1
|
Lucas BP, D'Addio A, Block C, Manning H, Remillard B, Leiter JC. Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration. Physiol Meas 2019; 40:065003. [PMID: 31091520 DOI: 10.1088/1361-6579/ab21af] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during diuretic-induced fluid removal. APPROACH During hemodialysis we compared change in maximum diameter of the inferior vena cava by ultrasound ([Formula: see text]) to change in relative blood volume derived from capillary hemoglobin concentration from finger-clip spectrophotometry (RBVSpHb). We grouped profiles of these measurements into three distinct shapes using an unbiased, data-driven modeling technique. METHODS Fifty patients who were not in acute heart failure underwent a mean of five paired measurements while an average of 1.3 liters of fluid was removed over 2 h during single hemodialysis sessions. [Formula: see text] changed -1.0 mm (95% CI -1.9 to -0.2 mm) and the RBVSpHb changed -1.1% (95% CI -2.7 to +0.5%), but these changes were not correlated (r -0.04, 95% CI -0.32 to +0.24). Nor was there agreement between categorization of profiles of change in the two measurements (kappa -0.1, 95% CI -0.3 to +0.1). SIGNIFICANCE [Formula: see text] and RBVSpHb estimates of blood volume do not agree during mechanical fluid removal, likely because regional changes in blood flow and pressure modify IVC dimensions as well as changes total blood volume.
Collapse
Affiliation(s)
- Brian P Lucas
- Medicine Service, White River Junction VA Medical Center, White River Junction, VT, United States of America. Geisel School of Medicine at Dartmouth College, Hanover, NH, United States of America. Author to whom any correspondence should be addressed. White River Junction VA Medical Center, 215 N Main Street, White River Junction, VT, United States of America
| | | | | | | | | | | |
Collapse
|
2
|
Tang B, Yu X, Xu L, Zhu A, Zhang Y, Huang Y. Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial. BMC Anesthesiol 2019; 19:80. [PMID: 31101083 PMCID: PMC6525351 DOI: 10.1186/s12871-019-0755-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 05/10/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Hemoglobin measurement is important for transfusion decision-making. Pulse CO-Oximetry provides real-time continuous hemoglobin (SpHb) monitoring. The triage role of SpHb trends based on hemoglobin measurements was investigated. METHODS In this diagnostic randomized controlled trial, 69 patients undergoing spine or cytoreductive surgery were randomly enrolled into SpHb-monitoring and standard-care groups. Diagnostic blood samples were drawn for CO-oximetry Hb (CoOxHb) when the SpHb decreased by 1 g/dl or at the clinician's discretion in the standard-care group. The positive predictive value (PPV) was defined as the ability to detect a decrease in CoOxHb > 1 g/dl or a CoOxHb < 10 g/dl; the PPVs were compared using Fisher's exact test. The SpHb and trend accuracies were calculated. The transfusion units and postoperative hemoglobin levels were compared. RESULTS The PPV of a decrease in CoOxHb > 1 g/dl was 93.3% in the SpHb group vs 54.5% without SpHb monitoring (p = 0.002). The PPV of CoOxHb < 10 g/dl was 86.7% vs. 50.0% for these groups (p = 0.015). The CoOxHb was never < 7 g/dl with SpHb monitoring. Sixty SpHb-CoOxHb data pairs and 28 delta pairs (ΔSpHb-ΔCoOxHb) were collected. The bias, precision and limits of agreement were - 0.29, 1.03 and - 2.30 to 1.72 g/dl, respectively. When ΔSpHb and ΔCoOxHb were > 1 g/dl, the concordance rate for changes in hemoglobin reached 100%. The delta pairs revealed a positive correlation [ΔSpHb = 0.49 * ΔCoOxHb - 0.13; r = 0.69, 95% confidence interval (0.53, 0.82)]. No significant differences were found in the transfusion volume or postoperative anemia state. CONCLUSIONS The SpHb trend tracked changes in hemoglobin satisfactorily during surgery and more accurately estimated the appropriate timing for invasive hemoglobin measurements than the clinicians. TRIAL REGISTRATION ChiCTR1800016290 (Prospective registered). Initial registration date was 24/05/2018.
