1
|
Hermas A, Tsilfidis C, Karanjia R, Miller G, Kantungane AL, El-Salibi A, Kherani IN, Bali S, Coupland S. Sensitivity and specificity of the uniform field electroretinogram in glaucoma detection in comparison to the pattern electroretinogram. Doc Ophthalmol 2024; 148:97-106. [PMID: 38243039 DOI: 10.1007/s10633-023-09960-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 12/06/2023] [Indexed: 01/21/2024]
Abstract
PURPOSE To determine the ability of the photopic negative response (PhNR) of the uniform field electroretinogram (UF-ERG) to identify early glaucomatous changes in comparison to the checkerboard and bar stimuli of the pattern electroretinogram (PERG). METHODS Forty-nine glaucoma patients were classified into two groups: glaucoma-suspect (23 eyes) and early to moderate glaucoma (30 eyes), based on their clinical examination and the results of standard automated perimetry. Thirty patients (30 eyes) with intraocular pressures (IOP) of 21 mmHg or less, with no history of reported high IOP, were included as controls. PERG and UF-ERG recordings were obtained on a Diagnosys D-341 Attaché-Envoy System. Visual field testing was done only for glaucoma-suspect and glaucoma patients. RESULTS All three tests (PERG bar stimulus, PERG checkerboard stimulus and PhNR) displayed significantly prolonged peak times for glaucoma and glaucoma-suspect patients, with delays ranging from 7.8 to 14.8%, depending on the test. The PERG bar stimulus also showed a significantly lower N95 amplitude for both glaucoma groups (with reductions of 26.0% and 33.0% for glaucoma-suspect and glaucoma groups, respectively). The PERG checkerboard N95 amplitude component had high sensitivity for detecting glaucoma patients but a low specificity (97% and 37%, respectively; AUC = 0.61). Overall, the PhNR peak time showed the highest sensitivity and specificity (77% and 90%, respectively; AUC = 0.87). CONCLUSIONS PERG bar stimuli and the PhNR of the UF-ERG can be used in the clinical setting to detect glaucoma-related changes in glaucoma-suspect and glaucoma patients. However, our data confirm that the PhNR peak time has the best combined sensitivity and specificity.
Collapse
Affiliation(s)
- Asma Hermas
- Regenerative Medicine Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada.
- Department of Cellular and Molecular Medicine, University of Ottawa, Ottawa, ON, Canada.
| | - Catherine Tsilfidis
- Department of Cellular and Molecular Medicine, University of Ottawa, Ottawa, ON, Canada
- Department of Ophthalmology, University of Ottawa, Ottawa, ON, Canada
- Neuroscience Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
| | - Rustum Karanjia
- Regenerative Medicine Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- Department of Ophthalmology, University of Ottawa, Ottawa, ON, Canada
- Neuroscience Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- University of Ottawa Eye Institute, Ottawa, ON, Canada
| | - Garfield Miller
- Regenerative Medicine Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- Department of Ophthalmology, University of Ottawa, Ottawa, ON, Canada
- University of Ottawa Eye Institute, Ottawa, ON, Canada
| | - Ange-Lynca Kantungane
- Regenerative Medicine Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- University of Ottawa Eye Institute, Ottawa, ON, Canada
| | | | - Irfan N Kherani
- Department of Ophthalmology and Visual Sciences, University of Toronto, Toronto, ON, Canada
| | - Shveta Bali
- University of Ottawa Eye Institute, Ottawa, ON, Canada
| | - Stuart Coupland
- Regenerative Medicine Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- Department of Cellular and Molecular Medicine, University of Ottawa, Ottawa, ON, Canada
- Department of Ophthalmology, University of Ottawa, Ottawa, ON, Canada
- Neuroscience Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada
- University of Ottawa Eye Institute, Ottawa, ON, Canada
| |
Collapse
|
2
|
Daka Q, Sustar Habjan M, Meglič A, Perovšek D, Atanasovska Velkovska M, Cvenkel B. Retinal Ganglion Cell Function and Perfusion following Intraocular Pressure Reduction with Preservative-Free Latanoprost in Patients with Glaucoma and Ocular Hypertension. J Clin Med 2024; 13:1226. [PMID: 38592025 PMCID: PMC10931696 DOI: 10.3390/jcm13051226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/13/2024] [Accepted: 02/19/2024] [Indexed: 04/10/2024] Open
Abstract
(1) Background: Given the global prevalence of glaucoma and the crucial role of intraocular pressure (IOP) reduction in the management of the disease, understanding the immediate effects on retinal structure and function is essential. (2) Methods: This study aimed to assess the effects of preservative-free latanoprost on morphological and functional parameters in treatment-naïve patients with ocular hypertension and open-angle glaucoma. (3) Results: This study showed a significant reduction in IOP by an average of 30.6% after treatment with preservative-free latanoprost. Despite the significant reduction in IOP, no statistically significant changes were observed in the electroretinogram (ERG) nor the optical coherence tomography/angiography (OCT/OCTA) parameters compared to baseline. An exploration of the correlation between IOP changes and various parameters revealed a significant association solely with the macular IPL/INL plexus vessel density (VD) measured with OCTA. (4) Conclusions: This finding suggests a possible association between IOP reduction and changes in the macular microcirculation and provides valuable insights into the differential effects of latanoprost. Acknowledging the study limitations, this study emphasizes the need for larger, longer-term investigations to comprehensively assess the sustained effects of preservative-free latanoprost on both IOP and retinal parameters. In addition, exploring systemic factors and conducting subgroup analyses could improve personalized approaches to glaucoma treatment.
