1
|
Mason K, Iball G, Hinchcliffe D, Snaith B. A systematic review comparing the effective radiation dose of musculoskeletal cone beam computed tomography to other diagnostic imaging modalities. Eur J Radiol 2024; 177:111558. [PMID: 38964225 DOI: 10.1016/j.ejrad.2024.111558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 04/05/2024] [Accepted: 06/07/2024] [Indexed: 07/06/2024]
Abstract
PURPOSE Cone-Beam CT (CBCT) is well established in orofacial diagnostic imaging and is currently expanding into musculoskeletal applications. This systematic review sought to update the knowledge base on radiation dose comparisons between imaging modalities in MSK imaging and consider how research studies have reported dose measures. METHODS This review utilised a database search and an online literature tool. Studies with potential relevance were screened then before full text review, each performed by two independent reviewers, with a third independent reviewer available for conflicts. Data was extracted using a bespoke tool created within the literature tool. RESULTS 21 studies were included in the review which compared CBCT with MSCT (13), conventional radiography (1), or both (7). 19 studies concluded that CBCT provided a reduced radiation dose when compared with MSCT: the factor of reduction ranging from 1.71 to 50 with an average of 12. Studies comparing CBCT to DR found DR to have an average dose reduction of 4.55. CONCLUSIONS The claims that CBCT produces a lower radiation dose than MSCT is borne out with most studies confirming doses less than half that of MSCT. Fewer studies include DR as a comparator but confirm that CBCT results in a higher effective dose on average, with scope for CBCT to provide an equivalent radiation dose. This review highlighted a need for consistency in methodology when conducting studies which compare radiation dose across different technologies. Potential solutions lie outside the scope of this review, likely requiring multi-discipline approach to ensure a cohesive outcome.
Collapse
Affiliation(s)
- K Mason
- Mid Yorkshire Teaching Hospitals NHS Trust, Aberford Rd, Wakefield, WY WF1 4DG, UK.
| | - G Iball
- University of Bradford, Bradford, WY BD7 1DB, UK.
| | - D Hinchcliffe
- Mid Yorkshire Teaching Hospitals NHS Trust, Aberford Rd, Wakefield, WY WF1 4DG, UK
| | - B Snaith
- Mid Yorkshire Teaching Hospitals NHS Trust, Aberford Rd, Wakefield, WY WF1 4DG, UK; University of Bradford, Bradford, WY BD7 1DB, UK
| |
Collapse
|
2
|
Sani G, Giabbani N, Zanna L, Buzzi R, Pio AS, Rastrelli V, Nardi C. The impact of sustentaculum tali fracture on clinical outcome in patients affected by isolated calcaneal fractures. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1017-1024. [PMID: 37855937 PMCID: PMC10858157 DOI: 10.1007/s00590-023-03760-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 10/02/2023] [Indexed: 10/20/2023]
Abstract
INTRODUCTION The sustentaculum tali is displaced in almost half of calcaneal fractures and during surgical fixation represents one of the main reference points upon which the other bone has to be reduced. The purpose of this study was to investigate which subtalar joint fracture pattern is more frequently associated with sustentaculum tali involvement. Furthermore, correlation between postoperative clinical outcome and sustentaculum tali integrity was performed. MATERIAL AND METHODS Patients with isolated calcaneal fractures were analyzed. Sanders-type fracture and involvement of both sustentaculum tali and calcaneocuboid joint were detected on computed tomography imaging; postoperative AOFAS scores were analyzed according to sustentacular involvement. RESULTS Fifty calcaneus fractures in 47 patients were included in the final analysis. The sustentaculum tali was fractured in 18 cases (36.0%), thus contradicting its supposed constant position. Sanders type 3 and 4 fractures were more frequently associated with fractured sustentaculum than type 2 (p = 0.012). Sanders type 4 fractures were associated with displaced sustentacular fragment significantly more than type 2 and 3 (p = 0.043). Patients with intact sustentaculum tali reported significantly higher (p < 0.001) mean AOFAS scores than the uninjured group (84.4 ± 9.1 and 74.3 ± 9.5, respectively). CONCLUSION Sanders type 3 and 4 fractures were more frequently associated with sustentaculum tali and/or calcaneocuboid joint involvement than simpler fractures. Injury of sustentaculum tali was related to significant worse postoperative clinical outcomes, underlying the relevance of this fragment on clinical course.
Collapse
Affiliation(s)
- Giacomo Sani
- Department of Surgery and Translation Medicine, University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy
| | - Niccolò Giabbani
- Department of Surgery and Translation Medicine, University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy
| | - Luigi Zanna
- Department of Surgery and Translation Medicine, University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy.
| | - Roberto Buzzi
- Department of Surgery and Translation Medicine, University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy
| | - Angelica Sofia Pio
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit N. 2., University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy
| | - Vieri Rastrelli
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit N. 2., University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy
| | - Cosimo Nardi
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit N. 2., University of Florence - Azienda Ospedaliero-Universitaria Careggi, Largo Palagi 1, 50134, Florence, Italy
| |
Collapse
|
3
|
Tamminen P, Järnstedt J, Lehtinen A, Numminen J, Lehtimäki L, Rautiainen M, Kivekäs I. Ultra-low-dose CBCT scan: rational map for ear surgery. Eur Arch Otorhinolaryngol 2023; 280:1161-1168. [PMID: 36112187 PMCID: PMC9483469 DOI: 10.1007/s00405-022-07592-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Accepted: 08/04/2022] [Indexed: 02/07/2023]
Abstract
PURPOSE This study will evaluate the clinical quality and usability of peripheral image data from the temporal bone area obtained using a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan and compare them to those obtained using a high-resolution (HR) CBCT. METHODS The population consisted of 66 anatomical sites (ears of 33 subjects) imaged using two modalities: an HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and a ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). The image quality (IQ) for every anatomical site in each image was rated using a Likert scale from 0 to 5. RESULTS The quality of ULD CBCT scans was clinically sufficient in over 95% of the assessed images of the sigmoid sinus, jugular bulb, epitympanum and mastoid antrum as well as external acoustic meatus (all p > 0.05 compared to HR CBCT). The IQ was clinically sufficient in 75-94% of the assessed images of the scutum, mastoid segment of the facial nerve, cochlea and semicircular canals (all p < 0.05 compared to HR CBCT). The overall IQ of the HR CBCT scans was good or excellent. CONCLUSION CBCT imaging and the data at image margins are underutilized. CBCT can produce excellent structural resolution with conventional imaging parameters, even with off-focus images. Using ultra-low doses of radiation, the produced IQ is clinically sufficient. We encourage ear surgeons to check the patients' imaging history and to consider the use of imaging modalities that involve lower radiation doses especially when conducting repetitive investigations and with children.
Collapse
Affiliation(s)
- Pekka Tamminen
- Department of Otorhinolaryngology-Head and Neck Surgery, Tampere University Hospital, Elämänaukio 2, 33520, Tampere, Finland.
