1
|
Gettler RC, Mehregan S, Koenig HD, Kaess AM, Young MJ. Nonequilibrium Anion Detection in Solid-Contact Ion-Selective Electrodes. ACS OMEGA 2024; 9:16443-16457. [PMID: 38617695 PMCID: PMC11007695 DOI: 10.1021/acsomega.4c00131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 03/08/2024] [Accepted: 03/15/2024] [Indexed: 04/16/2024]
Abstract
Low-cost and portable nitrate and phosphate sensors are needed to improve farming efficiency and reduce environmental and economic impact arising from the release of these nutrients into waterways. Ion selective electrodes (ISEs) could provide a convenient platform for detecting nitrate and phosphate, but existing ionophore-based nitrate and phosphate selective membrane layers used in ISEs are high cost, and ISEs using these membrane layers suffer from long equilibration time, reference potential drift, and poor selectivity. In this work, we demonstrate that constant current operation overcomes these shortcomings for ionophore-based anion-selective ISEs through a qualitatively different response mechanism arising from differences in ion mobility rather than differences in ion binding thermodynamics. We develop a theoretical treatment of phase boundary potential and ion diffusion that allows for quantitative prediction of electrode response under applied current. We also demonstrate that under pulsed current operation, we can create functional solid-contact ISEs using lower-cost molecularly imprinted polymers (MIPs). MIP-based nitrate sensors provide comparable selectivity against chloride to costlier ionophore-based sensors and exhibit >100,000 times higher selectivity against perchlorate. Likewise, MIP-based solid contact ion-selective electrode phosphate sensors operated under pulsed current provide competitive selectivity against chloride, nitrate, perchlorate, and carbonate anions. The theoretical treatment and conceptual demonstration of pulsed-current ISE operation we report will inform the development of new materials for membrane layers in ISEs based on differences in ion mobility and will allow for improved ISE sensor designs.
Collapse
Affiliation(s)
- Ryan C. Gettler
- Chemical
and Biomedical Engineering, University of
Missouri, Columbia, Missouri 65211, United States
| | - Shima Mehregan
- Department
of Chemistry, University of Missouri, Columbia, Missouri 65211, United States
| | - Henry D. Koenig
- Department
of Chemistry, University of Missouri, Columbia, Missouri 65211, United States
| | - Andie M. Kaess
- Chemical
and Biomedical Engineering, University of
Missouri, Columbia, Missouri 65211, United States
| | - Matthias J. Young
- Chemical
and Biomedical Engineering, University of
Missouri, Columbia, Missouri 65211, United States
- Department
of Chemistry, University of Missouri, Columbia, Missouri 65211, United States
- Materials
Science and Engineering Institute, University
of Missouri, Columbia, Missouri 65211, United States
| |
Collapse
|
2
|
Morawska K, Wardak C. Application of ionic liquids in ion-selective electrodes and reference electrodes: A review. Chemphyschem 2024; 25:e202300818. [PMID: 38252078 DOI: 10.1002/cphc.202300818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 12/21/2023] [Accepted: 01/19/2024] [Indexed: 01/23/2024]
Abstract
Ionic liquids (ILs) are organic chemical compounds that are composed only of ions, a large organic cation and a smaller inorganic or organic anion. These are salts whose melting point is lower than the boiling point of water. ILs have many interesting properties, thanks to which they find great practical applications in analytics, electrochemistry, separation techniques, catalysis and others. One of the many areas of application of ionic liquids is sensors especially electrochemical sensors including ion-selective electrodes. In this case, the properties of ILs that are particularly useful include very good electrical conductivity, high electrochemical stability, good extraction properties, hydrophobic character and compatibility with other materials, e. g. polyvinyl chloride plasticizers or carbon nanomaterials. ILs were used as components of ion-selective membranes, both polymeric ones based on PVC and membranes in carbon paste electrodes. ILs performed various functions in these membranes, including lipophilic ionic additive, ionophore/ion exchanger, plasticizer, transducer media and matrix. They were also used as a component of the intermediate layer in solid contact ISEs. The last chapter presents examples of the use of ILs in reference electrodes. This review discusses the use of ionic liquids in ion-selective electrodes (ISEs) and reference electrodes over the last ten years.
