1
|
Fang Z, Bi S, Brown JD, Chen J, Pan T. Microfluidics in the eye: a review of glaucoma implants from an engineering perspective. LAB ON A CHIP 2023; 23:4736-4772. [PMID: 37847237 DOI: 10.1039/d3lc00407d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Glaucoma is a progressive optic neuropathy in the eye, which is a leading cause of irreversible blindness worldwide and currently affects over 70 million individuals. Clinically, intraocular pressure (IOP) reduction is the only proven treatment to halt the progression of glaucoma. Microfluidic devices such as glaucoma drainage devices (GDDs) and minimally invasive glaucoma surgery (MIGS) devices are routinely used by ophthalmologists to manage elevated IOP, by creating an artificial pathway for the over-accumulated aqueous humor (AH) in a glaucomatous eye, when the natural pathways are severely blocked. Herein, a detailed modelling and analysis of both the natural microfluidic pathways of the AH in the eye and artificial microfluidic pathways formed additionally by the various glaucoma implants are conducted to provide an insight into the causes of the IOP abnormality and the improvement schemes of current implant designs. The mechanisms of representative glaucoma implants have been critically reviewed from the perspective of microfluidics, and we have categorized the current implants into four groups according to the targeted drainage sites of the AH, namely Schlemm's canal, suprachoroidal space, subconjunctival space, and ocular surface. In addition, we propose to divide the development and evolution of glaucoma implant designs into three technological waves, which include microtube (1st), microvalve (2nd) and microsystem (3rd). With the emerging trends of minimal invasiveness and artificial intelligence in the development of medical implants, we envision that a comprehensive glaucoma treatment microsystem is on the horizon, which is featured with active and wireless control of IOP, real-time continuous monitoring of IOP and aqueous rate, etc. The current review could potentially cast light on the unmatched needs, challenges, and future directions of the microfluidic structural and functional designs of glaucoma implants, which would enable an enhanced safety profile, reduced complications, increased efficacy of lowering IOP and reduced IOP fluctuations, closed-loop and on-demand control of IOP, etc.
Collapse
Affiliation(s)
- Zecong Fang
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
| | - Shuzhen Bi
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
| | | | - Junyi Chen
- Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia, Chinese Academy of Medical Sciences, and Shanghai Key Laboratory of Visual Impairment and Restoration (Fudan University), Shanghai, 200031, China
| | - Tingrui Pan
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|
2
|
Chan PPM, Larson MD, Dickerson JE, Mercieca K, Koh VTC, Lim R, Leung EHY, Samuelson TW, Larsen CL, Harvey A, Töteberg-Harms M, Meier-Gibbons F, Shu-Wen Chan N, Sy JB, Mansouri K, Zhang X, Lam DSC. Minimally Invasive Glaucoma Surgery: Latest Developments and Future Challenges. Asia Pac J Ophthalmol (Phila) 2023; 12:537-564. [PMID: 38079242 DOI: 10.1097/apo.0000000000000646] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 10/12/2023] [Indexed: 12/21/2023] Open
Abstract
The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.
