1
|
Päeske L, Uudeberg T, Hinrikus H, Lass J, Bachmann M. Correlation between electroencephalographic markers in the healthy brain. Sci Rep 2023; 13:6307. [PMID: 37072499 PMCID: PMC10113388 DOI: 10.1038/s41598-023-33364-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 04/12/2023] [Indexed: 05/03/2023] Open
Abstract
Mental disorders have an increasing tendency and represent the main burden of disease to society today. A wide variety of electroencephalographic (EEG) markers have been successfully used to assess different symptoms of mental disorders. Different EEG markers have demonstrated similar classification accuracy, raising a question of their independence. The current study is aimed to investigate the hypotheses that different EEG markers reveal partly the same EEG features reflecting brain functioning and therefore provide overlapping information. The assessment of the correlations between EEG signal frequency band power, dynamics, and functional connectivity markers demonstrates that a statistically significant correlation is evident in 37 of 66 (56%) comparisons performed between 12 markers of different natures. A significant correlation between the majority of the markers supports the similarity of information in the markers. The results of the performed study confirm the hypotheses that different EEG markers reflect partly the same features in brain functioning. Higuchi's fractal dimension has demonstrated a significant correlation with the 82% of other markers and is suggested to reveal a wide spectrum of various brain disorders. This marker is preferable in the early detection of symptoms of mental disorders.
Collapse
Affiliation(s)
- Laura Päeske
- Department of Health Technologies, School of Information Technology, Tallinn University of Technology, 5 Ehitajate Rd, 19086, Tallinn, Estonia
| | - Tuuli Uudeberg
- Department of Health Technologies, School of Information Technology, Tallinn University of Technology, 5 Ehitajate Rd, 19086, Tallinn, Estonia
| | - Hiie Hinrikus
- Department of Health Technologies, School of Information Technology, Tallinn University of Technology, 5 Ehitajate Rd, 19086, Tallinn, Estonia.
| | - Jaanus Lass
- Department of Health Technologies, School of Information Technology, Tallinn University of Technology, 5 Ehitajate Rd, 19086, Tallinn, Estonia
| | - Maie Bachmann
- Department of Health Technologies, School of Information Technology, Tallinn University of Technology, 5 Ehitajate Rd, 19086, Tallinn, Estonia
| |
Collapse
|
2
|
Hinrikus H, Koppel T, Lass J, Orru H, Roosipuu P, Bachmann M. Possible health effects on the human brain by various generations of mobile telecommunication: a review based estimation of 5G impact. Int J Radiat Biol 2022; 98:1210-1221. [PMID: 34995145 DOI: 10.1080/09553002.2022.2026516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
PURPOSE The deployment of new 5G NR technology has significantly raised public concerns in possible negative effects on human health by radiofrequency electromagnetic fields (RF EMF). The current review is aimed to clarify the differences between possible health effects caused by the various generations of telecommunication technology, especially discussing and projecting possible health effects by 5G. The review of experimental studies on the human brain over the last fifteen years and the discussion on physical mechanisms and factors determining the dependence of the RF EMF effects on frequency and signal structure have been performed to discover and explain the possible distinctions between health effects by different telecommunication generations. CONCLUSIONS The human experimental studies on RF EMF effects on the human brain by 2G, 3G and 4G at frequencies from 450 to 2500 MHz were available for analyses. The search for publications indicated no human experimental studies by 5G nor at the RF EMF frequencies higher than 2500 MHz. The results of the current review demonstrate no consistent relationship between the character of RF EMF effects and parameters of exposure by different generations (2G, 3G, 4G) of telecommunication technology. At the RF EMF frequencies lower than 10 GHz, the impact of 5G NR FR1 should have no principal differences compared to the previous generations. The radio frequencies used in 5G are even higher and the penetration depths of the fields are smaller, therefore the effect is rather lower than at previous generations. At the RF EMF frequencies higher than 10 GHz, the mechanism of the effects might differ and the impact of 5G NR FR2 becomes unpredictable. Existing knowledge about the mechanism of RF EMF effects at millimeter waves lacks sufficient experimental data and theoretical models for reliable conclusions. The insufficient knowledge about the possible health effects at millimeter waves and the lack of in vivo experimental studies on 5G NR underline an urgent need for the theoretical and experimental investigations of health effects by 5G NR, especially by 5G NR FR2.
