1
|
Zhang H, Hou X, Qiao J, Lin J. Determination of 241Am in Environmental Samples: A Review. Molecules 2022; 27:4536. [PMID: 35889408 PMCID: PMC9315525 DOI: 10.3390/molecules27144536] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/11/2022] [Accepted: 07/12/2022] [Indexed: 02/04/2023] Open
Abstract
The determination of 241Am in the environment is of importance in monitoring its release and assessing its environmental impact and radiological risk. This paper aims to give an overview about the recent developments and the state-of-art analytical methods for 241Am determination in environmental samples. Thorough discussions are given in this paper covering a wide range of aspects, including sample pre-treatment and pre-concentration methods, chemical separation techniques, source preparation, radiometric and mass spectrometric measurement techniques, speciation analyses, and tracer applications. The paper focuses on some hyphenated separation methods based on different chromatographic resins, which have been developed to achieve high analytical efficiency and sample throughput for the determination of 241Am. The performances of different radiometric and mass spectrometric measurement techniques for 241Am are evaluated and compared. Tracer applications of 241Am in the environment, including speciation analyses of 241Am, and applications in nuclear forensics are also discussed.
Collapse
Affiliation(s)
- Haitao Zhang
- Northwest Institute of Nuclear Technology, Xi’an 710024, China; (H.Z.); (J.L.)
| | - Xiaolin Hou
- Department of Environmental and Resource Engineering, Technical University of Denmark, DTU Risø Campus, 4000 Roskilde, Denmark;
| | - Jixin Qiao
- Department of Environmental and Resource Engineering, Technical University of Denmark, DTU Risø Campus, 4000 Roskilde, Denmark;
| | - Jianfeng Lin
- Northwest Institute of Nuclear Technology, Xi’an 710024, China; (H.Z.); (J.L.)
| |
Collapse
|
2
|
Luo M, Liu D, Yang Y, Dai X, Wu Y, Shi K. Simultaneous determination of actinides and 90Sr in large-size soil and sediment samples. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY 2022; 247:106854. [PMID: 35276606 DOI: 10.1016/j.jenvrad.2022.106854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 03/02/2022] [Accepted: 03/03/2022] [Indexed: 06/14/2023]
Abstract
A simultaneous analytical method for sequential separation and determination of actinides and 90Sr in large-size environmental samples has been developed. In this method, successive co-precipitation steps were firstly conducted to remove matrix elements, then sequential column separation method was applied for simultaneous separation and purification of actinides and 90Sr/90Y. By using vacuum box technology, the total analytical time was minimized and batch processing allowed analyzing 12 samples in four days. The activity of 90Sr was obtained immediately by measuring its daughter radionuclide (90Y) with triple-to-double coincidence ratio (TDCR) Cherenkov counting, while the concentrations of Pu isotopes and 241Am could be measured by alpha spectrometry and mass spectrometric techniques. The overall recoveries of Pu, Am, Sr and Y were higher than 70% for the entire procedure, while the recovery ratios of Sr/Y were between 0.95 and 1.04 before chromatographic separation. The developed method was verified using 20 g and 50 g of environmental soil samples spiked with certified reference materials IAEA-384 or IAEA-385 and standard solution of 90Sr/90Y, and good agreement between the expected values and measured results has been achieved.
Collapse
Affiliation(s)
- Maoyi Luo
- China Institute for Radiation Protection, Taiyuan, China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, China
| | - Daqian Liu
- China Institute for Radiation Protection, Taiyuan, China
| | - Yao Yang
- China Institute for Radiation Protection, Taiyuan, China
| | - Xiongxin Dai
- China Institute for Radiation Protection, Taiyuan, China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, China.
| | - Yang Wu
- China Institute for Radiation Protection, Taiyuan, China
| | - Keliang Shi
- Radiochemistry Lab, School of Nuclear Science and Technology, Lanzhou University, Lanzhou, China
| |
Collapse
|
3
|
Wang W, Evans RD, Evans HE. A rapid, automated system for the separation, preconcentration and measurement of 90Sr, and U, Am and Pu isotopes. Talanta 2021; 233:122507. [PMID: 34215122 DOI: 10.1016/j.talanta.2021.122507] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 05/04/2021] [Accepted: 05/05/2021] [Indexed: 11/29/2022]
Abstract
An online separation and preconcentration method, using an automated flow injection setup and solid phase extraction followed by ICP-MS/MS, was developed for the analysis of 90Sr, and U, Am and Pu isotopes in various liquid sample matrices. The radionuclide analytes were separated from interferences and complex matrices using DGA-branched resin and Sr resin, then specific gases were used in the reaction/collision cell in the ICP-MS/MS to measure the different analytes. The system requires smaller sample volumes (10 mL), less sample preparation and shorter processing time (46 min per sample) compared to traditional radiometric and other MS techniques. Based on a 10 mL sample, the limits of detection were 1.48 pg L-1 (8257 mBq L-1) for 90Sr, 1.75 pg L-1 (0.40 mBq L-1) for 234U, 0.65 pg L-1 (77.65 mBq L-1) for 241Am, and 0.56 pg L-1 (1.25 mBq L-1) for 239Pu when all target analytes were measured in one analysis. The analytical figures of merit were evaluated for a range of sample matrices including lake water, seawater and urine and were comparable to those reported in the literature. This online system thus provides a novel, fully automated analytical tool with faster analysis time, smaller sample requirements, minimum sample preparation, low detection limits and the flexibility to handle single and multiple measurements of various radionuclides.
