1
|
Zhang Y, Yang C, Yin S, Zhang X, Peng X, Li G. Exploration of 2D and 2.5D Conformational Designs Applied on Epoxide/Collagen-Based Integrative Biointerfaces with Device/Tissue Heterogeneous Affinity. ACS APPLIED MATERIALS & INTERFACES 2023; 15:22876-22891. [PMID: 37144968 DOI: 10.1021/acsami.3c00945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Collagen and multifunctional epoxides, which are respectively the common constituents of natural and polymer interfaces, were combined to fabricate integrative biointerfaces with device/tissue heterogeneous affinity. Further, the traditional 2D and advanced 2.5D conformational designs were achieved on collagen-based biointerfaces. The 2D conformational biointerfaces were formed by the self-entanglement of collagen molecules based on extensive hydrogen bonds among molecules, and the lamellar structures of 2D conformational biointerfaces could act as barriers to protect both biointerfaces and substrates from enzymes and corrosion. The unique stacking structures of 2.5D conformational biointerfaces were formed by cross-linking microaggregates that were established and connected by epoxy cross-linking bonds and provided the extra 0.5D degree of freedom on structure design and functional specialization through artificially manipulating the constituents and density of microaggregates. Besides, the intersecting channels among microaggregates gave 2.5D biointerfaces diffusion behaviors, which further brought good wettability and biodegradability. The integrative biointerfaces behaved well on cell viability and enhanced the cell adhesion strength in vitro, which could be attributed to the collaborations of collagen and epoxy groups. The subcutaneous implant model in rats was utilized to investigate soft tissue response, and the results demonstrated that the tissues around implantation areas healed well and without calcification or infection. The coating of integrative biointerfaces alleviated the fibrosis around implantation areas, and the inflammatory responses and foreign body reactions were improved.
Collapse
Affiliation(s)
- Yuanzhi Zhang
- National Engineering Laboratory for Clean Technology of Leather Manufacture, Sichuan University, Chengdu 610065, P.R. China
| | - Changkai Yang
- National Engineering Laboratory for Clean Technology of Leather Manufacture, Sichuan University, Chengdu 610065, P.R. China
| | - Simiao Yin
- National Engineering Laboratory for Clean Technology of Leather Manufacture, Sichuan University, Chengdu 610065, P.R. China
| | - Xiaoxia Zhang
- Key Laboratory of Leather Chemistry and Engineering (Sichuan University), Ministry of Education, Chengdu 610065, China
| | - Xu Peng
- Experimental and Research Animal Institute, Sichuan University, Chengdu 610065, China
| | - Guoying Li
- National Engineering Laboratory for Clean Technology of Leather Manufacture, Sichuan University, Chengdu 610065, P.R. China
- Key Laboratory of Leather Chemistry and Engineering (Sichuan University), Ministry of Education, Chengdu 610065, China
| |
Collapse
|
2
|
Fischer NG, Aparicio C. Junctional epithelium and hemidesmosomes: Tape and rivets for solving the "percutaneous device dilemma" in dental and other permanent implants. Bioact Mater 2022; 18:178-198. [PMID: 35387164 PMCID: PMC8961425 DOI: 10.1016/j.bioactmat.2022.03.019] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 02/14/2022] [Accepted: 03/12/2022] [Indexed: 02/06/2023] Open
Abstract
The percutaneous device dilemma describes etiological factors, centered around the disrupted epithelial tissue surrounding non-remodelable devices, that contribute to rampant percutaneous device infection. Natural percutaneous organs, in particular their extracellular matrix mediating the "device"/epithelium interface, serve as exquisite examples to inspire longer lasting long-term percutaneous device design. For example, the tooth's imperviousness to infection is mediated by the epithelium directly surrounding it, the junctional epithelium (JE). The hallmark feature of JE is formation of hemidesmosomes, cell/matrix adhesive structures that attach surrounding oral gingiva to the tooth's enamel through a basement membrane. Here, the authors survey the multifaceted functions of the JE, emphasizing the role of the matrix, with a particular focus on hemidesmosomes and their five main components. The authors highlight the known (and unknown) effects dental implant - as a model percutaneous device - placement has on JE regeneration and synthesize this information for application to other percutaneous devices. The authors conclude with a summary of bioengineering strategies aimed at solving the percutaneous device dilemma and invigorating greater collaboration between clinicians, bioengineers, and matrix biologists.