Collapse
Affiliation(s)
- Hiie Hinrikus
- Department of Health Technologies, School of Information Technologies, Tallinn University of Technology, Tallinn, Estonia
| | - Tarmo Koppel
- Department of Business Administration, School of Business and Governance, Tallinn University of Technology, Tallinn, Estonia
| | - Jaanus Lass
- Department of Health Technologies, School of Information Technologies, Tallinn University of Technology, Tallinn, Estonia
| | - Hans Orru
- Department of Public Health, Institute of Family Medicine and Public Health, Faculty of Medicine, University of Tartu, Tartu, Estonia
| | - Priit Roosipuu
- Thomas Johann Seebeck Department of Electronics, School of Information Technologies, Tallinn University of Technology, Tallinn, Estonia
| | - Maie Bachmann
- Department of Health Technologies, School of Information Technologies, Tallinn University of Technology, Tallinn, Estonia
| |
Collapse
|
3
|
Hinrikus H, Lass J, Bachmann M. Threshold of radiofrequency electromagnetic field effect on human brain. Int J Radiat Biol 2021; 97:1505-1515. [PMID: 34402382 DOI: 10.1080/09553002.2021.1969055] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
PURPOSE This review aims to estimate the threshold of radiofrequency electromagnetic field (RF EMF) effects on human brain based on analyses of published research results. To clarify the threshold of the RF EMF effects, two approaches have been applied: (1) the analyses of restrictions in sensitivity for different steps of the physical model of low-level RF EMF mechanism and (2) the analyses of experimental data to clarify the dependence of the RF EMF effect on exposure level based on the results of published original neurophysiological and behavioral human studies for 15 years 2007-2021. CONCLUSIONS The analyses of the physical model of nonthermal mechanisms of RF EMF effect leads to conclusion that no principal threshold of the effect can be determined. According to the review of experimental data, the rate of detected RF EMF effects is 76.7% in resting EEG studies, 41.7% in sleep EEG and 38.5% in behavioral studies. The changes in EEG probably appear earlier than alterations in behavior become evident. The lowest level of RF EMF at which the effect in EEG was detected is 2.45 V/m (SAR = 0.003 W/kg). There is a preliminary indication that the dependence of the effect on the level of exposure follows rather field strength than SAR alterations. However, no sufficient data are available for clarifying linearity-nonlinearity of the dependence of effect on the level of RF EMF. The finding that only part of people are sensitive to RF EMF exposure can be related to immunity to radiation or hypersensitivity. The changes in EEG caused by RF EMF appeared similar in the majority of analyzed studies and similar to these in depression. The possible causal relationship between RF EMF effect and depression among young people is highly important problem.
Collapse
Affiliation(s)
| | - Jaanus Lass
- Tallinn University of Technology, Tallinn, Estonia
| | | |
Collapse
|
4
|
Bachmann M, Päeske L, Kalev K, Aarma K, Lehtmets A, Ööpik P, Lass J, Hinrikus H. Methods for classifying depression in single channel EEG using linear and nonlinear signal analysis. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 155:11-17. [PMID: 29512491 DOI: 10.1016/j.cmpb.2017.11.023] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 11/14/2017] [Accepted: 11/24/2017] [Indexed: 05/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Depressive disorder is one of the leading causes of burden of disease today and it is presumed to take the first place in the world in 2030. Early detection of depression requires a patient-friendly inexpensive method based on easily measurable objective indicators. This study aims to compare various single-channel electroencephalographic (EEG) measures in application for detection of depression. METHODS The EEG recordings were performed on a group of 13 medication-free depressive outpatients and 13 gender and age matched controls. The recorded 30-channel EEG signal was analysed using linear methods spectral asymmetry index, alpha power variability and relative gamma power and nonlinear methods Higuchi's fractal dimension, detrended fluctuation analysis and Lempel-Ziv complexity. Classification accuracy between depressive and control subjects was calculated using logistic regression analysis with leave-one-out cross-validation. Calculations were performed separately for each EEG channel. RESULTS All calculated measures indicated increase with depression. Maximal testing accuracy using a single measure was 81% for linear and 77% for nonlinear measures. Combination of two linear measures provides the accuracy of 88% and two nonlinear measures of 85%. Maximal classification accuracy of 92% was indicated using mixed combination of three linear and three nonlinear measures. CONCLUSIONS The results of this preliminary study confirm that single-channel EEG analysis, employing the combination of measures, can provide discrimination of depression at the level of multichannel EEG analysis. The performed study shows that there is no single superior measure for detection of depression.
