Abstract
BACKGROUND
Long PR intervals may increase cardiovascular complications, including atrial fibrillation. In pacemakers, the SafeR™ mode monitors PR intervals, switching from AAI to DDD when criteria for atrioventricular block are met.
AIMS
The PRECISE study evaluated the incidence and predictors of long PR intervals and their association with incident atrial fibrillation after 1 year in patients implanted for sinus node dysfunction and free from significant conduction disorders at baseline.
METHODS
This French, prospective, multicentre, observational trial enrolled patients implanted with a REPLY™ dual-chamber pacemaker. Pacemaker memory recorded long PR intervals (defined as first-degree atrioventricular block mode switches occurring after six consecutive PR/AR intervals≥350/450ms) and atrial fibrillation incidence (fallback mode switch>1minute/day). Predictors were identified from baseline variables (age, sex, AR and PR intervals, atrial rhythm disorder and medication) using logistic regression.
RESULTS
Of 291 patients with sinus node dysfunction enrolled, 214 were free from significant conduction disorders at baseline (mean age 79±8 years; 44% men; PR/AR intervals<350/450ms). After 1 year, long PR intervals had occurred in 116 patients (54%) and atrial fibrillation in 63 patients (30%). Amiodarone was the only independent predictor of long PR interval occurrence (odds ratio 2.50, 95% confidence interval 1.20-5.21; P=0.014). There was a strong trend towards an association between long PR interval and atrial fibrillation incidence (odds ratio 1.86, 95% confidence interval 0.97-3.61; P=0.051).
CONCLUSIONS
Half of the patients with pure sinus node dysfunction developed long PR intervals in the year following pacemaker implantation. Amiodarone was the only independent predictor of long PR intervals. There was a strong trend towards an association between long PR intervals and incident atrial fibrillation.