1
|
Yazdanpanah-Ardakani K, Niroomand-Oscuii H, Sahebi-Kuzeh Kanan R, Shokri N. Optimization of a centrifugal blood pump designed using an industrial method through experimental and numerical study. Sci Rep 2024; 14:7443. [PMID: 38548818 DOI: 10.1038/s41598-024-57019-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 03/13/2024] [Indexed: 04/02/2024] Open
Abstract
With improved treatment of coronary artery disease, more patients are surviving until heart failure occurs. This leads to an increase in patients needing devices for struggling with heart failure. Ventricular assist devices are known as the mainstay of these devices. This study aimed to design a centrifugal pump as a ventricular assist device. In order to design the pump, firstly, the geometrical parameters of the pump, including the gap distance, blade height, and position of the outlet relative to the blade, were investigated. Finally, the selected configuration, which had all the appropriate characteristics, both hydraulically and physiologically, was used for the rest of the study. The study of the blade, as the main component in energy transfer to the blood, in a centrifugal pump, has been considered in the present study. In this regard, the point-to-point design method, which is used in industrial applications, was implemented. The designer chooses the relationship between the blade angles at each radius in the point-to-point method. The present study selected logarithmic and second-order relations for designing the blade's profile. In total, 58 blades were examined in this study, which differed regarding blade inlet and outlet angles and the relationship between angle and radial position. ANSYS CFX 17.0 software was utilized to simulate blades' performances, and a benchmark pump provided by the US Food and Drug Administration (FDA) was used to validate the numerical simulations. Then, the selected impeller from the numerical investigation was manufactured, and its performance was compared experimentally with the FDA benchmark pump. A hydraulic test rig was also developed for experimental studies. The results showed that among the blades designed in this study, the blade with an input angle of 45° and an output angle of 55°, which is designed to implement a logarithmic relationship, has the best performance. The selected impeller configuration can increase the total head (at least by 20%) at different flow rates compared to the FDA pump.
Collapse
Affiliation(s)
| | | | | | - Nasim Shokri
- Department of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran
| |
Collapse
|
2
|
Huo M, Giridharan GA, Sethu P, Qu P, Qin K, Wang Y. Numerical simulation analysis of multi-scale computational fluid dynamics on hemodynamic parameters modulated by pulsatile working modes for the centrifugal and axial left ventricular assist devices. Comput Biol Med 2024; 169:107788. [PMID: 38091724 DOI: 10.1016/j.compbiomed.2023.107788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 11/08/2023] [Accepted: 11/28/2023] [Indexed: 02/08/2024]
Abstract
Continuous flow (CF) left ventricular assist devices (LVAD) operate at a constant speed mode, which could result in increased risk of adverse events due to reduced vascular pulsatility. Consequently, pump speed modulation algorithms have been proposed to augment vascular pulsatility. However, the quantitative local hemodynamic effects on the aorta when the pump is operating with speed modulation using different types of CF-LVADs are still under investigation. The computational fluid dynamics (CFD) study was conducted to quantitatively elucidate the hemodynamic effects on a clinical patient-specific aortic model under different speed patterns of CF-LVADs. Pressure distribution, wall shear stress (WSS), time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and velocity were calculated to compare their differences at constant and pulsatile speeds under centrifugal and axial LVAD support. Results showed that pulse pressure on the aorta was significantly larger under pulsatile speed mode than that under constant speed mode for both CF-LVADs, indicating enhanced aorta pulsatility, as well as the higher peak blood flow velocity on some representative slices of aorta. Pulsatile speed modulation enhanced peak WSS compared to constant speed; high TAWSS region appeared near the branch of left common carotid artery and distal aorta regardless of speed modes and CF-LVADs but these regions also had low OSI; RRT was almost the same for all the cases. This study may provide a basis for the scientific and reasonable selection of the pulsatile speed patterns of CF-LVADs for treating heart failure patients.
Collapse
Affiliation(s)
- Mingming Huo
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | | | - Palaniappan Sethu
- Division of Cardiovascular Disease, Department of Medicine, School of Medicine and Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Peng Qu
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China
| | - Kairong Qin
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China
| | - Yu Wang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, China.
