1
|
Zhao Y, Li S, He X, Yu J, Zhang L, Zhang H, Wei D, Wang B, Li J, Guo H, He X. Liver injury monitoring using dynamic fluorescence molecular tomography based on a time-energy difference strategy. BIOMEDICAL OPTICS EXPRESS 2023; 14:5298-5315. [PMID: 37854546 PMCID: PMC10581805 DOI: 10.1364/boe.498092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 09/03/2023] [Accepted: 09/05/2023] [Indexed: 10/20/2023]
Abstract
Dynamic fluorescence molecular tomography (DFMT) is a promising molecular imaging technique that offers the potential to monitor fast kinetic behaviors within small animals in three dimensions. Early monitoring of liver disease requires the ability to distinguish and analyze normal and injured liver tissues. However, the inherent ill-posed nature of the problem and energy signal interference between the normal and injured liver regions limit the practical application of liver injury monitoring. In this study, we propose a novel strategy based on time and energy, leveraging the temporal correlation in fluorescence molecular imaging (FMI) sequences and the metabolic differences between normal and injured liver tissue. Additionally, considering fluorescence signal distribution disparity between the injured and normal regions, we designed a universal Golden Ratio Primal-Dual Algorithm (GRPDA) to reconstruct both the normal and injured liver regions. Numerical simulation and in vivo experiment results demonstrate that the proposed strategy can effectively avoid signal interference between liver and liver injury energy and lead to significant improvements in morphology recovery and positioning accuracy compared to existing approaches. Our research presents a new perspective on distinguishing normal and injured liver tissues for early liver injury monitoring.
Collapse
Affiliation(s)
- Yizhe Zhao
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Shuangchen Li
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Xuelei He
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Jingjing Yu
- School of Physics and Information Technology, Shaanxi Normal University, Xi'an, 710062, China
| | - Lizhi Zhang
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Heng Zhang
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - De Wei
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Beilei Wang
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Jintao Li
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Hongbo Guo
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Xiaowei He
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| |
Collapse
|
2
|
Zhang L, Guo H, Li J, Kang D, Zhang D, He X, Zhao Y, Wei D, Yu J. Multi-target reconstruction strategy based on blind source separation of surface measurement signals in FMT. BIOMEDICAL OPTICS EXPRESS 2023; 14:1159-1177. [PMID: 36950247 PMCID: PMC10026579 DOI: 10.1364/boe.481348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/30/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Fluorescence molecular tomography (FMT) is a promising molecular imaging technique for tumor detection in the early stage. High-precision multi-target reconstructions are necessary for quantitative analysis in practical FMT applications. The existing reconstruction methods perform well in retrieving a single fluorescent target but may fail in reconstructing a multi-target, which remains an obstacle to the wider application of FMT. In this paper, a novel multi-target reconstruction strategy based on blind source separation (BSS) of surface measurement signals was proposed, which transformed the multi-target reconstruction problem into multiple single-target reconstruction problems. Firstly, by multiple points excitation, multiple groups of superimposed measurement signals conforming to the conditions of BSS were constructed. Secondly, an efficient nonnegative least-correlated component analysis with iterative volume maximization (nLCA-IVM) algorithm was applied to construct the separation matrix, and the superimposed measurement signals were separated into the measurements of each target. Thirdly, the least squares fitting method was combined with BSS to determine the number of fluorophores indirectly. Lastly, each target was reconstructed based on the extracted surface measurement signals. Numerical simulations and in vivo experiments proved that it has the ability of multi-target resolution for FMT. The encouraging results demonstrate the significant effectiveness and potential of our method for practical FMT applications.
Collapse
Affiliation(s)
- Lizhi Zhang
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Hongbo Guo
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Jintao Li
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Dizhen Kang
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Diya Zhang
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Xiaowei He
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Yizhe Zhao
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - De Wei
- The Xi’an Key Laboratory of Radiomics and Intelligent Perception, Xi’an, China
- School of Information Sciences and Technology, Northwest University, Xi’an 710127, China
| | - Jingjing Yu
- School of Physics and Information Technology, Shaanxi Normal University, Xi’an 710062, China
| |
Collapse
|
3
|
Wang Y, Zhang H, Guo H, Wang B, Liu Y, He X, Yu J, Yi H, He X. Accurate and fast reconstruction for bioluminescence tomography based on adaptive Newton hard thresholding pursuit algorithm. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:829-840. [PMID: 36215444 DOI: 10.1364/josaa.449917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 03/15/2022] [Indexed: 06/16/2023]
Abstract
As a promising noninvasive medical imaging technique, bioluminescence tomography (BLT) dynamically offers three-dimensional visualization of tumor distribution in living animals. However, due to the high ill-posedness caused by the strong scattering property of biological tissues and the limited boundary measurements with noise, BLT reconstruction still cannot meet actual preliminary clinical application requirements. In our research, to recover 3D tumor distribution quickly and precisely, an adaptive Newton hard thresholding pursuit (ANHTP) algorithm is proposed to improve the performance of BLT. The ANHTP algorithm fully combines the advantages of sparsity constrained optimization and convex optimization to guarantee global convergence. More precisely, an adaptive sparsity adjustment strategy was developed to obtain the support set of the inverse system matrix. Based on the strong Wolfe line search criterion, a modified damped Newton algorithm was constructed to obtain optimal source distribution information. A series of numerical simulations and phantom and in vivo experiments show that ANHTP has high reconstruction accuracy, fast reconstruction speed, and good robustness. Our proposed algorithm can further increase the practicality of BLT in biomedical applications.