- Department of Otorhinolaryngology, Satasairaala, Sairaalantie 3, 28500, Pori, Finland.
- Department of Internal Medicine, Tampere University Hospital, Elämänaukio 2, 33520, Tampere, Finland.
- Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön Katu 34, 33520, Tampere, Finland.
| | - Jorma Järnstedt
- Medical Imaging Centre, Department of Radiology, Tampere University Hospital, Teiskontie 35, 33520, Tampere, Finland
| | - Antti Lehtinen
- Medical Imaging Centre, Department of Radiology, Tampere University Hospital, Teiskontie 35, 33520, Tampere, Finland
| | - Jura Numminen
- Department of Otorhinolaryngology-Head and Neck Surgery, Tampere University Hospital, Elämänaukio 2, 33520, Tampere, Finland
| | - Lauri Lehtimäki
- Allergy Centre, Tampere University Hospital, Elämänaukio 2, 33520, Tampere, Finland
- Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön Katu 34, 33520, Tampere, Finland
| | - Markus Rautiainen
- Department of Otorhinolaryngology-Head and Neck Surgery, Tampere University Hospital, Elämänaukio 2, 33520, Tampere, Finland
- Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön Katu 34, 33520, Tampere, Finland
| | - Ilkka Kivekäs
- Department of Otorhinolaryngology-Head and Neck Surgery, Tampere University Hospital, Elämänaukio 2, 33520, Tampere, Finland
| |
Collapse
|
4
|
Gantry-Free High-Resolution Cone-Beam CT: Efficacy for Distal Radius and Scaphoid Fracture Detection and Characterization. Acad Radiol 2022:S1076-6332(22)00486-X. [PMID: 36167629 DOI: 10.1016/j.acra.2022.08.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 08/23/2022] [Accepted: 08/26/2022] [Indexed: 11/20/2022]
Abstract
OBJECTIVES Gantry-free cone-beam CT (CBCT) allows for comfortable patient positioning due to an open scanner architecture. Since CBCT without gantry is not yet established for clinical wrist trauma imaging, this study's aim was to investigate its diagnostic value in the preoperative workup of patients with distal radius and scaphoid fractures. METHODS Within a 12-month period, 113 patients with severe wrist trauma underwent both radiography and CBCT with the same gantry-free multi-use scanner before surgery. Two radiologists retrospectively analyzed all datasets for the morphology of distal radius (n = 95) and scaphoid fractures (n = 20). In all 115 wrists (two bilateral injuries), surgical reports served as the standard of reference. RESULTS While accuracy for distal radius fractures was comparable among CBCT and radiographs, the former was superior with regard to scaphoid fractures (Reader 1: 100.0% vs. 75.0%; Reader 2: 100.0% vs. 65.0%). Accuracy for multi-fragmentary radius injuries (100.0% vs. 90.5%; 100.0% vs. 93.7%), and articular affliction (99.0% vs. 84.2%; 100.0% vs. 83.2%) was also higher in CBCT. Regarding scaphoid fractures, CBCT proved superior for diagnosis of proximal pole or waist involvement (100.0% vs. 70.0%; 100.0% vs. 65.0%) and comminuted patterns (100.0% vs. 70.0%; 100.0% vs. 75.0%). Median effective dose of CBCT was as low as 3.65 µSv compared with 0.16 µSv for standard radiography. CONCLUSION Gantry-free CBCT allows for excellent diagnostic accuracy in the assessment of distal radius and scaphoid fracture morphology. Even in patients with limited mobility, very low radiation dose is sufficient to maintain high image quality.
Collapse
|
5
|
Luetkens KS, Grunz JP, Paul MM, Huflage H, Conrads N, Patzer TS, Gruschwitz P, Ergün S, Bley TA, Kunz AS. One-stop-shop CT arthrography of the wrist without subject repositioning by means of gantry-free cone-beam CT. Sci Rep 2022; 12:14422. [PMID: 36002544 PMCID: PMC9402709 DOI: 10.1038/s41598-022-18395-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 08/10/2022] [Indexed: 11/16/2022] Open
Abstract
Modern cone-beam CT systems are capable of ultra-high-resolution 3D imaging in addition to conventional radiography and fluoroscopy. The combination of various imaging functions in a multi-use setup is particularly appealing for musculoskeletal interventions, such as CBCT arthrography (CBCTA). With this study, we aimed to investigate the feasibility of CBCTA of the wrist in a “one-stop-shop” approach with a gantry-free twin robotic scanner that does not require repositioning of subjects. Additionally, the image quality of CBCTA was compared to subsequent arthrograms on a high-end multidetector CT (MDCTA). Fourteen cadaveric wrists received CBCTA with four acquisition protocols. Specimens were then transferred to the CT suite for additional MDCTA. Dose indices ranged between 14.3 mGy (120 kVp/100 effective mAs; full-dose) and 1.0 mGy (70 kVp/41 effective mAs; ultra-low-dose) for MDCTA and between 17.4 mGy (80 kVp/2.5 mAs per pulse; full-dose) and 1.2 mGy (60 kVp/0.5 mAs per pulse; ultra-low-dose) for CBCTA. Subjective image quality assessment for bone, cartilage and ligamentous tissue was performed by seven radiologists. The interrater reliability was assessed by calculation of the intraclass correlation coefficient (ICC) based on a two-way random effects model. Overall image quality of most CBCTA was deemed suitable for diagnostic use in contrast to a considerable amount of non-diagnostic MDCTA examinations (38.8%). The depiction of bone, cartilage and ligaments in MDCTA with any form of dose reduction was inferior to any CBCTA scan with at least 0.6 mAs per pulse (all p < 0.001). Full-dose MDCTA and low-dose CBCTA were of equal quality for bone tissue visualization (p = 0.326), whereas CBCTA allowed for better depiction of ligaments and cartilage (both p < 0.001), despite merely one third of radiation exposure (MDCTA–14.3 mGy vs. CBCTA–4.5 mGy). Moderate to good interrater reliability was ascertained for the assessment all tissues (ICC 0.689–0.756). Overall median examination time for CBCTA was 5.4 min (4.8–7.2 min). This work demonstrates that substantial dose reduction can be achieved in CT arthrography of the wrist while maintaining diagnostic image quality by employing the cone-beam CT mode of a twin robotic X-ray system. The ability of the multi-use X-ray system to switch between fluoroscopy mode and 3D imaging allows for “one-stop-shop” CBCTA in minimal examination time without the need for repositioning.