Collapse
Affiliation(s)
- Poemen P M Chan
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
- Department of Ophthalmology and Visual Sciences, Lam Kin Chung. Jet King-Shing Ho Glaucoma Treatment and Research Centre, The Chinese University of Hong Kong, Hong Kong, China
| | | | - Jaime E Dickerson
- Sight Sciences, Menlo Park, CA, USA
- University of North Texas Health Science Center, North Texas Eye Research Institute, Fort Worth, TX, USA
| | | | - Victor Teck Chang Koh
- Department of Ophthalmology, National University Health System, Singapore
- Centre for Innovation and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ridia Lim
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Enne Hiu Ying Leung
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
| | - Thomas W Samuelson
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | - Christine L Larsen
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | | | - Marc Töteberg-Harms
- Department of Ophthalmology, Augusta University, Medical College of Georgia, Augusta, GA, USA
| | | | | | - Jessica Belle Sy
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Baguio General Hospital and Medical Center, Baguil City, Benguet, Philippines
| | - Kaweh Mansouri
- Glaucoma Center, Swiss Visio, Clinique de Montchoisi, Lausanne, Switzerland
| | - Xiulan Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Dennis S C Lam
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
- The International Eye Research Institute of The Chinese University of Hong Kong (Shenzhen), Shenzhen, China
| |
Collapse
|
3
|
Traverso CE, Carassa RG, Fea AM, Figus M, Astarita C, Piergentili B, Vera V, Gandolfi S. Effectiveness and Safety of Xen Gel Stent in Glaucoma Surgery: A Systematic Review of the Literature. J Clin Med 2023; 12:5339. [PMID: 37629380 PMCID: PMC10455777 DOI: 10.3390/jcm12165339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 08/08/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023] Open
Abstract
Although topical medical therapy and selective-laser-trabeculoplasty represent the treatments of choice to reduce intraocular pressure, many patients do not achieve adequate glaucoma control; therefore, they require further options and eventually surgery. Trabeculectomy is still considered the gold standard, but the surgical management of glaucoma has undergone continuous advances in recent years, XEN-gel-stent has been introduced as a safer and less traumatic means of lowering intraocular pressure (IOP) in patients with open-angle glaucoma (OAG). This study aimed to review the effectiveness and safety of clinical data on XEN-stent in OAG patients with a Synthesis-Without-Meta-analysis (SWiM) methodology. A total of 339 studies were identified following a literature search adhering to PRISMA guidelines and, after evaluation, 96 studies are discussed. XEN63 and XEN45 device data were collected both short and long term. In addition, this document has evaluated different aspects related to the XEN implant, including: its role compared to trabeculectomy; the impact of mitomycin-C dose on clinical outcomes; postoperative management of the device; and the identification of potential factors that might predict its clinical outcomes. Finally, current challenges and future perspectives of XEN stent, such as its use in fragile or high myopia patients, were discussed.
Collapse
Affiliation(s)
- Carlo Enrico Traverso
- Eye Clinic, IRCCS San Martino Polyclinic Hospital, 16132 Genoa, Italy;
- Department of Neurosciences, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DiNOGMI), University of Genoa, 16126 Genoa, Italy
| | | | - Antonio Maria Fea
- Department of Surgical Sciences, University of Turin, 10122 Turin, Italy;
| | - Michele Figus
- Department of Surgical, Medical and Molecular Pathology and Critical Care Medicine, University of Pisa, 56126 Pisa, Italy
| | - Carlo Astarita
- AbbVie S.r.l., 04011 Campoverde, LT, Italy; (C.A.); (B.P.)
| | | | | | - Stefano Gandolfi
- Department of Medicine and Surgery, University of Parma, 43121 Parma, Italy;
| |
Collapse
|
4
|
Betzler BK, Lim SY, Lim BA, Yip VCH, Ang BCH. Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma-a systematic review and meta-analysis. Eye (Lond) 2023; 37:1047-1060. [PMID: 35347294 PMCID: PMC10101986 DOI: 10.1038/s41433-022-02022-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 01/31/2022] [Accepted: 03/10/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND The XEN45 Gel Stent is a subconjunctival filtering device that has demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported complications and interventions after XEN45 implantation in the treatment of open angle glaucoma (OAG). METHODS Pilot, cohort, observational studies, and randomised controlled trials that included at least ten patients undergoing ab interno or externo XEN45 surgery, with or without phacoemulsification were deemed eligible for inclusion. A meta-analysis of proportions with random-effect models was performed using the meta routine in R version 3.2.1. Outcomes included the rate of complications and post-operative interventions. RESULTS One hundred and fifty-two studies were identified on initial literature search and 33 were included in final analysis. Numerical hypotony was the most common post-operative complication, involving 20% of patients (95% CI: 10-31%). Post-operative gross hyphema occurred in 14% (95% CI: 7-22%) and transient intra-ocular pressure (IOP) spikes (>30 mmHg) in 13% (95% CI: 4-27%). Stent exposure occurred in 1% (95% CI: 0-2%). Stent migration occurred in 1% (95% CI: 0-3%). XEN45 revision and/or a second XEN45 implantation was performed in 5% of patients (95% CI: 3-7%). Stent relocation was performed in 3% (95% CI: 1-7%). A second glaucoma procedure was performed in 11% (95% CI: 8-15%). 26% underwent one (95% CI: 17-36%), 13% underwent two (95% CI: 5-24%) while 4% underwent three (95% CI: 2-6%) bleb needling procedures. 35% of patients (95% CI: 29-40%) required at least one needling. The average rate of needling per patient was 0.38 (95% CI: 0.20-0.59). However, there is a lack of high-quality data, with 8 of the 33 studies assessed to have a moderate to high risk of bias. CONCLUSIONS While literature suggests that XEN45 Gel Stent implantation is safe in the treatment of OAG, the overall current level of evidence is low and further studies are needed. More than a third of patients require at least one post-operative bleb needling procedure.
