1
|
Gökler DJ, Karácsony AF, Faragó D, Szebényi G, Kiss RM, Pap K. The effect of sterilization and storage on the viscoelastic properties of human tendon allografts - Continued: Storage for 0 to 4 months. J Biomech 2024; 162:111904. [PMID: 38134466 DOI: 10.1016/j.jbiomech.2023.111904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 12/09/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
The role of donor-derived tendons, also known as allografts, in anterior cruciate ligament replacement surgeries is steadily increasing. Before surgery, temporary storage and, in most cases, sterilization are essential. It is, thus, crucial to determine how these procedures alter the grafts' biomechanical properties. The purpose of this research was to analyze the effect of different sterilization methods (native, frozen, frozen + 21 kGy gamma irradiation, frozen + 21 kGy electron beam irradiation) and storage durations (0 to 4 months) on the deformation and creep of two tendon types (tibialis anterior, peroneus longus). 80 tibialis anterior and 83 peroneus longus tendons from 51 human cadavers were included. The samples were removed, placed in a radio-cryoprotectant solution, then slowly cooled, sterilized and stored at -80 °C. All groups were subject to 60 s static creep test with 250 N load. Deformation during the loading phase, creep during static loading, and the ratio of these two were evaluated. Deformation at the end of the loading phase and creep consistently exhibited significantly smaller values in the tibialis anterior compared to the peroneus longus type, as well as in electron beam-sterilized grafts as opposed to gamma beam-sterilized ones. Prolonged storage periods (within 0 to 4 months) resulted in a notable increase in these values, particularly in deformation. Based on the experimental data, the tibialis anterior tendon type and sterilization by gamma beam irradiation are better choices for anterior cruciate ligament reconstruction than the peroneus longus and sterilization by electron beam. Increased storage time affects negatively the evaluated mechanical properties.
Collapse
Affiliation(s)
- Daniella Judit Gökler
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Atilla Ferenc Karácsony
- Semmelweis University Budapest, Department of Traumatology, Hungary; Buda Hospital of the Hospitaller Order of Saint John of God, Department of Orthopedics, Hungary
| | - Dénes Faragó
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Gábor Szebényi
- MTA-BME Lendület Lightweight Polymer Composites Research Group, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Polymer Engineering, Hungary.
| | - Rita Mária Kiss
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Károly Pap
- Semmelweis University Budapest, Department of Traumatology, Hungary; Uzsoki Hospital, Department of Orthopedics and Traumatology, Hungary
| |
Collapse
|
2
|
Farago D, Kozma B, Kiss RM. Categorize the existing clamps used for tensile test of human graft- a systematic review. BMC Musculoskelet Disord 2022; 23:707. [PMID: 35879684 PMCID: PMC9316330 DOI: 10.1186/s12891-022-05650-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
Background The use of tendon allografts for orthopedic repair has gained wide acceptance in recent years, most notably in anterior cruciate tendon reconstruction. Multiple studies support the use of tendon allografts and the benefits of its use are well accepted and understood. One of the important criteria of the use of tendon allografts is statistically similar histological and biomechanical properties to autographs. The aim of this systematic literature review is to investigate and categorize existing clamps used in the determination of the biomechanical properties of tendons such as maximum load, maximum strength, modulus of elasticity, ultimate strain, and stiffness. A variety of clamps for use during the endurance test of tendons were categorized according to the temperature used during the measurement. The clamps are divided into three groups: room temperature, cooled and heated clamps. The second goal of our review is to overview of clamps on the following aspects: name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters, and summarize in Table 3, as a comprehensive catalogue. Methods This systematic review was carried out in keeping with the PRISMA 2020 E&E and the PRISMA-S guidelines and checklists. A search was conducted for publications dating between 1991 and February 28th 2022 through three electronic databases (Web of Science, Scopus, and PubMed). We used Critical Appraisal Skills Program checklist to check the quality of included articles. Results The database search and additional sources resulted in 1725 records. 1635 records eliminated during the screening for various reasons (case report, other languages, book chapter, unavailable text/conference abstract, unrelated topic). The number of articles used in the final synthesis was 90. A variety of clamps for use during the endurance test of tendons were identified and categorized according to the temperature used during the measurement. Based on this, the clamps are divided into three groups: room temperature, cooled or heated clamps. Conclusions On the basis of the systematic literature review, mechanical parameters determined by usage with cooled clamps proved to be more reliable than with those at room temperature and with heated clamps. The collected information from the articles included name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters given in Table 3. summarized. The main advantage of the cooled clamps is that there is no limit to the type and length of the tendon. This study provides an overview of clamps and does not represent the modernity of any method. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05650-w.