Collapse
Affiliation(s)
- Wei Wang
- Environmental and Life Sciences Graduate Program, Trent University, 1600, West Bank Drive, Peterborough, Ontario, K9L 0G2, Canada.
| | - R Douglas Evans
- School of the Environment and Water Quality Center, Trent University, 1600 West Bank Drive, Peterborough, Ontario, K9L 0G2, Canada
| | - Hayla E Evans
- School of the Environment and Water Quality Center, Trent University, 1600 West Bank Drive, Peterborough, Ontario, K9L 0G2, Canada
| |
Collapse
|
4
|
Dalencourt C, Chabane MN, Tremblay-Cantin JC, Larivière D. A rapid sequential chromatographic separation of U- and Th-decay series radionuclides in water samples. Talanta 2020; 207:120282. [DOI: 10.1016/j.talanta.2019.120282] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 08/19/2019] [Accepted: 08/19/2019] [Indexed: 10/26/2022]
|
5
|
Geraldo B, de Araujo LG, Taddei MHT, Ferreira MT, Máduar MF, Vicente R, Marumo JT. Radiochemical characterization of spent filter cartridges from the primary circuit of a research reactor. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06864-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
6
|
Design and performance of an automated single column sequential extraction chromatographic system. J Radioanal Nucl Chem 2019. [DOI: 10.1007/s10967-019-06642-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
7
|
Rondahl SH, Ramebäck H. Evaluation of different methods for measuring 89Sr and 90Sr: Measurement uncertainty for the different methods as a function of the activity ratio. Appl Radiat Isot 2018; 140:87-95. [PMID: 29966938 DOI: 10.1016/j.apradiso.2018.06.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 06/15/2018] [Accepted: 06/20/2018] [Indexed: 10/28/2022]
Abstract
In case of a radiological emergency situation involving e.g. fission of uranium or plutonium, analysis of radioactive strontium will be of importance. The primary radionuclides of interest are 90Sr, its progeny 90Y and 89Sr. A few days following an event, 89Sr will be the predominant radioisotope of strontium. Most methods found in the literature are valid and applicable when measuring 90Sr, but when samples contain both 89Sr/90Sr interference problematics arise. How these interferences are dealt with will have an effect on the uncertainty of the 90Sr determination. This work aims at evaluating three measurement approaches, all mentioned in the literature, with respect to the measurement uncertainty when determining 90Sr in an emergency preparedness situation and to propose a suitable measurement strategy.
Collapse
Affiliation(s)
- Stina Holmgren Rondahl
- Swedish Defence Research Agency (FOI), CBRN Defence and Security, Cementvägen 20, 901 82 Umeå, Sweden.
| | - Henrik Ramebäck
- Swedish Defence Research Agency (FOI), CBRN Defence and Security, Cementvägen 20, 901 82 Umeå, Sweden; Chalmers University of Technology, Department of Chemistry and Chemical Engineering, Nuclear Chemistry, 412 96 Göteborg, Sweden
| |
Collapse
|
8
|
Wang Z, Lin J, Li S, Guo Q, Huang W, Wen W, Dan G, Tan Z. Rapid method for accurate determination of actinides (U, Th, Pu and Am) in water samples for emergency response. J Radioanal Nucl Chem 2017. [DOI: 10.1007/s10967-017-5640-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
9
|
Habibi A, Cariou N, Boulet B, Cossonnet C, Gurriaran R, Gleizes M, Cote G, Larivière D. Automated chromatographic separation coupled on-line to ICP-MS measurements for the quantification of actinides and radiostrontium in soil samples. J Radioanal Nucl Chem 2017. [DOI: 10.1007/s10967-017-5360-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
10
|
Ma Q, Feng ZG, Liu P, Lin XK, Li ZG, Chen MS. Uranium speciation and in situ leaching of a sandstone-type deposit from China. J Radioanal Nucl Chem 2016. [DOI: 10.1007/s10967-016-5154-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|