Collapse
Affiliation(s)
- Bjorn Kaijun Betzler
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Sheng Yang Lim
- Army Medical Services, Singapore Armed Forces, Singapore, Singapore
| | - Boon Ang Lim
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| | - Vivien Cherng Hui Yip
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| | - Bryan Chin Hou Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore.
- Department of Ophthalmology, Woodlands Health Campus, National Healthcare Group Eye Institute, Singapore, Singapore.
| |
Collapse
|
5
|
Ruparelia S, Sharif M, Shoham-Hazon N. Efficacy and Safety Outcomes of XEN Implantation and Gonioscopy-assisted Transluminal Trabeculotomy for the Management of Advanced Open-angle Glaucoma. J Curr Glaucoma Pract 2023; 17:63-67. [PMID: 37485457 PMCID: PMC10357019 DOI: 10.5005/jp-journals-10078-1394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 01/13/2023] [Indexed: 07/25/2023] Open
Abstract
Aim Minimally invasive glaucoma surgery (MIGS) is not typically used in patients with advanced-stage glaucoma. This study describes the outcomes and complications of patients with advanced open-angle glaucoma (OAG) who underwent XEN implantation with cataract surgery or gonioscopy-assisted transluminal trabeculotomy (GATT) with cataract surgery. Methods This retrospective study identified patients who had undergone XEN implantation or GATT for the management of advanced OAG. Outcomes included surgical success, intraocular pressure (IOP) reduction, number of topical IOP-lowering drops, visual field mean deviation (MD), best-corrected visual acuity (BCVA), and complications. Surgical success was defined as an IOP of <14 mm Hg and a 20% reduction at 12 months without topical IOP-lowering drops (complete success) or with topical IOP-lowering drops (qualified success). Results Exactly 70 eyes were enrolled in this study, including 35 who had undergone XEN implantation and 35 who had undergone GATT. The overall surgical success rate was 74.3% (26 of 35) for eyes that underwent XEN implantation and 71.4% (25 of 35) for eyes that underwent GATT. Percent IOP reduction from baseline to 12 months postoperatively was 48% in the XEN cohort and 32% in the GATT cohort. Significant reduction in the use of topical IOP-lowering drops was demonstrated for both XEN (3.26 ± 1.15-1.23 ± 1.28) (p < 0.001) and GATT (2.46 ± 1.12-0.43 ± 0.78) (p < 0.001) cohorts at 12 months postoperatively. The only complication reported was transient hyphema, which occurred in three patients from the XEN group and four from the GATT group, and resolved spontaneously. Conclusions Both XEN implantation and GATT may be safe and effective management options when treating patients with advanced OAG. However, larger sample sizes are required to make direct statistical comparisons between these techniques. Clinical significance In this study, XEN implantation and GATT combined with cataract surgery were each associated with favorable outcomes in patients with advanced OAG. How to cite this article Ruparelia S, Sharif M, Shoham-Hazon N. Efficacy and Safety Outcomes of XEN Implantation and Gonioscopy-assisted Transluminal Trabeculotomy for the Management of Advanced Open-angle Glaucoma. J Curr Glaucoma Pract 2023;17(2):63-67.