Collapse
Affiliation(s)
- Karsten Sebastian Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Mila Marie Paul
- Department of Orthopedic Trauma, Hand, Plastic and Reconstructive Surgery, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Nora Conrads
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Theresa Sophie Patzer
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Philipp Gruschwitz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Süleyman Ergün
- Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstr. 6, 97070, Würzburg, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Andreas Steven Kunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| |
Collapse
|
6
|
Combining gantry-free cone-beam computed tomography with iterative metal artefact reduction for surgical follow-up imaging of the appendicular skeleton. Eur J Radiol 2022; 155:110465. [PMID: 35973302 DOI: 10.1016/j.ejrad.2022.110465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 07/23/2022] [Accepted: 08/06/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE Post-surgical evaluation of osteosynthesis material and adjacent tissue can be challenging in both radiography and cross-sectional imaging. This study investigates the performance of a multi-purpose X-ray scanner with cone-beam CT (CBCT) function and iterative metal artefact reduction capabilities in patients after osteoplasty of the appendicular skeleton. METHOD Eighty individuals who underwent both conventional X-ray imaging and CBCT after osteoplasty of the hand/wrist (48), elbow (14), or ankle/foot (18) with the gantry-free twin robotic system were retrospectively enrolled. Radiological reports from clinical routine for both imaging modalities were retrospectively analyzed and compared with consensus expert reading by two musculoskeletal specialists serving as the standard of reference. Findings of screw dislocation or implant loosening, fragment displacement, and delayed healing were compared between X-ray and CBCT reports using the McNemar test. RESULTS The median dose-area-product of CBCT and X-ray scans amounted to 27.98 and 0.2 dGy*cm2, respectively. Diagnostic accuracy for screw dislocation was superior in CBCT compared to standard radiograms (98.8 % vs 83.8 %; p = 0.002). Implant loosening (98.8 % vs 86.3 %; p = 0.006), fragment displacement (98.8 % vs 85.0 %; p < 0.001), and delayed healing (97.5 % vs 88.8 %; p = 0.016) were also more reliably detected in CBCT. Employing CBCT, postoperative complications were detected with a sensitivity and specificity of at least 95.8 % and 98.1 %, compared to 33.3 % and 92.86 % in radiography. CONCLUSIONS With superior accuracy for various osteoplasty-related complications, the CBCT scan mode of a gantry-free twin robotic X-ray system with iterative metal artefact reduction aids post-surgical assessment in the appendicular skeleton.
Collapse
|
7
|
Landsberg R, Schneider S, Masalha M, Margulis A, Guindy M, Luckman J. Comparison of CT and adjusted MRI for evaluating paranasal sinuses surgical key landmarks. RHINOLOGY ONLINE 2022. [DOI: 10.4193/rhinol/21.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Background: Sinus CT is the imaging technique of choice for planning endoscopic sinus surgery (ESS). Although MRI has a better soft tissue demonstration, it is not commonly used for ESS due to suboptimal bone demonstration. We hypothesised that adjustment of certain MRI parameters, would allow better demonstration of bones and enable the surgeon to adequately identify surgical landmarks. Methodology: Twenty patients identified as candidates for ESS underwent CT and adjusted MRI exams of the paranasal sinuses (40 in total). rhinologist and a neuroradiologist independently compared and graded 46 bony structures (23 on each side) in each patient's CT and MRI. Overall, 920 anatomical structures were graded by each observer (1840 structures in total). Statistical analysis included overall and per variable grading distribution for each observer, and overall agreement. Results: MRI images were equal, or superior to CT for assessing paranasal anatomy in 66.8% and 86.4% of structures evaluated by the rhinologist and neuroradiologist, respectively. Overall agreement between observers (77%) was moderate. Conclusion: The rhinologist prefers CT demonstration of bony structures, while the neuroradiologist prefers MRI. Still, with the MRI protocol used in this study, according to both, most bony structures are well demonstrated by MRI.
Collapse
|
8
|
Techniques, Tricks, and Stratagems of Oral Cavity Computed Tomography and Magnetic Resonance Imaging. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12031473] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The oral cavity constitutes a complex anatomical area that can be affected by many developmental, inflammatory, and tumoural diseases. MultiSlice Computed Tomography (MSCT) and Magnetic Resonance Imaging (MRI) currently represent the essential and complementary imaging techniques for detecting oral cavity abnormalities. Advanced MRI with diffusion-weighted imaging (DWI) and dynamic contrast-enhanced perfusion-weighted imaging (DCE-PWI) has recently increased the ability to characterise oral lesions and distinguish disease recurrences from post therapy changes. The analysis of the oral cavity area via imaging techniques is also complicated both by mutual close appositions of different mucosal surfaces and metal artifacts from dental materials. Nevertheless, an exact identification of oral lesions is made possible thanks to dynamic manoeuvres and specific stratagems applicable on MSCT and MRI acquisitions. This study summarises the currently available imaging techniques for oral diseases, with particular attention to the role of DWI, DCE-PWI, and dynamic manoeuvres. We also propose MSCT and MRI acquisition protocols for an accurate study of the oral cavity area.
Collapse
|
9
|
Muñoz-Galván A, Fiori-Chíncaro GA, Agudelo-Botero AM. [Applications of cone beam computed tomography of the craneofacial structure in medical specialties. A review]. REVISTA CIENTÍFICA ODONTOLÓGICA 2022; 10:e100. [PMID: 38389916 PMCID: PMC10880726 DOI: 10.21142/2523-2754-1001-2022-100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 01/01/2022] [Indexed: 02/24/2024] Open
Abstract
Cone-beam computed tomography (CBCT) of the craniofacial structure has demonstrated its usefulness in the dental area during the last decades, thus it has become a fundamental tool in the diagnosis, planning, and evaluation of treatment, and although it was not developed for the exclusive use in dentistry, as it is commonly considered, it is used in other areas such as medicine. It is specifically used in the head and neck area where different medical specialties interact, and at the same time these interact with dental specialties, so knowing the advantages of CBCT over different imaging technologies in the medical area is necessary. The purpose of this review was to describe the applications of observation, diagnosis, planning, and evolution of treatments using maxillofacial HSCT in different medical specialties. This work highlights the use of TCHC in different medical applications and highlights where it is most useful compared to other technologies.
