Liang JJ, Shirai Y, Briceño DF, Muser D, Enriquez A, Lin A, Hyman MC, Kumareswaran R, Arkles JS, Santangeli P, Schaller RD, Supple GE, Frankel DS, Deo R, Epstein AE, Garcia FC, Riley MP, Nazarian S, Lin D, Callans DJ, Marchlinski FE, Dixit S. Electrocardiographic and Electrophysiologic Characteristics of Idiopathic Ventricular Arrhythmias Originating From the Basal Inferoseptal Left Ventricle. JACC Clin Electrophysiol 2019; 5:833-842. [PMID: 31320012 DOI: 10.1016/j.jacep.2019.04.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 04/04/2019] [Accepted: 04/22/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVES This study sought to characterize ventricular arrhythmia (VA) ablated from the basal inferoseptal left ventricular endocardium (BIS-LVe) and identify electrocardiographic characteristics to differentiate from inferobasal crux (IBC) VA. BACKGROUND The inferior basal septum is an uncommon source of idiopathic VAs, which can arise from its endocardial or epicardial (crux) aspect. Because the latter are often targeted from the coronary venous system or epicardium, distinguishing between the 2 is important for successful ablation. METHODS Consecutive patients undergoing ablation of idiopathic VA from the BIS-LVe or IBC from 2009 to 2018 were identified and clinical characteristics and electrocardiographs of VA were compared. RESULTS Of 931 patients undergoing idiopathic VA ablation, Virginia was eliminated from the BIS-LVe in 19 patients (2%) (17 male, age 63.7 ± 9.2 years, LV ejection fraction: 45.0 ± 9.3%). QRS complexes typically manifested right bundle branch block morphology with "reverse V2 pattern break" and left superior axis (more negative in lead III than II). VA elimination was achieved after median of 2 lesions (interquartile range [IQR]: 1-6; range 1 to 20) (radiofrequency ablation time: 123 s [IQR: 75-311]). Compared with 7 patients with IBC VA (3 male, age 51.9 ± 20.1 years, LV ejection fraction: 51.4 ± 17.7%), BIS-LVe VA less frequently had initial negative forces (QS pattern) in leads II, III, and/or aVF (p < 0.001), R-S ratio <1 in lead V1 (p = 0.005), and notching in lead II (p = 0.006) were narrower (QRS duration: 178.2 ± 22.4 vs. 221.1 ± 41.9 ms; p = 0.04) and more frequently had maximum deflection index of <0.55 (p < 0.001). CONCLUSIONS The BIS-LVe region is an uncommon source of idiopathic VA. Distinguishing these from IBC VA is important for procedural planning and ablation success.
Collapse
Affiliation(s)
- Jackson J Liang
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Yasuhiro Shirai
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - David F Briceño
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Daniele Muser
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Andres Enriquez
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Aung Lin
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Matthew C Hyman
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Ramanan Kumareswaran
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Jeffrey S Arkles
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Pasquale Santangeli
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Robert D Schaller
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Gregory E Supple
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - David S Frankel
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Rajat Deo
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Andrew E Epstein
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Fermin C Garcia
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Michael P Riley
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Saman Nazarian
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - David Lin
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - David J Callans
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Francis E Marchlinski
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Sanjay Dixit
- Division of Cardiology, Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania.
| |
Collapse
|