: 12/11/2019] [Indexed: 12/27/2022] Open
Abstract
Perfusion-cardiovascular MR (CMR) imaging has been shown to reliably identify patients with suspected or known coronary artery disease (CAD), who are at risk for future cardiac events and thus, allows for guiding therapy including revascularizations. Accordingly, it is an ideal test to exclude prognostically relevant coronary artery disease. Several guidelines, such as the ESC guidelines, currently recommend CMR as non-invasive testing in patients with stable chest pain. CMR has as an advantage over the more conventional pathways as it lacks radiation and it potentially reduces costs.
Collapse
Affiliation(s)
- Marly van Assen
- University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Dirk Jan Kuijpers
- Department of Radiology, HMC-Bronovo, Haaglanden Medisch Centrum, Den Haag, the Netherlands
| | | |
Collapse
|
7
|
Rischpler C, Totzeck M. Are you stressed? J Nucl Cardiol 2019; 26:1898-1900. [PMID: 29948893 DOI: 10.1007/s12350-018-1332-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Accepted: 05/22/2018] [Indexed: 11/26/2022]
Affiliation(s)
- C Rischpler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.
| | - M Totzeck
- Department of Cardiology and Vascular Medicine, University Hospital Essen, West German Heart and Vascular Center, University of Duisburg, Essen, Germany
| |
Collapse
|
8
|
Reiber JHC, Pereira GTR, Bezerra HG, De Sutter J, Schoenhagen P, Stillman AE, Van de Veire NRL. Cardiovascular imaging 2018 in the International Journal of Cardiovascular Imaging. Int J Cardiovasc Imaging 2019; 35:1175-1188. [DOI: 10.1007/s10554-019-01579-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
9
|
Seitz A, Kaesemann P, Chatzitofi M, Löbig S, Tauscher G, Bekeredjian R, Sechtem U, Mahrholdt H, Greulich S. Impact of caffeine on myocardial perfusion reserve assessed by semiquantitative adenosine stress perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2019; 21:33. [PMID: 31230593 PMCID: PMC6589875 DOI: 10.1186/s12968-019-0542-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 05/20/2019] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Adenosine is used in stress perfusion cardiac imaging to reveal myocardial ischemia by its vasodilator effects. Caffeine is a competitive antagonist of adenosine. However, previous studies reported inconsistent results about the influence of caffeine on adenosine's vasodilator effect. This study assessed the impact of caffeine on the myocardial perfusion reserve index (MPRI) using adenosine stress cardiovascular magnetic resonance imaging (CMR). Moreover, we sought to evaluate if the splenic switch-off sign might be indicative of prior caffeine consumption. METHODS Semiquantitative perfusion analysis was performed in 25 patients who underwent: 1) caffeine-naïve adenosine stress CMR demonstrating myocardial ischemia and, 2) repeat adenosine stress CMR after intake of caffeine. MPRI (global; remote and ischemic segments), and splenic perfusion ratio (SPR) were assessed and compared between both exams. RESULTS Global MPRI after caffeine was lower vs. caffeine-naïve conditions (1.09 ± 0.19 vs. 1.24 ± 0.19; p < 0.01). MPRI in remote myocardium decreased by caffeine (1.24 ± 0.19 vs. 1.49 ± 0.19; p < 0.001) whereas MPRI in ischemic segments (0.89 ± 0.18 vs. 0.95 ± 0.23; p = 0.23) was similar, resulting in a lower MPRI ratio (=remote/ischemic segments) after caffeine consumption vs. caffeine-naïve conditions (1.41 ± 0.19 vs. 1.64 ± 0.35, p = 0.01). The SPR was unaffected by caffeine (SPR 0.38 ± 0.19 vs. 0.38 ± 0.18; p = 0.92). CONCLUSION Caffeine consumption prior to adenosine stress CMR results in a lower global MPRI, which is driven by the decreased MPRI in remote myocardium and underlines the need of abstinence from caffeine. The splenic switch-off sign is not affected by prior caffeine intake.
Collapse
Affiliation(s)
- Andreas Seitz
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Philipp Kaesemann
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Maria Chatzitofi
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Stephanie Löbig
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Gloria Tauscher
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Raffi Bekeredjian
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Udo Sechtem
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Heiko Mahrholdt
- Department of Cardiology, Robert Bosch Medical Center, Auerbachstraße 110, 70376 Stuttgart, Germany
| | - Simon Greulich
- Department of Cardiology and Angiology, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
10
|
Reiter U, Reiter C, Kräuter C, Fuchsjäger M, Reiter G. Cardiac magnetic resonance T1 mapping. Part 2: Diagnostic potential and applications. Eur J Radiol 2018; 109:235-247. [PMID: 30539759 DOI: 10.1016/j.ejrad.2018.10.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 10/07/2018] [Accepted: 10/15/2018] [Indexed: 02/07/2023]
Abstract
Non-invasive identification and differentiation of myocardial diseases represents the primary objectives of cardiac magnetic resonance (CMR) longitudinal relaxation time (T1) and extracellular volume (ECV) mapping. Given the fact that myocardial T1 and ECV values overlap throughout and within left ventricular phenotypes, a central issue to be addressed is whether and to what extent myocardial T1 and ECV mapping provides additional or superior diagnostic information to standard CMR imaging, and whether native T1 mapping could be employed as a non-contrast alternative to late gadolinium enhancement (LE) imaging. The present review aims to summarize physiological and pathophysiological alterations in native T1 and ECV values and summarized myocardial T1 and ECV alterations associated with cardiac diseases to support the translation of research findings into routine CMR imaging.
Collapse
Affiliation(s)
- Ursula Reiter
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 19/P, 8036 Graz, Austria.
| | - Clemens Reiter
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 19/P, 8036 Graz, Austria.
| | - Corina Kräuter
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 19/P, 8036 Graz, Austria; Institute of Medical Engineering, Graz University of Technology, Stremayrgasse 16/III, 8010 Graz, Austria.
| | - Michael Fuchsjäger
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 19/P, 8036 Graz, Austria.
| | - Gert Reiter
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 19/P, 8036 Graz, Austria; Research & Development, Siemens Healthcare Diagnostics GmbH, Strassgangerstrasse 315, 8054 Graz, Austria.
| |
Collapse
|