1
|
Hilderink BN, Crane RF, van den Bogaard B, Pillay J, Juffermans NP. Hyperoxemia and hypoxemia impair cellular oxygenation: a study in healthy volunteers. Intensive Care Med Exp 2024; 12:37. [PMID: 38619625 PMCID: PMC11018572 DOI: 10.1186/s40635-024-00619-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 03/28/2024] [Indexed: 04/16/2024] Open
Abstract
INTRODUCTION Administration of oxygen therapy is common, yet there is a lack of knowledge on its ability to prevent cellular hypoxia as well as on its potential toxicity. Consequently, the optimal oxygenation targets in clinical practice remain unresolved. The novel PpIX technique measures the mitochondrial oxygen tension in the skin (mitoPO2) which allows for non-invasive investigation on the effect of hypoxemia and hyperoxemia on cellular oxygen availability. RESULTS During hypoxemia, SpO2 was 80 (77-83)% and PaO2 45(38-50) mmHg for 15 min. MitoPO2 decreased from 42(35-51) at baseline to 6(4.3-9)mmHg (p < 0.001), despite 16(12-16)% increase in cardiac output which maintained global oxygen delivery (DO2). During hyperoxic breathing, an FiO2 of 40% decreased mitoPO2 to 20 (9-27) mmHg. Cardiac output was unaltered during hyperoxia, but perfused De Backer density was reduced by one-third (p < 0.01). A PaO2 < 100 mmHg and > 200 mmHg were both associated with a reduction in mitoPO2. CONCLUSIONS Hypoxemia decreases mitoPO2 profoundly, despite complete compensation of global oxygen delivery. In addition, hyperoxemia also decreases mitoPO2, accompanied by a reduction in microcirculatory perfusion. These results suggest that mitoPO2 can be used to titrate oxygen support.
Collapse
Affiliation(s)
- Bashar N Hilderink
- Department of Intensive Care, OLVG Hospital, Amsterdam, The Netherlands.
| | - Reinier F Crane
- Department of Intensive Care, OLVG Hospital, Amsterdam, The Netherlands
| | | | - Janesh Pillay
- Department of Critical Care, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Nicole P Juffermans
- Department of Intensive Care, OLVG Hospital, Amsterdam, The Netherlands
- Laboratory of Translational Intensive Care, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
2
|
Liu B, He H, Feng X, Yuan S, Long Y, Akin Ş, Ince C. Sublingual microcirculation: comparison between the 415 nm blue light and 520 nm green light of sidestream dark field videomicroscopes. J Clin Monit Comput 2023; 37:297-302. [PMID: 35838871 DOI: 10.1007/s10877-022-00891-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 06/28/2022] [Indexed: 01/24/2023]
Abstract
Green light with a wavelength of 520 nm is commonly used in sidestream dark field (SDF) video microscopes for sublingual microcirculation assessment in clinical practice. However, blue light could obtain a clearer microcirculatory image due to a higher light absorption coefficient of hemoglobin. The aim of this study was to compare the sublingual microcirculatory image quality acquisition and related microcirculatory parameters between 520 nm green light and 415 nm blue light probes in the SDF device named MicroSee V100. Sublingual microcirculation films from twenty-one healthy volunteers were prospectively collected by blue light and green light probes, and only one video of each wavelength was recorded and analyzed in each volunteer. Moreover, 200 sublingual microcirculation films (100 by blue light probe and 100 by green light probe) of ICU patients were retrospectively scored for microcirculation image quality. Compared to green light, an increase in the perfused vessel density (paired t test, increased by 4.6 ± 4.7 mm/mm2, P < 0.0001) and total vessel density (paired t test, increased by 5.1 ± 4.6 mm/mm2, P < 0.0001) was observed by blue light in the healthy volunteers. The blue light probe had a significantly lower rate of unacceptable films than the green light probe in the 200 films of ICU patients (10/100 vs. 39/100, P < 0.0001). Blue light provides a higher microcirculatory vessel density and image quality than the existing SDF probe using green light.
Collapse
Affiliation(s)
- Bo Liu
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, China
- Department of Critical Care Medicine, affiliated hospital of Ji Ning Medical University, Jining, China
| | - Huaiwu He
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, China.
