1
|
Cheng M, Li R, Du X, Zhang Z, Zhang H. Highly efficient removal of diclofenac sodium with polystyrene supported ionic liquid. ENVIRONMENTAL TECHNOLOGY 2024; 45:3276-3282. [PMID: 37184044 DOI: 10.1080/09593330.2023.2214856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 04/11/2023] [Indexed: 05/16/2023]
Abstract
ABSTRACTDiclofenac sodium (DS) is now recognized as an emerging pollutant, and is one of the most commonly discovered pharmaceuticals in water due to its extensive application in the clinic. This study examined the adsorption performance of a polystyrene-supported ionic liquid material (PS-[Nim][Cl]) for the removal of diclofenac sodium (DS) from water. The data from this study showed that maximum removal of DS can be achieved even in conditions with significant pH and temperature fluctuations. The adsorption process was rapid, more than 90% of DS could be removed within the first 10 min and adsorption equilibrium could be reached in just 30 min with a high removal efficiency (>99.9%). Adsorption reached saturation with a maximum adsorption capacity of approximately 785.2 mg/g. Moreover, the presence of K+, Na+, Ca2+, Mg2+, Cl-, and H2PO4- ions had little influence on DS adsorption, even when concentrations of these ions were 10,000 times higher than that of DS in water samples. The adsorbent also showed promising performance for the treatment of environmental water samples and groundwater containing DS.
Collapse
Affiliation(s)
- Meng Cheng
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of China
| | - Ruihua Li
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of China
| | - Xin Du
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of China
| | - Zihao Zhang
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of China
| | - Hao Zhang
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of China
| |
Collapse
|
2
|
Munir HMS, Feroze N, Ramzan N, Sagir M, Babar M, Tahir MS, Shamshad J, Mubashir M, Khoo KS. Fe-zeolite catalyst for ozonation of pulp and paper wastewater for sustainable water resources. CHEMOSPHERE 2022; 297:134031. [PMID: 35189191 DOI: 10.1016/j.chemosphere.2022.134031] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 02/08/2022] [Accepted: 02/15/2022] [Indexed: 06/14/2023]
Abstract
The pulp and paper industry consumes enormous quality of freshwater, leading to wastewater. It must be treated to remove pollutants, particularly residual dyestuffs, before releasing them to water bodies to avoid adverse environmental effects. The traditional wastewater treatment methods used for the pulp and paper industry are less efficient in colour and chemical oxygen demand (COD) removal. The current study is aimed at developing a novel catalyst for the catalytic ozonation of pulp and paper wastewater with better colour and COD removal for sustainable resources of clean water. The proposed catalyst is impregnated by iron on natural zeolites. Various parameters such as catalyst dose, pH, ozone dose, initial COD concentration, and reaction time are studied and optimized. The performance was evaluated by comparing the results with the single ozonation process (SOP) and catalytic ozonation process (COP). The highest COD and colour reduction efficiencies have been achieved, i.e., 71%, and 88% at a natural pH of 6.8. The proposed process achieved higher COD and colour efficiencies than the single ozonation process and catalytic ozonation process using raw zeolites. The improvement in efficiencies are 23% and 29% for SOP and 17% and 19% for COP, respectively. Hence, the results proposed the sustainability and applicability of COP to treat paper and pulp sector effluent.
Collapse
Affiliation(s)
- Hafiz Muhammad Shahzad Munir
- Department of Chemical Engineering, Khwaja Fareed University of Engineering and Information Technology (KFUEIT), Abu Dhabi Rd, Rahim Yar Khan, 64200, Pakistan; Chemical Engineering Department, University of Engineering and Technology, Lahore, 54890, Pakistan.
| | - Nadeem Feroze
- Chemical Engineering Department, University of Engineering and Technology, Lahore, 54890, Pakistan.
| | - Naveed Ramzan
- Chemical Engineering Department, University of Engineering and Technology, Lahore, 54890, Pakistan.
| | - Muhammad Sagir
- Department of Chemical Engineering, Khwaja Fareed University of Engineering and Information Technology (KFUEIT), Abu Dhabi Rd, Rahim Yar Khan, 64200, Pakistan; College of Earth and Environmental Sciences, University of the Punjab, Lahore, Pakistan.
| | - Muhammad Babar
- Department of Chemical Engineering, Khwaja Fareed University of Engineering and Information Technology (KFUEIT), Abu Dhabi Rd, Rahim Yar Khan, 64200, Pakistan.
