• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4605784)   Today's Articles (189)   Subscriber (49373)
For: Chang YJ, Chen CH, Hsieh BT. Characterization of long-term dose stability of N-isopropylacrylamide polymer gel dosimetry. J Radioanal Nucl Chem 2014. [DOI: 10.1007/s10967-014-3231-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Yao CH, Huang EY, Juan KJ, Juang PJ, Juan YH, Chang YJ. Feasibility evaluation of N-Isopropyl Acrylamide 3D gel dosimeters for proton therapy. PLoS One 2023;18:e0291507. [PMID: 37699042 PMCID: PMC10497135 DOI: 10.1371/journal.pone.0291507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 08/30/2023] [Indexed: 09/14/2023]  Open
2
Abtahi SMM, Kargar Shaker Langaroodi R, Akbari ME. Dose distribution verification in intraoperative radiation therapy using an N-isopropyl acrylamide-based polymer gel dosimeter. J Radioanal Nucl Chem 2020. [DOI: 10.1007/s10967-020-07110-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
3
Xie WH, Su CT, Kao YCJ, Chang TH, Chang YJ, Yao CH, Hsieh BY. Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging. Med Phys 2020;47:1404-1410. [PMID: 31950500 DOI: 10.1002/mp.14020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 12/26/2019] [Accepted: 12/26/2019] [Indexed: 12/31/2022]  Open
4
A study of dose verification and comparison for complex irradiation field with high dose rate radiation by using a 3D N-isopropylacrylamide gel dosimeter. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06828-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
5
Response overshoot: a challenge for the application of polymer gel dosimeters. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06658-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
6
Three-dimensional dose comparison of flattening filter (FF) and flattening filter-free (FFF) radiation therapy by using NIPAM gel dosimetry. PLoS One 2019;14:e0212546. [PMID: 30789968 PMCID: PMC6383886 DOI: 10.1371/journal.pone.0212546] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2018] [Accepted: 02/05/2019] [Indexed: 12/21/2022]  Open
7
Xiong J, Han J, Tian J, Liu Y, Xi Z, Du W, Wu X, Hu S, Jiang T, Wang X. Simulation of irradiation uniformity for polyethylene and polypropylene in various high energy fields. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2018.05.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
8
Dose verification of volumetric modulation arc therapy by using a NIPAM gel dosimeter combined with a parallel-beam optical computed tomography scanner. J Radioanal Nucl Chem 2017. [DOI: 10.1007/s10967-016-5161-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
9
Image reconstruction of optical computed tomography by using the algebraic reconstruction technique for dose readouts of polymer gel dosimeters. Phys Med 2015;31:942-947. [PMID: 26165178 DOI: 10.1016/j.ejmp.2015.06.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 06/05/2015] [Accepted: 06/23/2015] [Indexed: 11/20/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA