1
|
Jorge J, Fernandes P. Comparison of the PlusoptiX A16 and vision screener V100. FRONTIERS IN OPHTHALMOLOGY 2024; 4:1414417. [PMID: 39391612 PMCID: PMC11464491 DOI: 10.3389/fopht.2024.1414417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 09/05/2024] [Indexed: 10/12/2024]
Abstract
Clinical relevance This study compares a novel photoscreening device with a previously validated one in a school-age population. It highlights a tendency of the new device to underestimate myopic spherical equivalent and overestimate hyperopic cases. Purpose To compare the PlusoptiX A16 and Vision Screener V100 photoscreeners in a study population of school-age children. Methods One hundred and thirty-three children, with a mean age of 6.4 ± 0.5 years, were evaluated using both the PlusoptiX A16 and Vision Screener V100 photoscreeners. The measurements were taken in random order in a room with diminished ambient lighting. Results The mean refractive error values for the M component were 0.27 ± 0.67D (PlusoptiX A16) and 0.21 ± 0.58D (Vision Screener V100). For the J0 component, means were 0.16 ± 0.38D (PlusoptiX A16) and 0.06 ± 0.33D (Vision Screener V100) and for theJ45 component the means were 0.03 ± 0.17D (PlusoptiX A16) and 0.06 ± 0.22D (Vision Screener V100). When compared both instruments, statistically significant differences were observed for the M (p=0.017) and J0 (p=0.004) components. The agreement rates between PlusoptiX A16 and Vision Screener V100 across different refractive components were 80.5% for sphere, 82.0% for cylinder, and 40.6% for axis when considering a range of ±0.75 D for sphere and cylinder and ±25.0 degrees for cylinder axis. Simultaneously considering all three conditions, the overall agreement was 73.7%. Conclusion The Vision Screener V100, while generally aligning well with PlusoptiX A16, tends to underestimate myopic spherical equivalent, overestimate hyperopic cases, and underestimate J0 astigmatism.
Collapse
Affiliation(s)
- Jorge Jorge
- Clinical and Experimental Optometry Research Laboratory (CEORLab), Physics Center of Minho and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal
| | | |
Collapse
|
2
|
Li Y, Li J, Wang H, Du M, Wei L, Su T, Ding G, Qian X, Hua N. The Performance of Spot Photoscreener in 6 to 10 Weeks Infants in China: A Cross-Sectional Study. J Ophthalmol 2024; 2024:8817530. [PMID: 38765182 PMCID: PMC11102112 DOI: 10.1155/2024/8817530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 04/16/2024] [Accepted: 04/24/2024] [Indexed: 05/21/2024] Open
Abstract
Purpose To compare the refractive errors measured by the Spot photoscreener (with or without cycloplegia) to cycloplegic retinoscopy in 6- to 10-week-old infants. Materials and Methods 101 right eyes from 101 healthy infants aged 6 to 10 weeks were recruited for this cross-sectional observational study. Refractive errors were measured using Spot photoscreener before and after cycloplegia, as well as cycloplegic retinoscopy. Comparisons between the refractive measurements were performed using one-way ANOVA with the post hoc Tukey HSD test or Kruskal-Wallis test with the Steel-Dwass test according to the data normality. Pearson's correlation test and 95% confidence intervals were calculated. The agreement was evaluated using a Bland-Altman plot with 95% limits of agreement of the differences. Results Spot photoscreener was found to underestimate the spherical equivalent by 2.33 Diopters (D) in these infants. Following the induction of cycloplegia, the spherical equivalent measured by Spot photoscreener was in excellent agreement with cycloplegic retinoscopy with the mean difference of 0.01 D. Spot photoscreener overestimated cylindrical parameter by 0.2 D with poor agreement with cycloplegic retinoscopy no matter whether cycloplegia was induced. It had good agreement with cycloplegic retinoscopy in the J0 vector than the J45 vector measurement. Conclusions With the induction of cycloplegia, Spot photoscreener can accurately evaluate spherical equivalent in hyperopic infants with mild-to-moderate astigmatism. While it may provide valuable measurements of astigmatism, discrepancies in cylinder and axis should be taken into account.