| | - Muhammad Suleman Tahir
- Department of Chemical Engineering, Khwaja Fareed University of Engineering and Information Technology (KFUEIT), Abu Dhabi Rd, Rahim Yar Khan, 64200, Pakistan.
| | - Jaweria Shamshad
- College of Earth and Environmental Sciences, University of the Punjab, Lahore, Pakistan.
| | - Muhammad Mubashir
- Department of Petroleum Engineering, School of Engineering, Asia Pacific University of Technology and Innovation, 57000, Kuala Lumpur, Malaysia.
| | - Kuan Shiong Khoo
- Faculty of Applied Sciences, UCSI University, UCSI Heights, 56000, Cheras, Kuala Lumpur, Malaysia.
| |
Collapse
|
3
|
Prada-Vásquez MA, Estrada-Flórez SE, Serna-Galvis EA, Torres-Palma RA. Developments in the intensification of photo-Fenton and ozonation-based processes for the removal of contaminants of emerging concern in Ibero-American countries. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 765:142699. [PMID: 33071126 DOI: 10.1016/j.scitotenv.2020.142699] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/06/2020] [Accepted: 09/24/2020] [Indexed: 06/11/2023]
Abstract
Contaminants of emerging concern (CECs), such as pharmaceuticals, personal care products, pesticides, synthetic and natural hormones and industrial chemicals, are frequently released into the environment because of the inability of conventional processes in municipal wastewater treatment plants to remove them. Some examples of alternative options to remove such pollutants are photo-Fenton and ozone-based processes, which are two techniques widely studied in Ibero-American countries. In fact, this region has been responsible for delivering frequently publications and conferences on advanced oxidation processes. This work is a critical review of recent developments in the intensification of the two aforementioned advanced oxidation techniques for CECs elimination in the Ibero-American region. Specifically for the photo-Fenton process (pF), this study analyses strategies such as iron-complexation with artificial substances (e.g., oxalic acid and ethylenediamine-N,N'-disuccinic acid) and natural compounds (such as humic-like substances, orange juice or polyphenols) and hybrid processes with ultrasound. Meanwhile, for ozonation, the enhancement of CECs degradation by adding hydrogen peroxide (i.e., peroxone), ultraviolet or solar light, and combining (i.e., photolytic ozonation) with catalysts (i.e., catalytic ozonation) was reviewed. Special attention was paid to how efficient these techniques are for removing contaminants from water matrices, and any potentialities and weak points of the intensified processes.
Collapse
Affiliation(s)
- María A Prada-Vásquez
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia; Universidad Nacional de Colombia, Sede Medellín, Facultad de Minas, Departamento de Geociencias y Medioambiente, Colombia
| | - Sandra E Estrada-Flórez
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Efraím A Serna-Galvis
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
| | - Ricardo A Torres-Palma
- Grupo de Investigación en Remediación Ambiental y Biocatálisis (GIRAB), Instituto de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
| |
Collapse
|
4
|
Removal of Diclofenac in Effluent of Sewage Treatment Plant by Photocatalytic Oxidation. WATER 2020. [DOI: 10.3390/w12102902] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Diclofenac (DCF) has been widely found in sewage treatment plants and environmental water bodies, and has attracted worldwide attention. In this paper, the photocatalytic degradation of DCF was investigated using a laboratory-scale simulated solar experimental device. This study focused on exploring the effects of the actual secondary effluent from sewage treatment plants (SE-A and SE-B) on the photocatalytic degradation of DCF and the changes of dissolved organic matter (DOM) during the photocatalytic degradation process. The results showed when SE-A and SE-B were used as the background water of the DCF solution, they displayed a significant inhibitory effect on the degradation of DCF, and the values of k were 0.039 and 0.0113 min−1, respectively. Among them, DOM played a major inhibitory role in photocatalytic degradation of DCF in sewage. In the photocatalytic process, the biological toxicity of the DCF solution was the least after 30 min of reaction, and then gradually increased. Furthermore, the organic matters in the sewage were greatly degraded after the photocatalytic reaction, including 254 and 365 nm ultraviolet (UV254, UV365) and chemical oxygen demand (COD). Moreover, titanium dioxide (TiO2) first catalyzed the degradation of macromolecular organic matters, and then degraded the small molecular organic matters.
Collapse
|