Collapse
Affiliation(s)
- Agustín Muñoz-Galván
- Division de Radiologia Bucal y Maxilofacial, Universidad Cientifica del Sur. Lima, Peru. Universidad Científica del Sur Division de Radiologia Bucal y Maxilofacial Universidad Cientifica del Sur Lima Peru
| | - Gustavo Adolfo Fiori-Chíncaro
- Instituto Latinoamericano de Altos Estudios en Estomatologia (ILAE). Lima, Peru. , Instituto Latinoamericano de Altos Estudios en Estomatologia (ILAE) Lima Peru
| | - Ana María Agudelo-Botero
- Instituto Latinoamericano de Altos Estudios en Estomatologia (ILAE). Lima, Peru. , Instituto Latinoamericano de Altos Estudios en Estomatologia (ILAE) Lima Peru
| |
Collapse
|
10
|
Jwair S, Boerboom RA, Versnel H, Stokroos RJ, Thomeer HGXM. Evaluating cochlear insertion trauma and hearing preservation after cochlear implantation (CIPRES): a study protocol for a randomized single-blind controlled trial. Trials 2021; 22:895. [PMID: 34886884 PMCID: PMC8656003 DOI: 10.1186/s13063-021-05878-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 11/25/2021] [Indexed: 12/26/2022] Open
Abstract
Background In order to preserve residual hearing in patients with sensorineural hearing loss (SNHL) who receive a cochlear implant (CI), insertion trauma to the delicate structures of the cochlea needs to be minimized. The surgical approach comprises the conventional mastoidectomy-posterior tympanotomy (MPT) to arrive at the middle ear, followed by either a cochleostomy (CO) or the round window (RW) approach. Both techniques have their benefits and disadvantages. Another important aspect in structure preservation is the design of the electrode array. Two different designs are used: a “straight” lateral wall lying electrode array (LW) or a “pre-curved” perimodiolar lying electrode array (PM). Interestingly, until now, the best surgical approach and design of the implant is uncertain. Our hypothesis is that there is a difference in hearing preservation outcomes between the four possible treatment options. Methods We designed a monocenter, multi-arm, randomized controlled trial to compare insertion trauma between four groups of patients, with each group having a unique combination of an electrode array type (LW or PM) and surgical approach (RW or CO). In total, 48 patients will be randomized into one of these four intervention groups. Our primary objective is the comparison of postoperative hearing preservation between these four groups. Secondly, we aim to assess structure preservation (i.e., scalar translocation, with basilar membrane disruption or tip fold-over of array) for each group. Thirdly, we will compare objective outcomes of hearing and structure preservation by way of electrocochleography (ECochG). Discussion Cochlear implantation by way of a cochleostomy or round window approach, using different electrode array types, is the standard medical care for patients with severe to profound bilateral sensorineural hearing loss, as it is a relatively simple and low-risk procedure that greatly benefits patients. However, loss of residual hearing remains a problem. This trial is the first randomized controlled trial that evaluates the effect of cochlear insertion trauma of several CI treatment options on hearing preservation. Trial registration Netherlands Trial Register (NTR) NL8586. Registered on 4 May 2020. Retrospectively registered; 3/48 participants were included before registration. Supplementary Information The online version contains supplementary material available at 10.1186/s13063-021-05878-2.
Collapse
Affiliation(s)
- Saad Jwair
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands. .,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands.
| | - Ralf A Boerboom
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Robert J Stokroos
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Hans G X M Thomeer
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| |
Collapse
|
11
|
Tarsitano A, Ricotta F, Spinnato P, Chiesa AM, Di Carlo M, Parmeggiani A, Miceli M, Facchini G. Craniofacial Osteomas: From Diagnosis to Therapy. J Clin Med 2021; 10:jcm10235584. [PMID: 34884284 PMCID: PMC8658100 DOI: 10.3390/jcm10235584] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 11/19/2021] [Accepted: 11/24/2021] [Indexed: 12/18/2022] Open
Abstract
An osteoma is a benign bone lesion with no clear pathogenesis, almost exclusive to the craniofacial area. Osteomas show very slow continuous growth, even in adulthood, unlike other bony lesions. Since these lesions are frequently asymptomatic, the diagnosis is usually made by plain radiography or by a computed tomography (CT) scan performed for other reasons. Rarely, the extensive growth could determine aesthetic or functional problems that vary according to different locations. Radiographically, osteomas appear as radiopaque lesions similar to bone cortex, and may determine bone expansion. Cone beam CT is the optimal imaging modality for assessing the relationship between osteomas and adjacent structures, and for surgical planning. The differential diagnosis includes several inflammatory and tumoral pathologies, but the typical craniofacial location may aid in the diagnosis. Due to the benign nature of osteomas, surgical treatment is limited to symptomatic lesions. Radical surgical resection is the gold standard therapy; it is based on a minimally invasive surgical approach with the aim of achieving an optimal cosmetic result. Reconstructive surgery for an osteoma is quite infrequent and reserved for patients with large central osteomas, such as big mandibular or maxillary lesions. In this regard, computer-assisted surgery guarantees better outcomes, providing the possibility of preoperative simulation of demolitive and reconstructive surgery.
Collapse
Affiliation(s)
- Achille Tarsitano
- Maxillofacial Surgery Unit, IRCCS Policlinico di S. Orsola, 40138 Bologna, Italy; (A.T.); (F.R.)
| | - Francesco Ricotta
- Maxillofacial Surgery Unit, IRCCS Policlinico di S. Orsola, 40138 Bologna, Italy; (A.T.); (F.R.)
| | - Paolo Spinnato
- Diagnostic and Interventional Radiology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.S.); (A.M.C.); (M.D.C.); (M.M.); (G.F.)
| | - Anna Maria Chiesa
- Diagnostic and Interventional Radiology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.S.); (A.M.C.); (M.D.C.); (M.M.); (G.F.)
| | - Maddalena Di Carlo
- Diagnostic and Interventional Radiology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.S.); (A.M.C.); (M.D.C.); (M.M.); (G.F.)
| | - Anna Parmeggiani
- Diagnostic and Interventional Radiology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.S.); (A.M.C.); (M.D.C.); (M.M.); (G.F.)
- Correspondence: ; Tel.: +0039-05163-66273
| | - Marco Miceli
- Diagnostic and Interventional Radiology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.S.); (A.M.C.); (M.D.C.); (M.M.); (G.F.)
| | - Giancarlo Facchini
- Diagnostic and Interventional Radiology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.S.); (A.M.C.); (M.D.C.); (M.M.); (G.F.)
| |
Collapse
|
12
|
Luetkens KS, Huflage H, Kunz AS, Ritschl L, Herbst M, Kappler S, Ergün S, Goertz L, Pennig L, Bley TA, Gassenmaier T, Grunz JP. The effect of tin prefiltration on extremity cone-beam CT imaging with a twin robotic X-ray system. Radiography (Lond) 2021; 28:433-439. [PMID: 34716089 DOI: 10.1016/j.radi.2021.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 08/13/2021] [Accepted: 10/09/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION While tin prefiltration is established in various CT applications, its value in extremity cone-beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. METHODS Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. RESULTS Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper-filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. CONCLUSION Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic X-ray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. IMPLICATIONS FOR PRACTICE Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage.
Collapse
Affiliation(s)
- K S Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - H Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - A S Kunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - L Ritschl
- X-ray Products - Research & Development, Siemens Healthcare GmbH, Siemensstraße 1, 91301, Forchheim, Germany.
| | - M Herbst
- X-ray Products - Research & Development, Siemens Healthcare GmbH, Siemensstraße 1, 91301, Forchheim, Germany.
| | - S Kappler
- X-ray Products - Research & Development, Siemens Healthcare GmbH, Siemensstraße 1, 91301, Forchheim, Germany.
| | - S Ergün
- Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070 Würzburg, Germany.
| | - L Goertz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany.
| | - L Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937 Cologne, Germany.
| | - T A Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - T Gassenmaier
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - J-P Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| |
Collapse
|
13
|
Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system. Sci Rep 2021; 11:20176. [PMID: 34635787 PMCID: PMC8505435 DOI: 10.1038/s41598-021-99748-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 09/22/2021] [Indexed: 11/09/2022] Open
Abstract
Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current-time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FDUr77 and LDUr77 examinations (p < 0.001) with LDUr77 scans also providing favorable bone visualization compared to FDBr69 and FDBr62 (p < 0.001). Fleiss' kappa was 0.618 (0.594-0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.