Collapse
Affiliation(s)
- Denes Farago
- Cooperation Research Center for Biomechanics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary. .,Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary.
| | - Blanka Kozma
- Department of Biomedical Engineering, SUNY University at Buffalo, Buffalo, USA
| | - Rita Maria Kiss
- Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary
| |
Collapse
|
3
|
Heredia Rivera U, Kadian S, Nejati S, White J, Sedaghat S, Mutlu Z, Rahimi R. Printed Low-Cost PEDOT:PSS/PVA Polymer Composite for Radiation Sterilization Monitoring. ACS Sens 2022; 7:960-971. [PMID: 35333058 DOI: 10.1021/acssensors.1c02105] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
During the γ-radiation sterilization process, the levels of radiation exposure to a medical device must be carefully monitored to achieve the required sterilization without causing deleterious effects on its intended physical and chemical properties. To address this issue, here we have demonstrated the development of an all-printed disposable low-cost sensor that exploits the change in electrical impedance of a semi-interpenetrating polymer network (SIPN) composed of poly(vinyl alcohol) (PVA) and poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) as a functional polymer composite for radiation sterilization monitoring applications. Specifically, the PEDOT:PSS acts as the electrically conductive medium, while the PVA provides the ductility and stability of the printed sensors. During irradiation exposure, chain scission and cross-linking events occur concurrently in the PEDOT:PSS and PVA polymer chains, respectively. The concurrent scissoring of the PEDOT polymer and cross-linking of the PVA polymer network leads to the formation of a stable SIPN with reduced electrical conductivity, which was verified through FTIR, Raman, and TGA analysis. Systematic studies of different ratios of PEDOT:PSS and PVA mixtures were tested to identify the optimal ratio that provided the highest radiation sensitivity and stability performance. The results showed that PEDOT:PSS/PVA composites with 10 wt % PVA produced sensors with relative impedance changes of 30% after 25 kGy and up to 370% after 53 kGy (which are two of the most commonly used radiation exposure levels for sterilization applications). This composition showed high electrical impedance stability with less than ±5% change over 18 days after irradiation exposure. These findings demonstrate the feasibility of utilizing a printing technology for scalable manufacturing of low-cost, flexible radiation sensors for more effective monitoring of radiation sterilization processes.
Collapse
Affiliation(s)
- Ulisses Heredia Rivera
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Sachin Kadian
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Sina Nejati
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Julia White
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Sotoudeh Sedaghat
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Zeynep Mutlu
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Rahim Rahimi
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
4
|
Gökler DJ, Faragó D, Szebényi G, Kiss RM, Pap K. The effect of sterilization and storage on the viscoelastic properties of human tendon allografts. J Biomech 2021; 127:110697. [PMID: 34419827 DOI: 10.1016/j.jbiomech.2021.110697] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 11/17/2022]
Abstract
Allografts have become increasingly preferred for anterior cruciate ligament replacement purposes. The risk of infections necessitates thorough sterilization procedures, and the allografts usually need to be stored prior to surgery. Classical mechanical tests have been performed with various types of tendons, however, tibialis anterior and peroneus longus tend to suffer the least biomechanical changes after irradiation. Only few results are available of the strain and creep behaviour of tendons, even though this information is necessary to provide suitable allografts. The aim of the present study is to analyze the effect of different tendon types (T-tibialis anterior, P-peroneus longus), sterilization methods (G-gamma irradiation of 21 kGy, E-electron beam irradiation of 21 kGy) and storage times (5 and 6 months) on the creep behavior, which is characterized by the strain at the end of the loading phase and creep deformation after static loading. Static creep tests were performed with 250 N load during 60 s. Deformation at the end of the loading phase of both tendons was significantly smaller after 5 months long storage than that after 6 months long storage. TE5 showed significantly less creep than group TE6, and TE6 significantly greater than PE6. The creep of TE5 was significantly lower than that of TG5. Based on the data, the peroneus longus sterilized by electron beam and stored deep frozen for 5 months is a better choice for anterior cruciate ligament reconstruction than tibialis anterior sterilized by gamma irradiation stored for 6 months.
