1
|
Gładysz-Wańha S, Joniec M, Wańha W, Piłat E, Drzewiecka A, Gardas R, Biernat J, Węglarzy A, Gołba KS. Transvenous lead extraction safety and efficacy in infected and noninfected patients using mechanical-only tools: Prospective registry from a high-volume center. Heart Rhythm 2024; 21:427-435. [PMID: 38157921 DOI: 10.1016/j.hrthm.2023.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 12/01/2023] [Accepted: 12/21/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND Transvenous lead extraction (TLE) is a well-established treatment option for patients with cardiac implantable electronic devices (CIED) complications. OBJECTIVE The purpose of this study was to evaluate the safety and efficacy of TLE in CIED infection and non-CIED infection patients. METHODS Consecutive patients who underwent TLE between 2016 and 2022 entered the EXTRACT Registry. Models of prediction were constructed for periprocedural clinical and procedural success and the incidence of major complications, including death in 30 days. RESULTS The registry enrolled 504 patients (mean age 66.6 ± 12.8 years; 65.7% male). Complete procedural success was achieved in 474 patients (94.0%) and clinical success in 492 patients (97.6%). The total number of major and minor complications was 16 (3.2%) and 51 (10%), respectively. Three patients (0.6%) died during the procedure. New York Heart Association functional class IV and C-reactive protein levels defined before the procedure were independent predictors of any major complication, including death in 30 days in CIED infection patients. The time since the last preceding procedure and platelet count before the procedure were independent predictors of any major complication, including death in 30 days in non-CIED infection patients. CONCLUSIONS TLE is safe and successfully performed in most patients, with a low major complication rate. CIED infection patients demonstrate better periprocedural clinical success and complete procedural success. However, CIED infection predicts higher 30-day mortality compared with non-CIED infection patients. Predictors of any major complication, including death in 30 days, differ between CIED infection and non-CIED infection patients.
Collapse
Affiliation(s)
- Sylwia Gładysz-Wańha
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland; Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland; Doctoral School of the Medical University of Silesia in Katowice, Poland.
| | - Michał Joniec
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland; Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland; Doctoral School of the Medical University of Silesia in Katowice, Poland
| | - Wojciech Wańha
- Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
| | - Eugeniusz Piłat
- Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland
| | - Anna Drzewiecka
- Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland
| | - Rafał Gardas
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland; Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland
| | - Jolanta Biernat
- Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland
| | - Andrzej Węglarzy
- Department of Anaesthesiology and Intensive Care with Cardiac Supervision, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland
| | - Krzysztof S Gołba
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland; Department of Electrocardiology, Upper Silesian Medical Center of the Medical University of Silesia, Katowice, Poland
| |
Collapse
|
2
|
Rinaldi CA, Diemberger I, Biffi M, Gao YR, Sizto E, Jin N, Epstein LM, Defaye P. Safety and success of transvenous lead extraction using excimer laser sheaths: a meta-analysis of over 1700 patients. Europace 2023; 25:euad298. [PMID: 37757839 PMCID: PMC10655058 DOI: 10.1093/europace/euad298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 09/24/2023] [Indexed: 09/29/2023] Open
Abstract
AIMS While numerous studies have demonstrated favourable safety and efficacy of the excimer laser sheath for transvenous lead extraction (TLE) in smaller cohorts, comprehensive large-scale investigations with contemporary data remain scarce. This study aims to evaluate the safety and performance of laser-assisted TLE through a meta-analysis of contemporary data. METHODS AND RESULTS A systematic literature search was conducted to identify articles that assessed the safety and performance of the spectranetics laser sheath (SLS) II and GlideLight Excimer laser sheaths in TLE procedures between 1 April 2016 and 31 March 2021. Safety outcomes included procedure-related death and major/minor complications. Performance outcomes included procedural and clinical success rates. A random-effects, inverse-variance-weighting meta-analysis was performed to obtain the weighted average of the evaluated outcomes. In total, 17 articles were identified and evaluated, including 1729 patients with 2887 leads. Each patient, on average, had 2.3 ± 0.3 leads with a dwell time of 7.9 ± 3.0 years. The TLE procedural successes rate was 96.8% [1440/1505; 95% CI: (94.9-98.2%)] per patient and 96.3% [1447/1501; 95% CI: (94.8-97.4%)] per lead, and the clinical success rate per patient was 98.3% [989/1010, 95% CI: (97.4-99.0%)]. The procedure-related death rate was 0.08% [7/1729, 95% CI: (0.00%, 0.34%)], with major and minor complication rates of 1.9% [41/1729; 95% CI: (1.2-2.8%)] and 1.9% [58/1729; 95% CI: (0.8-3.6%)], respectively. CONCLUSION This meta-analysis demonstrated that excimer laser sheath-assisted TLE has high success and low procedural mortality rates. It provides clinicians with a reliable and valuable resource for extracting indwelling cardiac leads which require advanced extraction techniques.