Collapse
Affiliation(s)
- Yaoling Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Jing Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Huiyu Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Mingyang Du
- Beichen Women's and Children's Health Center, Tianjin 300384, China
| | - Lirong Wei
- Beichen Women's and Children's Health Center, Tianjin 300384, China
| | - Teng Su
- Tianjin Binhai New Area Maternal and Child Health Care and Family Planning Service Center, Tianjin 300459, China
| | - Gang Ding
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Xuehan Qian
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Ning Hua
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| |
Collapse
|
3
|
Li Q, Zhou W, Liao Y, Chen H, Sun Y, Wang M, Wang X, Wang W. Prevalence Trend of Myopia during the Post-COVID-19 Epidemic Period among Preschoolers: A Prospective School-based Study. Optom Vis Sci 2023; 100:727-734. [PMID: 37678562 DOI: 10.1097/opx.0000000000002069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/09/2023] Open
Abstract
SIGNIFICANCE Changes in behavior and lifestyle during the post-coronavirus disease 2019 (COVID-19) epidemic may have some impact on myopia rates in preschoolers, and exploring the changes in myopia rates in preschool children may inform the formulation of myopia prevention and control policies. PURPOSE This study aimed to investigate the prevalence of myopia in preschool children during the post-COVID-19 epidemic period in Xuzhou, China. METHODS A series of cross-sectional school-based studies was conducted. A total of 117,632 preschool children aged 3 to 6 years were subjected to annual vision screening from 2019 to 2021. Spot photo screening was used to record the spherical equivalent refraction for each child and to analyze the prevalence of myopia by age, sex, and region during the post-COVID-19 epidemic period. RESULTS A total of 113,979 preschool children were included in the analysis, of whom 60,784 (53.3%) were male and 53,195 (46.7%) were female. For all children, the mean ± standard deviation spherical equivalent refraction in 2019, 2020, and 2021 was +0.32 ± 0.50, +0.34 ± 0.55, and +0.34 ± 0.54 D, respectively (all P < .05), indicative of a very slight hyperopic shift. In all age groups, the change in mean spherical equivalent refraction and its distribution were relatively stable. From 2019 to 2021, the overall prevalence of myopia in preschool children was 3.1, 3.3, and 3.5%, respectively. The rise in myopia rates was minimal. The largest increase in the annual prevalence of myopia was seen among children aged 6 years, at 0.5%, followed by those aged 5 years (0.4%) and aged 3 years (0.4%). The prevalence was higher in boys than girls and in urban versus rural areas. CONCLUSIONS During the post-COVID-19 epidemic period, the refractive status of Xuzhou preschool children remained stable.
Collapse
Affiliation(s)
- Qin Li
- Department of Ophthalmology, Municipal Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China
| | - Wen Zhou
- Department of Ophthalmology, Municipal Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China
| | - Ya Liao
- Department of Ophthalmology, Municipal Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China
| | - Hongyan Chen
- Department of Ophthalmology, Municipal Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China
| | - Yanmei Sun
- Department of Ophthalmology, Municipal Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China
| | - Mei Wang
- Department of Ophthalmology, Municipal Hospital of Xuzhou Medical University, Xuzhou, Jiangsu Province, China
| | | | | |
Collapse
|
4
|
Wang J, Han Y, Musch DC, Li Y, Wei N, Qi X, Ding G, Li X, Li J, Song L, Zhang Y, Ning Y, Zeng X, Li Y, Sun L, Hua N, Li S, Jardines S, Qian X. Evaluation and Follow-up of Myopia Prevalence Among School-Aged Children Subsequent to the COVID-19 Home Confinement in Feicheng, China. JAMA Ophthalmol 2023; 141:333-340. [PMID: 36821130 PMCID: PMC9951104 DOI: 10.1001/jamaophthalmol.2022.6506] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
Importance Progression of myopia in a school-aged population due to home confinement (January to May 2021) during the COVID-19 pandemic has been previously reported. A key remaining question was whether the myopia spike in children aged 6 to 8 years persisted. Objective To investigate the changes in refractive status and prevalence of myopia in school-aged children 1 year after home confinement ended in China. Design, Setting, and Participants This cross-sectional study with a cohort substudy prospectively evaluated data from school-based photoscreening in Feicheng, China. Children aged 6 to 13 years participated in 8 screenings from 2015 to 2021. Exposures Noncycloplegic photorefraction was conducted using the Spot Vision photoscreener. Main Outcomes and Measures The main outcomes were the differences in spherical equivalent refraction (SER) and prevalence of myopia between 2020 (during home