Collapse
|
14
|
Jandl NM, Rolvien T, Rupp T, Schumacher U, Püschel K, Maas KJ, Amling M, Henes FO, Spink C. Diagnostic yield of cone beam computed tomography for small foreign body detection in the hand in comparison with radiography, MSCT and MRI: an ex vivo study. Injury 2021; 52:2841-2847. [PMID: 33487409 DOI: 10.1016/j.injury.2021.01.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 01/07/2021] [Accepted: 01/11/2021] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Detection of symptomatic foreign bodies (FB) after penetrating hand injuries can be challenging. Multiplanar radiography is most frequently used for FB detection and may be complemented by multislice computed tomography (MSCT) if suspected FBs cannot be identified and clinical symptoms are persisting. Cone beam computed tomography (CBCT) is a promising imaging modality for traumatology aside from fracture detection. The aim of this study was to evaluate the diagnostic yield of CBCT for different small FBs in the hand in comparison with radiography, MSCT and magnetic resonance imaging (MRI). METHODS In ten cadaveric hands of voluntary body donors, 20 different FBs (metal, glass, stone, wood, thorn) in predefined sizes (0.5, 1 and 2mm) were randomly placed in the central hand and the basal phalanges. All hands were imaged using radiography, 256-slice CT, CBCT, and 3T MRI. A total of 200 subcutaneous and intramuscular particles were analyzed for their visibility by two observers at two time points. The Cohens Kappa coefficient was calculated as a measure of interobserver agreement and intraobserver reliability. The particle detection rate between different imaging modalities was compared using McNemar Chi2-tests. RESULTS CBCT and MSCT provided a higher detection rate (94.6% and 86.3%) for detecting metal, glass and stone particles compared to standard radiography (70.0%; each p<0.001). MRI did not provide a diagnostic benefit. Wood particles and thorns were not reliably recognizable by any imaging technique. The interobserver agreement (K=0.768; p<0.001) and the intraobserver reliability for both observers (K1=0.914 and K2=0.907; p<0.001) were good. The dose length product (DLP) was 2-fold lower in CBCT than in MSCT (39.2 ± 2.1 vs. 81.4 ± 2.9 mGy*cm; p<0.001). CONCLUSIONS In this ex vivo study, CBCT provided a high detection rate for small metal, glass, and stone particles while the radiation exposure was significantly lower compared to MSCT. These results suggest that CBCT instead of MSCT seems a reasonable option in supplementary diagnostics to exclude of FBs. The primary use of CBCT instead of radiography may be considered for symptomatic patients with expected small radiopaque particles <1mm. Organic FBs can be visualized indirectly in MRI and CBCT/MSCT by entrapped surrounding air. LEVEL OF EVIDENCE Level I, diagnostic study.
Collapse
Affiliation(s)
- Nico Maximilian Jandl
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Tim Rolvien
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Tobias Rupp
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Udo Schumacher
- Institute of Anatomy and Experimental Morphology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Klaus Püschel
- Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Kai-Jonathan Maas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Frank Oliver Henes
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Clemens Spink
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|
15
|
Wang TH, Yu WC, Chen ZH, Tien YH, Chen WM, Chiu FY, Wang SJ. The symmetry indices of malar mounds for zygomatic bone fracture management based on a computed tomographic model. J Chin Med Assoc 2021; 84:709-712. [PMID: 34050106 DOI: 10.1097/jcma.0000000000000556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND To date, plastic surgeons do not have an objective method of measuring facial symmetry for zygomatic bone fracture management. Based on clinical practice, the authors utilized a 3-dimensional (3D) model to propose the symmetry index from the anterior view (SIAV) and the symmetry index from inferior view (SIIV). This study aimed to assess the application of these 2 indices. METHODS The SIAV is defined as the distance between the superior and lower orbital rims (DSLOR) of the defective side divided by that of the healthy side in the anterior view. The SIIV is defined as the area within the region of interest (AROI) of the defective side divided by that of the healthy side in the inferior view. We retrospectively reviewed 95 patients who underwent zygomatic fracture surgery at our medical center from January 2017 to September 2020. The Patients who had bilateral zygomatic fractures and did not have both pre- and postoperative computed tomography (CT) images were excluded. RESULTS Five out of the 95 patients were enrolled in this study. The difference between pre- and postoperative mean AROI and DSLOR on the healthy side was not significant. The insignificant difference indicates the repeatability of the measurement of the 3D skull model and different CT machines would not affect the calculation of AROI and DSLOR. The mean values of postoperative SIAV (1.06 ± 0.07) and SIIV (1.02 ± 0.08) were closer to 1 than the preoperative values (0.97 ± 0.09 and 1.10 ± 0.12). Although the difference was not statistically significant, the SIIV and SIAV would numerically present the changes in malar bone fracture postoperatively. CONCLUSION The SIAV and SIIV based on clinical practice could numerically assess the symmetry of the malar mound.
Collapse
Affiliation(s)
- Tien-Hsiang Wang
- Division of Plastic Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei Taiwan, ROC
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Mechanical Engineering, National Central University, Taoyuan, Taiwan, ROC
| | - Wen-Chan Yu
- Rehabilitation and Technical Aids Center, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Zih-Hua Chen
- Rehabilitation and Technical Aids Center, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Yao-Hsuan Tien
- Division of Plastic Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei Taiwan, ROC
| | - Wei-Ming Chen
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics & Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Fang-Yau Chiu
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Rehabilitation and Technical Aids Center, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Shyh-Jen Wang
- Rehabilitation and Technical Aids Center, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
- Division of Experimental Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei Taiwan, ROC
- Institute of Hospital and Health Care Administration, National Yang Ming Chiao Tung University, Taipei Taiwan, ROC
| |
Collapse
|
16
|
Rolvien T, Jandl NM, Stürznickel J, Beil FT, Kötter I, Oheim R, Lohse AW, Barvencik F, Amling M. Clinical and Radiological Characterization of Patients with Immobilizing and Progressive Stress Fractures in Methotrexate Osteopathy. Calcif Tissue Int 2021; 108:219-230. [PMID: 33064170 PMCID: PMC7819927 DOI: 10.1007/s00223-020-00765-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 09/29/2020] [Indexed: 11/06/2022]
Abstract
Methotrexate (MTX) is one of the most commonly prescribed drugs for autoimmune rheumatic diseases. As there is no consensus on its negative effects on bone, the purpose of this investigation was to determine the clinical spectrum of patients with stress fractures due to long-term MTX treatment (i.e., MTX osteopathy). We have retrospectively analyzed data from 34 patients with MTX treatment, severe lower extremity pain and immobilization. MRI scans, bone turnover markers, bone mineral density (DXA) and bone microarchitecture (HR-pQCT) were evaluated. Stress fractures were also imaged with cone beam CT. While the time between clinical onset and diagnosis was prolonged (17.4 ± 8.6 months), the stress fractures had a pathognomonic appearance (i.e., band-/meander-shaped, along the growth plate) and were diagnosed in the distal tibia (53%), the calcaneus (53%), around the knee (62%) and at multiple sites (68%). Skeletal deterioration was expressed by osteoporosis (62%) along with dissociation of low bone formation and increased bone resorption. MTX treatment was discontinued in 27/34 patients, and a combined denosumab-teriparatide treatment initiated. Ten patients re-evaluated at follow-up (2.6 ± 1.5 years) had improved clinically in terms of successful remobilization. Taken together, our findings provide the first in-depth skeletal characterization of patients with pathognomonic stress fractures after long-term MTX treatment.