Collapse
Affiliation(s)
- Sunil Ruparelia
- Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Mohammed Sharif
- Faculty of Medicine, Dalhousie Medicine New Brunswick (DMNB), Dalhousie University, Saint John, New Brunswick, Canada
| | - Nir Shoham-Hazon
- Miramichi EyeNB Centre of Excellence, Miramichi, New Brunswick, Canada
| |
Collapse
|
6
|
Panarelli JF, Vera V, Sheybani A, Radcliffe N, Fiscella R, Francis BA, Smith OU, Noecker RJ. Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature. Clin Ophthalmol 2023; 17:25-46. [PMID: 36660309 PMCID: PMC9845068 DOI: 10.2147/opth.s390955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 12/19/2022] [Indexed: 01/06/2023] Open
Abstract
The Xen gel stent (Allergan Inc, an AbbVie company; Dublin, Ireland) was conceived as an option for patients requiring modest IOP reduction but for whom trabeculectomy was not yet indicated. As with any glaucoma surgery, establishing criteria for patient selection and identifying factors that contribute to a high likelihood of success are important. To help guide clinical decision-making, a systematic review of published studies on the gel stent was performed, with the goal of understanding postoperative outcomes based on clinical and patient factors. Results were organized around a series of pertinent clinical questions based on scenarios encountered in clinical practice. Criteria for including studies were intentionally broad, with the objective of simulating the diverse population of glaucoma patients encountered in real-world practice. Outcomes for IOP and medication reduction postoperatively were assessed in various analyses, including in eyes with various glaucoma types and severity; in eyes naïve to surgery as well as those with a history of prior incisional glaucoma surgery; and when surgery was performed as a standalone procedure or at the time of cataract surgery. The results of each of the various analyses were consistent in demonstrating that successful gel stent surgery achieved a postoperative IOP of approximately 14.0 mm Hg and reduction to fewer than 1 glaucoma medication. Additional data are shown on outcomes by method of implant (ab interno vs ab externo); intraoperative use of antifibrotics; and rates of needling in published studies.
Collapse
Affiliation(s)
- Joseph F Panarelli
- Department of Ophthalmology, New York University, New York, NY, USA,Correspondence: Joseph F Panarelli, Department of Ophthalmology, New York University, 222 E 41st St, 3rd Floor, New York, NY, 10017, USA, Email
| | | | - Arsham Sheybani
- Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | - Nathan Radcliffe
- Department of Ophthalmology, New York Eye and Ear Infirmary, New York, NY, USA
| | | | - Brian A Francis
- Department of Ophthalmology, Doheny Eye Institute, University of California Los Angeles, Los Angeles, CA, USA
| | | | - Robert J Noecker
- Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, CT, USA,Ophthalmic Consultants of Connecticut, Fairfield, CT, USA
| |
Collapse
|
7
|
Ali ZC, Moshin N, Hakim MT, Shankar V. Two-year Outcomes of XEN Implantation with Minimal Bleb Needling. J Curr Glaucoma Pract 2022; 16:79-83. [PMID: 36128083 PMCID: PMC9452704 DOI: 10.5005/jp-journals-10078-1363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Accepted: 01/11/2022] [Indexed: 12/02/2022] Open
Abstract
Aim Our study aims to report the 2 years outcomes of the XEN implant in a single unit, single surgeon setting with minimal bleb needling. Methods A retrospective cohort study was conducted. Inclusion criteria were patients who underwent implantation with a XEN device between May 2016 and December 2017. This included patients who underwent both combined phacoemulsification and intraocular lens implantation alongside XEN implantation and those who underwent XEN implantation alone. Data gathered included basic demographic data, best-corrected visual acuity (LogMAR), intraocular pressure (IOP) in mm Hg, mean deviation from their visual field test, and the number of IOP-lowering medications they were on. This information was recorded for their preoperative visit, and then at 6, 12, 18 and 24 months postoperatively. The primary outcome assessed was a complete success when the patient was without glaucoma medications and had an IOP of 18 mm Hg or less, but more importantly, this also had to equate to a 20% reduction in IOP compared to baseline. Qualified success was defined as the same change in IOP but with medications. Surgical failure is defined as those who required additional glaucoma surgery or those who did not obtain an IOP of 18 mm Hg alongside a 20% reduction in IOP compared to baseline. Results At 24 months follow-up 82.5% of patients were surgical successes. Complete surgical success was achieved in 27% of patients. Qualified surgical success was achieved in 55.6% of patients. Subgroup analysis of those undergoing XEN implantation on its own and those combined with phacoemulsification + IOL were similar. The rate of bleb needling was low at 4.5%. Complication rates were acceptable at 9.5%. Conclusion It is possible to get good IOP control with minimal postoperative bleb needling in patients who have undergone XEN implantation. Similar success rates are found in those undergoing combined procedures. Clinical Significance Bleb needling carries its own risks. Minimizing the number of bleb needling allows procedures to be reserved at a later date. Furthermore, our study shows that success rates are not affected by doing a combined procedure with phacoemulsification. How to cite this article Ali ZC, Moshin N, Hakim MT, et al. Two-year Outcomes of XEN Implantation with Minimal Bleb Needling. J Curr Glaucoma Pract 2022;16(2):79-83.