confinement) and 2021 (after home confinement). The SER was recorded for each child, and the prevalence of myopia was calculated annually for each age group. Results A total of 325 443 children participated in the study (51.4% boys, 48.6% girls; age range, 6 to 13 years). Compared with 2020, the mean SER of children in 2021 increased significantly for those aged 6 (0.42 diopters [D]), 7 (0.41 D), and 8 (0.33 D) years. The prevalence of myopia in 2021 was similar to in 2019 for each age group (aged 6 years: 7.9% vs 5.7%; aged 7 years: 13.9% vs 13.6%; aged 8 years: 29.5% vs 26.2%). Both the prevalence of myopia and mean SER for these children returned to their prepandemic levels. Conclusions and Relevance Compared with 2020, the prevalence of myopia among children aged 6 to 8 years in the 2021 screenings decreased, and the mean SER returned to prepandemic level. The refractive development in children aged 6 to 8 years may be most susceptible to environmental changes. These findings support the premise that age 6 to 8 years is a critical period for myopia development and suggest a need to focus preventive interventions for myopia control on children in this age range.
Collapse
Affiliation(s)
- Jiaxing Wang
- Department of Ophthalmology, Emory University, Atlanta, Georgia
| | - Yujie Han
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of the National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - David C. Musch
- Departments of Ophthalmology and Visual Sciences and Epidemiology, University of Michigan, Ann Arbor, Michigan
| | - Ying Li
- Department of Ophthalmology, Emory University, Atlanta, Georgia
| | - Nan Wei
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaoli Qi
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Gang Ding
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xue Li
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Jing Li
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Linlin Song
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ying Zhang
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yuxian Ning
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaoyu Zeng
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yaoling Li
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ling Sun
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of the National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ning Hua
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Shuo Li
- Department of Respiratory and Critical Medicine, Tianjin Medical University General Hospital, Tianjin, China
| | - Sandra Jardines
- Department of Ophthalmology, Emory University, Atlanta, Georgia
| | - Xuehan Qian
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| |
Collapse
|
5
|
Du W, Ding G, Guo X, Abudukeyimu K, Wang Y, Wang L, Qi X, Ning Y, Hua N, Song L, Li X, Li J, Zhang Y, Wei N, Qian X. Associations between anthropometric indicators and refraction in school-age children during the post-COVID-19 era. Front Public Health 2023; 10:1059465. [PMID: 36743176 PMCID: PMC9891462 DOI: 10.3389/fpubh.2022.1059465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 12/20/2022] [Indexed: 01/19/2023] Open
Abstract
Purpose To explore the associations between anthropometric indicators and refraction in school-aged children in the post-COVID-19 era. Methods Data were collected from 25,644 children aged 7 to 12 years in 48 elementary schools in Tianjin. The comprehensive examination included height, weight, systolic blood pressure (SBP), diastolic blood pressure (DBP), refraction, and calculation of BMI, with a follow-up visit after 6 months. Myopia was defined as spherical equivalent refraction (SER) ≤-0.50 diopter (D). Bivariate correlation coefficients and multiple linear regression models were used to explore the cross-sectional and longitudinal associations between anthropometric indicators (height, weight, BMI, SBP, and DBP) and refraction. Results The mean changes in height, weight, BMI, SBP, DBP, and SER of the participants were 4.03 ± 2.18 cm, 3.10 ± 2.39 kg, 0.45 ± 1.16 kg/m2, 2.26 ± 14.74 mmHg, 2.18 ± 11.79 mmHg and -0.17 ± 0.51 D, respectively. Overall, height, weight, BMI, SBP, and DBP were all correlated with SER (r = -0.324, r = -0.234, r = -0.121, r = -0.112, r = -0.066, both p < 0.001), and changes in height and weight were correlated with changes in SER (r = -0.034, -0.031, both p < 0.001). Furthermore, multiple linear regression analysis revealed that the association of BMI, SBP, and DBP with SER was significant in myopic children but not in non-myopic children. The association between changes in weight and changes in SER was only present in non-myopic children but not in myopic children. Conclusion Height and weight were negatively correlated with SER in both cross-sectional analysis and longitudinal changes, indicating that children's height, weight and growth rate may be used as a reference indicator for myopia risk prediction and myopia progression monitoring.