Collapse
Affiliation(s)
- Daniella Judit Gökler
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Dénes Faragó
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Biomechanical Research Centre, Hungary
| | - Gábor Szebényi
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Biomechanical Research Centre, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Polymer Engineering, Hungary
| | - Rita Mária Kiss
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Biomechanical Research Centre, Hungary.
| | - Károly Pap
- Semmelweis University Budapest, Department of Traumatology, Hungary; Uzsoki Hospital, Department of Orthopedics and Traumatology, Hungary
| |
Collapse
|
5
|
Shang X, Wang H, Li J, Li Q. [Progress of sterilization and preservation methods for allografts in anterior cruciate ligament reconstruction]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2019; 33:1102-1107. [PMID: 31512450 PMCID: PMC8355842 DOI: 10.7507/1002-1892.201903078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 08/07/2019] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To review the current status and progress of sterilization and preservation for allograft in anterior cruciate ligament reconstruction. METHODS The related literature about the sterilization and preservation of allografts in anterior cruciate ligament reconstruction was extensively reviewed and summarized. RESULTS There are many sterilization methods for allografts, the most commonly used method is γ-ray irradiation, but the optimal irradiation dose is still unclear. Electron beam irradiation is also available, but excessive dose is harmful to graft shaping. A combined sterilization method combining physics and chemistry methods is still being explored. Cryopreservation is the most commonly used method of preservation. In order to reduce the influence of crystals, the principle of "slow cooling and rapid rewarming" should be adhered to as far as possible. CONCLUSION The processing methods of allograft can affect the effectiveness of anterior cruciate ligament reconstruction. The clinical doctors should consider the sterilization and preservation methods in practice.
Collapse
Affiliation(s)
- Xiaoke Shang
- Department of Orthopedics, People's Hospital of Ningxia Hui Autonomous Region, Yinchuan Ningxia, 750000, P.R.China
| | - Huihui Wang
- Sports Medicine Center of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Jian Li
- Sports Medicine Center of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P.R.China
| | - Qi Li
- Sports Medicine Center of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041,
| |
Collapse
|
6
|
Biomechanical considerations are crucial for the success of tendon and meniscus allograft integration-a systematic review. Knee Surg Sports Traumatol Arthrosc 2019; 27:1708-1716. [PMID: 30291394 DOI: 10.1007/s00167-018-5185-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 09/27/2018] [Indexed: 01/20/2023]
Abstract
PURPOSE This systematic review intends to give an overview of the current knowledge on how allografts used for the reconstruction of cruciate ligaments and menisci are integrated and specifically perform regarding their biomechanical function. METHODS Two reviewers reviewed the PubMed and Central Cochrane library with focus on the biomechanical integration of tendon ligament and meniscus allografts. The literature search was conducted in accordance with the PRISMA statement for reporting systematic reviews and meta-analyses. RESULTS The analysed literature on tendon allografts shows that they are more vulnerable to overstretching in the phase of degradation compared to autografts as the revascularization process starts later and takes longer. Therefore, to avoid excessive graft loads, allografts for cruciate ligament replacement should be selected that exhibit much higher failure loads than the native ligaments to counteract the detrimental effect of degradation. Further, placement techniques should be considered that result in a minimum of strain differences during knee joint motion, which is best achieved by near-isometric placement. The most important biomechanical parameters for meniscus allograft transplantation are secure fixation and proper graft sizing. Allograft attachment by bone plugs or by a bone block is superior to circumferential suturing and enables the allograft to restore the chondroprotective biomechanical function. Graft sizing is also of major relevance, because too small grafts are not able to compensate the knee joint incongruity and too large grafts may fail due to extrusion. Only adequate sizing and fixation together can lead to a biomechanically functioning allograft. The objective assessment of the biomechanical quality of allografts in a clinical setting is challenging, but would be highly desirable for monitoring the remodelling and incorporation process. CONCLUSIONS Currently, indicators like ap-stability after ACL reconstruction or meniscal extrusion represent only indirect measures for biomechanical graft integration. These parameters are at best clinical indicators of allograft function, but the overall integration properties comprising e.g. fixation and graft stiffness remain unknown. Therefore, future research should e.g. focus on advanced imaging techniques or other non-invasive methods allowing for in vivo assessment of biomechanical allograft properties.