Collapse
Affiliation(s)
- Christopher Aldo Rinaldi
- Cardiovascular Department, Guy's & St Thomas' NHS Foundation Trust, Lambeth Palace Road, London SE1 7EH, UK
- Heart Vascular and Thoracic Institute, Cleveland Clinic London, 33 Grosvenor Pl, London SW1X 7HY, UK
| | - Igor Diemberger
- Department of Medical and Surgical Sciences, University of Bologna, Policlinico S.Orsola-Malpighi, via Massarenti 9, 40138 Bologna, Italy
- Cardiology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico S Orsola-Malpighi, via Massarenti 9, 40138 Bologna, Italy
| | - Mauro Biffi
- Cardiology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico S Orsola-Malpighi, via Massarenti 9, 40138 Bologna, Italy
| | - Yu-Rong Gao
- Image Guided Therapy, Philips North America LLC, Cambridge, MA, USA
| | - Enoch Sizto
- Image Guided Therapy, Philips North America LLC, Cambridge, MA, USA
| | - Nancy Jin
- Image Guided Therapy, Philips North America LLC, Cambridge, MA, USA
| | | | - Pascal Defaye
- Department of Cardiology, University Hospital of Grenoble Alpes, Grenoble, France
| |
Collapse
|
3
|
Akhtar Z, Kontogiannis C, Georgiopoulos G, Starck CT, Leung LWM, Lee SY, Lee BK, Seshasai SRK, Sohal M, Gallagher MM. Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis. Europace 2023; 25:euad316. [PMID: 37882609 PMCID: PMC10638006 DOI: 10.1093/europace/euad316] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 08/07/2023] [Accepted: 09/24/2023] [Indexed: 10/27/2023] Open
Abstract
AIMS Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.
Collapse
Affiliation(s)
- Zaki Akhtar
- Department of Cardiology, St George’s University Hospital, London, UK
| | | | - Georgios Georgiopoulos
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Clinical Therapeutics, National and Kapodistrian University of Athens, Athens, Greece
| | - Christoph T Starck
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| | - Lisa W M Leung
- Department of Cardiology, St George’s University Hospital, London, UK
| | - Sun Y Lee
- Department of Medicine, San Joaquin General Hospital, French Camp, CA, USA
| | - Byron K Lee
- Division of Cardiology, University of California, San Francisco, CA, USA
| | | | - Manav Sohal
- Department of Cardiology, St George’s University Hospital, London, UK
| | - Mark M Gallagher
- Department of Cardiology, St George’s University Hospital, London, UK
| |
Collapse
|
4
|
Heck R, Peters B, Lanmüller P, Photiadis J, Berger F, Falk V, Starck C, Kramer P. Transvenous lead extraction in children with bidirectional rotational dissection sheaths. Front Cardiovasc Med 2023; 10:1256752. [PMID: 37745106 PMCID: PMC10515391 DOI: 10.3389/fcvm.2023.1256752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 08/21/2023] [Indexed: 09/26/2023] Open
Abstract
Objectives Due to the limited longevity of endovascular leads, children require thoughtful lifetime lead management strategies including conservation of access vessel patency. Consequently, there is an increasing interest in transvenous lead extraction (TLE) in children, however, data on TLE and the use of powered mechanical dissection sheaths is limited. Methods We performed a retrospective cohort study analyzing all children <18 years that underwent TLE in our institution from 2015 to 2022. Procedural complexity, results and complications were defined as recommended by recent consensus statements. Results Twenty-eight children [median age 12.8 (interquartile range 11.3-14.6) years] were included. Forty-one leads were extracted [median dwell time 85 (interquartile range 52-102) months]. Extractions of 31 leads (76%) in 22 patients (79%) were complex, requiring advanced extraction tools including powered bidirectional rotational dissection sheaths in 14 children. There were no major complications. Complete procedural success was achieved in 18 (64%) and clinical success in 27 patients (96%), respectively. Procedural success and complexity varied between lead types. The Medtronic SelectSecure™ lead was associated with increased odds of extraction by simple traction (p = 0.006) and complete procedural success (p < 0.001) while the Boston Scientific Fineline™ II lead family had increased odds of partial procedural failure (p = 0.017). Conclusions TLE with the use of mechanical powered rotational dissection sheaths is feasible and safe in pediatric patients. In light of rare complications and excellent overall clinical success, TLE should be considered an important cornerstone in lifetime lead management in children. Particular lead types might be more challenging and less successful to extract.