- Department of Intensive Care, Erasmus MC University Hospital Rotterdam, Rotterdam, Netherlands.
| | - Xiaokai Feng
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, China
- ICU, Hebi People's Hospital of Henan Province, Zhengzhou, China
| | - Siyi Yuan
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, China
| | - Yun Long
- Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, China
| | - Şakir Akin
- Department of Intensive Care, Erasmus MC University Hospital Rotterdam, Rotterdam, Netherlands
- Department of Intensive Care, Haga Teaching Hospital, The Hague, The Netherlands
| | - Can Ince
- Department of Intensive Care, Erasmus MC University Hospital Rotterdam, Rotterdam, Netherlands
| |
Collapse
|
3
|
Abstract
Ensuring and maintaining adequate tissue oxygenation at the microcirculatory level might be considered the holy grail of optimal hemodynamic patient management. However, in clinical practice we usually focus on macro-hemodynamic variables such as blood pressure, heart rate, and sometimes cardiac output. Other macro-hemodynamic variables like pulse pressure or stroke volume variation are additionally used as markers of fluid responsiveness. In recent years, an increasing number of technological devices assessing tissue oxygenation or microcirculatory blood flow have been developed and validated, and some of them have already been incorporated into clinical practice. In this review, we will summarize recent research findings on this topic as published in the last 2 years in the Journal of Clinical Monitoring and Computing (JCMC). While some techniques are already currently used as routine monitoring (e.g. cerebral oxygenation using near-infrared spectroscopy (NIRS)), others still have to find their way into clinical practice. Therefore, further research is needed, particularly regarding outcome measures and cost-effectiveness, since introducing new technology is always expensive and should be balanced by downstream savings. The JCMC is glad to provide a platform for such research.
Collapse
|
4
|
Dubin A, Kanoore Edul VS, Caminos Eguillor JF, Ferrara G. Monitoring Microcirculation: Utility and Barriers - A Point-of-View Review. Vasc Health Risk Manag 2020; 16:577-589. [PMID: 33408477 PMCID: PMC7780856 DOI: 10.2147/vhrm.s242635] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 11/27/2020] [Indexed: 12/22/2022] Open
Abstract
Microcirculation is a particular organ of the cardiovascular system. The goal of this narrative review is a critical reappraisal of the present knowledge of microcirculation monitoring, mainly focused on the videomicroscopic evaluation of sublingual microcirculation in critically ill patients. We discuss the technological developments in handheld videomicroscopy, which have resulted in adequate tools for the bedside monitoring of microcirculation. By means of these techniques, a large body of evidence has been acquired about the role of microcirculation in the pathophysiological mechanisms of shock, especially septic shock. We review the characteristics of sublingual microcirculation in septic shock, which mainly consist in a decrease in the perfused vascular density secondary to a reduction in the proportion of perfused vessels along with a high heterogeneity in perfusion. Even in patients with high cardiac output, red blood cell velocity is decreased. Thus, hyperdynamic flow is absent in the septic microcirculation. We also discuss the dissociation between microcirculation and systemic hemodynamics, particularly after shock resuscitation, and the different behavior among microvascular beds. In addition, we briefly comment the effects of some treatments on microcirculation. Despite the fact that sublingual microcirculation arises as a valuable goal for the resuscitation in critically ill patients, significant barriers remain present for its clinical application. Most of them are related to difficulties in video acquisition and analysis. We comprehensively analyzed these shortcomings. Unfortunately, a simpler approach, such as the central venous minus arterial PCO2 difference, is a misleading surrogate for sublingual microcirculation. As conclusion, the monitoring of sublingual microcirculation is an appealing method for monitoring critically ill patients. Nevertheless, the lack of controlled studies showing benefits in terms of outcome, as well as technical limitations for its clinical implementation, render this technique mainly as a research tool.
Collapse
Affiliation(s)
- Arnaldo Dubin
- Cátedra de Farmacología Aplicada, Facultad de Ciencias Médicas, Universidad Nacional de La Plata, La Plata, Argentina
| | | | | | - Gonzalo Ferrara
- Cátedra de Farmacología Aplicada, Facultad de Ciencias Médicas, Universidad Nacional de La Plata, La Plata, Argentina
| |
Collapse
|