Collapse
Affiliation(s)
- Tim Rolvien
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestraße 59, 22529, Hamburg, Germany
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Nico Maximilian Jandl
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestraße 59, 22529, Hamburg, Germany
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Julian Stürznickel
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestraße 59, 22529, Hamburg, Germany
| | - Frank Timo Beil
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Ina Kötter
- 3rd Department of Medicine (Rheumatology), University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Ralf Oheim
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestraße 59, 22529, Hamburg, Germany
| | - Ansgar W Lohse
- 1st Department of Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Florian Barvencik
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestraße 59, 22529, Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestraße 59, 22529, Hamburg, Germany.
| |
Collapse
|
17
|
Grunz JP, Pennig L, Fieber T, Gietzen CH, Heidenreich JF, Huflage H, Gruschwitz P, Kuhl PJ, Petritsch B, Kosmala A, Bley TA, Gassenmaier T. Twin robotic x-ray system in small bone and joint trauma: impact of cone-beam computed tomography on treatment decisions. Eur Radiol 2020; 31:3600-3609. [PMID: 33280057 PMCID: PMC8128787 DOI: 10.1007/s00330-020-07563-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Revised: 09/24/2020] [Accepted: 11/25/2020] [Indexed: 12/11/2022]
Abstract
Objectives Trauma evaluation of extremities can be challenging in conventional radiography. A multi-use x-ray system with cone-beam CT (CBCT) option facilitates ancillary 3-D imaging without repositioning. We assessed the clinical value of CBCT scans by analyzing the influence of additional findings on therapy. Methods Ninety-two patients underwent radiography and subsequent CBCT imaging with the twin robotic scanner (76 wrist/hand/finger and 16 ankle/foot/toe trauma scans). Reports by on-call radiologists before and after CBCT were compared regarding fracture detection, joint affliction, comminuted injuries, and diagnostic confidence. An orthopedic surgeon recommended therapy based on reported findings. Surgical reports (N = 52) and clinical follow-up (N = 85) were used as reference standard. Results CBCT detected more fractures (83/64 of 85), joint involvements (69/53 of 71), and multi-fragment situations (68/50 of 70) than radiography (all p < 0.001). Six fractures suspected in radiographs were ruled out by CBCT. Treatment changes based on additional information from CBCT were recommended in 29 patients (31.5%). While agreement between advised therapy before CBCT and actual treatment was moderate (κ = 0.41 [95% confidence interval 0.35–0.47]; p < 0.001), agreement after CBCT was almost perfect (κ = 0.88 [0.83–0.93]; p < 0.001). Diagnostic confidence increased considerably for CBCT studies (p < 0.001). Median effective dose for CBCT was 4.3 μSv [3.3–5.3 μSv] compared to 0.2 μSv [0.1–0.2 μSv] for radiography. Conclusions CBCT provides advantages for the evaluation of acute small bone and joint trauma by detecting and excluding extremity fractures and fracture-related findings more reliably than radiographs. Additional findings induced therapy change in one third of patients, suggesting substantial clinical impact. Key Points • With cone-beam CT, extremity fractures and fracture-related findings can be detected and ruled out more reliably than with conventional radiography. • Additional diagnostic information provided by cone-beam CT scans has substantial impact on therapy in small bone and joint trauma. • For distal extremity injury assessment, one-stop-shop imaging without repositioning is feasible with the twin robotic x-ray system.
Collapse
Affiliation(s)
- Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
| | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Tabea Fieber
- Department of Trauma, Hand, Plastic and Reconstructive Surgery, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Carsten Herbert Gietzen
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Julius Frederik Heidenreich
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Philipp Gruschwitz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Philipp Josef Kuhl
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Bernhard Petritsch
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Aleksander Kosmala
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Tobias Gassenmaier
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| |
Collapse
|
18
|
Martino M, Fodor D, Fresilli D, Guiban O, Rubini A, Cassoni A, Ralli M, De Vincentiis C, Arduini F, Celletti I, Pacini P, Polti G, Polito E, Greco A, Valentini V, Sorrenti S, D'Andrea V, Masciocchi C, Barile A, Cantisani V. Narrative review of multiparametric ultrasound in parotid gland evaluation. Gland Surg 2020; 9:2295-2311. [PMID: 33447581 DOI: 10.21037/gs-20-530] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Disorders affecting parotid gland represent a heterogeneous group comprising congenital, inflammatory and neoplastic diseases which show a focal or diffuse pattern of appearance. The differentiation of neoplastic from non-neoplastic conditions of parotid glands is pivotal for the diagnostic imaging. Frequently there is evidence of overlapping between the clinical and the imaging appearance of the various pathologies. The parotid gland is also often object of study with the combination of different techniques [ultrasound-computed tomography-magnetic resonance imaging (US-CT-MRI), ex.]. Compared to other dominant methods of medical imaging, US has several advantages providing images in real-time at lower cost, and without harmful use of ionizing radiation and of contrast enhancement. B-mode US, and the microvascular pattern color Doppler are usually used as first step evaluation of parotid lesions. Elastography and contrast-enhanced US (CEUS) has opened further possible perspectives to improve the differentiation between benign and malignant parotid lesions. The characterization of the parotid tumors plays a crucial role for their treatment planning and for the prediction of possible surgical complications. We present, here an updated review of the most recurrent pathologies of parotid gland focusing on the diagnostic power of multiparametric US including CEUS and ultrasound elastography (USE); limitations, advantages and the main key-points will be presented.