Collapse
Affiliation(s)
- Zaria C Ali
- Department of Medical Retina, Manchester Royal Eye Hospital, Manchester, United Kingdom
- Zaria C Ali, Department of Medical Retina, Manchester Royal Eye Hospital, Manchester, United Kingdom, Phone: +91 7715233383, e-mail:
| | - Nadeem Moshin
- Department of Ophthalmology, East Lancashire Teaching Hospitals, Blackburn, United Kingdom
| | - Mohamad T Hakim
- Department of Ophthalmology, East Lancashire Teaching Hospitals, Blackburn, United Kingdom
| | - Vikas Shankar
- Department of Ophthalmology, East Lancashire Teaching Hospitals, Blackburn, United Kingdom
| |
Collapse
|
8
|
Yang X, Zhao Y, Zhong Y, Duan X. The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis. BMC Ophthalmol 2022; 22:305. [PMID: 35836197 PMCID: PMC9284889 DOI: 10.1186/s12886-022-02502-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 06/16/2022] [Indexed: 01/10/2023] Open
Abstract
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. Methods We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. Results We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. Conclusion Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02502-y.
Collapse
Affiliation(s)
- Xiang Yang
- Changsha Aier Eye Hospital, Changsha, Hunan, China
| | - Yang Zhao
- Changsha Aier Eye Hospital, Changsha, Hunan, China
| | - Yu Zhong
- Changsha Aier Eye Hospital, Changsha, Hunan, China.,Aier School of Ophthalmology, Central South University, Changsha, Hunan, China
| | - Xuanchu Duan
- Changsha Aier Eye Hospital, Changsha, Hunan, China. .,Aier School of Ophthalmology, Central South University, Changsha, Hunan, China.
| |
Collapse
|
9
|
Chen XZ, Liang ZQ, Yang KY, Lv K, Ma Y, Li MY, Wu HJ. The Outcomes of XEN Gel Stent Implantation: A Systematic Review and Meta-Analysis. Front Med (Lausanne) 2022; 9:804847. [PMID: 35186992 PMCID: PMC8854748 DOI: 10.3389/fmed.2022.804847] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 01/03/2022] [Indexed: 02/04/2023] Open
Abstract
Purpose XEN gel stents are used for the treatment of open-angle glaucoma (OAG), including primary and secondary glaucoma that are uncontrolled by previous medical therapy and cases with previous failed surgery. Our aim was to systematically review of the clinical data of currently published ab-interno XEN gel stents with an emphasis on intraocular pressure (IOP), antiglaucoma medication outcomes, and safety profiles. Methods We analyzed all of the publications (MEDLINE, EMBASE, Cochrane Library) on the ab-interno XEN gel stent to evaluate the reduction in IOP and antiglaucoma medications following the procedure. The primary outcomes measured for the meta-analysis were reduction in IOP and anti-glaucoma medications. The secondary outcome were adverse events. For each study, we used a random effects analysis model to calculate the mean difference and 95% confidence intervals for the continuous results (reduction in IOP and antiglaucoma medications) using the inverse variance statistical method. Results Five hundred twenty-seven articles were checked and 56 studies were found to be relevant with a total of 4,410 eyes. There was a significant reduction in IOP as well as in the number of medications required in patients treated with ab-interno XEN implant either alone or combined with cataract surgery. This new treatment for various types of glaucoma reduced the IOP by 35% to a final average close to 15 mmHg. This reduction was accompanied by a decrease in the number of antiglaucoma medications in all the studies, approximately 2 classes of medication at the price of more needlings. The overall complete success rate was 21.0–70.8% after 2 years using strict criteria originally designed to record success rate in filtration surgery. The incidence of complications vision-threatening was low at <1%. Conclusions XEN gel stent was effective and safe for primary and secondary OAG. Further studies should be performed to investigate the impact of ethnicity on the success and failure rate after XEN implantation.