| |
Collapse
|
3
|
Oran E, Abo-Serie E, Jewkes J, Henry M, Oran B. Design and optimisation of an Intra-Aortic Shrouded rotor axial pump. J Biomech 2024; 162:111858. [PMID: 37989028 DOI: 10.1016/j.jbiomech.2023.111858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 10/27/2023] [Accepted: 11/01/2023] [Indexed: 11/23/2023]
Abstract
Undesirable side effects in patients with a LVAD (Left Ventricular Assist Device) pump fitted include blood damage, thrombosis, blood traumatisation, and End-Organ Disfunctions. These side effects have generally been attributed to the high wall shear stresses and the induced turbulent flow. In this study, we introduce a novel design to address these effects by lowering the rotational speed and providing an optimum flow path design to minimise blood damage. We present an initial scheme for a new Intra-Aortic Shrouded Rotary Axial Pump and develop a sequence of pump geometries, for which the Taguchi Design Optimisation Method has been applied. We apply CFD tools to simulate the pressure rise, pump performance, hydraulic efficiency, wall shear stress, exposure time and mass flow rate. A prototype pump has been tested in a mock cardiovascular circuit using a water-glycerol solution. The optimum design delivered the desired pressure/mass flow rate characteristics at a significantly low rpm (2900 rpm). As a result, the estimated blood damage index is low, matching the design requirements. The theoretical performance was matched by experimental results.
Collapse
Affiliation(s)
- Elif Oran
- Coventry University, Centre for Fluid and Complex Systems, Coventry, UK
| | - Essam Abo-Serie
- University of Leicester, School of Engineering, Leicester, UK.
| | - James Jewkes
- University of Leicester, School of Engineering, Leicester, UK
| | - Manus Henry
- Coventry University, Centre for Fluid and Complex Systems, Coventry, UK; University of Oxford, Department of Engineering Science, Oxford, UK
| | - Bulent Oran
- Medicana International Hospital, Department of Pediatric Cardiology, Izmir, Turkey
| |
Collapse
|
4
|
Zhang Y, Wu X, Wang Y, Liu H, Liu GM. The hemodynamics and blood trauma in axial blood pump under different operating model. Artif Organs 2022; 46:2159-2170. [PMID: 35735995 DOI: 10.1111/aor.14348] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 05/11/2022] [Accepted: 06/06/2022] [Indexed: 11/29/2022]
Abstract
Speed modulation of blood pump has been proved to help restore vascular pulsatility and implemented clinically during treatment for cardiac failure. However, its effect on blood trauma has not been studied thoroughly. In this paper, we study the flow field of an axial pump FW-X under the modes of co-pulse, counter pulse and constant speed to evaluate the blood trauma. Based on the coupling model of cardiovascular system and axial blood pump, aortic pressure and the pump flow were obtained and applied as the boundary conditions at the pump outlet and inlet. The level of shear stress and hemolysis index were derived from computational fluid dynamics (CFD) simulation. Results showed the constant speed mode had the lowest shear stress level and hemolytic index at the expense of diminished pulsatility. Compared with the constant speed mode, the hemolysis index of co-pulse and counter pulse mode was higher, but it was helpful to restore vascular pulsatility. This method can be easily incorporated in the in vitro testing phase to analyze and decrease a pump's trauma before animal experimentation, thereby reducing the cost of blood pump development.
Collapse
Affiliation(s)
- Yunpeng Zhang
- School of Electrical Engineering, Shandong University, Jinan, China
| | - Xiangyu Wu
- School of Electrical Engineering, Shandong University, Jinan, China
| | - Yiming Wang
- School of Electrical Engineering, Shandong University, Jinan, China
| | - Hongtao Liu
- School of Goertek Technology and Industry, Weifang University, Weifang, China
| | - Guang-Mao Liu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
5
|
Ozturk C, Rosalia L, Roche ET. A Multi-Domain Simulation Study of a Pulsatile-Flow Pump Device for Heart Failure With Preserved Ejection Fraction. Front Physiol 2022; 13:815787. [PMID: 35145432 PMCID: PMC8822361 DOI: 10.3389/fphys.2022.815787] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 01/05/2022] [Indexed: 12/02/2022] Open
Abstract
Mechanical circulatory support (MCS) devices are currently under development to improve the physiology and hemodynamics of patients with heart failure with preserved ejection fraction (HFpEF). Most of these devices, however, are designed to provide continuous-flow support. While it has been shown that pulsatile support may overcome some of the complications hindering the clinical translation of these devices for other heart failure phenotypes, the effects that it may have on the HFpEF physiology are still unknown. Here, we present a multi-domain simulation study of a pulsatile pump device with left atrial cannulation for HFpEF that aims to alleviate left atrial pressure, commonly elevated in HFpEF. We leverage lumped-parameter modeling to optimize the design of the pulsatile pump, computational fluid dynamic simulations to characterize hydraulic and hemolytic performance, and finite element modeling on the Living Heart Model to evaluate effects on arterial, left atrial, and left ventricular hemodynamics and biomechanics. The findings reported in this study suggest that pulsatile-flow support can successfully reduce pressures and associated wall stresses in the left heart, while yielding more physiologic arterial hemodynamics compared to continuous-flow support. This work therefore supports further development and evaluation of pulsatile support MCS devices for HFpEF.