Collapse
Affiliation(s)
- Klaudia Morawska
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031, Lublin, Poland
| | - Cecylia Wardak
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031, Lublin, Poland
| |
Collapse
|
3
|
Pershina LV, Grabeklis AR, Isankina LN, Skorb EV, Nikolaev KG. Determination of sodium and potassium ions in patients with SARS-Cov-2 disease by ion-selective electrodes based on polyelectrolyte complexes as a pseudo-liquid contact phase. RSC Adv 2021; 11:36215-36221. [PMID: 35492756 PMCID: PMC9043442 DOI: 10.1039/d1ra04582b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 10/09/2021] [Indexed: 11/21/2022] Open
Abstract
Nowadays, there are several methods for the detection of various bioelements during SARS-CoV-2. Many of them require special equipment, high expenses, and a long time to obtain results. In this study, we aim to use polyelectrolyte multilayers for robust carbon fiber-based potentiometric sensing to determine the ion concentration in human biofluids of COVID-19 patients. The polyethyleneimine/polystyrene sulfonate complex is hygroscopic and has the ability to retain counterions of inorganic salts. This fact makes it possible to create a flexible ionometric system with a pseudo-liquid connection. The formation of the polyethyleneimine/polystyrene sulfonate complex allows for the adhesion of a hydrophobic ion-selective membrane, and creates a Nernst response in a miniature sensor system. This approach discloses the development of miniaturized ion-selective electrodes and their future application to monitor analyte changes as micro and macroelement ions in the human body to identify correlation to SARS-CoV-2. An imbalance in the content of potassium and sodium in urine and blood is directly related to changes in the zinc content in patients with coronavirus. The proposed method for assessing the condition of patients will allow fast determination of the severity of the course of the disease.
Collapse
Affiliation(s)
- Liubov V Pershina
- Infochemistry Scientific Center of ITMO University 191002 Saint Petersburg Russian Federation
| | - Andrei R Grabeklis
- World-Class Research Center "Digital Biodesign and Personalized Healthcare", Sechenov First Moscow State Medical University Trubetskaya st., 8 119991 Moscow Russian Federation
- Peoples' Friendship University of Russia (RUDN University) Miklukho-Maklay st., 6 Moscow 117198 Russian Federation
| | - Ludmila N Isankina
- Children's City Clinical Hospital No. 5 named after N.F. Filatov 192889 Saint Petersburg Russian Federation
| | - Ekaterina V Skorb
- Infochemistry Scientific Center of ITMO University 191002 Saint Petersburg Russian Federation
| | - Konstantin G Nikolaev
- Infochemistry Scientific Center of ITMO University 191002 Saint Petersburg Russian Federation
| |
Collapse
|
4
|
Cheong YH, Ge L, Lisak G. Highly reproducible solid contact ion selective electrodes: Emerging opportunities for potentiometry - A review. Anal Chim Acta 2021; 1162:338304. [PMID: 33926699 DOI: 10.1016/j.aca.2021.338304] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/20/2021] [Accepted: 02/04/2021] [Indexed: 02/07/2023]
Abstract
The solid contact ion-selective electrodes (SC-ISEs) have been extensively studied in the field of ion sensing as they offer the possibility of miniaturization, are relatively inexpensive in comparison to other analytical techniques and allow straightforward and routine analyses of ions in a number of clinical, environmental and industrial process samples. In recent years, significant interest has grown in the development of SC-ISEs with well-defined interfacialpotentials at the membrane, solid contact, and substrate electrode interfaces. This has resulted in interesting SC-ISEs exhibiting high electrode-to-electrode potential reproducibility, for those made in a single batch of electrodes, some approaching or exceeding those observed in liquid-contact ISEs. The advancement in the potential reproducibility of SC-ISEs has been partially achieved by scrutinizing insufficiently reproducible fabrication methods of SC-ISEs, or by introducing novel control measures or modifiers to components of the ISEs. This paper provides an overview of the methods as well as the challenges in establishing and maintaining reproducible potentials during the fabrication and use of novel SC-ISEs. The rules outlined in the works reviewed may form the basis of further development of cost-effective, user-friendly, limited calibration or calibration-free potentiometric SC-ISEs to achieve reliable ion analyses here and now.
Collapse
Affiliation(s)
- Yi Heng Cheong
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore; Robert Bosch (South East Asia) Pte Ltd, 11 Bishan Street 21, Singapore, 573943, Singapore; Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, Singapore, 637141, Singapore
| | - Liya Ge
- Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, Singapore, 637141, Singapore
| | - Grzegorz Lisak
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore; Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, Singapore, 637141, Singapore.
| |
Collapse
|
5
|
Palani P, Karpagam S. Conjugated polymers – a versatile platform for various photophysical, electrochemical and biomedical applications: a comprehensive review. NEW J CHEM 2021. [DOI: 10.1039/d1nj04062f] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Tuneable properties of conjugated polymers are attractive for use in multiple domains like optical, electronic and biological applications.
Collapse
Affiliation(s)
- Purushothaman Palani
- Department of Chemistry, School of Advanced Sciences, VIT University, Vellore-14, Tamil Nadu, India
| | - Subramanian Karpagam
- Department of Chemistry, School of Advanced Sciences, VIT University, Vellore-14, Tamil Nadu, India
| |
Collapse
|
6
|
Shao Y, Ying Y, Ping J. Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends. Chem Soc Rev 2020; 49:4405-4465. [DOI: 10.1039/c9cs00587k] [Citation(s) in RCA: 143] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This article presents a comprehensive overview of recent progress in the design and applications of solid-contact ion-selective electrodes (SC-ISEs).