Collapse
Affiliation(s)
- Milvia Martino
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Daniela Fodor
- 2nd Internal Medicine Department, "Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Daniele Fresilli
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Olga Guiban
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | | | - Andrea Cassoni
- Department of Maxillofacial Surgery, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Massimo Ralli
- Department of Sense Organs, Sapienza University of Rome, Rome, Italy
| | | | - Federico Arduini
- Department of Radiology, Ospedale Santa Maria del Carmine, Rovereto, Italy
| | - Ilaria Celletti
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Patrizia Pacini
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Giorgia Polti
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Eleonora Polito
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Antonio Greco
- Department of Sense Organs, Sapienza University of Rome, Rome, Italy
| | - Valentino Valentini
- Department of Maxillofacial Surgery, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Salvatore Sorrenti
- Department of Surgical Sciences, "Sapienza" University of Rome, Rome, Italy
| | - Vito D'Andrea
- Department of Surgical Sciences, "Sapienza" University of Rome, Rome, Italy
| | - Carlo Masciocchi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Antonio Barile
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Vito Cantisani
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| |
Collapse
|
19
|
Wuokko-Landén A, Blomgren K, Suomalainen A, Välimaa H. Odontogenic causes complicating the chronic rhinosinusitis diagnosis. Clin Oral Investig 2020; 25:947-955. [PMID: 32500403 PMCID: PMC7878247 DOI: 10.1007/s00784-020-03384-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Accepted: 05/27/2020] [Indexed: 11/10/2022]
Abstract
Objectives Chronic rhinosinusitis (CRS) frequently stems from a dental origin, although odontogenic sinusitis (OS) remains underdiagnosed amongst different professionals. This study aimed to explore how often odontogenic causes are considered when diagnosing CRS. Materials and methods Patient records from 374 new CRS patients treated at a tertiary-level ear, nose, and throat (ENT) clinic were selected. Entries and radiological reports were assessed exploring how often dentition was mentioned and OS was suspected, how often radiologists reported maxillary teeth, and how commonly typical OS microbial findings and unilateral symptoms occurred. Results Although 10.1% of the CRS diagnoses were connected to possible dental issues, teeth were not mentioned for 73.8% of patients. Radiological reports were available from 267 computed or cone beam computed tomographies, of which 25.1% did not mention the maxillary teeth. The reported maxillary teeth pathology was not considered in 31/64 (48.4%) cases. Unilateral symptoms associated with apical periodontitis (OR = 2.49, 95% CI 1.27–4.89, p = 0.008). Microbial samples were available from 88 patients, for whom Staphylococcus aureus was the most common finding (17% of samples). Conclusions Odontogenic causes are often overlooked when diagnosing CRS. To provide adequate treatment, routine assessment of patient’s dental history and status, careful radiograph evaluation, and utilization of microbial findings should be performed. Close cooperation with dentists is mandatory. Clinical relevance Dental professionals should be aware of difficulties medical professionals encounter when diagnosing possible OS. Thus, sufficient knowledge of OS pathology is essential to both medical and dental professionals.
Collapse
Affiliation(s)
| | - Karin Blomgren
- Department of Otorhinolaryngology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Anni Suomalainen
- HUS Medical Imaging Center, Department of Radiology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Hannamari Välimaa
- Department of Virology, University of Helsinki, Helsinki, Finland
- Department of Oral and Maxillofacial Surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| |
Collapse
|
20
|
Nardi C, Vignoli C, Pietragalla M, Tonelli P, Calistri L, Franchi L, Preda L, Colagrande S. Imaging of mandibular fractures: a pictorial review. Insights Imaging 2020; 11:30. [PMID: 32076873 PMCID: PMC7031477 DOI: 10.1186/s13244-020-0837-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 01/23/2020] [Indexed: 11/23/2022] Open
Abstract
Mandibular fractures are among the most common maxillofacial fractures observed in emergency rooms and are mainly caused by road accidents. The clinical features of mandibular fractures include malocclusion and loss of mandibular function. Panoramic radiography is usually limited to isolated lesions, whereas computed tomography is the tool of choice for all other facial traumatic events. No reference standard classification system for the different types of mandibular fractures is defined. Therapeutic options include a conservative approach or surgical treatment based on the anatomic area and the severity of fracture. The main purpose of this pictorial review is to illustrate a practical description of the pathophysiology of mandibular fractures and describe both the imaging techniques to recognise them and the therapeutic indications.
Collapse
Affiliation(s)
- Cosimo Nardi
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, University of Florence-Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134, Florence, Italy
| | - Chiara Vignoli
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, University of Florence-Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134, Florence, Italy
| | - Michele Pietragalla
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, University of Florence-Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134, Florence, Italy
| | - Paolina Tonelli
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, University of Florence-Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134, Florence, Italy
| | - Linda Calistri
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, University of Florence-Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134, Florence, Italy
| | - Lorenzo Franchi
- Department of Surgery and Translational Medicine, University of Florence, Via del Ponte di Mezzo, 46-48, 50127, Florence, Italy.,Department of Orthodontics and Pediatric Dentistry, School of Dentistry, University of Michigan, Ann Arbor, USA
| | - Lorenzo Preda
- Department of Clinical-Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Via Alessandro Brambilla, 74, 27100, Pavia, Italy. .,Diagnostic Imaging Unit, National Centre of Oncological Hadrontherapy (CNAO), Pavia, Italy.
| | - Stefano Colagrande
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, University of Florence-Azienda Ospedaliero-Universitaria Careggi, Largo Brambilla 3, 50134, Florence, Italy
| |
Collapse
|
21
|
Alagic Z, Bujila R, Enocson A, Srivastava S, Koskinen SK. Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects. Skeletal Radiol 2020; 49:531-539. [PMID: 31501959 PMCID: PMC7021773 DOI: 10.1007/s00256-019-03309-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/28/2019] [Accepted: 08/29/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures. MATERIALS AND METHODS An ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emergency department were evaluated prospectively. After initial digital radiographs, an ultra-low-dose CT was performed. Two readers independently analyzed the images. Also, the radiation dose, examination time, and time to preliminary report was compared between digital radiographs and CT. RESULTS In 207 extremities, digital radiography and ultra-low-dose CT detected 73 and 109 fractures, respectively (p < 0.001). The odds ratio for fracture detection with ultra-low-dose CT vs. digital radiography was 2.0 (95% CI, 1.4-3.0). CT detected additional fracture-related findings in 33 cases (15.9%) and confirmed or ruled out suspected fractures in 19 cases (9.2%). The mean effective dose was comparable between ultra-low-dose CT and digital radiography (0.59 ± 0.33 μSv, 95% CI 0.47-0.59 vs. 0.53 ± 0.43 μSv, 95% CI 0.54-0.64). The mean combined examination time plus time to preliminary report was shorter for ultra-low-dose CT compared to digital radiography (7.6 ± 2.5 min, 95% CI 7.1-8.1 vs. 9.8 ± 4.7 min, 95% CI 8.8-10.7) (p = 0.002). The recommended treatment changed in 34 (16.4%) extremities. CONCLUSIONS Ultra-low-dose CT is a useful alternative to digital radiography for imaging the peripheral skeleton in the acute setting as it detects significantly more fractures and provides additional clinically important information, at a comparable radiation dose. It also provides faster combined examination and reporting times.