Collapse
Affiliation(s)
- Maie Bachmann
- Centre for Biomedical Engineering, Department of Health Technologies, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086, Estonia.
| | - Laura Päeske
- Centre for Biomedical Engineering, Department of Health Technologies, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086, Estonia
| | - Kaia Kalev
- Centre for Biomedical Engineering, Department of Health Technologies, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086, Estonia
| | - Katrin Aarma
- Centre for Biomedical Engineering, Department of Health Technologies, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086, Estonia
| | - Andres Lehtmets
- Psychiatric Centre, West Tallinn Central Hospital, Paldiski mnt 68, Tallinn 10617, Estonia
| | - Pille Ööpik
- Ädala Family Medicine Center, Madara tn 29, Tallinn 10612, Estonia; Department of Family Medicine, University of Tartu, Ülikooli 18, Tartu 50090, Estonia
| | - Jaanus Lass
- Centre for Biomedical Engineering, Department of Health Technologies, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086, Estonia
| | - Hiie Hinrikus
- Centre for Biomedical Engineering, Department of Health Technologies, Tallinn University of Technology, Ehitajate tee 5, Tallinn 19086, Estonia
| |
Collapse
|
5
|
Advantages and problems of nonlinear methods applied to analyze physiological time signals: human balance control as an example. Sci Rep 2017; 7:2464. [PMID: 28550294 PMCID: PMC5446424 DOI: 10.1038/s41598-017-02665-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 04/12/2017] [Indexed: 11/23/2022] Open
Abstract
Physiological processes are regulated by nonlinear dynamical systems. Various nonlinear measures have frequently been used for characterizing the complexity of fractal time signals to detect system features that cannot be derived from linear analyses. We analysed human balance dynamics ranging from simple standing to balancing on one foot with closed eyes to study the inherent methodological problems when applying fractal dimension analysis to real-world signals. Higuchi dimension was used as an example. Choice of measurement and analysis parameters has a distinct influence on the computed dimension. Noise increases the fractional dimension which may be misinterpreted as a higher complexity of the signal. Publications without specifying the parameter setting, or without analysing the noise-sensitivity are not comparable to findings of others and therefore of limited scientific value.
Collapse
|
6
|
Kesić S, Spasić SZ. Application of Higuchi's fractal dimension from basic to clinical neurophysiology: A review. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2016; 133:55-70. [PMID: 27393800 DOI: 10.1016/j.cmpb.2016.05.014] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Revised: 03/24/2016] [Accepted: 05/27/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND AND OBJECTIVE For more than 20 years, Higuchi's fractal dimension (HFD), as a nonlinear method, has occupied an important place in the analysis of biological signals. The use of HFD has evolved from EEG and single neuron activity analysis to the most recent application in automated assessments of different clinical conditions. Our objective is to provide an updated review of the HFD method applied in basic and clinical neurophysiological research. METHODS This article summarizes and critically reviews a broad literature and major findings concerning the applications of HFD for measuring the complexity of neuronal activity during different neurophysiological conditions. The source of information used in this review comes from the PubMed, Scopus, Google Scholar and IEEE Xplore Digital Library databases. RESULTS The review process substantiated the significance, advantages and shortcomings of HFD application within all key areas of basic and clinical neurophysiology. Therefore, the paper discusses HFD application alone, combined with other linear or nonlinear measures, or as a part of automated methods for analyzing neurophysiological signals. CONCLUSIONS The speed, accuracy and cost of applying the HFD method for research and medical diagnosis make it stand out from the widely used linear methods. However, only a combination of HFD with other nonlinear methods ensures reliable and accurate analysis of a wide range of neurophysiological signals.
Collapse
Affiliation(s)
- Srdjan Kesić
- University of Belgrade, Institute for Biological Research "Siniša Stanković", Department of Neurophysiology, Bulevar Despota Stefana 142, 11060 Belgrade, Serbia
| | - Sladjana Z Spasić
- University of Belgrade, Institute for Multidisciplinary Research, Department of Life Sciences, Kneza Višeslava 1, 11030 Belgrade, Serbia; Singidunum University, Danijelova 32, 11010 Belgrade, Serbia.
| |
Collapse
|
7
|
Ahammer H, Sabathiel N, Reiss MA. Is a two-dimensional generalization of the Higuchi algorithm really necessary? CHAOS (WOODBURY, N.Y.) 2015; 25:073104. [PMID: 26232955 DOI: 10.1063/1.4923030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Fractal dimensions of data series, particularly time series can be estimated very well by using Higuchi's algorithm. Without phase space constructions, the fractal dimension of a one-dimensional data stream is calculated. Higuchi's method is well accepted and widely applied, because it is very reliable and easy to implement. A generalization of the genuine 1D algorithm to two dimensions would be desirable in order to investigate digital images. In this study, we propose several 2D generalization algorithms and evaluate differences between them. Additionally, a comparison to previously published pseudo 2D generalizations, and to the Fourier and the Blanket method are presented. The algorithms were tested on artificially generated grey value and red-green-blue colour images. It turned out that the proposed 2D generalized Higuchi algorithms are very robust, but differences in between the generalizations as well as differences to the pseudo 2D algorithms are astonishingly small.