Collapse
Affiliation(s)
- Caglar Ozturk
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Luca Rosalia
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States
- Health Sciences and Technology Program, Harvard – Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Ellen T. Roche
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States
- *Correspondence: Ellen T. Roche,
| |
Collapse
|
6
|
YAZDANPANH-ARDAKANI KOHYAR, NIROOMAND-OSCUII HANIEH. COMPUTATIONAL STUDY ON THE PERFORMANCE OF A CENTRIFUGAL LVAD WITH THE IMPELLER DESIGNED BY INDUSTRIAL METHOD: PROPOSING SIMPLE-TO-MANUFACTURE LVAD’S IMPELLERS. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421500111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Although the demand of donor hearts for patients with end-stage heart failure is growing, its supply has remained constant. Ventricular assist devices (VADs) provide a chance of finding donor heart by increasing waiting period. In this study, the main goal is to employ an industrial method (point-by-point method) for designing blades profile with a simplified geometry which can be produced by conventional manufacturing methods. In this study, a centrifugal continuous-flow rotary pump is designed and the effects of components’ different geometries on the left ventricular assist devices (LVADs) function are investigated. Moreover, both hydraulic performance and blood damages (hemolysis index (HI)) caused by the pump are considered as design criteria. ANSYS CFX 17 is used to analyze the performance of the designed LVAD. Additionally, the geometry of components are investigated based on fulfilling the required performance of the LVAD while reducing the blood damage level. Comparing the designed VAD with the commercial ones shows that the designed blade further improves the performance of the centrifugal LVAD. Therefore, designing the impeller’s blade profile with point-by-point method seems to be promising. Simplicity in manufacturing is considered to be a big advantage for a design which also leads to lower manufacturing costs. This study demonstrates how industrial design methods can be employed to design simple-to-manufacture impellers which are suitable for LVADs.
Collapse
|
7
|
Attaran SH, Niroomand-Oscuii H, Ghalichi F. Local hemodynamic analysis of the C-Pulse Device by 3D fluid-structure interaction simulation. Future Cardiol 2020; 16:297-308. [PMID: 32228240 DOI: 10.2217/fca-2019-0004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Background: C-Pulse is a new, nonblood contacting device based on the concept of counter-pulsation that is designed for long-term implantation. However, there is a lack of comprehensive investigation of the pressure and velocity fields under the action of C-Pulse. Aim: In this paper, we aim to conduct a numerical simulation of the underlying mechanism of the device in order to analyze its performance and related undesirable issues. Materials & methods: A 3D finite element model is utilized to simulate the mechanism of the blood pumping. Results & conclusion: The simulation well reproduced the essential characteristics of the C-Pulse. Preliminary results were in a reasonable range while a couple of irregular flow patterns were identified.
Collapse
Affiliation(s)
| | | | - Farzan Ghalichi
- Department of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran
| |
Collapse
|
8
|
Proposal of hemodynamically improved design of an axial flow blood pump for LVAD. Med Biol Eng Comput 2019; 58:401-418. [DOI: 10.1007/s11517-019-02097-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 12/10/2019] [Indexed: 11/27/2022]
|
9
|
Influence of Impeller Speed Patterns on Hemodynamic Characteristics and Hemolysis of the Blood Pump. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9214689] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A continuous-flow output mode of a rotary blood pump reduces the fluctuation range of arterial blood pressure and easily causes complications. For a centrifugal rotary blood pump, sinusoidal and pulsatile speed patterns are designed using the impeller speed modulation. This study aimed to analyze the hemodynamic characteristics and hemolysis of different speed patterns of a blood pump in patients with heart failure using computational fluid dynamics (CFD) and the lumped parameter model (LPM). The results showed that the impeller with three speed patterns (including the constant speed pattern) met the normal blood demand of the human body. The pulsating flow generated by the impeller speed modulation effectively increased the maximum pulse pressure (PP) to 12.7 mm Hg, but the hemolysis index (HI) in the sinusoidal and pulsatile speed patterns was higher than that in the constant speed pattern, which was about 2.1 × 10−5. The flow path of the pulsating flow field in the spiral groove of the hydrodynamic suspension bearing was uniform, but the alternating high shear stress (0~157 Pa) was caused by the impeller speed modulation, causing blood damage. Therefore, the rational modulation of the impeller speed and the structural optimization of a blood pump are important for improving hydrodynamic characteristics and hemolysis.