Collapse
|
4
|
Zhang H, He X, Yu J, He X, Guo H, Hou Y. L1-L2 norm regularization via forward-backward splitting for fluorescence molecular tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:7807-7825. [PMID: 35003868 PMCID: PMC8713696 DOI: 10.1364/boe.435932] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 11/08/2021] [Accepted: 11/08/2021] [Indexed: 05/07/2023]
Abstract
Fluorescent molecular tomography (FMT) is a highly sensitive and noninvasive imaging approach for providing three-dimensional distribution of fluorescent marker probes. However, owing to its light scattering effect and the ill-posedness of inverse problems, it is challenging to develop an efficient reconstruction algorithm that can achieve the exact location and morphology of the fluorescence source. In this study, therefore, in order to satisfy the need for early tumor detection and improve the sparsity of solution, we proposed a novel L 1-L 2 norm regularization via the forward-backward splitting method for enhancing the FMT reconstruction accuracy and the robustness. By fully considering the highly coherent nature of the system matrix of FMT, it operates by splitting the objective to be minimized into simpler functions, which are dealt with individually to obtain a sparser solution. An analytic solution of L 1-L 2 norm proximal operators and a forward-backward splitting algorithm were employed to efficiently solve the nonconvex L 1-L 2 norm minimization problem. Numerical simulations and an in-vivo glioma mouse model experiment were conducted to evaluate the performance of our algorithm. The comparative results of these experiments demonstrated that the proposed algorithm obtained superior reconstruction performance in terms of spatial location, dual-source resolution, and in-vivo practicability. It was believed that this study would promote the preclinical and clinical applications of FMT in early tumor detection.
Collapse
Affiliation(s)
- Heng Zhang
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Xiaowei He
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Jingjing Yu
- School of Physics and Information Technology, Shaanxi Normal University, Xi'an, 710062, China
| | - Xuelei He
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Hongbo Guo
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| | - Yuqing Hou
- The Xi'an Key Laboratory of Radiomics and Intelligent Perception, Xi'an, China
- School of Information Sciences and Technology, Northwest University, Xi'an, 710127, China
| |
Collapse
|
5
|
Li S, He X, Zhang H, Guo H, He X. End-To-End Bioluminescence Tomography Reconstruction Based On Convolution Neural Network Scheme. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:3634-3639. [PMID: 34892025 DOI: 10.1109/embc46164.2021.9630437] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Bioluminescence tomography (BLT) has received a lot of attention as an important technique in bio-optical imaging. Compared with traditional methods, neural network methods have the advantages of fast reconstruction speed and support for batch processing. In this paper, we propose a end-to-end BLT reconstruction based on convolution neural networks scheme. First, 3000 datasets with single source and dual sources projection were conducted by Monte Carlo method, respectively. And three convolution neural networks (VGGNet, ResNet, and DenseNet) were adopted to feature extraction. Then, the filtered features were used as input to the multi-layer perceptron (MLP) to predict the source location. The results of numerical simulation and simulation experiments show, compared with traditional methods, the advantages of our method are including high reconstruction accuracy, faster reconstruction, few parameters, simple reconstruction process and support for batch processing.
Collapse
|
6
|
Zhang H, Guo H, Li S, Liu Y, He X, He X, Hou Y. L 1-L 2 Minimization Via A Proximal Operator For Fluorescence Molecular Tomography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:3640-3645. [PMID: 34892026 DOI: 10.1109/embc46164.2021.9630236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Fluorescent Molecular Tomography (FMT) is a highly sensitive and noninvasive imaging method that provides three-dimensional distribution of biomarkers by noninvasive detection of fluorescent marker probes. However, due to the light scattering effect and ill-posedness of inverse problems, it is challenging to develop an efficient construction method that can provide the exact location and morphology of the fluorescence distribution. In this paper, we proposed L1-L2 norm regularization to improve FMT reconstruction. In our research, proximal operators of non-convex L1 -L2 norm and forward-backward splitting method was adopted to solve the inverse problem of FMT. Simulation results on heterogeneous mouse model demonstrated that the proposed FBS method is superior to IVTCG, DCA and IRW-L1/2 reconstruction methods in location accuracy and other aspects.
Collapse
|