Heines SJH, de Jongh SAM, Strauch U, van der Horst ICC, van de Poll MCG, Bergmans DCJJ. The global inhomogeneity index assessed by electrical impedance tomography overestimates PEEP requirement in patients with ARDS: an observational study. BMC Anesthesiol 2022; 22:258. [PMID: 35971060 PMCID: PMC9377133 DOI: 10.1186/s12871-022-01801-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 08/08/2022] [Indexed: 11/24/2022] Open
Abstract
Background Electrical impedance tomography (EIT) visualises alveolar overdistension and alveolar collapse and enables optimisation of ventilator settings by using the best balance between alveolar overdistension and collapse (ODCL). Besides, the global inhomogeneity index (GI), measured by EIT, may also be of added value in determining PEEP. Optimal PEEP is often determined based on the best dynamic compliance without EIT at the bedside. This study aimed to assess the effect of a PEEP trial on ODCL, GI and dynamic compliance in patients with and without ARDS. Secondly, PEEP levels from “optimal PEEP” approaches by ODCL, GI and dynamic compliance are compared. Methods In 2015–2016, we included patients with ARDS using postoperative cardiothoracic surgery patients as a reference group. A PEEP trial was performed with four consecutive incremental followed by four decremental PEEP steps of 2 cmH2O. Primary outcomes at each step were GI, ODCL and best dynamic compliance. In addition, the agreement between ODCL, GI, and dynamic compliance was determined for the individual patient. Results Twenty-eight ARDS and 17 postoperative cardiothoracic surgery patients were included. The mean optimal PEEP, according to best compliance, was 10.3 (±2.9) cmH2O in ARDS compared to 9.8 (±2.5) cmH2O in cardiothoracic surgery patients. Optimal PEEP according to ODCL was 10.9 (±2.5) in ARDS and 9.6 (±1.6) in cardiothoracic surgery patients. Optimal PEEP according to GI was 17.1 (±3.9) in ARDS compared to 14.2 (±3.4) in cardiothoracic surgery patients. Conclusions Currently, no golden standard to titrate PEEP is available. We showed that when using the GI, PEEP requirements are higher compared to ODCL and best dynamic compliance during a PEEP trial in patients with and without ARDS. Supplementary Information The online version contains supplementary material available at 10.1186/s12871-022-01801-7.
Collapse
Affiliation(s)
- Serge J H Heines
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, P.O. Box 5800, 6202, AZ, Maastricht, The Netherlands.
| | - Sebastiaan A M de Jongh
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, P.O. Box 5800, 6202, AZ, Maastricht, The Netherlands
| | - Ulrich Strauch
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, P.O. Box 5800, 6202, AZ, Maastricht, The Netherlands
| | - Iwan C C van der Horst
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, P.O. Box 5800, 6202, AZ, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Marcel C G van de Poll
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, P.O. Box 5800, 6202, AZ, Maastricht, The Netherlands.,Department of Surgery, Maastricht University Medical Centre+, P. Debyelaan 25, 6229HX, Maastricht, the Netherlands.,School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, the Netherlands
| | - Dennis C J J Bergmans
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, P.O. Box 5800, 6202, AZ, Maastricht, The Netherlands.,School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, the Netherlands
| |
Collapse
|
2
|
Rahmel T, Koniusch A, Schwertner M, Oprea G, Adamzik M, Nowak H. Evaluation of inhaled salbutamol effectiveness under supportive use of electrical impedance tomography in ventilated ICU patients: study protocol for a randomised controlled clinical trial. BMJ Open 2019; 9:e026038. [PMID: 30862635 PMCID: PMC6429886 DOI: 10.1136/bmjopen-2018-026038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 01/25/2019] [Accepted: 01/28/2019] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION The inhalative administration of drugs is a non-invasive application form that is regularly used in the treatment of ventilated patients in critical care setting. However, assessment of effectiveness or distribution of nebulised drugs is one of the lacking cornerstones of modern intensive care monitoring. Electrical impedance tomography (EIT) may provide a promising new monitoring and guiding tool for an adequate optimisation of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and evaluate associated pathologies at bedside. This study aims to elucidate the extent to which the effectiveness of inhaled salbutamol can be increased by the additional use of EIT for optimisation of respirator settings. METHODS AND ANALYSIS This study is a randomised, open-label, superiority trial conducted on an intensive care unit of a German university hospital, comparing two groups of mechanically ventilated patients with an acute or chronic bronchial airway obstruction according to the effectiveness of inhaled salbutamol with (intervention) or without (control) additional use of EIT for optimising ventilator settings. The primary outcome is change in airway resistance 30 min after salbutamol inhalation. ETHICS AND DISSEMINATION The study has received approval from the Ethics Committee of the Medical Faculty of Ruhr-University Bochum (17-6306). The results will be made available to critical care survivors, their caregivers, the funders, the critical care societies and other researchers by publication in a peer-reviewed journal. TRIAL REGISTRATION NUMBER DRKS00014706; Pre-results.
Collapse
Affiliation(s)
- Tim Rahmel
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Alexandra Koniusch
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Martin Schwertner
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Günther Oprea
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Michael Adamzik
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| | - Hartmuth Nowak
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Germany
| |
Collapse
|
3
|
Rapin M, Braun F, Adler A, Wacker J, Frerichs I, Vogt B, Chetelat O. Wearable Sensors for Frequency-Multiplexed EIT and Multilead ECG Data Acquisition. IEEE Trans Biomed Eng 2019; 66:810-820. [DOI: 10.1109/tbme.2018.2857199] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
4
|
Journal of Clinical Monitoring and Computing 2017 end of year summary: respiration. J Clin Monit Comput 2018; 32:197-205. [PMID: 29480384 DOI: 10.1007/s10877-018-0121-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Accepted: 02/22/2018] [Indexed: 12/19/2022]
Abstract
This paper reviews 32 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2016, within the field of respiration. Papers were published covering airway management, ventilation and respiratory rate monitoring, lung mechanics and gas exchange monitoring, in vitro monitoring of lung mechanics, CO2 monitoring, and respiratory and metabolic monitoring techniques.
Collapse
|
5
|
Zhao Z, Yun PJ, Kuo YL, Fu F, Dai M, Frerichs I, Möller K. Comparison of different functional EIT approaches to quantify tidal ventilation distribution. Physiol Meas 2018; 39:01NT01. [DOI: 10.1088/1361-6579/aa9eb4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|