Collapse
|
10
|
WU XIAO, ZHANG XIWEN, HAO PENGFEI, HE FENG. COMPARISON OF THREE CONTROL STRATEGIES FOR AXIAL BLOOD PUMP. J MECH MED BIOL 2019. [DOI: 10.1142/s0219519419500581] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Facing the gradually increased prevalence of heart failure (HF) and the shortage of donated hearts, the blood pump is widely used to prolong the life of end-stage HF patients: however, the pump generates continuous flow under constant rotational speed, declining the arterial pulsatility and causing related complications. Previous studies show that synchronous copulsation might be the best control strategy for restoring pulsatility, but synchronous strategies are needed to monitor the phase of the heartbeat, which will make the controller complex and impair its robustness. Here, we compare constant speed, synchronous copulsation in a model of a cardiovascular system with a blood pump, which shows that copulsation offers more arterial pulsatility, less pump power-consumption, and thus better battery endurance, and constant speed offers a greater ventricular unloading effect. Meanwhile, we design a strategy based on transforming left ventricular pressure, which is easier to implement and has similar effect to synchronous copulsation.
Collapse
Affiliation(s)
- XIAO WU
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - XIWEN ZHANG
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - PENGFEI HAO
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| | - FENG HE
- School of Aerospace Engineering, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
11
|
Chen Z, Jena SK, Giridharan GA, Sobieski MA, Koenig SC, Slaughter MS, Griffith BP, Wu ZJ. Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD. Med Biol Eng Comput 2018; 57:807-818. [PMID: 30406881 DOI: 10.1007/s11517-018-1922-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 10/24/2018] [Indexed: 11/30/2022]
Abstract
Modulation of pump speed has been proposed and implemented clinically to improve vascular pulsatility in continuous flow ventricular assist device patient. The flow dynamics of the HVAD with a promising asynchronous pump speed modulation and its potential risk for device-induced blood trauma was investigated numerically. The boundary conditions at the pump inlet and outlet were defined using the pressure waveforms adapted from the experimentally recorded ventricular and arterial pressure waveforms in a large animal ischemic heart failure (IHF) model supported by the HVAD operated at constant and modulated pump speeds. Shear stress fields and hemolysis indices were derived from the simulated flow fields. The overall features of the computationally generated flow waveforms at simulated constant and pulse-modulated speed operations matched with those of the experimentally recorded flow waveforms. The simulations showed that the shear stress field and hemolysis index vary throughout the cardiac cycle under the constant speed operation, and also as a function of modulation profile under modulated speed operation. The computational model did not demonstrate any differences in the time average hemolysis index between constant and modulated pump speed operations, thereby predicting pulse-modulated speed operation may help to restore vascular pulsatility without any further increased risk of blood trauma. Graphical abstract The streamline inside the HVAD pump and the wall shear stress distribution on the impeller surface at six discrete time instants over one cardiac cycle under constant speed operation (3000 rpm) (a) and under pulse-modulated speed operation (b). c Computationally predicted flow rate waveform under pulse-modulated speed operation. d Computationally predicted time-varying HI generated by the HVAD pump under the two operation modes constant speed (dash line) and pulse-modulated speed (solid line). These figures indicate that the pulse-modulated speed operation may help to restore vascular pulsatility without any further increased risk of blood trauma.
Collapse
Affiliation(s)
- Zengsheng Chen
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 434A, Baltimore, MD, 21201, USA
| | - Sofen K Jena
- Department of Cardiovascular and Thoracic Surgery, University of Louisville School of Medicine, Louisville, KY, 40202, USA
| | - Guruprasad A Giridharan
- Department of Cardiovascular and Thoracic Surgery, University of Louisville School of Medicine, Louisville, KY, 40202, USA.,Department of Bioengineering, Speed School of Engineering, University of Louisville, Louisville, KY, 40292, USA
| | - Michael A Sobieski
- Department of Cardiovascular and Thoracic Surgery, University of Louisville School of Medicine, Louisville, KY, 40202, USA
| | - Steven C Koenig
- Department of Cardiovascular and Thoracic Surgery, University of Louisville School of Medicine, Louisville, KY, 40202, USA.,Department of Bioengineering, Speed School of Engineering, University of Louisville, Louisville, KY, 40292, USA
| | - Mark S Slaughter
- Department of Cardiovascular and Thoracic Surgery, University of Louisville School of Medicine, Louisville, KY, 40202, USA
| | - Bartley P Griffith
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 434A, Baltimore, MD, 21201, USA
| | - Zhongjun J Wu
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, 10 South Pine Street, MSTF 434A, Baltimore, MD, 21201, USA. .,Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD, 20742, USA.
| |
Collapse
|