Collapse
Affiliation(s)
- Wenzheng Du
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Gang Ding
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiying Guo
- Tianjin Beichen Traditional Chinese Medicine Hospital, Tianjin, China
| | - Kadiya Abudukeyimu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yanzhu Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Lijun Wang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaoli Qi
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yuxian Ning
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ning Hua
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Linlin Song
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xue Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Jing Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ying Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Nan Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xuehan Qian
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China,*Correspondence: Xuehan Qian ✉
| |
Collapse
|
6
|
Abstract
CLINICAL RELEVANCE For a correct spectacle prescription, accommodation spasm should not be overlooked in the measurements made using an autorefractometer. Although this can be easily understood with cycloplegia, it is not practical. Therefore, investigating practical methods that can predict excess accommodation will be useful in clinical practice. BACKGROUND To evaluate the performance of a photoscreener in detecting pseudo-myopia due to accommodation spasm and whether it eliminates the need for cycloplegia. METHODS Study was conducted in Van Training and Research Hospital. The manifest refraction of the patients was measured using an by an autorefractometer followed by a photoscreener before cycloplegia. Cycloplegic refraction errors were detected using an autorefractometer. Patients with pseudo-myopia due to accommodation spasm were diagnosed by observing a significant hyperopic shift in cycloplegic autorefractometer values compared to the non-cycloplegic values and were included in study. Cycloplegic autorefractometer and non-cycloplegic photoscreener measurements were compared. RESULTS The mean non-cycloplegic autorefractometer values were as follows: --6.34 ± 1.29D, -0.42 ± 0.58D, and -6.55 ± 1.36D for spherical, cylindrical, and spherical equivalents, respectively. These values were 0.23 ± 0.63D, -0.21 ± 0.41D, and 0.11 ± 0.73D for cycloplegic autorefractometer measurements, respectively. Cycloplegic autorefractometer values showed a significant hyperopic shift of 6.57 ± 1.26D and 6.67 ± 1.34D for spherical and spherical equivalents, respectively, compared to non-cycloplegic values (p < 0.001 for both). There was no significant difference between non-cycloplegic photoscreener and cycloplegic autorefractometer measurements for spherical, cylindrical, and spherical equivalents (p = 0.126, p = 0.078, and p = 0.053, respectively). . There was agreement between the measurements in the Bland-Altman graph. CONCLUSION There was consistency between non-cycloplegic photoscreener and cycloplegic autorefractometer measurements in patients with pseudomyopia due to accommodation spasm. Therefore, photoscreener measurements can be a fast, practical, cost-effective examination method for screening these patients without the need for cycloplegia.