Collapse
Affiliation(s)
- Yuzhou Shao
- Laboratory of Agricultural Information Intelligent Sensing
- School of Biosystems Engineering and Food Science
- Zhejiang University
- Hangzhou
- China
| | - Yibin Ying
- Laboratory of Agricultural Information Intelligent Sensing
- School of Biosystems Engineering and Food Science
- Zhejiang University
- Hangzhou
- China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent Sensing
- School of Biosystems Engineering and Food Science
- Zhejiang University
- Hangzhou
- China
| |
Collapse
|
7
|
Zhao L, Jiang Y, Wei H, Jiang Y, Ma W, Zheng W, Cao AM, Mao L. In Vivo Measurement of Calcium Ion with Solid-State Ion-Selective Electrode by Using Shelled Hollow Carbon Nanospheres as a Transducing Layer. Anal Chem 2019; 91:4421-4428. [DOI: 10.1021/acs.analchem.8b04944] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Lijun Zhao
- Institute of Surface/Interface Science and Technology, Key Laboratory of Superlight Material and Surface Technology of Ministry of Education, College of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001, China
| | - Ying Jiang
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Key Laboratory of Molecular Nanostructure and Nanotechnology, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
| | - Huan Wei
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Key Laboratory of Molecular Nanostructure and Nanotechnology, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yanan Jiang
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Key Laboratory of Molecular Nanostructure and Nanotechnology, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wenjie Ma
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Key Laboratory of Molecular Nanostructure and Nanotechnology, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Zheng
- Institute of Surface/Interface Science and Technology, Key Laboratory of Superlight Material and Surface Technology of Ministry of Education, College of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001, China
| | - An-Min Cao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Key Laboratory of Molecular Nanostructure and Nanotechnology, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Key Laboratory of Molecular Nanostructure and Nanotechnology, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
8
|
Timofeev VV, Levin MB, Starikova AA, Trofimov MA, Korneev SM, Mikhelson KN. Solid-Contact Ion-Selective Electrodes with Copper Hexacyanoferrate in the Transducer Layer. RUSS J ELECTROCHEM+ 2018. [DOI: 10.1134/s1023193518040080] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
9
|
Towards stabilization of the potential response of Mn(III) tetraphenylporphyrin-based solid-state electrodes with selectivity for salicylate ions. J Solid State Electrochem 2017. [DOI: 10.1007/s10008-017-3575-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
10
|
Nery EW, Kubota LT. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine. Anal Chim Acta 2016; 918:60-8. [PMID: 27046211 DOI: 10.1016/j.aca.2016.03.004] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2015] [Revised: 02/04/2016] [Accepted: 03/03/2016] [Indexed: 12/20/2022]
Abstract
The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca(2+)/Mg(2+), K(+)/Na(+)) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only describes new paper-based, potentiometric sensors but also according to our knowledge is the first description of an electrochemical paper-based electronic tongue with integrated reference.
Collapse
Affiliation(s)
- Emilia Witkowska Nery
- Department of Analytical Chemistry, Institute of Chemistry - UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP, Brazil; National Institute of Science and Technology in Bioanalytics, Institute of Chemistry - UNICAMP, P.O. Box 6154, Campinas, Brazil.
| | - Lauro T Kubota
- Department of Analytical Chemistry, Institute of Chemistry - UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP, Brazil; National Institute of Science and Technology in Bioanalytics, Institute of Chemistry - UNICAMP, P.O. Box 6154, Campinas, Brazil
| |
Collapse
|
11
|
Mikhelson KN, Peshkova MA. Advances and trends in ionophore-based chemical sensors. RUSSIAN CHEMICAL REVIEWS 2015. [DOI: 10.1070/rcr4506] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
12
|
Wang L, Yang D, Fang C, Chen Z, Lesniewski PJ, Mallavarapu M, Naidu R. Application of neural networks with novel independent component analysis methodologies to a Prussian blue modified glassy carbon electrode array. Talanta 2015; 131:395-403. [DOI: 10.1016/j.talanta.2014.08.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Revised: 08/04/2014] [Accepted: 08/05/2014] [Indexed: 12/01/2022]
|
13
|
Khalil MM, Issa YM, Mohamed AG. Construction and Performance Characterization of Ion-Selective Electrodes for Potentiometric Determination of Paroxetine Hydrochloride in Pharmaceutical Preparations and Biological Fluids. ELECTROANAL 2014. [DOI: 10.1002/elan.201400366] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
14
|
Vanamo U, Bobacka J. Instrument-Free Control of the Standard Potential of Potentiometric Solid-Contact Ion-Selective Electrodes by Short-Circuiting with a Conventional Reference Electrode. Anal Chem 2014; 86:10540-5. [DOI: 10.1021/ac501464s] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Ulriika Vanamo
- Laboratory of Analytical
Chemistry, Process
Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, 20500 Turku-Åbo, Finland
| | - Johan Bobacka
- Laboratory of Analytical
Chemistry, Process
Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, 20500 Turku-Åbo, Finland
| |
Collapse
|