Collapse
|
7
|
Singh R, Singh D, Singh A. Radiation sterilization of tissue allografts: A review. World J Radiol 2016; 8:355-369. [PMID: 27158422 PMCID: PMC4840193 DOI: 10.4329/wjr.v8.i4.355] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Revised: 12/05/2015] [Accepted: 01/19/2016] [Indexed: 02/06/2023] Open
Abstract
Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts.
Collapse
|
8
|
Helder MRK, Hennessy RS, Spoon DB, Tefft BJ, Witt TA, Marler RJ, Pislaru SV, Simari RD, Stulak JM, Lerman A. Low-Dose Gamma Irradiation of Decellularized Heart Valves Results in Tissue Injury In Vitro and In Vivo. Ann Thorac Surg 2015; 101:667-74. [PMID: 26453425 DOI: 10.1016/j.athoracsur.2015.07.080] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2015] [Revised: 07/13/2015] [Accepted: 07/28/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Decellularized heart valves are emerging as a potential alternative to current bioprostheses for valve replacement. Whereas techniques of decellularization have been thoroughly examined, terminal sterilization techniques have not received the same scrutiny. METHODS This study evaluated low-dose gamma irradiation as a sterilization method for decellularized heart valves. Incubation of valves and transmission electron microscopy evaluation after different doses of gamma irradiation were used to determine the optimal dose of gamma irradiation. Quantitative evaluation of mechanical properties was done by tensile mechanical testing of isolated cusps. Sterilized decellularized heart valves were tested in a sheep model (n = 3 [1 at 1,500 Gy and 2 at 3,000 Gy]) of pulmonary valve replacement. RESULTS Valves sterilized with gamma radiation between 1,000 Gy and 3,000 Gy were found to be optimal with in vitro testing. However, in vivo testing showed deteriorating valve function within 2 months. On explant, the valve with 1,500 Gy gamma irradiation showed signs of endocarditis with neutrophils on hematoxylin and eosin staining, and positive gram stain resembling streptococcus infection. The 3,000 Gy valves had no evidence of infection, but the hematoxylin and eosin staining showed evidence of wound remodeling with macrophages and fibroblasts. Tensile strength testing showed decreased strength (0 Gy: 2.53 ± 0.98 MPa, 1,500 Gy: 2.03 ± 1.23 MPa, and 3,000 Gy: 1.26 ± 0.90 MPa) with increasing levels of irradiation. CONCLUSIONS Low-dose gamma irradiation does not maintain the mechanical integrity of valves, and the balance between sterilization and damage may not be able to be achieved with gamma irradiation. Other methods of terminal sterilization must be pursued and evaluated.
Collapse
Affiliation(s)
| | - Ryan S Hennessy
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Daniel B Spoon
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Brandon J Tefft
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Tyra A Witt
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | | | - Sorin V Pislaru
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - Robert D Simari
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| | - John M Stulak
- Division of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota
| | - Amir Lerman
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota.
