Nagayasu M, Takano Y, Ozeki K. Development of a New Method to Evaluate the Biodistribution of Antibodies Using Non-Radioactive Metal Labeling and Inductively Coupled Plasma Mass Spectrometry.
Pharm Res 2023;
40:1807-1819. [PMID:
37266817 DOI:
10.1007/s11095-023-03541-w]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 05/21/2023] [Indexed: 06/03/2023]
Abstract
PURPOSE
The use of radiolabeled compounds is associated with a number of limitations. Therefore, a new method for the radioisotope-free evaluation of antibody distribution using metal labeling and inductively coupled plasma-mass spectrometry (ICP-MS) was developed herein.
METHODS
Indium-labeled monoclonal antibodies were administrated intravenously to tumor-bearing mice and cynomolgus monkeys, and antibody concentrations in plasma and tissues were measured by ICP-MS. The results were compared with those obtained using a ligand binding assay (LBA) and radioisotope-labeled antibody administration. Indium-, terbium-, holmium-, and yttrium-labeled cetuximab were co-administered to one C57BL/6 J mouse for simultaneous PK and tissue distribution evaluations.
RESULTS
The administration of a radioactive or non-radioactive indium-labeled anti-human interleukin-6 receptor (hIL-6R) antibody to tumor-bearing hIL-6R transgenic mice resulted in similar plasma antibody concentration-time profiles by ICP-MS, a ligand binding assay (LBA), and gamma-ray detector. Liver, kidney, brain, spleen, and tumor concentrations of antibodies measured by ICP-MS were similar to those after the administration of radiolabeled anti-hIL-6R antibodies. Following the administration of indium-labeled cetuximab to cynomolgus monkeys, plasma antibody concentrations measured by ICP-MS were similar to those measured by LBA, and antibody concentrations in organs were evaluable by ICP-MS. The PK of all metals were similar to antibody PK evaluated by LBA, and concentrations in each tissue were equivalent among metals.
CONCLUSIONS
The assessment of antibody distribution using ICP-MS is a novel alternative to the traditional radiolabeled approach. It facilitates the assessment of antibody distribution in the early stages of drug discovery and accelerates the assessment of target engagement.
Collapse