Collapse
Affiliation(s)
- Bo Tang
- Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China; No.1 Shuaifuyuan, Wangfujing Street, Beijing, 100730, China
| | - Xuerong Yu
- Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China; No.1 Shuaifuyuan, Wangfujing Street, Beijing, 100730, China
| | - Li Xu
- Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China; No.1 Shuaifuyuan, Wangfujing Street, Beijing, 100730, China
| | - Afang Zhu
- Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China; No.1 Shuaifuyuan, Wangfujing Street, Beijing, 100730, China
| | - Yuelun Zhang
- Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China; No.1 Shuaifuyuan, Wangfujing Street, Beijing, 100730, China
| | - Yuguang Huang
- Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China; No.1 Shuaifuyuan, Wangfujing Street, Beijing, 100730, China.
| |
Collapse
|
4
|
Huang PH, Shih BF, Tsai YF, Chung PCH, Liu FC, Yu HP, Lee WC, Chang CJ, Lin CC. Accuracy and Trending of Continuous Noninvasive Hemoglobin Monitoring in Patients Undergoing Liver Transplantation. Transplant Proc 2017; 48:1067-70. [PMID: 27320558 DOI: 10.1016/j.transproceed.2015.12.121] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Accepted: 12/30/2015] [Indexed: 01/05/2023]
Abstract
BACKGROUND Shift in large fluid volumes and massive blood loss during liver transplantation frequently leads to rapid changes in hemoglobin (Hb) concentration; thus, to ensure adequate tissue oxygenation, accurate and rapid determination of Hb concentration is essential in transplant recipients. The Radical-7 Pulse CO-Oximeter provides a noninvasive and continuous way to monitor Hb concentration (SpHb) in real time and is an ideal candidate for use during liver transplantation. In this study, we assessed the relationship between SpHb and total Hb (tHb) obtained from arterial blood samples during surgery. METHODS Forty patients undergoing liver transplantation were enrolled in this study. tHb and time-matched SpHb were measured at 5 different phases throughout surgery. Paired SpHb and tHb levels were assessed using linear regression, Bland-Altman analysis, and the Critchley polar plot method. RESULTS A total of 161 paired measurements with sufficient signal quality were analyzed. The correlation between SpHb and tHb was 0.59 (P < .001). Bland-Altman analysis revealed that a bias between SpHb and tHb was 2.28 g/dL, and limits of agreement (LoA) were from -0.78 to 5.34 g/dL. Trending analysis showed that 87% of data were located within the acceptable trending area, indicating that the trending ability was not satisfied. CONCLUSIONS The Radical-7 Pulse CO-Oximeter was not sufficient to monitor Hb levels and trends during liver transplantation surgery in our cohort. In particular, in critical patients and in those with low Hb levels, invasive Hb measurement should be used for assessment.
Collapse
Affiliation(s)
- P H Huang
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan
| | - B F Shih
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan
| | - Y-F Tsai
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan; College of Medicine, Chang Gung University, Guishan, Taoyuan, Taiwan
| | - P C H Chung
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan; College of Medicine, Chang Gung University, Guishan, Taoyuan, Taiwan
| | - F C Liu
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan; College of Medicine, Chang Gung University, Guishan, Taoyuan, Taiwan
| | - H P Yu
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan; College of Medicine, Chang Gung University, Guishan, Taoyuan, Taiwan
| | - W C Lee
- College of Medicine, Chang Gung University, Guishan, Taoyuan, Taiwan; Department of General Surgery, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan
| | - C J Chang
- Clinical Informatics and Medical Statistics Research Center, Chang Gung University, Guishan, Taoyuan, Taiwan; Biostatistical Center for Clinical Research, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan
| | - C C Lin
- Department of Anesthesiology, Chang Gung Memorial Hospital, Guishan, Taoyuan, Taiwan; College of Medicine, Chang Gung University, Guishan, Taoyuan, Taiwan.
| |
Collapse
|
5
|
Bendjelid K, Rex S, Scheeren T, Saugel B. Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring. J Clin Monit Comput 2016; 30:129-39. [DOI: 10.1007/s10877-016-9838-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 01/27/2016] [Indexed: 11/30/2022]
|