| |
Collapse
|
9
|
|
10
|
Radioprotective effect of N-acetyl-L-cysteine free radical scavenger on compressive mechanical properties of the gamma sterilized cortical bone of bovine femur. Cell Tissue Bank 2014; 16:97-108. [PMID: 24737302 DOI: 10.1007/s10561-014-9446-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Accepted: 04/01/2014] [Indexed: 12/30/2022]
Abstract
Gamma sterilization of bone allografts is used as a gold standard method to provide safety against disease transmission. However, it is well documented that high dose levels of ionizing radiation can degrade bone mechanical properties. This effect, which is attributed to the formation of free radicals through radiolysis of the water content of collagen, can lead to post-implantation difficulties such as pre-failure and/or secondary fractures of bone allografts. Recently, treatment of irradiated allografts with free radical scavengers is used to protect them against radiation-induced damages. This study aimed to investigate the radioprotective role of N-acetyl-L-cysteine (NAC) during the gamma sterilization of the cortical bone of bovine femurs using the compressive test. Totally, 195 cubic specimens with a dimension of 5 × 5 × 3 cubic mm were divided into 13 groups including a control and 12 experimental groups exposed to 18, 36, and 70 kGy at three different NAC concentrations (1.25, 12.5, and 25 mM for 18 kGy; 5, 50, and 100 mM for 36 kGy; 10, 100, and 200 mM for 70 kGy). The mechanical behavior of the sterilized specimens was studied using the uniaxial compressive test. The results indicated a concentration-dependent radioprotection effect of NAC on the plastic properties of the cortical bones. The concentration dependency of NAC was in turn related to radiation dose levels. In conclusion, treatment of bone specimens with a characteristic concentration of NAC during exposure to specific radiation dose levels can provide an efficient radioprotection window for preserving the mechanical stability of gamma sterilized allografts.
Collapse
|
11
|
Delgado LM, Pandit A, Zeugolis DI. Influence of sterilisation methods on collagen-based devices stability and properties. Expert Rev Med Devices 2014; 11:305-14. [PMID: 24654928 DOI: 10.1586/17434440.2014.900436] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Sterilisation is essential for any implantable medical device in order to prevent infection in patients. The selection of the most appropriate sterilisation method depends on the nature and the physical state of the material to be sterilised; the influence of the sterilisation method on the properties of the device; and the type of the potential contaminant. In this context, herein we review the influence of ethylene oxide, γ-irradiation, e-beam irradiation, gas plasma, peracetic acid and ethanol on structural, biomechanical, biochemical and biological properties of collagen-based devices. Data to-date demonstrate that chemical approaches are associated with cytotoxicity, whilst physical methods are associated with degradation, subject to the device physical characteristics. Thus, the sterilisation method of choice is device dependent.
Collapse
Affiliation(s)
- Luis M Delgado
- Network of Excellence for Functional Biomaterials (NFB), National University of Ireland Galway (NUI Galway), Galway, Ireland
| | | | | |
Collapse
|
12
|
Seto AU, Culp BM, Gatt CJ, Dunn M. Radioprotection provides functional mechanics but delays healing of irradiated tendon allografts after ACL reconstruction in sheep. Cell Tissue Bank 2013; 14:655-65. [PMID: 23842952 DOI: 10.1007/s10561-013-9385-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 06/22/2013] [Indexed: 12/21/2022]
Abstract
Successful protection of tissue properties against ionizing radiation effects could allow its use for terminal sterilization of musculoskeletal allografts. In this study we functionally evaluate Achilles tendon allografts processed with a previously developed radioprotective treatment based on (1-ethyl-3-(3-dimethylaminopropyl)carbodiimide) crosslinking and free radical scavenging using ascorbate and riboflavin, for ovine anterior cruciate ligament reconstruction. Arthroscopic anterior cruciate ligament (ACL) reconstruction was performed using double looped allografts, while comparing radioprotected irradiated and fresh frozen allografts after 12 and 24 weeks post-implantation, and to control irradiated grafts after 12 weeks. Radioprotection was successful at preserving early subfailure mechanical properties comparable to fresh frozen allografts. Twelve week graft stiffness and anterior-tibial (A-T) translation for radioprotected and fresh frozen allografts were comparable at 30 % of native stiffness, and 4.6 and 5 times native A-T translation, respectively. Fresh frozen allograft possessed the greatest 24 week peak load at 840 N and stiffness at 177 N/mm. Histological evidence suggested a delay in tendon to bone healing for radioprotected allografts, which was reflected in mechanical properties. There was no evidence that radioprotective treatment inhibited intra-articular graft healing. This specific radioprotective method cannot be recommended for ACL reconstruction allografts, and data suggest that future efforts to improve allograft sterilization procedures should focus on modifying or eliminating the pre-crosslinking procedure.
Collapse
Affiliation(s)
- Aaron U Seto
- Department of Orthopaedic Surgery, Robert Wood Johnson Medical School - Rutgers University, 51 French St MEB Rm 424, P.O. Box 19, New Brunswick, NJ, 08901, USA
| | | | | | | |
Collapse
|