Collapse
Affiliation(s)
- Helmut Ahammer
- Institute of Biophysics, Centre of Physiological Medicine, Medical University of Graz, Graz A-8010, Austria
| | - Nikolaus Sabathiel
- Institute of Biophysics, Centre of Physiological Medicine, Medical University of Graz, Graz A-8010, Austria
| | - Martin A Reiss
- Institute of Biophysics, Centre of Physiological Medicine, Medical University of Graz, Graz A-8010, Austria
| |
Collapse
|
8
|
Spectral asymmetry and Higuchi's fractal dimension measures of depression electroencephalogram. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013. [PMID: 24232245 DOI: 10.1155/2013/251638.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This study was aimed to compare two electroencephalogram (EEG) analysis methods, spectral asymmetry index (SASI) and Higuchi's fractal dimension (HFD), for detection of depression. Linear SASI method is based on evaluation of the balance of powers in two EEG frequency bands in one channel selected higher and lower than the alpha band spectrum maximum. Nonlinear HFD method calculates fractal dimension directly in the time domain. The resting EEG signals of 17 depressive patients and 17 control subjects were used as a database for calculations. SASI values were positive for depressive and negative for control group (P < 0.05). SASI provided the true detection rate of 88% in the depressive and 82% in the control group. The calculated HFD values detected a small (3%) increase with depression (P < 0.05). HFD provided the true detection rate of 94% in the depressive group and 76% in the control group. The rate of correct indication in the both groups was 85% using SASI or HFD. Statistically significant variations were not revealed between hemispheres (P > 0.05). The results indicated that the linear EEG analysis method SASI and the nonlinear HFD method both demonstrated a good sensitivity for detection of characteristic features of depression in a single-channel EEG.
Collapse
|
9
|
Spectral asymmetry and Higuchi's fractal dimension measures of depression electroencephalogram. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013; 2013:251638. [PMID: 24232245 PMCID: PMC3819823 DOI: 10.1155/2013/251638] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2013] [Revised: 09/05/2013] [Accepted: 09/06/2013] [Indexed: 12/15/2022]
Abstract
This study was aimed to compare two electroencephalogram (EEG) analysis methods, spectral asymmetry index (SASI) and Higuchi's fractal dimension (HFD), for detection of depression. Linear SASI method is based on evaluation of the balance of powers in two EEG frequency bands in one channel selected higher and lower than the alpha band spectrum maximum. Nonlinear HFD method calculates fractal dimension directly in the time domain. The resting EEG signals of 17 depressive patients and 17 control subjects were used as a database for calculations. SASI values were positive for depressive and negative for control group (P < 0.05). SASI provided the true detection rate of 88% in the depressive and 82% in the control group. The calculated HFD values detected a small (3%) increase with depression (P < 0.05). HFD provided the true detection rate of 94% in the depressive group and 76% in the control group. The rate of correct indication in the both groups was 85% using SASI or HFD. Statistically significant variations were not revealed between hemispheres (P > 0.05). The results indicated that the linear EEG analysis method SASI and the nonlinear HFD method both demonstrated a good sensitivity for detection of characteristic features of depression in a single-channel EEG.
Collapse
|
10
|
A New Approach to Detect Epileptic Seizures in Electroencephalograms Using Teager Energy. ACTA ACUST UNITED AC 2013. [DOI: 10.1155/2013/358108] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A Teager energy (TE) based approach to discriminate electroencephalogram signals corresponding to nonseizure (eyes open, eyes closed, or interictal) and seizure (ictal) intervals is proposed. Though a good number of contributions have been made for seizure detection, the challenges of unbalanced data (nonseizure and seizure events) and system computational efficiency still remain a challenge. It is reported in the literature that the seizures are characterized by abnormal sudden discharges in the brain which get manifested in the EEG recordings by frequency changes and increased amplitudes. Teager energy (TE) is capable of tracking such rapid changes in frequency as well as amplitude in the time domain. An important finding of this study is that the mean TE quantifier is largely independent of the window length and exhibits relative consistency when used as a relative measure for comparison. We compared the diagnostic capability of TE quantifier with those of Higuchi’s fractal dimension and sample entropy in discriminating nonseizure and seizure states in the EEGs and found that TE outperforms the other two nonlinear quantifiers. The result shows that the application of this method compares favorably with conventional classification methods in terms of performance and is well suited for real-time automatic epileptic seizure detection.
Collapse
|
11
|
Supek S, Magjarevic R. Neurodynamic measures of functional connectivity and cognition. Med Biol Eng Comput 2011; 49:507-9. [PMID: 21512843 DOI: 10.1007/s11517-011-0779-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2011] [Accepted: 04/07/2011] [Indexed: 10/18/2022]
|