Collapse
Affiliation(s)
- Qëndresë Daka
- Department of Pathophysiology, Medical Faculty, University of Prishtina, 10000 Prishtina, Kosovo
- Department of Ophthalmology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (M.S.H.)
| | - Maja Sustar Habjan
- Department of Ophthalmology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (M.S.H.)
| | - Andrej Meglič
- Department of Ophthalmology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (M.S.H.)
| | - Darko Perovšek
- Department of Ophthalmology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (M.S.H.)
| | | | - Barbara Cvenkel
- Department of Ophthalmology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (M.S.H.)
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
| |
Collapse
|
3
|
Hou H, El-Nimri NW, Durbin MK, Arias JD, Moghimi S, Weinreb RN. Agreement and precision of wide and cube scan measurements between swept-source and spectral-domain OCT in normal and glaucoma eyes. Sci Rep 2023; 13:15876. [PMID: 37741895 PMCID: PMC10517954 DOI: 10.1038/s41598-023-43230-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 09/21/2023] [Indexed: 09/25/2023] Open
Abstract
This study aimed to evaluate agreement of Wide scan measurements from swept-source optical coherence tomography (SS-OCT) Triton and spectral-domain OCT (SD-OCT) Maestro in normal/glaucoma eyes, and to assess the precision of measurements from Wide and Cube scans of both devices. Three Triton and three Maestro operator/device configurations were created by pairing three operators, with study eye and testing order randomized. Three scans were captured for Wide (12 mm × 9 mm), Macular Cube (7 mm × 7 mm-Triton; 6 mm × 6 mm-Maestro), and Optic Disc Cube (6 mm × 6 mm) scans for 25 normal eyes and 25 glaucoma eyes. Parameter measurements included circumpapillary retinal nerve fiber layer(cpRNFL), ganglion cell layer + inner plexiform layer (GCL+), and ganglion cell complex (GCL++). A two-way random effect analysis of variance model was used to estimate the repeatability and reproducibility; agreement was evaluated by Bland-Altman analysis and Deming regression. The precision estimates were low, indicating high precision, for all thickness measurements with the majority of the limits < 5 µm for the macula and < 10 µm for the optic disc. Precision of the Wide and Cube scans were comparable. Excellent agreement between the two devices was found for Wide scans, with the mean difference < 3 µm across all measurements (cpRNFL < 3 µm, GCL+ < 2 µm, GCL ++ < 1 µm), indicating interoperability. A single Wide scan covering the peripapillary and macular regions may be useful for glaucoma diagnosis and management.
Collapse
Affiliation(s)
- Huiyuan Hou
- Topcon Healthcare, 111 Bauer Dr, Oakland, NJ, 07436, USA.
| | | | - Mary K Durbin
- Topcon Healthcare, 111 Bauer Dr, Oakland, NJ, 07436, USA
| | - Juan D Arias
- Topcon Healthcare, 111 Bauer Dr, Oakland, NJ, 07436, USA
| | - Sasan Moghimi
- Department of Ophthalmology, Hamilton Glaucoma Center, Shiley Eye Institute, University of California, San Diego, CA, USA
| | - Robert N Weinreb
- Department of Ophthalmology, Hamilton Glaucoma Center, Shiley Eye Institute, University of California, San Diego, CA, USA
| |
Collapse
|
4
|
Hou H, Ei-Nimri NW, Durbin MK, Arias JD, Moghimi S, Weinreb RN. Agreement and Precision of Wide and Cube Scan Measurements between Swept-source and Spectral-domain OCT in Normal and Glaucoma Eyes. RESEARCH SQUARE 2023:rs.3.rs-3002468. [PMID: 37333284 PMCID: PMC10275035 DOI: 10.21203/rs.3.rs-3002468/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/20/2023]
Abstract
This study aimed to evaluate agreement of Wide scan measurements from swept-source optical coherence tomography(SS-OCT) Triton and spectral-domain OCT(SD-OCT) Maestro in normal/glaucoma eyes, and to assess the precision of measurements from Wide and Cube scans of both devices. Three Triton and three Maestro operator/device configurations were created by pairing three operators, with study eye and testing order randomized. Three scans were captured for Wide (12mm×9mm), Macular Cube (7mmx7mm-Triton; 6mmx6mm-Maestro), and Optic Disc Cube (6mmx6mm) scans for 25 normal eyes and 25 glaucoma eyes. Thickness of circumpapillary retinal nerve fiber layer(cpRNFL), ganglion cell layer+inner plexiform layer(GCL+), and ganglion cell complex(GCL++) was obtained from each scan. A two-way random effect analysis of variance model was used to estimate the repeatability and reproducibility; agreement was evaluated by Bland-Altman analysis and Deming regression. Precision limit estimates were low: <5µm for macular and <10µm for optic disc parameters. Precision for Wide and Cube scans of both devices were comparablein both groups. Excellent agreement between the two devices was found for Wide scans, with the mean difference<3µm across all measurements (cpRNFL<3µm, GCL+<2µm, GCL++<1µm), indicating interoperability. A single Wide scan covering the peripapillary and macular regions may be useful for glaucoma management.
Collapse
|