Collapse
Affiliation(s)
- Nicholas G. Fischer
- MDRCBB-Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, 16-212 Moos Tower, 515 Delaware St. SE, Minneapolis, MN, 55455, USA
| | - Conrado Aparicio
- MDRCBB-Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, 16-212 Moos Tower, 515 Delaware St. SE, Minneapolis, MN, 55455, USA
- Division of Basic Research, Faculty of Odontology, UIC Barcelona – Universitat Internacional de Catalunya, C/. Josep Trueta s/n, 08195, Sant Cugat del Valles, Barcelona, Spain
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), C/. Baldiri Reixac 10-12, 08028, Barcelona, Spain
| |
Collapse
|
3
|
Sartori M, Borsari V, Maglio M, Brogini S, Bragonzoni L, Zaffagnini S, Fini M. Skin adhesion to the percutaneous component of direct bone anchored systems: systematic review on preclinical approaches and biomaterials. Biomater Sci 2021; 9:7008-7023. [PMID: 34549759 DOI: 10.1039/d1bm00707f] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
Nowadays, direct bone anchored systems are an increasingly adopted approach in the therapeutic landscape for amputee patients. However, the percutaneous nature of these devices poses a major challenge to obtain a stable and lasting proper adhesion between the implant surface and the skin. A systematic review was carried out in three databases (PubMed, Scopus, Web of Science) to provide an overview of the innovative strategies tested with preclinical models (in vitro and in vivo) in the last ten years to improve the skin adhesion of direct bone anchored systems. Fifty five articles were selected after screening, also employing PECO question and inclusion criteria. A modified Cochrane RoB 2.0 tool for the in vitro studies and the SYRCLE tool for in in vivo studies were used to assess the risk of bias. The evidence collected suggests that the implementation of porous percutaneous structures could be one of the most favorable approach to improve proper skin adhesion, especially in association with bioactive coatings, as hydroxyapatite, and exploiting the field of nanostructure. Some issues still remain open as (a) the identification and characterization of the best material/coating association able to limit the shear stresses at the interface and (b) the role of keratinocyte turnover on the skin/biomaterial adhesion and integration processes.
Collapse
Affiliation(s)
- Maria Sartori
- IRCCS - Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Via di Barbiano 1/10, 40136, Bologna, Italy.
| | - Veronica Borsari
- IRCCS - Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Via di Barbiano 1/10, 40136, Bologna, Italy.
| | - Melania Maglio
- IRCCS - Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Via di Barbiano 1/10, 40136, Bologna, Italy.
| | - Silvia Brogini
- IRCCS - Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Via di Barbiano 1/10, 40136, Bologna, Italy.
| | - Laura Bragonzoni
- University of Bologna - Department for Life Quality Studies, Bologna, Italy
| | - Stefano Zaffagnini
- IRCCS - Istituto Ortopedico Rizzoli, II Orthopaedic and Traumatologic Clinic, Via G.C. Pupilli 1, 40136, Bologna, Italy
| | - Milena Fini
- IRCCS - Istituto Ortopedico Rizzoli, Complex Structure of Surgical Sciences and Technologies, Via di Barbiano 1/10, 40136, Bologna, Italy.
| |
Collapse
|
4
|
Pawar DRL, Jeyapalina S, Bachus KN. Evaluation of soft-tissue response around laser microgrooved titanium percutaneous devices. J Biomed Mater Res B Appl Biomater 2020; 108:2031-2040. [PMID: 31889421 DOI: 10.1002/jbm.b.34543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 10/25/2019] [Accepted: 12/08/2019] [Indexed: 01/27/2023]
Abstract
Percutaneous devices are prone to epidermal downgrowth and sinus tract formation, which can serve as a nidus for bacterial colonization and increase the risk of peri-prosthetic infection. A laser microgrooved topography has been shown to limit gingival epidermal downgrowth around dental implants. However, the efficacy of this laser microgrooved topography to limit epidermal downgrowth around nongingival percutaneous devices is yet to be investigated. In this study, devices with a porous-coated subdermal component and a percutaneous post were designed and manufactured. The proximal 2 mm section of the percutaneous post were left smooth, or were textured with either a porous coating, or with the laser microgrooved topography. The smooth and porous topographies served as controls. The devices were tested in a hairless guinea pig back model, where 18 animals were randomly assigned into three groups, with each group receiving one implant type (n = 6/group). Four weeks postimplantation, the devices with surrounding soft-tissues were harvested and processed for histological analyses. Results indicated that the laser microgrooved topography failed to prevent epidermal downgrowth (23 ± 4%) around percutaneous posts in this model. Furthermore, no significant differences (p = 0.70) in epidermal downgrowth were present between the three topographies, with all the groups exhibiting similar measures of downgrowth. Overall, these findings suggest that the laser microgrooved topography may not halt downgrowth around percutaneous devices for dermal applications.
Collapse
Affiliation(s)
- Divya R L Pawar
- Orthopaedic Research Laboratories, George E. Wahlen, Department of Veterans Affairs Medical Center & University of Utah Orthopaedic Center, Salt Lake City, Utah.,Department of Bioengineering, University of Utah, Salt Lake City, Utah
| | - Sujee Jeyapalina
- Orthopaedic Research Laboratories, George E. Wahlen, Department of Veterans Affairs Medical Center & University of Utah Orthopaedic Center, Salt Lake City, Utah.,Division of Plastic Surgery, Department of Surgery, University of Utah School of Medicine, Salt Lake City, Utah
| | - Kent N Bachus
- Orthopaedic Research Laboratories, George E. Wahlen, Department of Veterans Affairs Medical Center & University of Utah Orthopaedic Center, Salt Lake City, Utah.,Department of Bioengineering, University of Utah, Salt Lake City, Utah
| |
Collapse
|