Collapse
Affiliation(s)
- Mehmet Siraç Demir
- Van Training and Research Hospital, Ophthalmology Department, Saglik Bilimleri University, Van, Turkey
| | - Ersin Muhafiz
- Faculty of Medicine, Ophthalmology Department, Kafkas University, Kars, Turkey
| |
Collapse
|
7
|
Wang J, Li Y, Musch DC, Wei N, Qi X, Ding G, Li X, Li J, Song L, Zhang Y, Ning Y, Zeng X, Hua N, Li S, Qian X. Progression of Myopia in School-Aged Children After COVID-19 Home Confinement. JAMA Ophthalmol 2021; 139:293-300. [PMID: 33443542 PMCID: PMC7809617 DOI: 10.1001/jamaophthalmol.2020.6239] [Citation(s) in RCA: 232] [Impact Index Per Article: 77.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Question Is home confinement due to coronavirus disease 2019 associated with the burden of myopia? Findings In this cross-sectional study that included 194 904 photoscreening tests conducted in 123 535 children, a substantial myopic shift (−0.3 diopters) was noted after home confinement due to coronavirus disease 2019 for children aged 6 to 8 years. The prevalence of myopia increased 1.4 to 3 times in 2020 compared with the previous 5 years. Meaning Home confinement due to coronavirus disease 2019 appeared to be associated with a substantial myopic shift in children; younger (aged 6-8 years) children’s refractive status may be more sensitive to environmental changes than older children, given that they are in an important period for the development of myopia. Importance Time spent in outdoor activities has decreased owing to home confinement for the coronavirus disease 2019 (COVID-19) pandemic. Concerns have been raised about whether home confinement may have worsened the burden of myopia owing to substantially decreased time spent outdoors and increased screen time at home. Objective To investigate the refractive changes and prevalence of myopia in school-aged children during the COVID-19 home confinement. Design, Setting, and Participants A prospective cross-sectional study using school-based photoscreenings in 123 535 children aged 6 to 13 years from 10 elementary schools in Feicheng, China, was conducted. The study was performed during 6 consecutive years (2015-2020). Data were analyzed in July 2020. Exposures Noncycloplegic photorefraction was examined using a photoscreener device. Main Outcomes and Measures The spherical equivalent refraction was recorded for each child and the prevalence of myopia for each age group during each year was calculated. The mean spherical equivalent refraction and prevalence of myopia were compared between 2020 (after home confinement) and the previous 5 years for each age group. Results Of the 123 535 children included in the study, 64 335 (52.1%) were boys. A total of 194 904 test results (389 808 eyes) were included in the analysis. A substantial myopic shift (approximately −0.3 diopters [D]) was found in the 2020 school-based photoscreenings compared with previous years (2015-2019) for younger children aged 6 (−0.32 D), 7 (−0.28 D), and 8 (−0.29 D) years. The prevalence of myopia in the 2020 photoscreenings was higher than the highest prevalence of myopia within 2015-2019 for children aged 6 (21.5% vs 5.7%), 7 (26.2% vs 16.2%), and 8 (37.2% vs 27.7%) years. The differences in spherical equivalent refraction and the prevalence of myopia between 2020 and previous years were minimal in children aged 9 to 13 years. Conclusions and Relevance Home confinement during the COVID-19 pandemic appeared to be associated with a significant myopic shift for children aged 6 to 8 years according to 2020 school-based photoscreenings. However, numerous limitations warrant caution in the interpretation of these associations, including use of noncycloplegic refractions and lack of orthokeratology history or ocular biometry data. Younger children’s refractive status may be more sensitive to environmental changes than older ages, given the younger children are in a critical period for the development of myopia.
Collapse
Affiliation(s)
- Jiaxing Wang
- Department of Ophthalmology, Emory University, Atlanta, Georgia
| | - Ying Li
- Department of Ophthalmology, Emory University, Atlanta, Georgia
| | - David C Musch
- Department of Ophthalmology and Visual Sciences, Department of Epidemiology, University of Michigan, Ann Arbor
| | - Nan Wei
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaoli Qi
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Gang Ding
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xue Li
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Jing Li
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Linlin Song
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ying Zhang
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yuxian Ning
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaoyu Zeng
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Ning Hua
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Shuo Li
- Department of Respiratory and Critical Medicine, Tianjin Medical University General Hospital, Tianjin, China
| | - Xuehan Qian
- Department of Strabismus and Pediatric Ophthalmology, Tianjin Medical University Eye Hospital, Tianjin, China
| |
Collapse
|