1
|
Ogawa ES, Matos AO, Beline T, Marques IS, Sukotjo C, Mathew MT, Rangel EC, Cruz NC, Mesquita MF, Consani RX, Barão VA. Surface-treated commercially pure titanium for biomedical applications: Electrochemical, structural, mechanical and chemical characterizations. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 65:251-61. [DOI: 10.1016/j.msec.2016.04.036] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 03/17/2016] [Accepted: 04/11/2016] [Indexed: 01/04/2023]
|
2
|
Herranz-Diez C, Gil FJ, Guillem-Marti J, Manero JM. Mechanical and physicochemical characterization along with biological interactions of a new Ti25Nb21Hf alloy for bone tissue engineering. J Biomater Appl 2015; 30:171-81. [DOI: 10.1177/0885328215577524] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Nowadays, one of the main challenges in metal implants for bone substitution is the achievement of an elastic modulus close to that of human cortical bone as well as to provide an adequate interaction with the surrounding tissue avoiding in vivo foreign body reaction. From this perspective, a new Ti-based alloy has been developed with Nb and Hf as alloying elements which are known as non-toxic and with good corrosion properties. The microstructure, mechanical behaviour and the physicochemical properties of this novel titanium alloy have been studied. Relationship of surface chemistry and surface electric charge with protein adsorption and cell adhesion has been evaluated due to its role for understanding the mechanism of biological interactions with tissues. The Ti25Nb21Hf alloy presented a lower elastic modulus than commercial alloys with a superior ultimate strength and yield strength than CP-Ti and very close to Ti6Al4V. It also exhibited good corrosion resistance. Furthermore, the results revealed that it had no cytotoxic effect on rat mesenchymal stem cells and allowed protein adsorption and cell adhesion. The experimental results make this alloy a promising material for bone substitution or for biomedical devices.
Collapse
Affiliation(s)
- C Herranz-Diez
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), Barcelona, Spain
| | - FJ Gil
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain
- Centre for Research in NanoEngineering (CRNE) – UPC, Barcelona, Spain
| | - J Guillem-Marti
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain
- Centre for Research in NanoEngineering (CRNE) – UPC, Barcelona, Spain
| | - JM Manero
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), Barcelona, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain
- Centre for Research in NanoEngineering (CRNE) – UPC, Barcelona, Spain
| |
Collapse
|
3
|
Cimpean A, Vasilescu E, Drob P, Cinca I, Vasilescu C, Anastasescu M, Mitran V, Drob SI. Enhancement of the electrochemical behaviour and biological performance of Ti–25Ta–5Zr alloy by thermo-mechanical processing. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 38:127-42. [DOI: 10.1016/j.msec.2014.01.056] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Revised: 01/15/2014] [Accepted: 01/30/2014] [Indexed: 11/16/2022]
|
4
|
Gordin DM, Gloriant T, Chane-Pane V, Busardo D, Mitran V, Höche D, Vasilescu C, Drob SI, Cimpean A. Surface characterization and biocompatibility of titanium alloys implanted with nitrogen by Hardion+ technology. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2012; 23:2953-2966. [PMID: 22918550 DOI: 10.1007/s10856-012-4750-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2012] [Accepted: 08/12/2012] [Indexed: 06/01/2023]
Abstract
In this study, the new Hardion+ micro-implanter technology was used to modify surface properties of biomedical pure titanium (CP-Ti) and Ti-6Al-4V ELI alloy by implantation of nitrogen ions. This process is based on the use of an electron cyclotron resonance ion source to produce a multienergetic ion beam from multicharged ions. After implantation, surface analysis methods revealed the formation of titanium nitride (TiN) on the substrate surfaces. An increase in superficial hardness and a significant reduction of friction coefficient were observed for both materials when compared to non-implanted samples. Better corrosion resistance and a significant decrease in ion release rates were observed for N-implanted biomaterials due to the formation of the protective TiN layer on their surfaces. In vitro tests performed on human fetal osteoblasts indicated that the cytocompatibility of N-implanted CP-Ti and Ti-6Al-4V alloy was enhanced in comparison to that of the corresponding non treated samples. Consequently, Hardion+ implantation technique can provide titanium alloys with better qualities in terms of corrosion resistance, cell proliferation, adhesion and viability.
Collapse
Affiliation(s)
- D M Gordin
- INSA Rennes, UMR CNRS 6226 Sciences Chimiques de Rennes/Chimie Métallurgie, 20 Avenue des Buttes de Coësmes, 35043, Rennes Cedex, France
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Mechanical and corrosion resistance of a new nanostructured Ti–Zr–Ta–Nb alloy. J Mech Behav Biomed Mater 2011; 4:1421-30. [DOI: 10.1016/j.jmbbm.2011.05.012] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Revised: 04/12/2011] [Accepted: 05/06/2011] [Indexed: 11/17/2022]
|