Wilson-Stewart KS, Fontanarosa D, Malacova E, Trapp JV. A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures. Sci Rep 2023; 13:2391. [PMID: 36765105 PMCID: PMC9918729 DOI: 10.1038/s41598-023-28704-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 01/23/2023] [Indexed: 02/12/2023] Open
Abstract
The number and complexity of transcatheter procedures continue to increase, raising concerns regarding radiation exposure to patients and staff. Procedures such as transaortic valve implantations (TAVI) have led to cardiologists adopting higher dose techniques, such as digital subtraction angiography (DSA). This study compared the estimated patient and occupational eye dose during coronary angiography (CA), percutaneous coronary intervention (PCI), TAVI workups (TWU), TAVI, endovascular aneurysm repairs (EVAR), and other peripheral diagnostic (VD) and interventional (VI) vascular procedures. A quantitative analysis was performed on patient dose during 299 endovascular and 1498 cardiac procedures. Occupational dose was measured for the cardiologists (n = 24), vascular surgeons (n = 3), scrub (n = 32) and circulator nurses (n = 35). TAVI and EVAR were associated with the highest average dose for all staff, and significantly higher patient dose area product, probably attributable to the use of DSA. Scrub nurses were exposed to higher average doses than the operator and scout nurse during CA, VD and VI. Circulating nurses had the highest average levels of exposure during TAVI. This study has demonstrated that EVAR and TAVI have similar levels of occupational and patient dose, with a notable increase in circulator dose during TAVI. The use of DSA during cardiac procedures is associated with an increase in patient and staff dose, and cardiologists should evaluate whether DSA is necessary. Scrub nurses may be exposed to higher levels of occupational dose than the operator.
Collapse
Affiliation(s)
- Kelly S Wilson-Stewart
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia. .,Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove, Brisbane, QLD, 4059, Australia. .,Cardiovascular Suites, Greenslopes Private Hospital, Greenslopes, Brisbane, QLD, 4120, Australia.
| | - Davide Fontanarosa
- Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove, Brisbane, QLD, 4059, Australia.,School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia
| | - Eva Malacova
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,QIMR Berghofer Medical Research Institute, 300 Herston Road, Herston, Brisbane, QLD, 2006, Australia
| | - Jamie V Trapp
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove, Brisbane, QLD, 4059, Australia
| |
Collapse
|
2
|
Chmil V, Filipová A, Tichý A. Looking for the phoenix: the current research on radiation countermeasures. Int J Radiat Biol 2023; 99:1148-1166. [PMID: 36745819 DOI: 10.1080/09553002.2023.2173822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 09/06/2022] [Accepted: 12/26/2022] [Indexed: 02/08/2023]
Abstract
PURPOSE Ionizing radiation (IR) is widely applied in radiotherapy for the treatment of over 50% of cancer patients. IR is also intensively used in medical diagnostics on a daily basis in imaging. Moreover, recent geopolitical events have re-ignited the real threat of the use of nuclear weapons. Medical radiation countermeasures represent one of the effective protection strategies against the effects of IR. The aim of this review was to summarize the most commonly used strategies and procedures in the development of radiation countermeasures and to evaluate the current state of their research, with a focus on those in the clinical trial phase. METHODS Clinical trials for this review were selected in accordance with the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement. The search was performed in the clinicaltrials.gov database as of May 2022. RESULTS Our search returned 263 studies, which were screened and of which 25 were included in the review. 10 of these studies had been completed, 3 with promising results: KMRC011 increased G-CSF, IL-6, and neutrophil counts suggesting potential for the treatment of hematopoietic acute radiation syndrome (H-ARS); GC4419 reduced the number of patients with severe oral mucositis and its duration; the combination of enoxaparin, pentoxifylline, and ursodeoxycholic acid reduced the incidence of focal radiation-induced liver injury. CONCLUSION The agents discovered so far show significant side effects or low efficacy, and hence most of the tested agents terminate in the early stages of development. In addition, the low profitability of this type of drug demotivates the private sector to invest in such research. To overcome this problem, there is a need to involve more public resources in funding. Among the technological opportunities, a deeper use of in silico approaches seems to be prospective.
Collapse
Affiliation(s)
- Vojtěch Chmil
- Department of Radiobiology, Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic
| | - Alžběta Filipová
- Department of Radiobiology, Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic
| | - Aleš Tichý
- Department of Radiobiology, Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic
- Biomedical Research Centre, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic
| |
Collapse
|
3
|
Wilson-Stewart KS, Fontanarosa D, Malacova E, Trapp JV. Comparison of patient and staff temple dose during fluoroscopically guided coronary angiography, implantable cardiac devices, and electrophysiology procedures. Phys Med 2021; 90:142-149. [PMID: 34649045 DOI: 10.1016/j.ejmp.2021.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 09/03/2021] [Accepted: 09/17/2021] [Indexed: 11/28/2022] Open
Abstract
There is a paucity of literature comparing patient and staff dose during coronary angiography (CA), implantable cardiac devices, permanent pacemakers (PPM) and electrophysiology (EP) procedures and little noting dose to staff other than cardiologists. This study sought to compare patient and occupational dose during a range of fluoroscopically guided cardiac procedures. Radiation dose levels for the patients (n = 1651), cardiologists (n = 24), scrub (n = 32) and scout nurses (n = 35) were measured in a prospective single-centre study between February 2017 and August 2019. A comparison of dose during CA, device implantation, PPM insertion and EP studies was performed. Three angiographic units were used, with dosimeters worn on the temple of staff. Results indicated that occupational dose during PPM was significantly higher than other procedures. The cardiologist had the highest mean dose during biventricular implantable cardioverter-defibrillators; levels were approximately five times that of 'normal' pacemaker insertions. Transcatheter aortic valve implantations (TAVI) were associated with relatively high mean doses for both staff and patients and had a statistically significant higher (>2 times) mean patient dose area product than all other categories. TAVI workups were also related to higher mean cardiologist and scrub nurse dose. It was observed that the mean scrub nurse dose can exceed that of the cardiologist. The highest mean dose for Scout nurses were recorded during EP studies. Given the significantly higher temple dose associated with PPM insertion, cardiologists should consider utilizing ceiling mounted lead shields, lead glasses and/or skull caps where possible. Efforts should also be made to minimize the use of DSA during TAVI and TAVI workups to reduce cardiologist, nurse and patient dose.
Collapse
Affiliation(s)
- Kelly S Wilson-Stewart
- School of Chemistry and Physics, Faulty of Science, Queensland Univeristy of Technology, 2 George Street, Brisbane, QLD 4000, Australia; Greenslopes Private Hospital, Ramsay Health Care, Newdegate Street, Greenslopes, Brisbane, QLD 4120, Australia.
| | - Davide Fontanarosa
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia; Centre for Biomedical Technologies (CBT), Queensland University of Technology, Brisbane, QLD 4000, Australia
| | - Eva Malacova
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia; QMIR Berghofer Medical Research Institute, 200 Herston Road, Herston, QLD 4006, Australia
| | - Jamie V Trapp
- School of Chemistry and Physics, Faulty of Science, Queensland Univeristy of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| |
Collapse
|