Collapse
|
10
|
Kingston EJ, Zagora SL, Symes RJ, Raman P, McCluskey PJ, Lusthaus JA. Infective Necrotizing Scleritis After XEN Gel Stent With Mitomycin-C. J Glaucoma 2022; 31:129-132. [PMID: 34731869 DOI: 10.1097/ijg.0000000000001959] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 10/17/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this study was to report a case of infective necrotizing scleritis following XEN Gel Stent with mitomycin-C. METHODS Case report. This is a case report of a 68-year-old woman. RESULTS XEN Gel Stent glaucoma surgery enhanced with mitomycin-C 0.04% and combined with cataract surgery was performed at a regional center to manage the patient's primary open-angle glaucoma. Past medical history was significant for rheumatoid arthritis requiring treatment with methotrexate and adalimumab. Periocular pain and swelling developed 14 months after the initial operation, followed by a rapid deterioration of visual acuity to 20/60, intraocular pressure of 4 mm Hg, and worsening pain 5 months later. On initial presentation to Sydney Eye Hospital, 180 degrees of scleral necrosis was evident with a moderate anterior segment inflammatory reaction and a large temporal choroidal effusion due to hypotony. Empirical hourly topical ofloxacin and cephalothin 5% drops, with oral moxifloxacin, were initiated. Conjunctival swab grew Staphylococcus aureus and Staphylococcus lugdunensis. Significant clinical improvement occurred, but the XEN Gel Stent became exposed after 9 days of treatment with worsening hypotony. Urgent surgical revision was performed to remove the XEN Gel Stent and apply a tutoplast plug with overlying amniotic membrane graft. Intraocular pressure gradually improved over 6 weeks to 15 mm Hg with reversal of hypotonous changes, and visual acuity stabilized at 20/40. CONCLUSIONS To our knowledge, this is the first reported case of necrotizing scleritis following XEN Gel Stent insertion. It is a reminder that infection should always be the primary differential diagnosis in patients with surgical-induced necrotizing scleritis.
Collapse
Affiliation(s)
| | - Sophia L Zagora
- Department of Ophthalmology, Sydney Eye Hospital
- Save Sight Institute, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| | - Richard J Symes
- Department of Ophthalmology, Sydney Eye Hospital
- Save Sight Institute, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| | - Pushpa Raman
- Department of Ophthalmology, Sydney Eye Hospital
| | - Peter J McCluskey
- Department of Ophthalmology, Sydney Eye Hospital
- Save Sight Institute, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| | - Jed A Lusthaus
- Department of Ophthalmology, Sydney Eye Hospital
- Save Sight Institute, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
11
|
Yang LIMS, Kaijun BETZLERB, Leonard YIPWL, Syril DORAIRAJ, Hou ANGBC. Standalone XEN45 Gel Stent implantation in the treatment of open- angle Glaucoma: A systematic review and meta-analysis. Surv Ophthalmol 2022; 67:1048-1061. [DOI: 10.1016/j.survophthal.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 01/11/2022] [Accepted: 01/19/2022] [Indexed: 10/19/2022]
|
12
|
Pereira ICF, van de Wijdeven R, Wyss HM, Beckers HJM, den Toonder JMJ. Conventional glaucoma implants and the new MIGS devices: a comprehensive review of current options and future directions. Eye (Lond) 2021; 35:3202-3221. [PMID: 34127842 PMCID: PMC8602385 DOI: 10.1038/s41433-021-01595-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 04/19/2021] [Accepted: 05/05/2021] [Indexed: 02/05/2023] Open
Abstract
Glaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Glaucoma drainage devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP. These devices include the traditional aqueous shunts with tube-plate design, as well as more recent implants, such as the trabeculectomy-modifying EX-PRESS® implant and the new minimally invasive glaucoma surgery (MIGS) devices. In this review, we will describe each implant in detail, focusing on their efficacy in reducing IOP and safety profile. Additionally, a critical and evidence-based comparison between these implants will be provided. Finally, we will propose potential developments that may help to improve the performance of current devices.
Collapse
Affiliation(s)
- Inês C. F. Pereira
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rosanne van de Wijdeven
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Hans M. Wyss
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Henny J. M. Beckers
- grid.412966.e0000 0004 0480 1382University Eye Clinic Maastricht, Maastricht University Medical Centre+ (MUMC+), Maastricht, The Netherlands
| | - Jaap M. J. den Toonder
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|