Collapse
Affiliation(s)
- Roland Heck
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Björn Peters
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
| | - Pia Lanmüller
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Joachim Photiadis
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Department of Congenital and Pediatric Heart Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
| | - Felix Berger
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Partner Site Berlin, DZHK (German Center for Cardiovascular Research), Berlin, Germany
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Partner Site Berlin, DZHK (German Center for Cardiovascular Research), Berlin, Germany
- Translational Cardiovascular Technologies, Institute of Translational Medicine, Department of Health Sciences and Technology, Swiss Federal Institute of Technology (ETH) Zurich, Switzerland
| | - Christoph Starck
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Steinbeis Hochschule, Steinbeis-Transfer-Institut Kardiotechnik, Berlin, Germany
| | - Peter Kramer
- Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
| |
Collapse
|
5
|
Miguelena Hycka J, López Menéndez J, Martín García M, Muñoz Pérez R, Castro Pinto M, Torres Terreros CB, García Chumbiray PF, Rodriguez-Roda J. Electrodos no funcionantes ¿Extracción o abandono? CIRUGIA CARDIOVASCULAR 2023. [DOI: 10.1016/j.circv.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
6
|
Nowosielecka D, Tułecki Ł, Jacheć W, Polewczyk A, Tomków K, Stefańczyk P, Bródka J, Kutarski A. Cardiac tamponade as an inherent but potentially nonfatal complication of transvenous lead extraction: Experience with 1126 procedures performed using mechanical tools. J Cardiovasc Electrophysiol 2022; 33:2625-2639. [PMID: 36054327 DOI: 10.1111/jce.15668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 07/20/2022] [Accepted: 08/29/2022] [Indexed: 12/15/2022]
Abstract
INTRODUCTION Cardiac tamponade (CT) is one of the most common and dangerous complications of transvenous lead extraction (TLE). So far, however, there has been little discussion about the problem. METHODS We analyzed the occurrence of CT in a group of 1226 patients undergoing TLE at a single reference center between June, 2015 and February, 2021. Using standard mechanical devices as first-line tools, a total of 2092 leads had been extracted. RESULTS CT occurred in 18 patients (1.47%): due to injury to the wall of the right atrium in 14 patients (1.14%) and other cardiac walls in four patients (0.33%). Younger patient age at first implantation, female gender, high left ventricular ejection fraction (LVEF), lower New York Heart Association class, low Charlson comorbidity index, longer implant duration, and the number of previous procedures related to cardiac implantable electronic devices (CIED) are important patient-related risk factors for CT. Significant procedure-related risk factors include the number of extracted leads, extraction of atrial leads and longer dwell time of extracted leads. Intraoperative transoesophageal echocardiography (TEE) provides a lot of information about pulling on various cardiac structures and is able to detect a very early phase of bleeding to the pericardial sac. As a result of implementing best practices guidance in performing extraction procedures and close collaboration with cardiac surgeons that allowed immediate rescue intervention in our series of 18 CT cases, there were no procedure-related deaths (mortality 0%). CONCLUSIONS The need for rescue surgery due to CT has no influence on clinical and procedural success. Early diagnosed (TEE monitoring) and properly managed CT does not generate any additional risk in short- and long-term follow-up after TLE.
Collapse
Affiliation(s)
- Dorota Nowosielecka
- Department of Cardiology, The Pope John Paul II Province Hospital, Zamość, Poland.,Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland
| | - Łukasz Tułecki
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland
| | - Wojciech Jacheć
- Department of Cardiology, Zabrze, Faculty of Medical Science in Zabrze, Medical University of Silesia in Katowice, Poland, Poland
| | - Anna Polewczyk
- Department of Physiology, Pathophysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, Kielce, Poland.,Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, Kielce, Poland
| | - Konrad Tomków
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland
| | - Paweł Stefańczyk
- Department of Cardiology, The Pope John Paul II Province Hospital, Zamość, Poland
| | - Jarosław Bródka
- Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland
| | | |
Collapse
|
7
|
Phillips P, Krahn AD, Andrade JG, Chakrabarti S, Thompson CR, Harris DJ, Forman JM, Karim SS, Sterns LD, Fedoruk LM, Partlow E, Bashir J. Treatment and Prevention of Cardiovascular Implantable Electronic Device (CIED) Infections. CJC Open 2022; 4:946-958. [DOI: 10.1016/j.cjco.2022.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 07/03/2022] [Indexed: 10/15/2022] Open
|