Collapse
Affiliation(s)
- Zlatan Alagic
- Functional Unit for Musculoskeletal Radiology Function Imaging and Physiology, Karolinska University Hospital, Karolinska Vägen Solna, 17176 Stockholm, Sweden ,Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden
| | - Robert Bujila
- Functional Unit for Medical Radiation Physics and Nuclear Medicine, Function Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden ,Department of Physics, Royal Institute of Technology, Stockholm, Sweden
| | - Anders Enocson
- Department of Molecular Medicine and Surgery, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Subhash Srivastava
- Functional Unit for Musculoskeletal Radiology Function Imaging and Physiology, Karolinska University Hospital, Karolinska Vägen Solna, 17176 Stockholm, Sweden
| | - Seppo K. Koskinen
- Functional Unit for Musculoskeletal Radiology Function Imaging and Physiology, Karolinska University Hospital, Karolinska Vägen Solna, 17176 Stockholm, Sweden ,Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
22
|
Electronic processing of digital panoramic radiography for the detection of apical periodontitis. Radiol Med 2019; 125:145-154. [PMID: 31701292 DOI: 10.1007/s11547-019-01102-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 10/24/2019] [Indexed: 10/25/2022]
Abstract
INTRODUCTION This study aimed to evaluate the accuracy of both digital complete and small portion of panoramic radiography (PAN) in the detection of clinically/surgically confirmed asymptomatic apical periodontitis (AP) lesions with and without endodontic treatment. METHODS A total of 480 patients/teeth including 120 AP with and without endodontic treatment, and 120 healthy periapex with and without endodontic treatment were detected via CBCT using the periapical index system. Each diseased and healthy patient underwent PAN first and a CBCT scan within 40 days. All 480 cases were assessed by four different methods, as follows: complete PAN with clinical examination of each tooth available and not available, respectively, and small portion of PAN in which a root with crown and root without crown were displayed, respectively. Periapical index system was also used to assess AP by PAN. Accuracy for both complete and small portion of PAN with respect to CBCT was analyzed. RESULTS The overall accuracy of the four methods for teeth with endodontic treatment (73.4) was higher than teeth without endodontic treatment (66.6). Accuracy of complete PAN and portion of PAN was 71.3 and 68.7, respectively. As regards teeth without endodontic treatment, accuracy was higher for complete PAN in the upper/lower incisive area and for small portion of PAN in the upper molar area. No difference was found in teeth with endodontic treatment. CONCLUSION Complete and small portion of PAN showed greater accuracy in the upper/lower incisive area and upper molar area of untreated teeth, respectively, whereas no difference was found in treated teeth.
Collapse
|
23
|
Third-generation dual-source dual-energy CT in pediatric congenital heart disease patients: state-of-the-art. Radiol Med 2019; 124:1238-1252. [PMID: 31630332 DOI: 10.1007/s11547-019-01097-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 10/09/2019] [Indexed: 12/11/2022]
|
24
|
Incorporating Cone-Beam CT Into the Diagnostic Algorithm for Suspected Radiocarpal Fractures: A New Standard of Care? AJR Am J Roentgenol 2019; 213:1117-1123. [PMID: 31287723 DOI: 10.2214/ajr.19.21478] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE. The purpose of this study was to assess the result of adding cone-beam CT to the standard imaging algorithm for patients with suspected radiographically occult traumatic radiocarpal fractures. SUBJECTS AND METHODS. A prospective review was performed on all patients who had cone-beam CT investigation of acute wrist pain after normal initial radiographs. Patients with no identified fractures were clinically reassessed and referred for MRI if concern for a fracture persisted. RESULTS. In all, 117 patients were assessed; 50.4% had fractures identified with a total of 67 radiographically occult fractures. One fracture was identified on MRI that was not seen on cone-beam CT. Cone-beam CT had sensitivity of 98.3% (95% CI, 91.1-100%), specificity of 100% (95% CI, 93.7-100%), positive predictive value of 100%, and negative predictive value of 98.3% (95% CI, 89.1-100%). Accuracy was 99.1% (95% CI, 95.3-100%). CONCLUSION. Incorporating cone-beam CT into routine clinical practice as part of a standardized diagnostic algorithm yielded a 50% fracture detection rate in patients with negative wrist radiographs but ongoing clinical concern for radiocarpal fracture. Cone-beam CT provides more diagnostic information than radiographs at a lower radiation dose than conventional MDCT. Given the poor accuracy of radiographs for acute radiocarpal fractures and the high fracture prevalence in this cohort, we feel that cone-beam CT should be regarded as the new standard of care in the investigation of these patients.
Collapse
|
25
|
Nardi C, Calistri L, Grazzini G, Desideri I, Lorini C, Occhipinti M, Mungai F, Colagrande S. Is Panoramic Radiography an Accurate Imaging Technique for the Detection of Endodontically Treated Asymptomatic Apical Periodontitis? J Endod 2018; 44:1500-1508. [PMID: 30154006 DOI: 10.1016/j.joen.2018.07.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 06/12/2018] [Accepted: 07/02/2018] [Indexed: 12/17/2022]
Abstract
INTRODUCTION This study aimed to evaluate the diagnostic accuracy of panoramic radiography (PAN) for the detection of clinically/surgically confirmed apical periodontitis (AP) in root canal-treated teeth using cone-beam computed tomographic (CBCT) imaging as the reference standard. METHODS Two hundred forty patients with endodontically treated AP (diseased group) were detected via CBCT imaging using the periapical index system. They were divided into groups of 20 each according to lesion size (2-4.5 mm and 4.6-7 mm) and anatomic area (incisor, canine/premolar, and molar) in both the upper and lower arches. Another 240 patients with root filling and a healthy periapex (healthy group) were selected. All diseased and healthy patients underwent PAN first and a CBCT scan within 40 days. The periapical index system was also used to assess AP using PAN. Sensitivity, specificity, diagnostic accuracy, positive predictive value, and negative predictive value for PAN images with respect to CBCT imaging were analyzed. The k value was calculated to assess both the interobserver reliability for PAN and the agreement between PAN and CBCT. RESULTS PAN showed low sensitivity (48.8), mediocre negative predictive value (64.7), good diagnostic accuracy (71.3), and high positive predictive value (88.6) and specificity (93.8). Both interobserver reliability for PAN and agreement between PAN and CBCT were moderate (k = 0.58 and 0.42, respectively). The best identified AP was located in the lower canine/premolar and molar areas, whereas the worst identified AP was located in the upper/lower incisor area and upper molar area. CONCLUSIONS PAN showed good diagnostic accuracy, high specificity, and low sensitivity for the detection of endodontically treated AP.
Collapse
Affiliation(s)
- Cosimo Nardi
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy.
| | - Linda Calistri
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Giulia Grazzini
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Isacco Desideri
- Department of Experimental and Clinical Biomedical Sciences, Radiotherapy Unit, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Chiara Lorini
- Department of Health Science, University of Florence, Florence, Italy
| | - Mariaelena Occhipinti
- Department of Experimental and Clinical Medicine, Section of Respiratory Medicine, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Francesco Mungai
- Department of Radiology, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Stefano Colagrande
- Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit, University of Florence, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| |
Collapse
|